Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Code Inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

95 records · Page 6

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of Manufacturing Quality Management Principles to PV System Installations

To help SETO/DOE achieve its goals, the IBTS team proposed a project addressing system reliability by improving installation standards and quality management. The proposed approach was designed to help achieve measurable reductions in installation defect density and improvements in the performance of PV systems by optimizing design and installation of residential and commercial PV systems. This approach addressed the soft costs associated with installations and quality management. The project demonstrated improved system reliability and reduced PV system installation costs. The software developed improved operations, decreased risk, and increased the overall value of PV systems across their lifecycle. The project used several data collection methods, including extensive industry surveys, face-to-face high-level interviews at industry conferences, stakeholder teleconferences, and in-depth interviews conducted by IBTS staff. Results from the research found the industry needs a uniform assessment method for national providers to be more efficient; the software should support both code officials and installers; most industry stakeholders would find value in a centralized software system that allows them to collect, report, and review information on in-process and completed solar installations; and mobile solutions that bridge existing knowledge gaps with inspectors and integrate with existing methodologies (such as permitting software) are of great value. The software solution developed is web-based, allowing for national access, and is built on a Google Firebase platform that can handle significant users and data. It can be used onsite or remotely, allowing for code compliance to continue despite ongoing pandemic related delays or shutdowns for local economies. The information provided by the software tool allows users to uniformly assess a system for compliance and use that aggregated data to identify training topics or create internal process designed to improving issues and reducing occurrence. This solution has multiple benefits in managing quality at time of use and promoting an increase in future safety and quality through education. Perhaps most importantly, this software increases public safety by ensuring compliance of installed systems and allows for local AHJs to remotely engage specialized and qualified solar specific expertise for oversite of the installation in their jurisdictions. Data analysis provides the quality feedback loop identifying the root cause of failure and drives installation practices to improve through training and education, resulting in systems with higher performance, greater reliability, and reduced operations and maintenance costs. With the successful completion of this project, the industry can expect reduced soft costs and increased performance and safety and will ultimately benefit from longer performing systems that cost less to operate.

14 SOLAR ENERGY↗

Reassessing Double-Ended Guillotine Break Requirements: Evidence-Based Analysis of Regulatory Assumptions After Five Decades of Nuclear Operation

After five decades of nuclear power operation encompassing more than 20,000 reactor-years across 35 countries and 647 reactors, zero double-ended guillotine breaks (DEGBs) have been documented in commercial reactor coolant systems—despite DEGB being the fundamental design-basis assumption driving Emergency Core Cooling System (ECCS) sizing, structural protection requirements, and containment design specifications. This report examines the basis for DEGB requirements in nuclear power plant design. The DEGB postulate assumes the instantaneous, complete circumferential severance of the largest diameter pipes in reactor coolant systems, driving major design requirements under 10 Code of Federal Regulations 50.46, General Design Criterion 4 and containment design specifications. The United States (4,880 reactor-years) and France (2,505 reactor-years) contribute the largest operational datasets. Probabilistic assessments estimate direct DEGB occurrence probabilities with extremely low event frequencies, far below the 10-5/reactor-year thresholds typically used to define non-credible events in nuclear-safety analyses; i.e., events with probability this low fall into beyond-design-basis events. Current material-science knowledge demonstrates that the ductile steel materials used in nuclear piping systems exhibit stable crack-growth behavior fundamentally incompatible with instantaneous severance. International regulatory experience, particularly Germany’s comprehensive break-preclusion implementation, and successful leak-before-break (LBB) applications in almost all of U.S. pressurized water reactor units validate that alternatives can maintain safety performance while reducing economic burden. Current DEGB protection systems impose estimated lifetime costs of hundreds of millions of dollars per unit, over the life of a plant across the nuclear industry (including ongoing costs), representing substantial resource allocation toward scenarios with extremely low probability. Although this report acknowledges uncertainties regarding long-term aging effects, potential synergistic degradation mechanisms, and site-specific seismic considerations that warrant continued evaluation as regulatory policy evolves, there remains no documented evidence that a DEGB has occurred as a consequence of the conditions or mechanisms described in this report. This report acknowledges the Nuclear Regulatory Commission’s (NRC’s) recent efforts—outlined in the draft Interim Staff Guidance (ISG) NRC-DSS-ISG-2025-XX (“Treatment of Certain Loss-of-Coolant Accident Locations as Beyond-Design-Basis Accidents Draft Interim Staff Guidance”)—to reduce overly conservative requirements for large-break loss of coolant accidents through technical justifications and exemptions. However, extensive operating experience and validated methodologies—such as LBB and in-service inspection programs—demonstrate that the probability of a DEGB in reactor coolant-loop piping is extremely low, even under seismic conditions. The authors and reviewers of this report recommend that DEGB be removed as a design-basis event through formal rulemaking, rather than case-by-case exemptions, to better reflect credible failure modes, align with current data, and align with modern, risk-informed safety analysis.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

GPR Robotic Assisted Non-Destructive Evaluation of Concrete Structures - 20196

Reinforced concrete structures are always under exposure of internal or external deteriorations due to many factors such as environmental, nuclear radiation or even construction deficiencies. The use of nondestructive test is one of the reliable methods to inspect structural members. In this case, GPR has a good capability to detect inside deteriorations of concrete structures. However, in many cases it is hard to inspect structural members by hand due to safety issues or inaccessibility. Thus, an alternative way to reduce such risks is to employ robot to carry nondestructive equipment. In this research, twelve reinforced concrete RC beams (8 x 16 x 96, width, height and length) are cast in the lab. Three RC beams have no defect and nine others various defects such as corrosion, de-bonded bars, void, delamination and honeycombing. The one-point load is applied at the center of the RC beam. The loading level is carried out at three levels: 50%, 75% and 100% of maximum load and total load-displacement diagram are performed. The load is held at each level and the robotic GPR is used to scan the side of RC beams. Then, RADAN software is employed to find out any defects at different loading conditions and visualize the crack propagation. The RADAN results show that the pattern of crack propagation for corrosion and debonding are same. Also, the load-displacement results present that inside defect cause reduction of load-capacity of RC beam. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