Packaging printed circuit boards: A production application of interactive graphics

The structure and use of an Interactive Graphics Packaging Program (IGPP), conceived to apply computer graphics to the design of packaging electronic circuits onto printed circuit boards (PCB), were described. The intent was to combine the data storage and manipulative power of the computer with the imaginative, intuitive power of a human designer. The hardware includes a CDC 6400 computer and two CDC 777 terminals with CRT screens, light pens, and keyboards. The program is written in FORTRAN 4 extended with the exception of a few functions coded in COMPASS (assembly language). The IGPP performs four major functions for the designer: (1) data input and display, (2) component placement (automatic or manual), (3) conductor path routing (automatic or manual), and (4) data output. The most complex PCB packaged to date measured 16.5 cm by 19 cm and contained 380 components, two layers of ground planes and four layers of conductors mixed with ground planes.

Perrill, W. A.↗

Automatic documentation system extension to multi-manufacturers' computers and to measure, improve, and predict software reliability

The DOMONIC system has been modified to run on the Univac 1108 and the CDC 6600 as well as the IBM 370 computer system. The DOMONIC monitor system has been implemented to gather data which can be used to optimize the DOMONIC system and to predict the reliability of software developed using DOMONIC. The areas of quality metrics, error characterization, program complexity, program testing, validation and verification are analyzed. A software reliability model for estimating program completion levels and one on which to base system acceptance have been developed. The DAVE system which performs flow analysis and error detection has been converted from the University of Colorado CDC 6400/6600 computer to the IBM 360/370 computer system for use with the DOMONIC system.

Simmons, D. B.↗

Flexstab on the IBM 360

FLEXSTAB, an array of computer programs developed on CDC equipment, has been converted to operate on the IBM 360 computation system. Instructions for installing, validating, and operating FLEXSTAB on the IBM 360 are included. Hardware requirements are itemized and supplemental materials describe JCL sequences, the CDC to IBM conversion, the input output subprograms, and the interprogram data flow.

Pyle, R. S.↗

A computer program for the identification of helicopter impulsive noise sources

A computer program is presented for calculating the source location of implusive noise in helicopters. The program (INSL) is written in FORTRAN for the CDC 7600 computer. Inputs are the rotor operating conditions and the time intervals (T) between rotor 1/rev index and impulsive noises as measured by different microphones. The outputs are the possible noise source locations in terms of rotor radial and azimuthal coordinates. Typical computer time for a run of six microphone measurements is 1.5 sec, and the cost is about 12 cents for the CDC 7600.

Lee, A.↗

Study of the NASTRAN input/output systems

The basic characteristics of the NASTRAN level 16 I/O subsystem are presented with particular reference to blocking/deblocking aspects, I/O methods used on the IBM, CDC, and UNIVAC machines, definition of basic NASTRAN I/O control tables, and portability of parts of the I/O subsystem to other programs outside the NASTRAN environment are included. An explanation of the IBM primary, secondary, and tertiary files defined by the data definition (DD) cards in the NASTRAN JCL procedure. The explanation is intended to enlighten users as to the purpose of these DD cards, how they relate to one another, and why there are no similar type definition cards required on the CDC and UNIVAC versions. Enhancements designed to increase overall efficiency and decrease core requirements are also recommended.

Brown, W. K.↗

Basic linear algebra subprograms for FORTRAN usage

A package of 38 low level subprograms for many of the basic operations of numerical linear algebra is presented. The package is intended to be used with FORTRAN. The operations in the package are dot products, elementary vector operations, Givens transformations, vector copy and swap, vector norms, vector scaling, and the indices of components of largest magnitude. The subprograms and a test driver are available in portable FORTRAN. Versions of the subprograms are also provided in assembly language for the IBM 360/67, the CDC 6600 and CDC 7600, and the Univac 1108.

