Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Code of Record”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Time delay and distance measurement

A method for measuring time delay and distance may include providing an electromagnetic radiation carrier frequency and modulating one or more of amplitude, phase, frequency, polarization, and pointing angle of the carrier frequency with a return to zero (RZ) pseudo random noise (PN) code. The RZ PN code may have a constant bit period and a pulse duration that is less than the bit period. A receiver may detect the electromagnetic radiation and calculate the scattering profile versus time (or range) by computing a cross correlation function between the recorded received signal and a three-state RZ PN code kernel in the receiver. The method also may be used for pulse delay time (i.e., PPM) communications.

Abshire, James B.↗

CodeScribe Agent

SF-26-086 CodeScribe introduces a structured, multi-stage pipeline that combines deterministic program analysis with LLM-powered translation to enable incremental, testable Fortran-to-C++ migration. First, `code-scribe index` traverses the project directory tree and produces `scribe.yaml` metadata files recording all modules, subroutines, and functions at each level, giving the LLM accurate structural context instead of a hallucinated codebase model. Second, `code-scribe draft` performs the deterministic portion of translation — converting Fortran types to C++ equivalents, replacing `use` statements with `#include` and `using namespace` directives, and detecting constructs requiring special handling — while embedding`scribe-prompt` annotations that guide the LLM through non-trivial cases such as statement-function-to-lambda conversions and `extern "C"` wrapper generation. Third, `code-scribe translate` applies project-specific TOML-based few-shot prompt templates and submits the composed prompt to a pluggable LLM backend (OpenAI, Anthropic, Argonne ARGO, any OpenAI-compatible endpoint, or local Hugging Face checkpoints), producing a C++ source file, a header, and a Fortran-C++ interface file for each translated routine so the codebase compiles and runs correctly throughout the migration. Beyond translation, CodeScribe includes a tool-using coding agent (`code-scribe agent`) with read, bash, edit, and write capabilities, and a bounded loop mode (`code-scribe loop`) that runs repeated stateless agent sessions over a task file with restricted tool access — enabling sustained, auditable software development workflows for broader scientific computing tasks.

Dhruv, Akash [Argonne National Laboratory (ANL), A↗

EV-ELM (Electric Vehicle Policies with the Energy Language Model) [SWR-25-156]

Electric Vehicle Policies with the Energy Language Model (EV-ELM) leverages previous work using Large Language Models (LLMs) to find, download, and parse policy information related to energy infrastructure. In this application, we use LLMs to find policy documents related to the permitting and installation of electric vehicle charging infrastructure. This software contains the code to find, download, and parse these documents, while a related data record in the Open Energy Data Initiative (OEDI) will include the resulting output dataset that can be used for downstream analysis. The EV-ELM repository contains code for the EV-ELM project, which focuses on retrieving and processing EV permitting processes using large language models. The project is composed of two pipelines: (1) a web scraping pipeline for discovering and downloading EV permitting documents, and (2) a document parsing and extraction pipeline that processes the downloaded files to produce structured data. The web scraping pipeline is designed to extract relevant information from various websites, while the document parsing pipeline processes and analyzes the extracted documents to derive meaningful insights. Both pipelines depend on the NLR elm repository, which provides essential tools and functionalities for handling and processing the data. The web scraping pipeline is a modified version of the ordinance_gpt example within the elm repository. It has been adapted to fit the specific requirements of the EV-ELM project, ensuring that it effectively captures and processes the necessary information related to EV permitting.

Olson, Reid [National Laboratory of the Rockies (N↗

Applications of digital image acquisition in anthropometry

A description is given of a video kinesimeter, a device for the automatic real-time collection of kinematic and dynamic data. Based on the detection of a single bright spot by three TV cameras, the system provides automatic real-time recording of three-dimensional position and force data. It comprises three cameras, two incandescent lights, a voltage comparator circuit, a central control unit, and a mass storage device. The control unit determines the signal threshold for each camera before testing, sequences the lights, synchronizes and analyzes the scan voltages from the three cameras, digitizes force from a dynamometer, and codes the data for transmission to a floppy disk for recording. Two of the three cameras face each other along the 'X' axis; the third camera, which faces the center of the line between the first two, defines the 'Y' axis. An image from the 'Y' camera and either 'X' camera is necessary for determining the three-dimensional coordinates of the point.

Woolford, B.↗

A system for analysis and classification of voice communications

A method for analysis and classification of verbal communications typically associated with manned space missions or simulations was developed. The study was carried out in two phases. Phase 1 was devoted to identification of crew tasks and activities which require voice communication for accomplishment or reporting. Phase 2 entailed development of a message classification system and a preliminary test of its feasibility. The classification system permits voice communications to be analyzed to three progressively more specific levels of detail and to be described in terms of message content, purpose, and the participants in the information exchange. A coding technique was devised to allow messages to be recorded by an eight-digit number.

