At least 109 records · Page 6

Parametric study of the lubrication of thrust loaded 120-mm bore ball bearings to 3 million DN

A parametric study was performed with 120-mm bore angular-contact ball bearings under varying thrust loads, bearing and lubricant temperatures, and cooling and lubricant flow rates. Contact angles were nominally 20 and 24 deg with bearing speeds to 3 million DN. Endurance tests were run at 3 million DN and a temperature of 492 K (425 F) with 10 bearings having a nominal 24 deg contact angle at a thrust load of 22241 N (5000 lb). Bearing operating temperature, differences in temperatures between the inner and outer races, and bearing power consumption can be tuned to any desirable operating requirement by varying 4 parameters. These parameters are outer-race cooling, inner-race cooling, lubricant flow to the inner race, and oil inlet temperature. Preliminary endurance tests at 3 million DN and 492 K (425 F) indicate that long term bearing operation can be achieved with a high degree of reliability.

Signer, H.↗

Capillary forces exerted by liquid drops caught between crossed cylinders. A 3-D meniscus problem with free contact line

The Young-Laplace equation is solved for three-dimensional menisci between crossed cylinders, with either the contact line fixed or the contact angle prescribed, by means of the Galerkin/finite element method. Shapes are computed, and with them the practically important quantities: drop volume, wetted area, capillary pressure force, surface tension force, and the total force exerted by the drop on each cylinder. The results show that total capillary force between cylinders increases with decreasing contact angle, i.e. with better wetting. Capillary force is also increases with decreasing drop volume, approaching an asymptotic limit. However, the wetted area on each cylinder decreases with decreasing drop volume, which raises the question of the optimum drop volume to strive for, when permanent bonding is sought from solidified liquid. For then the strength of the bond is likely to depend upon the area of contact, which is the wetted area when the bonding agent was introduced in liquid form.

Patzek, T. W.↗

Atomic Oxygen Textured Polymers

Atomic oxygen can be used to microscopically alter the surface morphology of polymeric materials in space or in ground laboratory facilities. For polymeric materials whose sole oxidation products are volatile species, directed atomic oxygen reactions produce surfaces of microscopic cones. However, isotropic atomic oxygen exposure results in polymer surfaces covered with lower aspect ratio sharp-edged craters. Isotropic atomic oxygen plasma exposure of polymers typically causes a significant decrease in water contact angle as well as altered coefficient of static friction. Such surface alterations may be of benefit for industrial and biomedical applications. The results of atomic oxygen plasma exposure of thirty-three (33) different polymers are presented, including typical morphology changes, effects on water contact angle, and coefficient of static friction.

Banks, Bruce A.↗

Determination of Liquid/Gas Interface and Liquid Center of Gravity for GPM Tank with PMD Using Surface Evolver

Many spacecraft, such as the Global Precipitation Mission (GPM) spacecraft, use propellant management devices (PMDs) to control liquid propellant within propellant tanks. Surface Evolver, an energy minimization routine, is used to find liquid-gas interface shapes due to surface tension and propellant center of mass locations for varying initial liquid positions, contact angles, and fill fractions for the GPM tank with a PMD. This study shows that Surface Evolver can accurately model the liquid-gas interface and liquid center of mass location for a complicated tank and PMD. The Surface Evolver results show that the initial position of the propellant, the contact angle between the propellant and solid surfaces, and the fill fraction of the propellant can drastically affect the liquid-gas interface in the tank and thus the center of mass of the propellant.

Benson, David J.↗

Polymer Infused Composite Metal Foam as a Potential Aircraft Leading Edge Material

The leading edge of the aircraft wings must be free from three-dimensional disturbances caused by insect adhesion, ice accretion, and particle wear in order to improve flight performance, safety, and fuel efficiency of the aircraft. An innovative solution was explored in this work by infusing stainless steel composite metal foam (SS CMF) with a hydrophobic epoxy resin system. S-S CMF was made with 100% stainless steel using a powder metallurgy technique. The infused epoxy filled the macro- and microporosities, unique to SS CMF’s structure, creating a product with a density similar to that of aluminum. The contact angle, wear rate, erosion resistance, and insect adhesion of the novel infused composite metal foam were measured and compared to aluminum, epoxy and stainless steel. The infusion process was determined to fill up to 88% of the pores within the SS CMF and was found to reduce wettability and insect residue accretion. The contact angle of the infused SS CMF was 43% higher than its parent material, stainless steel, and 130% higher than aluminum. Insect residue maximum height and areal coverage were reduced by 60 and 30%, respectively, compared to aluminum. Grit blast experiments to simulate erosion resulted in a greater roughness increase for aluminum than for the parent epoxy resin or the resin-infused SS CMF. These results suggest that the durability and performance of infused SS CMF was superior compared to aluminum, which is the current leading edge material of choice. Based on the promising results under relevant wear and erosion conditions, it is concluded that the infused SS CMF can offer a potential tailored replacement to aluminum leading edge material.