Lawson, C. L.↗

A computer program for the generation of logic networks from task chart data

The Network Generation Program (NETGEN), which creates logic networks from task chart data is presented. NETGEN is written in CDC FORTRAN IV (Extended) and runs in a batch mode on the CDC 6000 and CYBER 170 series computers. Data is input via a two-card format and contains information regarding the specific tasks in a project. From this data, NETGEN constructs a logic network of related activities with each activity having unique predecessor and successor nodes, activity duration, descriptions, etc. NETGEN then prepares this data on two files that can be used in the Project Planning Analysis and Reporting System Batch Network Scheduling program and the EZPERT graphics program.

Herbert, H. E.↗

Experience with a vectorized general circulation weather model on Star-100

A version of an atmospheric general circulation model was vectorized to run on a CDC STAR 100. The numerical model was coded and run in two different vector languages, CDC and LRLTRAN. A factor of 10 speed improvement over an IBM 360/95 was realized. Efficient use of the STAR machine required some redesigning of algorithms and logic. This precludes the application of vectorizing compilers on the original scalar code to achieve the same results. Vector languages permit a more natural and efficient formulation for such numerical codes.

Soll, D. B.↗

NECAP - NASA's Energy Cost Analysis Program. Operations manual

The use of the NASA'S ENERGY COST ANALYSIS PROGRAM (NECAP) is described. Supplementary information on new capabilities and program options is also provided. The Control Data Corporation (CDC) NETWORK OPERATING SYSTEM (NOS) is discussed. The basic CDC NOS instructions which are required to successfully operate NECAP are provided.

Miner, D. L.↗

Steady viscous flow past a circular cylinder

Viscous flow past a circular cylinder becomes unstable around Reynolds number Re = 40. With a numerical technique based on Newton's method and made possible by the use of a supercomputer, steady (but unstable) solutions have been calculated up to Re = 400. It is found that the wake continues to grow in length approximately linearly with Re. However, in conflict with available asymptotic predictions, the width starts to increase very rapidly around Re = 300. All numerical calculations have been performed on the CDC CYBER 205 at the CDC Service Center in Arden Hills, Minnesota.

Fornberg, B.↗

PAN AIR: A computer program for predicting subsonic or supersonic linear potential flows about arbitrary configurations using a higher order panel method. Volume 4: Maintenance document (version 1.1)

The Maintenance Document is a guide to the PAN AIR software system, a system which computes the subsonic or supersonic linear potential flow about a body of nearly arbitrary shape, using a higher order panel method. The document describes the over-all system and each program module of the system. Sufficient detail is given for program maintenance, updating and modification. It is assumed that the reader is familiar with programming and CDC (Control Data Corporation) computer systems. The PAN AIR system was written in FORTRAN 4 language except for a few COMPASS language subroutines which exist in the PAN AIR library. Structured programming techniques were used to provide code documentation and maintainability. The operating systems accommodated are NOS 1.2, NOS/BE and SCOPE 2.1.3 on the CDC 6600, 7600 and Cyber 175 computing systems. The system is comprised of a data management system, a program library, an execution control module and nine separate FORTRAN technical modules. Each module calculates part of the posed PAN AIR problem. The data base manager is used to communicate between modules and within modules. The technical modules must be run in a prescribed fashion for each PAN AIR problem. In order to ease the problem of supplying the many JCL cards required to execute the modules, a separate module called MEC (Module Execution Control) was created to automatically supply most of the JCL cards. In addition to the MEC generated JCL, there is an additional set of user supplied JCL cards to initiate the JCL sequence stored on the system.

