Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CarbonSAFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Computed Tomography Scanning and Geophysical Measurements of the Wabash No.1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize Mt. Simon core from the Wabash CarbonSAFE project, Wabash No. 1 well. The primary impetus of the work in this report is a collaboration between NETL Research and Innovation Center and the Illinois State Geological Survey at the Prairie Research Institute, University of Illinois Urbana-Champaign in Champaign, Illinois. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wabash-no-1-well. The Wabash No. 1 well was drilled as part of a U.S. Department of Energy (DOE) funded Carbon Storage Assurance Facility Enterprise field project to assess the feasibility of developing a commercial-scale geological storage complex at the Wabash Valley Resources Integrated Gasification Combined Cycle plant near Terre Haute, Indiana. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in fine-grained structures; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy-related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Wellington 1-32 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE), National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Wellington 1-32 well (API 15-191-22591), a small-scale field test site in the Wellington Field, in Sumner County, Kansas. Wellington 1-32 was drilled in association with the Kansas Geologic Survey’s (KGS) Phase I pre-feasibility study under the DOE-NETL Carbon Storage Assurance Facility Enterprise (CarbonSAFE) program, with the goal of utilizing the Arbuckle Group as a reservoir for CO 2 storage and the potential for stacked reservoir enhanced oil recovery from Mississippian reservoirs.

58 GEOSCIENCES↗

Computed Tomography Scanning and Petrophysical Measurements of the Lively Grove #1 Well Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Lively Grove #1 Well (API 121892494700), drilled near Marissa, Washington County, Illinois. Core from the well was obtained as part of the Illinois Storage Corridor’s Carbon Storage Assurance Facility Enterprise (CarbonSAFE) project (DE FE0031892). The primary impetus of this work was to capture a detailed digital representation of the core from the Lively Grove #1 Well. The collaboration between the U.S. Department of Energy’s (DOE) NETL and the Illinois State Geological Survey (ISGS) enables other research entities to access information about this potential carbon storage location and Cambro-Ordovician Storage Complex formations of the Illinois Basin. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner-acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; with the resulting macro- and micro-descriptions relevant to many subsurface energy related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Flow Quantification Through Potential CO2 Storage Formations

Multiscale Analyses with CT Scanning<p>How NETL Research and Innovation Center Core Flow and imaging lab is assisting CarbonSAFE and FECM-funded field efforts to meet FECM's Carbon Management goals is described in this presentation.</p>

Crandall, Dustin↗

Screening Assessment of Prospective CO 2 Storage Resource Potential in Saline Carbonate Systems, Central North Dakota Region

Conference presentation at 2023 Rocky Mountain Section-American Association of Petroleum Geologists (RMS-AAPG) Annual Meeting, Bismarck, ND, June 4–6, 2023. As part of the U.S. Department of Energy-funded North Dakota CarbonSAFE Phase III effort, a screening-level assessment was conducted over central North Dakota, including McLean, Mercer, and Morton Counties, to determine if viable CO 2 storage resource potential exists within carbonate saline reservoirs. Published literature and data from 173 wells were used in the study. The study focused on identifying carbonate saline reservoirs and suitable confining zones for CO 2 storage, with emphasis on three key questions: 1) are the carbonate saline reservoirs viable for CO 2 storage? 2) what is their range of storage resource potential? and 3) what are the main elements driving uncertainty and risk of potential capacity and containment?

