At least 109 records · Page 6

Modeling void growth and movement with phase change in thermal energy storage canisters

A scheme was developed to model the thermal hydrodynamic behavior of thermal energy storage salts. The model included buoyancy, surface tension, viscosity, phases change with density difference, and void growth and movement. The energy, momentum, and continuity equations were solved using a finite volume formulation. The momentum equation was divided into two pieces. The void growth and void movement are modeled between the two pieces of the momentum equations. Results showed this scheme was able to predict the behavior of thermal energy storage salts.

Darling, Douglas↗

Mars Orbiter Sample Return Power Design

The NASA/JPL 2003/2005 Mars Sample Return (MSR) Missions will each have a sample return canister that will be filled with samples cored from the surface of MARS. These spherical canisters will be 14.8 cm in diameter and must be powered only by solar cells on the surface and must communicate using RF transmission with the recovery vehicle that will be coming in 2006 or 2009 to retrieve the canister. This paper considers the aspect and conclusion that went into the design of the power system that achieves the maximum power with the minimum risk. The power output for the spherical orbiting canister was modeled and plotted in various views of the orbit by the SOAP program developed by JPL. The requirements and geometry for a solar array on a sphere are unique and place special constraints on the design. These requirements include 1) accommodating a lid for sample loading into the canister, surface area was restricted from use on the Northern pole of the spherical canister. 2) minimal cell surface coverage (maximum cell efficiency), less than 40%, for recovery vehicle to locate the canister by optical techniques. 3) a RF transmission during 50% of MARS orbit time on any spin axis, which requires optimum circuit placement of the solar cell onto the spherical canister. The best configuration would have been a 4.5 volt round cell, but in the real world we compromised with six triangular silicon cells connected in series to form a hexagon. These hexagon circuits would be mounted onto a flat facet cut into the spherical canister. The surface flats are required in order to maximize power, the surface of the cells connected in series must be at the same angle relative to the sun. The flat facets intersect each other to allow twelve circuits evenly spaced just North and twelve circuits South of the equator of the spherical canister. Connecting these circuits in parallel allows sufficient power to operate the transmitter at minimum solar exposure, Northern pole of the canister facing the sun. Additional power, as much as 20%, is also generated by the circuits facing MARS due to albedo of MARS.

Mardesich, N.↗

Modeling and Simulation of a Tethered Harpoon for Comet Sampling

This paper describes the development of a dynamic model and simulation results of a tethered harpoon for comet sampling. This model and simulation was done in order to carry out an initial sensitivity analysis for key design parameters of the tethered system. The harpoon would contain a canister which would collect a sample of soil from a cometary surface. Both a spring ejected canister and a tethered canister are considered. To arrive in close proximity of the spacecraft at the end of its trajectory so it could be captured, the free-flying canister would need to be ejected at the right time and with the proper impulse, while the tethered canister must be recovered by properly retrieving the tether at a rate that would avoid an excessive amplitude of oscillatory behavior during the retrieval. The paper describes the model of the tether dynamics and harpoon penetration physics. The simulations indicate that, without the tether, the canister would still reach the spacecraft for collection, that the tether retrieval of the canister would be achievable with reasonable fuel consumption, and that the canister amplitude upon retrieval would be insensitive to variations in vertical velocity dispersion.

small body↗

Critical technology experiment results for lightweight space heat receiver

Critical technology experiments have been performed on thermal energy storage modules in support of the NASA Advanced Solar Dynamic Brayton Heat Receiver Program. The modules, wedge-shaped canisters containing lithium fluoride (LiF), were designed to minimize the mechanical stresses that occur during the phase change of the LiF. Nickel foam inserts were placed in two of the test canisters to provide thermal conductivity enhancement and to distribute the void volume throughout the canister. A procedure was developed for reducing the nickel oxides on the nickel foam to enhance the wicking ability of the foam. The canisters were filled with LiF and closure-welded at the NASA Lewis Research Center. Two canisters, one with a nickel foam insert, the other without an insert, were thermally cycled in various orientations in a fluidized bed furnace. Computer-aided tomography was successfully used to nondestructively determine void locations in the canisters. Finally, canister dimensional stability was measured after thermal cycling with an inspection fixture.

