Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Chandra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Chandra X-Ray Observatory: An Overview

The Chandra X-Ray Observatory was launched early in the morning of July 23, 1999, by the Space Shuttle Columbia. The Shuttle launch was only the first step in placing NASA's latest great observatory into orbit. After release from the cargo bay, the Inertial Upper Stage performed two firings and separated from the observatory as planned. Finally, after five firings of Chandra's own Integral Propulsion System - the last of which took place 15 days after the initial launch - the observatory was placed in its highly elliptical orbit of 140,000 km apogee and 10,000 km perigee. After Observatory activation, the first x-rays focussed by the telescope were observed on 1999, August 12. Beginning with this initial observation one could conclude that the telescope had survived the launch environment and was operating as expected. The month following the opening of the sunshade door was spent adjusting the focus for each set of instrument configurations, determining the optical axis, calibrating the star camera, establishing the relative response functions, determining the energy scale(s), and performing a series of "publicity" images. Each observation proved to be far more revealing than was expected. Preliminary results will be presented and the status of the instrumentation on the observatory will be discussed.

Weisskopf, Martin C.

Measurements with the Chandra Flight Contamination Monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements, which place limits on the change in mirror-detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces.

Elsner, R. E.

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.

Observed On-Orbit Background of the ACIS Detector on the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic X-rays. The ACIS instrument contains 8 Front-Illuminated (FI) CCDs and 2 Back-Illuminated (BI) CCDs. The FI and BI CCD)s exhibit dramatically different responses to enhancements in the particle flux. The F1 CCDs show relatively little increase in the overall count rate, typical increases are 1 - 3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The duration of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the power-law. The events produce morphologies which are similar to cosmic X-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, P. P.

The Chandra X-Ray Observatory Overview

The Chandra X-Ray Observatory was launched early in the morning of July 23, 1999 by the Space Shuttle Columbia. The Shuttle launch was only the first step in placing NASA's latest great observatory into orbit. After release from the cargo bay, the Inertial Upper Stage performed two firings and separated from the observatory as planned. Finally, after five firings of Chandra's own Integral Propulsion System - the last of which took place 15 days after the initial launch - the observatory was placed in its highly elliptical orbit of 140,000 km apogee and 10,000 km perigee. After Observatory activation, the first x-rays focused by the telescope were observed on August 12, 1999. Beginning with this initial observation one could conclude that the telescope had survived the launch environment and was operating as expected. The month following the opening of the sunshade door was spent adjusting the focus for each set of instrument configurations, determining the optical axis, calibrating the star camera, establishing the relative response functions, determining the energy scale(s), and performing a series of "publicity" images. Each observation proved to be far more revealing than was expected. Preliminary results will be presented and the status of the instrumentation on the observatory will be discussed.

Weisskopf, Martin C.

Chandra Observations of Starburst Galaxies

We present early X-ray results from Chandra for two starburst galaxies, M82 and NGC3256, obtained using AXAF CCD Imaging Spectrometer (ACIS-I) and the HRC. For M82 the arcsecond spatial resolution enables us to separate the point source component from the extended emission for the first time. Astrometry reveals that most of the X-ray sources are not coincident with the family of compact radio sources believed to be Super Nova Remnants (SNRs). In addition, based on three epoch Chandra observations, several of the X-ray sources are clearly variable indicating that they are binaries. When we deconvolve the extended and point source components detected in the hard X-ray band, we find that 50 percent arises from the extended component. This fact, together with its morphology, constrains the various models proposed to explain the hard X-ray emission. For NGC3256 we resolve two closely separated nuclei. These new data support a pure starburst origin for the total X-ray emission rather than a composite AGN/starburst, thereby making NGC3256 one of the most X-ray luminous starburst galaxies known.

Prestwich, Andrea

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.

The High Resolution Chandra X-Ray Spectrum of 3C273

The bright quasar 3C273 was observed by Chandra in January 2000 for 120 ksec as a calibration target. It was observed with all detector- plus-grating combinations (ACIS+HETG, ACIS+LETG, and HRC+LETG) yielding an X-ray spectrum across the entire 0.1-10 keV band with unprecedented spectral resolution. At about 10 arcsec from the nucleus, an X-ray jet is also clearly visible and resolved in the Oth order images. While the jet is much fainter than the nuclear source, the Chandra spatial resolution allows, for the first time, spectral analysis of both components separately. We will present detailed spectral analysis with particular emphasis on possible absorption features and comparison with simultaneous BeppoSAX data.