Jacob C. Marx↗

Wetting Hysteresis at the Molecular Scale

The motion of a fluid-fluid-solid contact line on a rough surface is well known to display hysteresis in the contact angle vs. velocity relationship. In order to understand the phenomenon at a fundamental microscopic level, we have conducted molecular dynamics computer simulations of a Wilhelmy plate experiment in which a solid surface is dipped into a liquid bath, and the force-velocity characteristics are measured. We directly observe a systematic variation of force and contact angle with velocity, which is single-valued for the case of an atomically smooth solid surface. In the microscopically rough case, however, we find (as intuitively expected) an open hysteresis loop. Further characterization of the interface dynamics is in progress.

Jin, Wei↗

Electrostatic Properties of Polymers Subjected to Atmospheric Pressure Plasma Treatment; Correlation of Experimental Results with Atomistic Modeling

this study, PE, PTFE, PS and PMMA were exposed to a He+O2, APGD and pre and post treatment surface chemistries were analyzed by X-ray photoelectron spectroscopy and contact angle measurements. Semi-empirical and ab-initio calculations were performed to correlate the experimental results with sonic plausible molecular and electronic structure features of the oxidation process. For the PE and PS, significant surface oxidation showing C-O, C=O, and O-C=O bonding, and a decrease in the surface contact angles was observed. For the PTFE and PM MA, little change in the surface composition was observed. The molecular modeling calculations were performed on single and multiple oligomers and showed regardless of oxidation mechanism, e.g. -OH, =O or a combination thereof, experimentally observed levels of surface oxidation were unlikely to lead to a significant change in the electronic structure of PE and PS, and that the increased hydrophilic properties are the primary reason for the observed changes in its electrostatic behavior. Calculations for PTFE and PMMA argue strongly against significant oxidation of those materials, as confirmed by the XPS results.

Trigwell, S.↗

Surface settling in partially filled containers upon step reduction in gravity

A large literature exists concerning the equilibrium configurations of free liquid/gas surfaces in reduced gravity environments. Such conditions generally yield surfaces of constant curvature meeting the container wall at a particular (contact) angle. The time required to reach and stabilize about this configuration is less studied for the case of sudden changes in gravity level, e.g. from normal- to low-gravity, as can occur in many drop tower experiments. The particular interest here was to determine the total reorientation time for such surfaces in cylinders (mainly), as a function primarily of contact angle and kinematic viscosity, in order to aid in the development of drop tower experiment design. A large parametric range of tests were performed and, based on an accompanying scale analysis, the complete data set was correlated. The results of other investigations are included for comparison.

Weislogel, Marl M.↗

Predictive models for moving contact line flows

Modeling flows with moving contact lines poses the formidable challenge that the usual assumptions of Newtonian fluid and no-slip condition give rise to a well-known singularity. This singularity prevents one from satisfying the contact angle condition to compute the shape of the fluid-fluid interface, a crucial calculation without which design parameters such as the pressure drop needed to move an immiscible 2-fluid system through a solid matrix cannot be evaluated. Some progress has been made for low Capillary number spreading flows. Combining experimental measurements of fluid-fluid interfaces very near the moving contact line with an analytical expression for the interface shape, we can determine a parameter that forms a boundary condition for the macroscopic interface shape when Ca much les than l. This parameter, which plays the role of an "apparent" or macroscopic dynamic contact angle, is shown by the theory to depend on the system geometry through the macroscopic length scale. This theoretically established dependence on geometry allows this parameter to be "transferable" from the geometry of the measurement to any other geometry involving the same material system. Unfortunately this prediction of the theory cannot be tested on Earth.

Rame, Enrique↗

Experimental Measurements of Spreading of Volatile Liquid Droplets

Based on the laser shadowgraphic system used by the first author of the present paper, a simple optical system, which combined the laser shadowgraphy and the direct magnified-photography, has been developed to measure the contact angle, the spreading speed, and the evaporation rate. Additionally, the system can also visualize thermocapillary convection inside of a sessile drop simultaneously. The experimental results show that evaporation/condensation and thermocapillary convection in the sessile drop induced by the evaporation strongly affects the wetting and spreading of the drop. Condensation always promotes the wetting and spreading of the drop. Evaporation may increase or decrease the contact angle of the evaporating sessile drops, depending on the evaporation rate. The thermocapillary convection in the drop induced by the evaporation enhances the effects of evaporation to suppress the spreading.