20 FOSSIL-FUELED POWER PLANTS↗

Colorado (Pueblo) Regional DAC Hub TA-1: Feasibility (Phase 0a) (Final Technical Report)

This project supports the U.S. Department of Energy's (DOE) mission to reduce the environmental and climate impacts of fossil fuels and industrial processes, contributing to the goal of achieving net-zero emissions across the U.S. economy. The primary objective is to conduct a feasibility study for a Regional Direct Air Capture (DAC) Hub in the Southern Colorado region, northeast of Pueblo. The geographic construct of this hub is based on the Denver-Julesburg Basin – a geological area where a significant number of geological storage studies have been conducted (See Figure 1). The project will leverage the work of Project Eos, a CarbonSAFE Phase III study led by the Colorado School of Mines and CarbonAmerica. The DAC Hub aims to capture, store, and/or utilize at least 1,000,000 tonnes of CO 2 from the atmosphere annually. To achieve this, the project team is designing a system with an initial capacity of 100,000 tonnes per year. This feasibility-stage project will formulate the Regional DAC Hub concept and team to conduct the relevant analysis, networking and community stakeholder engagement necessary to advance the project to the design stage.

42 ENGINEERING↗

One Earth Energy FEED Process Design Basis

This report establishes the process design basis for the front-end engineering design (FEED) of a carbon capture and injection facility at One Earth Energy's (OEE) ethanol production plant in Gibson City, Illinois, developed as part of the Illinois Storage Corridor CarbonSAFE Phase III project. The facility is designed to compress and dehydrate up to approximately 458,000 metric tonnes of CO 2 per year, sourced directly from OEE's ethanol fermenters, for permanent injection into a saline aquifer approximately four miles from the plant. At normal operating conditions, the system will process 1,290 metric tonnes of CO 2 per day, assuming 355 operating days per year and an ethanol production rate of 160 million gallons per year. The proposed process trains a multistage centrifugal blower with a five-stage reciprocating compressor, delivering CO 2 to the injection wellhead at up to 1,500 psig. Triethylene glycol (TEG) dehydration, applied after the fourth compression stage, reduces water content to a target of 10 lb/MMscf, well within the 30 lb/MMscf injection limit. Beyond dehydration, no additional treatment is required; trace impurities including oxygen and nitrogen will remain in the injected stream. Key design considerations include the absence of spare cooling tower capacity at the site, necessitating new cooling infrastructure, and the need for a new electrical substation to support large motor loads. The facility is designed for continuous, largely unattended operation, monitored around the clock by existing OEE operations staff. This document serves as the foundational reference for all subsequent detailed engineering activities associated with the OEE CO 2 injection facility.

01 COAL, LIGNITE, AND PEAT↗

One Earth Energy Static and Dynamic Reservoir Modeling

This report presents the static and dynamic reservoir modeling conducted for the CarbonSAFE Phase III Illinois Storage Corridor project to assess the feasibility of commercial-scale CO 2 storage in the Mt. Simon Sandstone at the One Earth Energy (OEE) site in McLean County, Illinois. Three-dimensional geocellular models of the Mt. Simon storage complex were developed in Petrel ® by integrating petrophysical log data, core analyses, and seismic surveys from the OEE #1 stratigraphic test well and two nearby wells, with multiple model versions created as new data became available. Dynamic reservoir simulations, performed using Landmark's Nexus software, progressed through three phases (preliminary, sensitivity, and UIC Class VI permit studies) evaluating injection scenarios across varying rates, well orientations, permeability models, and multi-well configurations. Results demonstrate that commercial-scale storage is feasible: three injection wells spaced approximately one mile apart can store a total of 90 million tonnes of CO 2 over 20 years, producing a combined plume with an equivalent radius of 3.2 miles and a maximum pressure-front-defined Area of Review of 178 mi 2 at the end of injection that diminishes to 34 mi 2 after 50 years of post-injection monitoring. Sensitivity analyses indicate that a 20% change in porosity or permeability yields approximately a 7% change in AoR radius, and that perforating the high-permeability arkosic zone minimizes the pressure front compared to injection in the upper Mt. Simon Sandstone.