Older, H. J.↗

VLSI Neural Networks Help To Compress Video Signals

Advanced analog/digital electronic system for compression of video signals incorporates artificial neural networks. Performs motion-estimation and image-data-compression processing. Effectively eliminates temporal and spatial redundancies of sequences of video images; processes video image data, retaining only nonredundant parts to be transmitted, then transmits resulting data stream in form of efficient code. Reduces bandwidth and storage requirements for transmission and recording of video signal.

Fang, Wai-Chi↗

Magellan Recorder Data Recovery Algorithms

This paper describes algorithms implemented by the Magellan High Rate Processor to recover radar data corrupted by the failure of an onboard tape recorder that dropped bits. For data with error correction coding, an algorithm was developed that decodes data in the presence of bit errors and missing bits.

Error↗

Association of post-COVID phenotypic manifestations with new-onset psychiatric disease

Acute COVID-19 infection can be followed by diverse clinical manifestations referred to as Post Acute Sequelae of SARS-CoV2 Infection (PASC). Studies have shown an increased risk of being diagnosed with new-onset psychiatric disease following a diagnosis of acute COVID-19. However, it was unclear whether non-psychiatric PASC-associated manifestations (PASC-AMs) are associated with an increased risk of new-onset psychiatric disease following COVID-19. A retrospective electronic health record (EHR) cohort study of 2,391,006 individuals with acute COVID-19 was performed to evaluate whether non-psychiatric PASC-AMs are associated with new-onset psychiatric disease. Data were obtained from the National COVID Cohort Collaborative (N3C), which has EHR data from 76 clinical organizations. EHR codes were mapped to 151 non-psychiatric PASC-AMs recorded 28–120 days following SARS-CoV-2 diagnosis and before diagnosis of new-onset psychiatric disease. Association of newly diagnosed psychiatric disease with age, sex, race, pre-existing comorbidities, and PASC-AMs in seven categories was assessed by logistic regression. There were significant associations between a diagnosis of any psychiatric disease and five categories of PASC-AMs with odds ratios highest for neurological, cardiovascular, and constitutional PASC-AMs with odds ratios of 1.31, 1.29, and 1.23 respectively. Secondary analysis revealed that the proportions of 50 individual clinical features significantly differed between patients diagnosed with different psychiatric diseases. Our study provides evidence for association between non-psychiatric PASC-AMs and the incidence of newly diagnosed psychiatric disease. Significant associations were found for features related to multiple organ systems. This information could prove useful in understanding risk stratification for new-onset psychiatric disease following COVID-19. Prospective studies are needed to corroborate these findings.

60 APPLIED LIFE SCIENCES↗

Cardiovascular Disease Outcomes Among the NASA Astronaut Corps

BACKGROUND: Acute effects of spaceflight on the cardiovascular system have been studied extensively, but the combined chronic effects of spaceflight and aging are not well understood. Preparation for and participation in spaceflight activities are associated with changes in the cardiovascular system such as decreased carotid artery distensibility and decreased ventricular mass which may lead to an increased risk of cardiovascular disease. Additionally, astronauts who travel into space multiple times or for longer durations may be at an increased risk across their lifespan. To that end, the purpose of this study was to determine the incidence of common cardiovascular disease (CVD) outcomes among the NASA astronaut corps during their active career and through retirement. METHODS: Cardiovascular disease outcomes were defined as reports of any of the following: myocardial infarction (MI), revascularization procedures (coronary artery bypass graft surgery [CABG] or percutaneous coronary intervention [PCI]), hypertension, stroke or transient ischemic attack [TIA], heart failure, or total CVD (as defined by the AHA - combined outcome of MI, Angina Pectoris, heart failure, stroke, and hypertension). Each outcome was identified individually from review of NASA's Electronic Medical Record (EMR), EKG reports, and death certificates using ICD-9 codes as well as string searches of physician notes of astronaut exams that occurred between 1959 and 2016. RESULTS: Of 338 NASA astronauts selected as of 2016, 9 reported an MI, 12 reported a revascularization procedure, (7 PCI and 5 CABG), 4 reported Angina (without MI), 5 reported heart failure, 9 reported stroke/TIA, and 96 reported hypertension. Total CVD was reported in 105 astronauts. No astronaut who had an MI or revascularization procedure flew a spaceflight mission following the event. All MI, revascularization, and stroke events occurred in male astronauts. When reviewing astronaut ECG reports, abnormal ECG reports were found in only 8% of records (n=430) and mainly among retired astronauts (82%), with marked sinus bradycardia being the reason for the abnormal classification.

Charvat, Jacqueline M.↗

Mapping Between Distinct Reed-Solomon Codes

One-to-one mapping between two Reed-Solomon (RS) codes devised to enable decoder designed for one of codes to operate on other one also. Codes in question must have same N and K parameters (defined below) but otherwise be two distinct RS codes. Mapping intended to enable same ground-based decoder to decode telemetry signals from two spacecraft in two different RS codes of (N,K) = (255,223). Also useful in purely terrestrial data communications and in optical and magnetic recording and playback of digitized audio and video signals. Implemented in interface circuitry and/or software to enable communication between coding systems of different manufacturers using different RS codes within same (N,K) family.