Fruscione, Antonella

Demonstrating the Power of Chandra High Resolution Spectroscopy Plasma Diagnostics

The Chandra spectrometers can resolve spectroscopic features that can be used to diagnose the state of emitting plasma. Based on high resolution Chandra High Energy Transmission Grating (HETG) calibration observations of the active RS CVn-type Binary V711 Tau (HR1099), we determine for the first time the plasma density at a range of coronal temperatures for this type of object. The results are used to constrain coronal structural models and build a picture of the change in coronal structure from stars of solar-like activity to the most active RS CVn-type binaries.

Drake, Jeremy

Clusters with Chandra

Cluster mass distributions were suggested to be universal based on previous X-ray observations and numerical simulations. Chandra observations are able to test this universal distribution. We will present results of Chandra observations which suggest that the universal mass profile is correct.

Forman, William R.

Results of a Deep Chandra Observation of the Crab Nebula and Pulsar

The Crab Nebula and pulsar were observed for a total of 150 ksec with the LETG/HRC-S combination aboard the Chandra X-Ray Observatory in 2000, January. One of the principal aims of the experiment was to study the emission of from the pulsar as a function of pulse phase. Neutron stars are believed to be formed with core temperatures of 10(exp 11). As the pulsar is the youngest known neutron star with an age of only 940 yrs, it should be possible to observe thermal emission from the hot stellar surface which in turn constrains equations of state. The pulsar, on the other hand, is a powerful non-thermal emitter, powering an X-ray bright synchrotron nebula which, in Einstein and ROSAT observations, overshadowed the fainter thermal surface emission. Making use of the high angular resolution provided by Chandra we were able to detect X-rays from the Crab-pulsar at all pulse phases. We discuss whether this detection is indeed of thermal emission or of a faint synchrotron component of the pulsed emission from the magnetosphere. We further report on dynamical effects observed in the pulsar-wind outflow and the analysis of the LETG spectral data, especially near the oxygen edge. The results of the spectral analysis has interesting implications for the composition of the interstellar medium.

Weisskopf, M. C.

Initial Results From The Chandra High Energy Transmission Grating Spectrometer

The High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory provides spectral resolving powers of 200-1000 over the range 0.4-8.0 keV (1.5-30 A) with effective area of 2-200 square centimeters. Initial observations during the activation and calibration phases of the mission show that the HETGS is performing as predicted prior to Chandra launch. The talk presented very preliminary results that illustrate the power of the HETGS for performing detailed studies of a wide range of celestial sources, including plasma diagnostics. This written version gives a brief summary of that talk with examples of preliminary spectra of Capella, the Crab pulsar, SS433 and the SNR E0102-72.

Canizares, C. R.

Results of a Deep Chandra Observation of the Crab Nebula and Pulsar

The Crab Nebula and pulsar were observed for a total of 150 ksec with the LETG/HRC-S combination aboard the Chandra X-Ray Observatory in 2000, January and February. One of the principal aims of the experiment was to study the emission from the pulsar as a function of pulse phase. Neutron stars are believed to be formed with core temperatures of 10(exp 11) K. As the pulsar is the best studied of the young known neutron stars with an age of only 940 yrs, it should be possible to observe thermal emission from the hot stellar surface which in turn constrains equations of state. The pulsar, on the other hand, is a powerful non-thermal emitter, powering an X-ray bright synchrotron nebula which, in Einstein and ROSAT observations, overshadowed the fainter thermal surface emission. Making use of the high angular resolution provided by Chandra we were able to detect X-rays from the Crab-pulsar at all pulse phases. We discuss whether this detection is indeed of thermal emission or of a faint synchrotron component of the pulsed emission from the magnetosphere. We further comment on dynamical effects observed in the pulsar-wind outflow and the analysis of the LETG spectral data, especially near the oxygen edge.

Weisskopf, M. C.