09 BIOMASS FUELS↗

Qualitative Risk Assessment of Legacy Wells within the Estimated Prairie State Generating Company Area of Review

This report details the digitization of a legacy wellbore database, including data processing assumptions, parameter estimation, and risk assessment methodology. The database, comprising 6,454 documents, was provided by ISGS. It includes valuable data from the Prairie State Generating Company (PSGC) and One Earth Energy (OEE) sites of the CarbonSAFE Phase III – Illinois Storage Corridor project. The report focuses on wells within a 15-mile radius from the Lively Grove #1 (LG#1) well at PSGC site, evaluating subsurface conditions and potential risks. A total of 4,386 wellbores within 15 miles of the LG#1 well were filtered based on depth and formation codes. LG#1 is the stratigraphic well at the PSGC site drilled in 2021. Ninety-four (94) wells penetrating the Maquoketa Shale Group (the primary confining unit) within the estimated area-of-review (AoR) for the PSGC site were evaluated using a qualitative risk assessment (QRA) methodology. The QRA developed by Arbad et al. 2022 focuses on legacy wells within the AoR and categorizes them based on well construction details. The QRA identifies wells that need immediate attention by categorizing them based on penetration depth and protection. Wells within the AoR were categorized into nine groups based on penetrations and protections. These categories range from Type 1 wells, with no documentation, to Type 9 wells, which do not penetrate the primary confining unit or storage reservoir (unit). Well accessibility within the AoR varies based on well status, including Dry & Abandoned (DA), Plugged & Abandoned (PA), Injection (INJ), Oil/Gas Producing (PROD), and Observation (Obs) wells. Accessibility levels were determined by well construction, with DA wells being the least accessible and Observation wells the most accessible, impacting gas leakage detection possibilities. Remedial action priority of wells decreases from Type 1 to Type 9 wells. Type 1 to Type 6 wells with status DA and PA require immediate attention, while Type 7 and Type 8 wells are low priority. A risk matrix used to prioritize corrective actions for legacy wells is proposed to categorize wells within an AoR based on penetrations, protections, and accessibility. The methodology involves data acquisition, well categorization into nine types, and determining CO 2 leakage pathways using well schematics and geospatial mapping. This approach is particularly useful for managing the integrity of legacy wells throughout the lifecycle of a Carbon Capture and Storage (CCS) project. A qualitative risk assessment of 94 wells within the AoR of the PSGC site identified 54 wells with high priority for corrective action due to penetration of the primary containment seal. The assessment utilizes color-coded maps to categorize well types and prioritize corrective actions, providing a comprehensive analysis. Schematics of wells penetrating the primary confining unit were drawn, and leakage pathways were identified. Details of all wells penetrating the confining zone are provided in the appendix, including information on well types, plugging, and casing status.

01 COAL, LIGNITE, AND PEAT↗

OES CO 2 Pipeline FEED Project Design Basis Memorandum

The OES CO₂ Pipeline project will move captured carbon dioxide from two ethanol facilities near Gibson City, Illinois, roughly 7.8 miles southeast to three injection wells outside Anchor, where it will be permanently stored underground. The system is designed to handle up to 4.5 million metric tonnes per year of dense-phase CO₂ at pressures up to 2,500 psig, using 16-inch mainline pipe and 10.750-inch laterals made from API 5L X-60 and X-65 steel. Wall thicknesses vary depending on location, with thinner pipe in open country, heavier wall at road crossings, and the heaviest where the pipe passes under highways or railroads via horizontal directional drill. The pipe gets a fusion-bonded epoxy coating, with an added abrasion-resistant layer wherever it's bored or drilled. Major water crossings will use HDD rather than open trenching. The pipeline will be cathodically protected, equipped with SCADA-compatible pressure and temperature instrumentation, and monitored for leaks using a computational pipeline monitoring system per API RP 1130. Hydrostatic testing will be performed at 1.25 times design pressure, and an ILI caliper run will follow to catch any construction defects. Several items, including fracture toughness requirements, specific NDE methods, and ILI tool selection, are left for the detailed design phase. The whole system falls under 49 CFR Part 195 and ASME B31.4, and Gulf Interstate Engineering prepared this document as the FEED-level design basis under the CarbonSAFE Phase III program.

