Poleward shift and intensified variability of Kuroshio-Oyashio extension and North Pacific Transition Zone under climate change
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.
The health and well-being of plants and soil is crucial for all life on Earth. It is well-known that vegetation cover follows climatic zones, and plants respond to climatic drivers such as temperature and precipitation. It is also well-known that plant health depends on the properties and health of the soil, and that strong interactions among biota above and belowground dictate the functioning of both realms. Yet, soils and the processes occurring belowground are often considered a “black box,” and are treated very simplistically in our efforts to understand, quantify, and model the future of the planet. Our understanding of the interactions between plants and soils is also far from complete and offers some of the most important research frontiers in community ecology, biogeochemistry, and global change science.
Previous studies have identified the oversimplified root system representation as a key factor leading to inaccuracies in vegetation‐atmosphere feedbacks. In this study, a dynamic root water uptake scheme in the Noah‐MP land surface model has been coupled to the Weather Research and Forecasting (WRF) model to investigate its impact on the surface hydroclimate variables and land‐atmosphere interactions. To evaluate the impact of the dynamic root, two coupled simulations were conducted, one with the dynamic root water uptake scheme (DynRt) and one with the static root water uptake scheme (StcRt), which is based on the default root representation in Noah‐MP, with slight modifications, primarily in vegetation‐related parameters. Both DynRt and StcRt simulations were conducted with a small ensemble of three members to account for variations in physical parameterizations, initial and boundary forcing and model setup. When compared with reference data sets, the DynRt simulations show improved results than the StcRt simulations, reducing biases in the simulated leaf area index, surface energy fluxes, soil moisture and precipitation. Two different mechanisms through which roots affect land‐atmosphere coupling have been identified. Over the transitional climate zone between the dry and wet climate, the dynamic root scheme affects surface climate and land‐atmosphere coupling mainly through changes in soil moisture through hydraulic redistribution by plant root system. Over the energy‐limited mesic zone, the dynamic root affects regional land‐atmosphere coupling mainly through changes in carbon allocation. This work highlights the importance of dynamic root representation in improving vegetation‐atmosphere simulations by enhancing predictions of water, energy, and carbon fluxes.
Phosphorus (P) limitation of aboveground plant production is usually assumed to occur in tropical regions but rarely elsewhere. Here we report that such P limitation is more widespread and much stronger than previously estimated. In our global meta-analysis, almost half (46.2%) of 652 P-addition field experiments reveal a significant P limitation on aboveground plant production. Globally, P additions increase aboveground plant production by 34.9% in natural terrestrial ecosystems, which is 7.0–15.9% higher than previously suggested. In croplands, by contrast, P additions increase aboveground plant production by only 13.9%, probably because of historical fertilizations. The magnitude of P limitation also differs among climate zones and regions, and is driven by climate, ecosystem properties, and fertilization regimes. In addition to confirming that P limitation is widespread in tropical regions, our study demonstrates that P limitation often occurs in other regions. This suggests that previous studies have underestimated the importance of altered P supply on aboveground plant production in natural terrestrial ecosystems.
This archive contains both a link to Oak Ridge National Laboratory's Ground Source Heat Pump (GSHP) Screening Tool and related resources documenting its development, technical features, and applications. The web-based screening tool is a techno-economic analysis resource designed to evaluate the feasibility, costs, and benefits of implementing GSHP systems in buildings across various U.S. climate zones. It is intended for use by building owners, HVAC system designers, and installers to support decision-making in residential and commercial applications, incorporating advanced modeling capabilities such as ground heat exchanger design. The included resources detail the tool's creation and use, covering topics such as innovative ground heat exchanger design methodologies, the development of an open library of g-functions for borehole configurations, and studies on GSHP performance and economic viability in retrofitting single-family homes.
Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.
Understanding the contribution of soil microbial communities to ecosystem processes is critical for predicting terrestrial ecosystem feedbacks under changing climate. Our current understanding lacks a consistent strategy to formulate the linkage between microbial systems and ecosystem processes due to the presumption of functional redundancy in soil microbes. Here we present a global soil microbial metagenomic analysis to generalize patterns of microbial taxonomic compositions and functional potentials across climate and geochemical gradient. Our analyses show that soil microbial taxonomic composition varies widely in response to climate and soil physicochemical gradients, while microbial functional attributes based on metagenomic gene abundances are redundant. Among 17 climate zones, microbial taxonomic compositions were more distinct than functional potentials, as climate and edaphic properties showed more significant influence on microbial taxonomic compositions than on functional potentials. Microbial taxonomies formed a larger and more complex co-occurrence network with more module structures than functional potentials. Functional network was strongly inter-connected among different categories, whereas taxonomic network was more positively interactive in the same taxonomic groups. This study provides strong evidence to support the hypothesis of functional redundancy in soil microbes, as microbial taxonomic compositions vary to a larger extent than functional potentials based on metagenomic gene abundances in terrestrial ecosystems across the globe.