Baruah, P. K.↗

Computer program for prediction of capture maneuver probability for an on-off reaction controlled upper stage

A FORTRAN coded computer program which computes the capture transient of a launch vehicle upper stage at the ignition and/or separation event is presented. It is for a single degree-of-freedom on-off reaction jet attitude control system. The Monte Carlo method is used to determine the statistical value of key parameters at the outcome of the event. Aerodynamic and booster induced disturbances, vehicle and control system characteristics, and initial conditions are treated as random variables. By appropriate selection of input data pitch, yaw and roll axes can be analyzed. Transient response of a single deterministic case can be computed. The program is currently set up on a CDC CYBER 175 computer system but is compatible with ANSI FORTRAN computer language. This routine has been used over the past fifteen (15) years for the SCOUT Launch Vehicle and has been run on RECOMP III, IBM 7090, IBM 360/370, CDC6600 and CDC CYBER 175 computers with little modification.

Knauber, R. N.↗

Computer program for post-flight evaluation of a launch vehicle upper-stage on-off reaction control system

This report describes a FORTRAN IV coded computer program for post-flight evaluation of a launch vehicle upper stage on-off reaction control system. Aerodynamic and thrust misalignment disturbances are computed as well as the total disturbing moments in pitch, yaw, and roll. Effective thrust misalignment angle time histories of the rocket booster motor are calculated. Disturbing moments are integrated and used to estimate the required control system total inpulse. Effective control system specific inpulse is computed for the boost and coast phases using measured control fuel useage. This method has been used for more than fifteen years for analyzing the NASA Scout launch vehicle second and third-stage reaction control system performance. The computer program is set up in FORTRAN IV for a CDC CYBER 175 system. With slight modification it can be used on other machines having a FORTRAN compiler. The program has optional CALCOMP plotting output. With this option the program requires 19K words of memory and has 786 cards. Running time on a CDC CYBER 175 system is less than three (3) seconds for a typical problem.

Knauber, R. N.↗

Communicable Disease Research

The COSMIC program FITLOS is used regularly by the Centers for Disease Control (CDC), for analyzing data from radioimmunoassays, which involve testing human body substances to provide information on how deficits or excesses of those substances affect a body's ability to ward off disease. A liquid scintillation counter's data is analyzed by the FITLOS program. FITLOS data, then aids in establishing reference methods for hospitals and other health laboratories in their radioimmunoassays. CDC's use of this program enabled them to avoid the cost of designing and developing a new program.

Source record↗

Environmental Public Health Surveillance for Exposure to Respiratory Health Hazards: A Joint NASA/CDC Project to Use Remote Sensing Data for Estimating Airborne Particulate Matter Over the Atlanta, Georgia Metropolitan Area

As part of the National Environmental Public Health Tracking Network (EPHTN) the National Center for Environmental Health (NCEH) at the Centers for Disease Control and Prevention (CDC) is leading a project called Health and Environment Linked for Information Exchange (HELiX-Atlanta). The goal of developing the National Environmental Public Health Tracking Network is to improve the health of communities. Currently, few systems exist at the state or national level to concurrently track many of the exposures and health effects that might be associated with environmental hazards. An additional challenge is estimating exposure to environmental hazards such as particulate matter whose aerodynamic diameter is less than or equal to 2.5 micrometers (PM2.5). HELIX-Atlanta's goal is to examine the feasibility of building an integrated electronic health and environmental data network in five counties of Metropolitan Atlanta, GA. NASA Marshall Space Flight Center (NASA/MSFC) is collaborating with CDC to combine NASA earth science satellite observations related to air quality and environmental monitoring data to model surface estimates of PM2.5 concentrations that can be linked with clinic visits for asthma. While use of the Air Quality System (AQS) PM2.5 data alone could meet HELIX-Atlanta specifications, there are only five AQS sites in the Atlanta area, thus the spatial coverage is not ideal. We are using NASA Moderate Resolution Imaging Spectroradiometer (MODIS) satellite Aerosol Optical Depth (AOD) data for estimating daily ground level PM2.5 at 10 km resolution over the metropolitan Atlanta area supplementing the AQS ground observations and filling their spatial and temporal gaps.

