Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

City and County Commercial Building Inventories

The Commercial Building Inventories provide modeled data on commercial building type, vintage, and area for each U.S. city and county. Please note this data is modeled and more precise data may be available through county assessors or other sources. Commercial building stock data is estimated using CoStar Realty Information, Inc. building stock data. This data is part of a suite of state and local energy profile data available at the "State and Local Energy Profile Data Suite" link below and builds on Cities-LEAP energy modeling, available at the "EERE Cities-LEAP Page" link below. Examples of how to use the data to inform energy planning can be found at the "Example Uses" link below.

Array↗

High-moisture pelleting of corn stover using pilot- and commercial-scale systems: Impact of moisture content, L / D ratio and hammer mill screen size on pellet quality and energy consumption

Here, high-moisture pelleting of corn stover was tested in pilot- and commercial-scale systems. For the pilot-scale study, a 6.35 mm screen size hammer mill ground corn stover was reconditioned to moisture between 14 and 29.6% (w.b.), and 5, 7 and 9 L/D ratio pellet die were used. At 29% corn stover moisture content and L/D ratios of 5 and 9, the bulk density and durability of the pellets were ≤450 kg/m 3 and <90% and >540 kg/m 3 and >90%, respectively. Increasing the feedstock moisture and L/D ratio increased the pelleting energy. Increasing the hammer mill screen size to 11.11 mm reduced the bulk density but not the durability. The response surface models adequately described the pelleting process (R 2 ≥ 0.88), and analysis of variance showed a strong interaction between the process variables and pellet properties. Commercial-scale testing of high-moisture pelleting using 6.35 mm ground corn stover bales in the moisture range 24–26% (w.b.) produced pellets with a density of >675 kg/m 3 and durability of >98%, whereas increasing the hammer mill screen size to 11.11 mm reduced the bulk density by about 100 kg/m 3 but not the durability. The energy consumption of the commercial-scale unit operations for the high-moisture pelleting process was in the range 98–124 kW h/ton, which is 64–72% less energy than conventional pelleting that requires energy about 350 kW h/ton for biomass drying from 30% (w.b.) to 10% (w.b.) moisture content before pelleting. Pellets produced using high-moisture pelleting met International Organization for Standardization and Pellets Fuel Institute international standards. Published 2023. This article is a U.S. Government work and is in the public domain in the USA.

09 BIOMASS FUELS↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ENERGY STAR for Tenants: An Online Energy Estimation Tool for Commercial Office Building Tenants

The commercial building sector consumes over 18% of the total energy in the United States. According to the 2012 Commercial Building Energy Consumption Survey (CBECS), office buildings comprise nearly 16 billion square feet of floor space and consume 253 billion kWh of energy annually. Office buildings represent nearly one-fifth of the energy consumed by commercial buildings, more than any other building type. Therefore, monitoring and reducing energy consumption in office buildings has become an increasingly important focus across the United States. The goal of the ENERGY STAR for Tenants program is to recognize office building tenants who demonstrate commitment to energy efficiency and environmental stewardship. Tenants seeking recognition must complete five major steps: estimate energy use, meter energy use, use efficient lighting, use efficient equipment, and share data. NREL is responsible for the underlying analysis performed for step one, estimating energy use. An online survey was developed for tenants to input information about their office space and its internal loads. NREL performed a parametric analysis across a large parameter space of office buildings. The analysis results were processed to map the user inputs to output energy ranges. The mappings enable the web tool to provide users with instant energy usage estimates based on a limited number of inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

R&D Insights for Extreme Fast Charging of Medium- and Heavy-Duty Vehicles: Insights from the NREL Commercial Vehicles and Extreme Fast Charging Research Needs Workshop, August 27-28, 2019

As battery costs have declined and battery performance has improved, the applicability of vehicle electrification has expanded beyond passenger cars to the commercial vehicle sector. However, due to the larger batteries that would be needed for the medium- and heavy-duty (MDHD) sector, the electric charging capabilities to serve these larger commercial vehicles will need to be substantially more powerful than light-duty chargers. More specifically, such 'extreme fast charging' (XFC) will likely need to reach the megawatt scale to provide a full charge in less than 30 minutes in some applications. In addition, the combined cost of electrified vehicles and charging must be competitive with the costs of petroleum-based technologies and other alternatives to encourage widespread adoption of battery electric vehicles (BEVs) among MDHD fleets. Most of these fleets have a commercial mission and demand low total cost of ownership (TCO) (which motivates minimal refueling times) and high performance from their vehicles.