The reconstruction of former mountain glaciers from geomorphic mapping and cosmogenic-nuclide surface-exposure dating provides a unique opportunity to infer patterns of past terrestrial climate variability. Tropical mountain glaciers are particularly valuable as there are comparatively few terrestrial climate proxies at equatorial latitudes relative to higher latitudes. As the single largest climate zone on Earth, the tropics play an outsized role in mediating global climate via the ocean-atmosphere transfer of latent heat and water vapor. Nonetheless, there remains a persistent gap in our understanding of how the tropics influenced – or were influenced by – the high-magnitude climate shifts of the Late Pleistocene, and whether this high-energy region simply responded to extratropical forcing or was itself a driver of global climatic change. To help address this knowledge gap, we analyzed geologic evidence for past glacial fluctuations in three adjacent valleys in the Sierra Nevada del Cocuy, the highest subrange of the Eastern Cordillera in the Colombian Andes, to provide a terrestrial record of atmospheric temperature during the latter part of Termination 1. Coupled with geomorphic mapping and paleo-snowline reconstructions, our beryllium-10 glacial chronology indicates that glaciers in the humid inner tropics underwent pronounced growth and gradual decay during the Antarctic Cold Reversal (14.5–12.8 ka) and Younger Dryas (12.8–11.7 ka) periods, respectively, following a trend that, according to directly dated moraine records from throughout both polar hemispheres, appears to have been global. While the specific mechanism(s) behind this large-scale behavior remains to be corroborated, we revisit the hypothesis that ocean-atmosphere heat transfer and water vapor flux are key drivers of abrupt Lateglacial temperature fluctuations. Subsequent to the Lateglacial, deglaciation of the Sierra Nevada del Cocuy accelerated during the Early Holocene, a pattern also observed in other tropical glacier records. More recently, the magnitude of snowline rise and glacier retreat over the last two centuries supports the view that modern tropospheric warming is anomalously strong at least relative to the last ∼16,000 years.
The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.
Building decarbonization via electrification on a clean grid is the most promising climate solution proposed to date for the building sector. In cold climate zones, building electrification will be driven in large part by moving from natural gas space heating to cold climate heat pumps (CCHPs). CCHPs are commercially available today, including economical cold climate air source heat pumps (ccASHPs). But there's one big problem - wide-scale adoption of ccASHPs will dramatically increase winter peak electricity demand, even with the highest efficiency ccASHP products. Furthermore, cold climate space heating loads will drive unprecedented electric system peaks during the lowest periods of renewable generation and are likely to overwhelm existing distribution systems. This scenario is avoidable by coupling electrification with building envelope upgrades to reduce peak heating loads. This paper presents a model, built from home energy audit and research data sets, that quantifies the above challenges. Results demonstrate how weatherization efforts coupled with additional high-performance envelope upgrade measures can prepare the building stock for electrification and show the benefit these measures can bring to future utility operations. Much of this envelope upgrade work is cost-effective, according to conservative cost-benefit testing and program successes to date, and is coupled with substantial non-energy benefits. However, persistent market barriers have made scaling of envelope retrofit work challenging for decades, suggesting additional policy support is required. Lessons learned from previous policy experience, combined with new technology and administrative support, create exciting potential for this decarbonization climate solution.
This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.
Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.
The building stock in the United States (U.S.) varies significantly as a function of several macro variables such as: climate, building type, vintage, and density. These variables change across the U.S. and can also significantly impact energy usage of the individual buildings and overall stock. For example, the square foot density and building type varies by several orders of magnitude from Manhattan to the eastern plains of Colorado. The diversity in energy use of the building stock of different areas of the U.S. is significant, and as a result, analyses that require localized results need to consider the relevant geography and the current makeup of the building stock. This document discusses the development and implementation of a stock clustering algorithm that produces a technically rigorous, consistent, and repeatable collection of geographies which are used as the basis for localized analysis. This framework considers the impact of built environment density, diversity, and climate in creating groupings of counties that create a far more nuanced analysis framework than national averages. Clustering of counties together represents a similarity of building characteristics and climate zone.
We present unprecedented datasets of current and future projected weather files for building simulations in 15 major cities distributed across 10 climate zones worldwide. The datasets include ambient air temperature, relative humidity, atmospheric pressure, direct and diffuse solar irradiance, and wind speed at hourly resolution, which are essential climate elements needed to undertake building simulations. The datasets contain typical and extreme weather years in the EnergyPlus weather file (EPW) format and multiyear projections in comma-separated value (CSV) format for three periods: historical (2001–2020), future mid-term (2041–2060), and future long-term (2081–2100). The datasets were generated from projections of one regional climate model, which were bias-corrected using multiyear observational data for each city. The methodology used makes the datasets among the first to incorporate complex changes in the future climate for the frequency, duration, and magnitude of extreme temperatures. These datasets, created within the IEA EBC Annex 80 “Resilient Cooling for Buildings”, are ready to be used for different types of building adaptation and resilience studies to climate change and heatwaves.
Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.
Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.
Coastal wetlands, including seagrass meadows, emergent marshes, mangroves, and temperate tidal swamps, can efficiently sequester and store large quantities of sediment organic carbon (SOC). However, SOC stocks may vary by ecosystem type and along environmental or climate gradients at different scales. Quantifying such variability is needed to improve blue carbon accounting, conservation effectiveness, and restoration planning. We analyzed SOC stocks in 1,284 sediment cores along >6,500 km of the Pacific coast of North America that included large environmental gradients and multiple ecosystem types. Tidal wetlands with woody vegetation (mangroves and swamps) had the highest mean stocks to 1 m depth (357 and 355 Mg ha −1 , respectively), 45% higher than marshes (245 Mg ha −1 ), and more than 500% higher than seagrass (68 Mg ha −1 ). Unvegetated tideflats, though not often considered a blue carbon ecosystem, had noteworthy stocks (148 Mg ha −1 ). Stocks increased with tidal elevation and with fine (<63 μm) sediment content in several ecosystems. Stocks also varied by dominant plant species within individual ecosystem types. At larger scales, marsh stocks were lowest in the Sonoran Desert region of Mexico, and swamp stocks differed among climate zones; otherwise stocks showed little correlation with ecoregion or latitude. More variability in SOC occurred among ecosystem types, and at smaller spatial scales (such as individual estuaries), than across regional climate gradients. These patterns can inform coastal conservation and restoration priorities across scales where preserving stored carbon and enhancing sequestration helps avert greenhouse gas emissions and maintains other vital ecosystem services.