Quattrochi, Dale A.↗

The Use of GIS and Remotely Sensed Data in Environmental Public Health Tracking (EPHT): The HELIX-Atlanta Experience

As part of the National Environmental Public Health Tracking Network (EPHTN), the National Center for Environmental Health (NCEH) at the Centers for Disease Control and Prevention (CDC) is leading a project in collaboration with the NASA Marshall Space Flight Center (NASA/MSFC) called Health and Environment Linked for Information Exchange (HELIX-Atlanta). HELIX-Atlanta's goal is to examine the feasibility of building an integrated electronic health and environmental data network in five counties of metropolitan Atlanta, GA. Under HELIX-Atlanta, pilot projects are being conducted to develop methods to characterize exposure; link health and environmental data; analyze the relationship between health and environmental factors; and communicate findings. There is evidence in the research literature that asthmatic persons are at increased risk of developing asthma exacerbations with exposure to environmental factors, including PM(sub 2.5). Thus, HELIX-Atlanta is focusing on methods for characterizing population exposure to PM(sub 2.5) for the Atlanta metropolitan area that could be used in ongoing surveillance. NASA/MSFC is working with CDC to combine NASA earth science satellite observations related to air quality and environmental monitoring data to model surface estimates of fine particulate matter (PM(sub 2.5)) concentrations in a Geographic Information System (GIS) that can be linked with clinic visits for asthma on the aggregated grid level as well as the individual level at the geographic locations of the patients' residences.

Al-Hamdan, Mohammad Z.↗

Exploiting Satellite Remote-Sensing Data in Fine Particulate Matter Characterization for Serving the Environmental Public Health Tracking Network (EPHTN): The HELIX-Atlanta Experience and NPOESS Implications

As part of the U.S. National Environmental Public Health Tracking Network (EPHTN), the National Center for Environmental Health (NCEH) at the U.S. Centers for Disease Control and Prevention (CDC) led a project in collaboration with the National Aeronautics and Space Administration (NASA) Marshall Space Flight Center (MSFC) called Health and Environment Linked for Information Exchange (HELIX-Atlanta). Under HELIX-Atlanta, pilot projects were conducted to develop methods to better characterize exposure; link health and environmental datasets; and analyze spatial/temporal relationships. This paper describes and demonstrates different techniques for surfacing daily environmental hazards data of particulate matter with aerodynamic diameter less than or equal to 2.5 micrometers (PM(sub 2.5) for the purpose of integrating respiratory health and environmental data for the CDC's pilot study of HELIX-Atlanta. It describes a methodology for estimating ground-level continuous PM(sub 2.5) concentrations using spatial surfacing techniques and leveraging NASA Moderate Resolution Imaging Spectrometer (MODIS) data to complement the U.S. Environmental Protection Agency (EPA) ground observation data. The study used measurements of ambient PM(sub 2.5) from the EPA database for the year 2003 as well as PM(sub 2.5) estimates derived from NASA's MODIS data. Hazard data have been processed to derive the surrogate exposure PM(sub 2.5) estimates. The paper has shown that merging MODIS remote sensing data with surface observations of PM(sub 2.5), may provide a more complete daily representation of PM(sub 2.5), than either data set alone would allow, and can reduce the errors in the PM(sub 2.5) estimated surfaces. Future work in this area should focus on combining MODIS column measurements with profile information provided by satellites like the National Polar-orbiting Operational Environmental Satellite System (NPOESS). The Visible Infrared Imager/Radiometer Suite (VIIRS) and the Aerosol Polarimeter Sensor (APS) NPOESS sensors will provide first-order information on aerosol particle size and are anticipated to provide information on aerosol products at higher resolution and accuracy than MODIS. Use of the NPOESS remote sensing data should result in more robust remotely sensed data that can be coupled with the methods discussed in this paper to generate surface concentrations of PM(2.5) for linkage with health data in Environmental Public Health Tracking.

Al-Hamdan, Mohammad Z.↗