09 BIOMASS FUELS↗

Storage Field Development Plan: One Earth Energy

This Storage Field Development plan presents the Storage Complex characterization results, construction, monitoring, and operational plans, and costs associated with the proposed One Earth Sequestration Carbon Capture and Storage (OES-CCS) site in McLean County, Illinois, near Gibson City. The proposed storage complex, known as the Mt. Simon Storage Complex, comprises the Cambrian Mt. Simon Sandstone reservoir and the primary seal, the Cambrian Eau Claire Formation. The lowermost Underground Source of Drinking Water (USDW) identified for the site is the Ordovician St. Peter Sandstone. Geologic characterization of the Mt. Simon Storage Complex at the OES-CCS site was performed by the Illinois Storage Corridor CarbonSAFE Phase III project, which also prepared and submitted three UIC Class VI applications to construct three injection wells; the permit applications were submitted and are in the federal EPA review process. A characterization well, OEE #1, was drilled to collect site-specific data. These data were analyzed and used to develop the UIC Class VI applications. The OEE #1 well will be converted to an in-zone monitoring (IZM) well for the injection phase. The proposed buildout for the OES-CCS site includes (1) three injection wells (OES #1, OES #2, and OES #3), (2) two IZM wells, (3) two above confining zone (ACZ) monitoring wells, one of which will be used to monitor the lowermost USDW, (4) capture and compression facilities, and (5) transportation facilities, i.e., pipelines. A pre-operational testing program was proposed in the Class VI permit application and will be employed at the site pending approval. Additional pre-injection (baseline), syn-injection, and post-injection monitoring and site care procedures will be followed by OES to ensure that injection activities are protective of human health and the environment. Injection is scheduled to begin in 2025, distributed across the three injection wells in accordance with the permit operating conditions. One Earth Sequestration intends to inject up to 90 million tonnes of CO 2 over a period of approximately 20 years. Injection will begin at approximately 0.5 million tonnes of CO 2 annually and ramp up to a maximum of 4.5 million tonnes annually. Daily injection rates are expected to range from 1,400 to 1,500 tonnes per day initially and reach a maximum of approximately 4,225 tonnes per day, depending on site geology and injectivity at each injection well location, and CO 2 availability. The costs associated with the OES-CCS project include pre-operational costs (e. g. additional seismic data acquisition and well drilling), capture and transportation facility and equipment costs, predicted field operating expenditures (OpEx), and decommissioning and post-injection site care (PISC) costs. The risks associated with project activities, such as site construction, injection operations, and verification of secure storage were evaluated, and mitigation strategies proposed to alleviate those risks.

09 BIOMASS FUELS↗

Geologic Carbon Storage of Anthropogenic CO2 under the Colorado Plateau in Emery County, Utah

Geologic Carbon Storage (GCS) is a promising technology for storing large volumes of anthropogenic CO2 effectively and permanently. Numerical simulations are an integral part of site selection and characterization for any potential GCS site. As part of the DOE-funded CarbonSAFE Rocky Mountains Phase I project, a regional GCS analysis was undertaken to understand the efficacy of storing CO2 emissions from the power generation and heavy industry in central Utah’s favorable geology. In this study, the injection of CO2 for geologic storage was simulated in the Navajo Sandstone Formation in Emery County, Utah. Carbon dioxide was sourced from regional power generation stations and heavy industries throughout Utah, with an emphasis on emissions reduction at the Hunter Power Plant near Castle Dale, Utah. A simulation grid was extracted from the project’s geological model encompassing an area around Price, Huntington, and Castle Dale in central Utah. The Navajo Sandstone Member of the Glen Canyon Group was the target of CO2 injection with the overlying Carmel formation providing the primary seal. A suite of simulations was performed assessing the viability of this area for permanent CO2 storage. Results indicate that the area can not only store 46 million metric tons of anthropogenic CO2, meeting the project goals, but this area has the capacity to securely store at least 1.3 billion tons of CO2, suggesting the injection site and surrounding geology are suitable locations for commercial-scale GCS.