Perlman, Marvin↗

More On The Decoder-Error Probability Of Reed-Solomon Codes

Paper extends theory of decoder-error probability for linear maximum-distance separable (MDS) codes. General class of error-correcting codes includes Reed-Solomon codes, important in communications with distant spacecraft, military communications, and compact-disk recording industry. Advancing beyond previous theoretical developments that placed upper bounds on decoder-error probabilities, author derives an exact formula for probability PE(u) that decoder will make error when u code symbols in error.

Cheung, Kar-Ming↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

Analysis of DGPS/INS and MLS/INS final approach navigation errors and control performance data

Flight tests were conducted jointly by NASA Langley Research Center and Honeywell, Inc., on a B-737 research aircraft to record a data base for evaluating the performance of a differential DGPS/inertial navigation system (INS) which used GPS Course/Acquisition code receivers. Estimates from the DGPS/INS and a Microwave Landing System (MLS)/INS, and various aircraft parameter data were recorded in real time aboard the aircraft while flying along the final approach path to landing. This paper presents the mean and standard deviation of the DGPS/INS and MLS/INS navigation position errors computed relative to the laser tracker system and of the difference between the DGPS/INS and MLS/INS velocity estimates. RMS errors are presented for DGPS/INS and MLS/INS guidance errors (localizer and glideslope). The mean navigation position errors and standard deviation of the x position coordinate of the DGPS/INS and MLS/INS systems were found to be of similar magnitude while the standard deviation of the y and z position coordinate errors were significantly larger for DGPS/INS compared to MLS/INS.

Hueschen, Richard M.↗

2021 Summer SPE Project

SPE is a project in order to develop new, more physics-based, seismic models of explosions (see Nelson et al. 2013). One key component of this effort is numerical modeling enabled by modern state-of-art code/software. Accurate modeling of the shape and amplitude of seismic waves from their generation to their propagation to remote monitoring seismic stations is important to our ability to determine the origin and strength of the source from remote recording. In this project, the modeling is performed by coupling two codes HOSS and SPECFEM3D. HOSS models the dynamic nonlinear processes happening near the explosion. SPECFEM3D computes the propagation of seismic waves as they travel through 3D complex Earth models. SPECFEM3D was modified in order to be driven by a set of time-series calculated by HOSS in lieu of a seismic source. The goal of this summer project is the investigation of several questions pertinent to the establishment of a full end-to-end modeling capability from the high-rate strain regime area to remote distances where seismic station record seismic waves generated by explosions. The investigated questions are: (1) How to perform proper filtering? Direct-solution modeling only sustains a limited range of frequency depending on the grid size. As we go from one modeling domain to the other via coupling, the mesh size is getting coarser to allow modeling at large scale but also to account for the fact that high-frequency waves do not physically travel to large distances. So filtering of the time-series generated by the near-field hydrodynamic modeling is a current practice often employed but its effects on the modeled waveforms has to be investigated. (2) Quantitative assessment of the efficiency of attenuation to remove high-frequency content of the wavefield. This assessment will allow to create meshes with a grid size appropriate to the actual physics of wave propagation for a given explosion. (3) Checking that the coupling process and the two codes respect the cylindrical symmetry that is expected in the case of a pure explosion in a half-space. (4) The effect of the state-of-stress in the near-source area on the modeled seismic waveforms. These questions will be investigated through the modeling of SPE-4P, the fourth explosion of this series because it was designed to have little interaction with the geologic surrounding and the free surface of the Earth so that it is the most explosion-like experiment, with the most symmetries to be verified.

58 GEOSCIENCES↗

Gray-Scott reaction-diffusion

This dataset consists of 1000 records in a single HDF5 file generated from the simulation code available at: https://github.com/lezahlie/greyscott_simulation. More about the Gray-Scott model is explained here https://visualpde.com/nonlinear-physics/gray-scott.html.

97 MATHEMATICS AND COMPUTING↗

Poisson's Equations for Electrostatics

This dataset consists of 1000 records in a single HDF5 file generated from the simulation code available at: https://github.com/lezahlie/esp_simulation. This code implements Poisson’s equations for electrostatics and more can be read about it here: https://en.wikipedia.org/wiki/Poisson%27s_equation#Electrostatics

97 MATHEMATICS AND COMPUTING↗

Heat equations

This dataset consists of 1000 records in a single HDF5 file generated from the simulation code available at: https://github.com/lezahlie/heat_diffusion_simulation. The specific heat equations implemented in that simulation are explained here https://visualpde.com/basic- pdes/heat- equation.html and here https://en.wikipedia.org/wiki/Heat_equation.

97 MATHEMATICS AND COMPUTING↗

Television multiplexing system

A television multiplexing system which includes a circuit that inserts a digital codes sync signal and a digital code into a video signal for identifying the channel is described. The digital sync signal and the digital coded signals are generated by a single crystal controlled clock so that they are always in synchronism with each other. In demultiplexing the signals are utilized for shifting the digital coded signals into a shift register. The shift register, in turn, activates a decoder according to the code stored in the shift register for selecting the proper recording disk or receiver for storing the video signal.

Simpkins, L. G.↗