Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Where and When Does Solar Plus Storage Make Sense for Commercial Buildings?

As the capital cost of battery energy storage systems (BESS) declines, opportunities for commercial buildings to achieve net savings through peak demand management and energy arbitrage are emerging. National Renewable Energy Laboratory researchers modeled energy storage project economics - with and without accompanying solar photovoltaic systems - using local utility rates, ASHRAE climate zones, and solar intensity data to identify regions where these systems deliver life cycle savings now and in future cost scenarios.

battery energy storage systems↗

Development of National New Construction Weighting Factors for the Commercial Building Prototype Analyses (2003-2018)

The U.S. Department of Energy (DOE), Office of Building Technologies tasked Pacific Northwest National Laboratory to develop construction weights for various commercial building categories for the purpose of estimating weighted national energy savings from the development of ANSI/ASHRAE/IESNA Standard 90.1-2019 compared to ANSI/ASHRAE/IESNA Standard 90.1-2016. Disaggregate construction volume data was acquired from the McGraw Hill Construction Database for the years 2003-2018 and analyzed to develop detailed construction weights by climate zones, subzones and by states. These weights are provided in this report and will be subsequently used in developing a weighted national energy savings estimate for the impact of the 2019 standard. For the current update, PNNL reviewed the same data source with the latest construction data for the years 2003-2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What We Learned From Analyzing 18 Million Rows of Commercial Buildings’ HVAC Fault Data

To achieve ambitious decarbonization goals it is critical that buildings operate to their full potential. Commercial HVAC systems, however, experience a wide range of operational faults, adversely affecting energy consumption, occupant comfort, and maintenance costs. Analytical tools such as fault detection & diagnostics (FDD) software identify and help diagnose these types of sensing, mechanical, or control-related faults. While significant energy savings has been documented for FDD, along with limited-scale studies on technical capabilities, there is a lack of empirical data on faults being reported by FDD tools. With FDD deployment accelerating significantly over the past decade there is an opportunity to gather and analyze data on commercial HVAC operational problems at an unprecedented scale. Such data could address many questions such as: [a] What faults are most commonly reported?; and [b] How does fault reporting vary by time of year and other possible drivers? A recent study into FDD fault reporting amassed the largest U.S. dataset of commercial HVAC air-side fault records, drawn from multi-year monitoring across over 60,000 pieces of HVAC equipment. The results of this study provide granular data on fault reporting for over 90 unique fault types. In this paper we provide an overview of the research process and highlight key findings and lessons learned. This study presents an extraordinary level of detail on FDD fault reporting characteristics across many climate zones and building types. Armed with these new insights, commercial building industry stakeholders can make better informed decisions when designing, configuring, and operating commercial HVAC systems.

Crowe, Eliot↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building HVAC Technology Challenge - Carrier (Final Report)

The purpose of this Cooperative Research and Development Agreement (CRADA) was to test two rooftop commercial heating, ventilation, and air conditioning (HVAC) systems supplied by Carrier Corporation to determine if they met the laboratory test requirements of the United States Department of Energy (DOE) Commercial Building HVAC Technology Challenge (hereafter noted as “the Challenge”). Results of the laboratory testing completed at Oak Ridge National Laboratory (ORNL) demonstrated that the systems met all requirements of the Challenge. Carrier Corporation has successfully completed this aspect of the Challenge. This CRADA report will briefly describe the Challenge, the test plan created to measure the success of systems provided by Challenge participants, and the results of laboratory testing of the Carrier commercial rooftop systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets of Faults in Variable Air Volume Terminal Units in a Multi-Zone Commercial Building

Faults in HVAC systems can decrease system efficiency and equipment lifespan, leading to 5%–30% of energy consumption being wasted in commercial buildings. We identified two common faults in HVAC variable air volume systems: a stuck damper fault in the variable air volume terminal unit and a discharge airflow sensor fault. We conducted three sets of damper stuck tests and two sets of airflow sensor tests, each including a fault-free scenario and scenarios with varying levels of faults, over one day. The faults were implemented in Oak Ridge National Laboratory’s two-story Flexible Research Platform building to generate a high-quality, well-controlled dataset covering fault-induced and fault-free scenarios. The test building, fault test scenarios, and data validation are described here. The open-source dataset includes 1 min intervals of weather and building data on the presence and absence of building faults. This dataset can be used to analyze the effects of HVAC system faults on system operation and indoor building conditions, and to develop or evaluate a fault detection and diagnosis algorithm.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The application of photovoltaic roof shingles to residential and commercial buildings

The recent development of a shingle-type solar-cell module makes it possible to incorporate easily photovoltaic power generation into the sloping roofs of residential or commercial buildings. These modules, which use a closely packed array of nineteen 53-mm-diameter circular solar cells, are capable of producing 101 watts/sq m of module area under standard operating conditions. This module performance is achievable by the use of solar cells with an average efficiency of 13.3 percent at 1 kW/sq m air-mass-1.5 insolation and at a cell temperature of 28 C. When these modules are mounted on a sloping south-facing roof which is insulated on the rear surface, the annual energy generated at the maximum power operating point will vary from 255.6 to 137.3 kWh/sq m of module area depending on the site location, with Albuquerque, NM, and Seattle, WA, representing the highest and lowest values of the thirteen sites considered.

Shepard, N. F., Jr.↗

Solar-Energy System for a Commercial Building--Topeka, Kansas

Report describes a solar-energy system for space heating, cooling and domestic hot water at a 5,600 square-foot (520-square-meter) Topeka, Kansas, commercial building. System is expected to provide 74% of annual cooling load, 47% of heating load, and 95% of domestic hot-water load. System was included in building design to maximize energy conservation.

Source record↗

A Critical Exploration of the Efficiency Impacts of Demand Response From HVAC in Commercial Buildings

Increasing quantities of renewable energy generation has yielded a need for greater energy storage capacity in power systems. Thermal storage in variable air volume (VAV) heating, ventilation, and air conditioning (HVAC) in commercial buildings has been identified as an inexpensive source of grid storage, but the true costs are not known. Recent literature explores the inefficiency associated with providing grid services from these HVAC-based demand response (DR) resources by employing a battery analogy to calculate round-trip efficiency (RTE). Results vary significantly across studies and in some cases reported efficiencies are strikingly low. This article has three objectives to address these prior results. First, we synthesize and expand on insights into existing literature by systematically exploring the potential causes for the discrepancies in results. We reinforce previous work indicating baseline modeling may drive differences across studies and deduce that control accuracy plays a role in the major differences between experiments and simulation. Second, we discuss why the RTE metric is problematic for DR applications, discuss another proposed metric, additional energy consumption (AEC), and propose an extension, which we call uninstructed energy consumption (UEC), to evaluate DR performance. Finally, we explore the merits of different metrics using experimental data and highlight UEC's reduced sensitivity to the characteristics of the DR signal than previously proposed metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in Des Moines, Cedar Rapids, and Sioux Falls: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in the Greater Little Rock Area: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in Northwestern PA, Ashtabulam, and Chautauqua Counties: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