58 GEOSCIENCES↗

Impact of sub-core scale heterogeneity on CO2/brine multiphase flow for geological carbon storage in the Minnelusa sandstone

CO2 geological storage in deep saline aquifers is a mitigation option for CO2 emissions due to its large storage capacity and immediate accessibility. Accurately determining the CO2-brine relative permeability curves is key to the evaluation of CO2 injectivity and sweep efficiency in reservoir simulation as well as the CO2 injection in the field. This study highlights the remarkable effects of sub-core scale heterogeneity on the CO2-brine multiphase flow properties of the Minnelusa Sandstone in Wyoming. Two unsteady state CO2-brine drainage experiments were performed on the two samples. The first sample exhibits slanted laminated structure, while the second one represents a more homogeneous sandstone system. The CO2 saturation distributions during drainage reveals that the main variation in multiphase flow properties of two core samples were attributed to the porosity distribution that leads to the capillary pressure heterogeneity. Assisted history matching was used to obtain the respective relative permeability curves, which suggests heterogeneity-dependent behavior. In addition, sensitive and uncertainty analyses indicate that physical and petro-physical properties of low-porosity and low-permeability bedding layers exert marked effects on CO2 front breakthrough time and brine production. The results presented in this study help to gain insight into the CO2-brine multiphase flow properties in heterogeneous sandstones and can pave the way for the upscaling of CO2 migration and field-scale simulation accurately. This work is funded under the Department of Energy CarbonSAFE program (awards DE-FE0031624 DE0031891).

Kou, Zuhao↗

Exploring the Feasibility of a Carbon Dioxide Storage Hub in Western North Dakota

The University of North Dakota Energy & Environmental Research Center (EERC) and project partner ONEOK, Inc. (ONEOK) are investigating the feasibility of establishing a CO2 (carbon dioxide) storage hub in western North Dakota—in the heart of the Williston Basin. The conceived Roughrider Carbon Storage Hub would store CO2 captured from six gas-processing plants owned and operated by project partner ONEOK and a planned gas-to-liquids plant. This 2-year U.S. Department of Energy-sponsored Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Phase II feasibility study is evaluating the aggregation of the CO2 captured from these seven sources for injection into stacked geologic storage complexes. The proposed hub includes several aspects that make it a highly qualified candidate for a feasibility study with a notably reduced project risk profile. These include 1) a project partner (ONEOK) with a committed goal to reduce greenhouse gas emissions; 2) prior subsurface data analysis supporting a potential stacked storage configuration with adequate CO2 storage resource; 3) commitment from local, regional, and state-level stakeholders; and 4) a state with U.S. Environmental Protection Agency underground injection control Class VI primacy. ONEOK’s assets in the Williston Basin provide significant environmental benefits by capturing and processing natural gas that may otherwise be flared or vented. Storing CO2 from these gas-processing facilities will reduce overall CO2 emissions in the basin while providing essential services to producers there and contributing to continued energy independence in the domestic markets.

03 NATURAL GAS↗

Facies Analysis of the Prairie Du Chien Group in the Illinois Basin and Analogous Rocks in Missouri and Kentucky

Funded in 2023 by the U.S. Department of Energy’s Phase II Carbon Storage Assurance Facility Enterprise (CarbonSAFE) initiative, a Heidelberg Materials cement plant in Mitchell, Indiana, is currently being evaluated as a potential Carbon Capture and Storage (CCS) subsurface injection site. The Heidelberg CCS project targets the middle to upper Prairie du Chien Group (Early Ordovician) in southwestern Indiana. Assessment of reservoir feasibility requires collection of field data, seismic surveys, well-log correlation, geologic modeling, characterization well drilling, well testing, and reservoir simulation. However, the proposed Heidelberg CCS site is in a data-limited region, lacking both outcrop analogs and deep wells penetrating the target interval, which makes geologic modelling difficult prior to drilling a characterization well. To directly address this problem, the present study was undertaken to understand the sedimentologic composition and stratigraphic architecture of the Prairie du Chien Group from analogous outcrops and cores in the Illinois Basin and adjacent regions.