25 ENERGY STORAGE↗

Commercial Building Sensors and Controls Systems - Barriers, Drivers, and Costs

Optimized building sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. However, only 8% of small commercial buildings have installed sensors and controls systems-which is largely due to cost barriers. This publication seeks to increase the transparency of system costs and identify specific barriers and drivers for increased adoption. Qualitative interview data was collected from 20 interviews with industry and qualitative cost data was collected from invoices during the interviews. The greater understanding of costs and barriers associated with commercial building sensors and controls systems lays the groundwork for future steps in increasing system adoption, reducing energy consumption, and market transformation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SECARB-USA: Preliminary Regional Commercialization Plan (Task 4.4.a)

The SECARB-USA region refers to the states in the southeastern portion of the United States including Alabama, Arkansas, Florida, Georgia, Kentucky, Louisiana, Mississippi, Missouri, North Carolina, eastern Oklahoma, South Carolina, Tennessee, eastern Texas, Virginia, and West Virginia. This region is a hub for economic activity and accordingly emits almost 1 Gtpa of CO 2 which is the motivation for the development of Carbon Capture and Storage (CCS). This preliminary commercialization plan reviews the status of commercialization of CCS within the region, outlines the infrastructure buildout to achieve CO 2 reduction goals by 2050 described by the Los Alamos National Lab in Task 4.1.b (see the Task 4.1.b “Technoeconomic Analysis of Infrastructure Buildout Scenarios” report), and provides an early estimate of the economic activity and employment creation resulting from the increase in CCS activity. Additionally, this report addresses the challenges associated with commercializing CCS within the region at a large scale.

54 ENVIRONMENTAL SCIENCES↗

Managing Subsurface Pressure Buildup and Interference in Commercial-Scale CO 2 Storage Project with Proximal Injection Wells

Large-scale decarbonization using carbon capture and storage (CCS) is likely to involve many commercial-scale CO 2 storage projects located in close proximity to each other. This close proximity raises concerns over pressure interference among the storage projects. Pressure interference between injection and storage efforts can reduce the practicable CO 2 storage resource and force wells to inject CO 2 at a lower rate to avoid the fracture pressure thresholds per United States Environmental Protection Agency (EPA) Class VI well regulations to preserve injection and confining zone integrity and potentially mitigate against inducing seismic activity. These analyses employ numerical full-physics reservoir modeling to evaluate how pressure buildup fronts and CO 2 plumes evolve under commercial-scale injection volumes of CO 2 in which multiple storage sites located in close proximity occur in tandem. The simulation models mimic injection at pseudo basin-scale and assume homogeneous saline formation(s) as storage targets with a pair of upper and lower homogeneous seal layer/s. These analyses specifically investigate the efficacy of two basin-wide reservoir pressure management strategies in addressing the technical challenges associated with pressure buildup and CO 2 plume commingling. The strategies explored include: 1) enlarging the area of injection well spacing (WS) and 2) storing CO 2 in a stacked sequence (SSS) of saline formations compared to a single formation. The storage and confining zones properties assumed were held common across the scenarios, unless specified otherwise. Analyses results show that after injecting 4 million tons per year for 30 years using 4 separate wells (each injecting 1 million metric tons per year), the radius of CO 2 plume extends to a mere 3 km or less from injection wells. Meanwhile, the radius of pressure buildup ranges on the order of tens to a few hundreds of kilometers, depending on the magnitude of pressure buildup threshold that one would use to define the front. CO 2 plume commingling from different injection wells appears to occur 50 years post-injection, especially under scenarios with narrowly spaced (i.e., < 5 km apart) injection well locations. Findings from sensitivity cases on the well spacing suggest that storage formations modeled would require different well spacing to avoid fracture pressure thresholds. For instance, modeled storage formations with high fracture gradients (i.e., 0.8 psi/ft) would need less than 5–km well spacing, whereas those with lower fracture gradients (i.e., 0.7 psi/ft) would need approximately 20–km well spacing, based on assumed modeling parameters. Under stacked injection, the pressure challenges (described above) still exist but are more alleviated due to distributing the same injection volume across more available reservoir volume. These analyses demonstrate that stacked-sequence storage can effectively address the challenges, while still providing the same target CO 2 storage volumes and allowing a large number of storage projects to be deployed in the same basin by better utilizing the available storage resource across different reservoir depths. Among cases modeled, the resulting pressure buildup front is most suppressed when each storage project distributes injection volumes over several wells, each of which injects a portion of the total CO 2 across the stacked sequence. This strategy results in the smallest CO 2 aerial footprint amongst scenarios evaluated but also shows the largest reduction in the pressure buildup at the top of perforation at the injection wells (upwards of approximately 42 percent compared to the commercial-scale single-formation storage), the result of which is crucial to maintain caprock integrity. The findings presented by this research draw attention to the importance of greater coordination among storage operators and regulatory stakeholders to foster the upscaling and deployment of CCS. These analyses provide insights into required decision-making when considering multi-project deployment in a shared basin. Because these analyses evaluate a very specific geologic situation, they bear further investigations across other geologic situations.