Zhang, Neng-Li↗

Capillary Pressure of a Liquid Between Uniform Spheres Arranged in a Square-Packed Layer

The capillary pressure in the pores defined by equidimensional close-packed spheres is analyzed numerically. In the absence of gravity the menisci shapes are constructed using Surface Evolver code. This permits calculation the free surface mean curvature and hence the capillary pressure. The dependences of capillary pressure on the liquid volume constructed here for a set of contact angles allow one to determine the evolution of basic capillary characteristics under quasi-static infiltration and drainage. The maximum pressure difference between liquid and gas required for a meniscus passing through a pore is calculated and compared with that for hexagonal packing and with approximate solution given by Mason and Morrow [l]. The lower and upper critical liquid volumes that determine the stability limits for the equilibrium capillary liquid in contact with square packed array of spheres are tabulated for a set of contact angles.

Alexader, J. Iwan D.↗

Flow visualization and characterization of evaporating liquid drops

An optical system, consisting of drop-reflection image, reflection-refracted shadowgraphy and top-view photography, is used to measure the spreading and instant dynamic contact angle of a volatile-liquid drop on a non-transparent substrate. The drop-reflection image and the shadowgraphy is shown by projecting the images of a collimated laser beam partially reflected by the drop and partially passing through the drop onto a screen while the top view photograph is separately viewed by use of a camera video recorder and monitor. For a transparent liquid on a reflective solid surface, thermocapillary convection in the drop, induced by evaporation, can be viewed nonintrusively, and the drop real-time profile data are synchronously recorded by video recording systems. Experimental results obtained from this technique clearly reveal that evaporation and thermocapillary convection greatly affect the spreading process and the characteristics of dynamic contact angle of the drop.

Chao, David F.↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

Two experimental setups: High Heat Flux Pool Boiling Setup and Optical system of Measuring Contact Angle and Spreading Parameters were established and a series of experiments was conducted. The experimental work on the nucleate boiling performance of both Freon-113 and water on the composite surfaces has been finished and the results show that the composite surface with 25% volume fraction of graphite fibers in the copper matrix has the best enhancing performance. Stronger enhancement was obtained for water compared to Freon-113. The wall superheat initiating boiling was reduced 40% and 35% and the heat flux of the nucleate boiling was augmented up to ten times and 6.7 times, respectively. A bubble departure model has been presented to explain the enhancement mechanism of the boiling heat transfer on the composite surfaces. A powerful optical method to measure contact angle and spreading parameters of liquids on solid surfaces, including both transparent and non-transparent substrates, has been developed and successfully used in the measurements for various liquid-solid systems. The experimental work on identification of profiles near three-phase line by laser shadowgraphy method has been finished and the characteristics of the three-phase line for different liquid-solid systems were unveiled, which is very important to understand the mechanism of boiling under microgravity conditions. The four basic patterns of sessile profile were discovered through caustics and caustic-diffraction analysis by applying wave theory in shadowgraphy technology, which contributes to clearly explain the different characteristics of wetting and spreading of various liquids on a solid surface, and therefore to further understand the bubble departure mechanisms. A new working pattern of heat pipes using working fluids with positive surface-tension gradient against temperature was discovered and analyzed, and then the new heat pipe systems using this kind of working fluids have been presented. Two patent devices, i.e. Shadowgraphic Method to Measure Properties of Sessile Drops and Heat Pipe Systems Using New Working Fluids, have been developed; the former has been approved by The United States Patent & Trademark Office and the latter is being examined.

Source record↗

Development of graphite/copper composites utilizing engineered interfaces

In situ measurements of graphite/copper alloy contact angles were made using the sessile drop method. The interfacial energy values obtained from these measurements were then applied to a model for the fiber matrix interfacial debonding phenomenon found in graphite/copper composites. The formation obtained from the sessile drop tests led to the development of a copper alloy that suitably wets graphite. Characterization of graphite/copper alloy interfaces subjected to elevated temperatures was conducted using Scanning Electron Microscopy, Energy Dispersive Spectroscopy, Auger Electron Spectroscopy, and X Ray Diffraction analyses. These analyses indicated that during sessile drop tests conducted at 1130 C for 1 hour, copper alloys containing greater than 0.98 at pct chromium form continuous reaction layers of approx. 10 microns in thickness. The reaction layers are adherent to the graphite surface. The copper wets the reaction layer to form a contact angle of 60 deg or less. X ray diffraction results indicate that the reaction layer is Cr3C2.