Ali, Shah Bilawal [Univ. of Illinois at Urbana-Cha↗

A simulation study of carbon storage with active reservoir management

As part of the Integrated Midcontinent Stacked Carbon Storage Hub (IMSCS-Hub) project led by Battelle Memorial Institute, a study was conducted to determine the feasibility of storing carbon dioxide (CO 2 ) in the stacked saline rock formations of the Sleepy Hollow Field (SHF), located in Red Willow County, southern Nebraska. A series of CO 2 injection simulation scenarios, with and without active reservoir management (ARM; brine extraction), were evaluated to investigate the feasibility of storing 50+ million tonnes (Mt) of CO 2 . The results indicated CO 2 injection combined with ARM may enable permanent storage of 50+ Mt of CO 2 . The area of review (AOR), the area in which underground sources of drinking water (USDWs) might be endangered during CO 2 injection, was assessed for the simulation scenarios. In comparison to a case without ARM, brine extraction resulted in a much smaller AOR, covering an area of 42 square miles (108.8 km 2 ), roughly one-fourth the size of an AOR resulting from CO 2 injection without ARM. Our findings, presented in this paper, indicate that CO 2 injection with ARM can improve the CO 2 storage capacity of a geologic storage complex up to 100% while also reduce the rate of pressure buildup in the subsurface, resulting in a 75% reduction in AOR. This may help in lowering carbon capture and storage project costs, risks, and effort needed to meet monitoring requirements for a storage project.

54 ENVIRONMENTAL SCIENCES↗

Unsteady- and Steady-State Relative Permeability Study with X-ray and Acoustic Monitoring for CO 2 Storage in Deep Saline Aquifers

In this study, we link the multiphase flow measurements with controls of sedimentary structures (e.g., heterogeneity and anisotropy) on relative permeability to variations in ultrasonic velocities for two deep saline aquifer formations (Entrada and Bluff Sandstones) in the San Juan Basin of the Southwestern USA. The rock specimens were extracted from outcrop sites near Durango, CO, USA. They have distinct differences in grain size, cementation composition, and individual chemical amounts, despite both formations being eolian sandstones. We performed a series of unsteady- and steady-state CO 2 -brine relative permeability experiments under capillary-controlled displacement rates. Unsteady-state experiments were conducted at 71 °C and 9.65 MPa; steady-state experiments were conducted at 85 °C and 22.8 MPa and 89 °C and 24.1 MPa for the Bluff and Entrada Sandstones, respectively. During the unsteady experiments, X-ray computed tomography was used to visualize multiphase flow in porous media and quantify saturations during brine drainage under various flow rates. Scan images and saturation profiles indicate that the CO 2 distribution in the pore volume was strongly impacted by the presence of high-angle cross-laminations, heterogeneous rock structure, and direction of bedding orientation. Those factors contribute to dramatic and quick initial breakthroughs and affect the overall saturation dynamics. Steady-state relative permeability tests were conducted at net flow rates of 1 mL/min for both brine drainage and imbibition. During the experimental steps, the CO 2 fractional flow was increased and decreased for both drainage and imbibition scenarios to mimic the front when CO 2 contacts brine and behind the front when brine enters space previously occupied by CO 2 . It was found that compressional velocity decreased, while shear waves slightly increased as brine saturation decreased. The hysteresis effects for the relative permeability and acoustic velocities were distinct. Furthermore, the CO 2 /brine front stability is quantified by applying a mobility ratio approach to spot saturations at which the boundary line between fluids becomes uneven. The results presented in this work can potentially boost the quality and precision of forecasts for the CO 2 storage projects in which the vertical and horizontal core-scale heterogeneity and anisotropy impact the plume migration within host reservoirs.

carbon dioxide (CO2)↗