42 ENGINEERING↗

Commercial Building Sensors and Controls Systems: Barriers, Drivers, and Costs

Building sensors and controls systems, including building automation systems, consists of the sensor-based devices installed in buildings and the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 8% of small commercial buildings, however, have installed sensors and controls systems. This is largely due to cost barriers. This work seeks to increase the transparency of system costs and identify specific barriers and drivers for increased adoption. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 20 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. The qualitative interview data was analyzed using grounded theory to identify overarching concepts, such as barriers, drivers, and future directions on the field. From this analysis, primary barriers were found to be complexity, a lack of knowledge, and money. Primary drivers were found to be the knowledge of data, savings, and remote access. The qualitative cost data was collected in the form of invoices during the interviews. The cost values were used to develop a percentage-based cost stack which identifies the average fraction of the total cost attributed to each category (hardware, software, labor, fees, and taxes). This greater understanding of costs and barriers associated with commercial building sensors and controls systems lays the groundwork for future steps in increasing system adoption, reducing energy consumption, and market transformation.

advanced building controls↗

Probabilistic Modeling of Commercial Building Occupancy Patterns Using Location-Based Map Data: Preprint

Considering occupancy patterns is crucial to simulate buildings' energy use. Current energy models use inputs that simplify the actual diversity in occupancy into static occupancy patterns and are not able to represent the numerous variations in occupancy patterns between buildings and across different locations. Recently, inferring occupancy schedules from metered electricity consumption data was used to model occupancy in commercial buildings. However, the translation from metered data to occupancy schedules requires many assumptions that might not capture the reality, and the process is hindered by the availability of data from advanced metering infrastructure. With the development of information technologies, occupancy modeling should not be limited to traditional approaches. The prevalence of social networks and location services with real-time user feedback provides publicly accessible data via Maps Application Programming Interfaces (APIs) such as Google Maps, SafeGraph, Mapbox, Foursquare, etc. This paper presents an automated framework for modeling parametric occupancy patterns using such APIs to calibrate commercial district buildings' energy models. This process includes three main steps: data extraction and processing, parametric schedules generation, and schedules integration. We demonstrated this framework in districts where we used maps API to generate more accurate behavioral patterns for operations and electric vehicle charging events. We used these patterns to determine differences in energy use across key sociodemographic and spatial parameters. The presented method has the potential for worldwide applications. Users can utilize this framework to extract data for selected locations of interest to create more realistic behavioral patterns for commercial facilities across different districts.

building energy modeling↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Sensors and Controls Systems: Barriers and Drivers: Preprint

Building sensors and controls systems, including building automation systems, comprise the sensor-based devices installed in buildings as well as the control and automation of those devices. Optimized sensors and controls systems could lead to 29% annual energy savings in commercial buildings and are integral to the growth of grid-interactive efficient buildings. Only 13% of small commercial buildings, however, have installed sensors and controls systems, largely because of cost barriers. To accelerate adoption, this work seeks to increase the transparency of system costs and identify specific barriers and drivers. To gather industry insights, the team reached out to building owners, vendors, and contractors and conducted 21 interviews with the goal of collecting cost data and market characteristics regarding building sensors and controls. We collected the cost data in the form of invoices and used it to develop a percentage-based cost category breakdown. The interview data were analyzed using grounded theory to identify overarching concepts such as barriers, drivers, and future directions. From this analysis, we found the primary barriers to be complex and confusing systems, lack of user skills, and financial concerns, and the primary drivers to be operational benefits, insight into operations, and remote access to data. The future directions analysis highlighted the potential technological solutions to address gaps and barriers, as well as predicted drivers to increase adoption. This greater understanding of the costs, barriers, and drivers associated with commercial building sensors and controls systems lays the groundwork for increasing system adoption, reducing energy consumption, and transforming the market.

building automation system↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

Characterization of the indoor far-field aerosol transmission in a model commercial office building