Devincent, Sandra M.↗

Measurement of an Evaporating Drop on a Reflective Substrate

A figure depicts an apparatus that simultaneously records magnified ordinary top-view video images and laser shadowgraph video images of a sessile drop on a flat, horizontal substrate that can be opaque or translucent and is at least partially specularly reflective. The diameter, contact angle, and rate of evaporation of the drop as functions of time can be calculated from the apparent diameters of the drop in sequences of the images acquired at known time intervals, and the shadowgrams that contain flow patterns indicative of thermocapillary convection (if any) within the drop. These time-dependent parameters and flow patterns are important for understanding the physical processes involved in the spreading and evaporation of drops. The apparatus includes a source of white light and a laser (both omitted from the figure), which are used to form the ordinary image and the shadowgram, respectively. Charge-coupled-device (CCD) camera 1 (with zoom) acquires the ordinary video images, while CCD camera 2 acquires the shadowgrams. With respect to the portion of laser light specularly reflected from the substrate, the drop acts as a plano-convex lens, focusing the laser beam to a shadowgram on the projection screen in front of CCD camera 2. The equations for calculating the diameter, contact angle, and rate of evaporation of the drop are readily derived on the basis of Snell s law of refraction and the geometry of the optics.

Chao, David F.↗

Engineered Multifunctional Surfaces for Fluid Handling

Designs incorporating variations in capillary geometry and hydrophilic and/or antibacterial surface properties have been developed that are capable of passive gas/liquid separation and passive water flow. These designs can incorporate capillary grooves and/or surfaces arranged to create linear and circumferential capillary geometry at the micro and macro scale, radial fin configurations, micro holes and patterns, and combinations of the above. The antibacterial property of this design inhibits the growth of bacteria or the development of biofilm. The hydrophilic property reduces the water contact angle with a treated substrate such that water spreads into a thin layer atop the treated surface. These antibacterial and hydrophilic properties applied to a thermally conductive surface, combined with capillary geometry, create a novel heat exchanger capable of condensing water from a humid, two-phase water and gas flow onto the treated heat exchanger surfaces, and passively separating the condensed water from the gas flow in a reduced gravity application. The overall process to generate the antibacterial and hydrophilic properties includes multiple steps to generate the two different surface properties, and can be divided into two major steps. Step 1 uses a magnetron-based sputtering technique to implant the silver atoms into the base material. A layer of silver is built up on top of the base material. Completion of this step provides the antibacterial property. Step 2 uses a cold-plasma technique to generate the hydrophilic surface property on top of the silver layer generated in Step 1. Completion of this step provides the hydrophilic property in addition to the antibacterial property. Thermally conductive materials are fabricated and then treated to create the antibacterial and hydrophilic surface properties. The individual parts are assembled to create a condensing heat exchanger with antibacterial and hydrophilic surface properties and capillary geometry, which is capable of passive phase separation in a reduced gravity application. The plasma processes for creating antibacterial and hydrophilic surface properties are suitable for applications where water is present on an exposed surface for an extended time, such that bacteria or biofilms could form, and where there is a need to manage the water on the surface. The processes are also suitable for applications where only the hydrophilic property is needed. In particular, the processes are applicable to condensing heat exchangers (CHXs), which benefit from the antibacterial properties as well as the hydrophilic properties. Water condensing onto the control surfaces of the CHX will provide the moist conditions necessary for the growth of bacteria and the formation of biofilms. The antibacterial properties of the base layer (silver) will mitigate and prevent the growth of bacteria and formation of biofilms that would otherwise reduce the CHX performance. In addition, the hydrophilic properties reduce the water contact angle and prevent water droplets from bridging between control surfaces. Overall, the hydrophilic properties reduce the pressure drop across the CHX.

Thomas, Chris↗

On Transients in Detached Bridgman Growth

In detached Bridgman growth, a gap exists between the growing crystal and the crucible wall. According to crystal shape stability theory, only specific gap widths will be dynamically stable. Beginning with a crystal diameter that differs from stable conditions, the transient crystal growth process is analyzed. The transient shapes are calculated assuming that the growth angle is constant. Anisotropy and dynamic contact angle effects are considered. In microgravity, dynamic stability depends only on capillary effects and is decoupled from heat transfer. However, heat transfer will influence the crystal-melt interface shape. The local angles and the crystal-melt-vapor triple junction are analyzed and the applicability of the Herring formula is discussed. A potential microgravity experiment is proposed which would enhance our understanding of the detached growth dynamic stability problem.

Mazuruk, K.↗

Fluid Interface Phenomena in a Low-Gravity Environment: Recent Results from Drop Tower Experimentation

Drop towers used as experimental facilities have played a major role in the development of fundamental theory, engineering analysis, and the proofing of system designs applicable to fluid interface phenomena in a low-gravity environment. In this paper, the parameters essential to the effective use of drop tower experiments relevant to fluid interfaces with constant fluid properties are reviewed. The often dramatic influence of the contact angle and the uncertainty of the moving contact line boundary condition are emphasized. A number of sample problems buttressed by recent results from drop tower tests are discussed; these clearly demonstrate the role of inertia and the controlling influence of surface wettability and container geometry for the large length scale capillary flows that arise in fluid systems in space.