Chandra HRC Observations of X-rays from Jupiter's Aurora

In support of the Cassini flyby of Jupiter, the Chandra HRC was used to observe the Jovian system for 10 hours on December 18, 2000, from 10-20 UT. Analysis of the data has yielded the following results: 1) a strong, high-latitude northern auroral "hot spot." which is relatively fixed near 60-70 degrees north latitude and 160-180 degrees system III longitude, and which pulsates with a period of about 40 minutes and has an average emitted power of about 2 GW; 2) relatively uniform low-latitude emissions, with a total power output of about 5 GW; 3) a southern aurora which shows both high latitude emissions and lower-latitude emissions originating in the L=8-12 region just outside the Io Plasma Torus, with an emitted power of about 1 GW. These power estimates are based on an assumed emission wavelength of 574 eV (corresponding to a bright emission line of OVII ions), and are subject to revision as Chandra ACIS spectra of Jupiter are analyzed further. We will present these and other results from this unique data set.

Gladstone, G. R.

Two Years of Chandra Observations: Neutron Stars and Pulsars with Emphasis on the Pulsar in the Crab Nebula

The Chandra X-Ray Observatory is entering its third year of operation. The Observatory, the premiere x-ray telescope for high-resolution imaging, has exceeded all expectations. The sub-arc second angular resolution together with other instrumental capabilities has allowed for new insights into the understanding of compact x-ray emitting objects including neutron stars and pulsars. We briefly review the Chandra Program and the first two years of observation with emphasis on these interesting objects. We detail the results of our observations of the pulsar in the Crab Nebula including the first continuum spectrum that is virtually uncontaminated by any dust-scattered radiation.

Weisskopf, Martin C.

Chandra Discovery of Luminous Supersoft X-Ray Sources in M81

A Chandra ACIS-S imaging observation of the nearby galaxy M81 (NGC 3031) reveals 9 luminous soft X-ray sources. The local environments, X-ray spectral properties, and X-ray light curves of the sources are presented and discussed in the context of prevailing physical models for supersoft sources. It is shown that the sample falls within expectations based on population synthesis models taken from the literature though the high observed luminosities (L approx.2e36 to approx.3e38 ergs in the 0.2--2.0-keV band) and equivalent blackbody temperatures (T approx.40 to 80 eV) place the brightest detected M81 objects at the high luminosity end of the class of supersoft sources defined by previous ROSAT and Einstein studies of nearby galaxies. This is interpreted as a natural consequence of the higher sensitivity of Chandra to hotter and more luminous systems. Most of the sources can be explained as canonical supersoft sources, secreting white dwarfs powered by steady surface nuclear burning, with X-ray spectra well-fit by hot white dwarf local thermodynamic equilibrium atmosphere models. An exceptionally bright source is scrutinized in greater detail as its estimated barometric luminosity, L approx. 1.5e39 ergs, greatly exceeds theoretical estimates for supersoft sources. This source may be beyond the stability limit and undergoing a phase of mass outflow under extreme conditions. Alternatively, a model in which the observed X-ray spectrum arises from an accretion disk around a blacklists of mass approx.1200/sqrt(cosi) solar masses (viewed at an inclination angle 1) cannot be excluded.

Swartz, Douglas A.

Chandra X-ray Observations of the Spiral Galaxy M81

A Chandra X-Ray Observatory ACIS-S (Advanced X-ray Astrophysics Facility (Chandra) CCD (Charge Coupled Device) Imaging Spectrometer) imaging observation is used to study the population of X-ray sources in the nearby Sab galaxy M81 (NGC 3031). A total of 177 sources are detected with 124 located within the D25 isophote to a limiting X-ray luminosity of 3e36 ergs/cm(exp 2)/s. Source positions, count rates, luminosities in the 0.3-8.0 keV band, limiting optical magnitudes, and potential counterpart identifications are tabulated. Spectral and timing analysis of the 36 brightest sources are reported including the low luminosity active galactic nucleus, SN 1993J, and the Einstein discovered ultraluminous X-ray source X6.

Swartz, Douglas A.

Chandra Observations of Neutron Stars: An Overview

We present a brief review of Chandra observations of neutron stars, with a concentration on neutron stars in supernova remnants. The early Chandra results clearly demonstrate how critical the angular resolution has been in order to separate the neutron star emission from the surrounding nebulosity.

Weisskopf, M. C.