As businesses gradually reopen and employees return to work, the potential spread of SARS-CoV-2 and its variants through airborne transmission via the heating, ventilation, and air-conditioning (HVAC) systems of commercial building raises concerns. Since the general practice in commercial buildings is to use low-efficiency air filters and given that indoor air is generally recycled, the degree to which cross-zone aerosol transmission occurs is of interest. To quantify the cross-zone aerosol transmission, experiments were conducted using a synthetic test aerosol in the five zones on the first floor of a model commercial office building at the Oak Ridge National Laboratory. Because the synthetic aerosol was tagged with fluorescent salt, the aerosol generated from the source zone can be distinguished from the background aerosols due to its unique fluorescent signal. Data from cross-zone campaigns showed that submicron-aerosol transmission was higher than the micron aerosols. In campaigns with doors closed, the submicron aerosol transmission was less than 16% and less than 11% for micron aerosol transmission. Finally, opening the interior doors that connecting different zones can significantly enhance the aerosol transmission for zones at the close proximity to the source, but has less impact on those farther away.

60 APPLIED LIFE SCIENCES↗

Performance investigation of alkaline direct methanol fuel cell with commercial PGM-free cathodic materials

Because little progress has been made in investigating the performance of alkaline direct methanol fuel cells (ADMFCs) with commercial materials (including platinum group metal (PGM)-free catalysts, anion exchange ionomers (AEIs), and anion exchange membranes (AEMs)), the objective of this work is to evaluate the performance of ADMFCs with all commercial materials, in order to establish a reference against which the performance of newly developed materials can be compared. Fe-N-C catalysts, Fumasep (FAA-3-50) based AEMs, and FAA3 based AEIs are here employed, and the parameters such as of operating temperature and methanol concentration are investigated and optimized. Electrochemical measurements show a performance increase with the temperature from 40 to 60 °C, and with the methanol concentration (from 1 to 5 M); followed by insignificant decrease with the further increase to 10 M. The best performance is achieved with 5 M methanol at 60 °C, and the remarkable powder density of 48.2 mW cm -2 was demonstrated under these conditions. This work provides insight into the large-scale application of ADMFC with commercial PGM-free materials.

25 ENERGY STORAGE↗

Translating a Material Discovery into a Commercial Product in the Modern Lithium-ion Battery Market

Lithium-ion batteries are essential for portable technology and are now poised to disrupt a century of combustion-based transportation. The electrification revolution could eliminate our reliance on fossil fuels and enable a clean energy future; advanced batteries would facilitate this transition. However, owing to the demanding performance, cost, and safety requirements, it is challenging to translate new materials from laboratory prototypes to commercial products. This Perspective describes that journey toward commercialization for a new lithium-ion battery anode material, TiNb2O7 (TNO). TNO is intended as an alternative to graphite or Li4Ti5O12 with better rate and safety characteristics than the former, and higher energy density than the latter. The high capacity of TNO stems from multielectron redox of Nb5+ to Nb3+, its operating voltage window well above Li+/Li reduction potential prevents lithium dendrite formation, and its open crystal structure leads to high-power performance. Nevertheless, the creation of a practical TNO anode was non-linear and non-trivial. Its history is built on 30 years on fundamental science that preceded its application as a battery, and its battery development included a nearly 30-year gap. The insights and lessons 2 contained in this Perspective, many of them acquired firsthand, serve two purposes: (i) to unite the disparate studies of TiNb2O7 into a coherent modern understanding relevant to its application as a battery material and (ii) to highlight some of the considerations of commercializing a new material that affect TiNb2O7 as well as new electrode candidates more generally.

Griffith, Kent J.↗

Nondestructive Analysis of Commercial Batteries

Electrochemical batteries play a crucial role for powering portable electronics, electric vehicles, large-scale electric grids, and future electric aircraft. However, key performance metrics such as energy density, charging speed, lifespan, and safety raise significant consumer concerns. Enhancing battery performance hinges on a deep understanding of their operational and degradation mechanisms, from material composition and electrode structure to large-scale pack integration, necessitating advanced characterization methods. These methods not only enable improved battery performance but also facilitate early detection of substandard or potentially hazardous batteries before they cause serious incidents. Here, this review comprehensively examines the operational principles, applications, challenges, and prospects of cutting-edge characterization techniques for commercial batteries, with a specific focus on in situ and operando methodologies. Furthermore, it explores how these powerful tools have elucidated the operational and degradation mechanisms of commercial batteries. By bridging the gap between advanced characterization techniques and commercial battery technologies, this review aims to guide the design of more sophisticated experiments and models for studying battery degradation and enhancement.

36 MATERIALS SCIENCE↗