Schneider, Michael G.↗

Mars Orbit Rendezvous Strategy for the Mars 2003/2005 Sample Return Mission

The primary objective of the Mars 2003/2005 Sample Return Project is to return Martian surface materials to Earth from two different sites by the year 2008. The baseline mission plan relies heavily on the use of a Mars orbit rendezvous strategy similar to the lunar orbit rendezvous scheme used for the Apollo missions. The 2003 mission consists of a single spacecraft comprised of a Lander, Rover, and Mars ascent vehicle (MAV). The 2003 mission will be launched on a Delta-III-class launch vehicle in May/June 2003 and arrive at Mars in December 2003/January 2004. The Lander deploys the Rover to collect surface samples from several sites and return them to the Lander where they are transferred to a sample canister onboard the MAV. The MAV is launched into a low Mars orbit (targeted for 600 km circular, 45 deg inclination) and releases the sample canister to await retrieval by an Orbiter launched in 2005. (The sample canister is a passive vehicle with no maneuvering capability.) The duration of Mars surface operations is at most about 90 days. The 2005 mission consists of two separate spacecraft: a Lander/Rover/MAV spacecraft identical to that used for the 2003 mission and an Orbiter carrying an Earth Entry Vehicle (EEV). Both spacecraft will be launched on a single Ariane-5 in August 2005 and arrive at Mars in July/August 2006. A second sample canister is delivered to Mars orbit using the same scenario as was used for the 2003 mission. The Orbiter uses aerocapture for insertion into Mars orbit (targeted for 250 x 1400 km, 45 deg inclination). During its approximately one-year stay at Mars, the Orbiter will search for and attempt to rendezvous first with the 2003 sample canister and then with the 2005 sample canister. After retrieval, each sample canister is transferred to the EEV. The Orbiter departs Mars in July 2007 and returns to Earth in October 2008 on a trajectory targeted for landing at the Utah Test and Training Range (UTTR). After deploying the EEV, the Orbiter performs a deflection maneuver to avoid reentry into Earth's atmosphere.

DAmario, Louis A.↗

Mars Orbiter Sample Return Power Design

Mars has greatly intrigued scientists and the general public for many years because, of all the planets, its environment is most like Earth's. Many scientists believe that Mars once had running water, although surface water is gone today. The planet is very cold with a very thin atmosphere consisting mainly of CO2. Mariner 4, 6, and 7 explored the planet in flybys in the 1960s and by the orbiting Mariner 9 in 1971. NASA then mounted the ambitious Viking mission, which launched two orbiters and two landers to the planet in 1975. The landers found ambiguous evidence of life. Mars Pathfinder landed on the planet on July 4, 1997, delivering a mobile robot rover that demonstrated exploration of the local surface environment. Mars Global Surveyor is creating a highest-resolution map of the planet's surface. These prior and current missions to Mars have paved the way for a complex Mars Sample Return mission planned for 2003 and 2005. Returning surface samples from Mars will necessitate retrieval of material from Mars orbit. Sample mass and orbit are restricted to the launch capability of the Mars Ascent Vehicle. A small sample canister having a mass less than 4 kg and diameter of less than 16 cm will spend from three to seven years in a 600 km orbit waiting for retrieval by a second spacecraft consisting of an orbiter equipped with a sample canister retrieval system, and a Earth Entry Vehicle. To allow rapid detection of the on-orbit canister, rendezvous, and collection of the samples, the canister will have a tracking beacon powered by a surface mounted solar array. The canister must communicate using RF transmission with the recovery vehicle that will be coming in 2006 or 2009 to retrieve the canister. This paper considers the aspect and conclusion that went into the design of the power system that achieves the maximum power with the minimum risk. The power output for the spherical orbiting canister was modeled and plotted in various views of the orbit by the Satellite Orbit Analysis Program (SOAP).

Mardesich, N.↗

ISS External Microorganisms: A Planetary Protection Experiment to Inform Requirements for Crewed Missions to Mars

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

Sample Curation in Support of the OSIRIS-REx Asteroid Sample Return Mission

The OSIRIS-REx asteroid sample return mission launched to asteroid Bennu Sept. 8, 2016. The spacecraft will arrive at Bennu in late 2019, orbit and map the asteroid, and perform a touch and go (TAG) sampling maneuver in July 2020. After sample is stowed and confirmed the spacecraft will return to Earth, and the sample return capsule (SRC) will land in Utah in September 2023. Samples will be recovered from Utah [2] and then transported and stored in a new sample cleanroom at NASA Johnson Space Center in Houston [3]. The materials curated for the mission are described here. a) Materials Archive and Witness Plate Collection: The SRC and TAGSAM were built between March 2014 and Summer of 2015, and instruments (OTES,OVIRS, OLA, OCAMS, REXIS) were integrated from Summer 2015 until May 2016. A total of 395 items were received for the materials archive at NASA-JSC, with archiving finishing ~30 days after launch (with the final archived items being related to launch operations)[4]. The materials fall into several general categories including metals (stainless steel, aluminum, titanium alloys, brass and BeCu alloy), epoxies, paints, polymers, lubricants, non-volatile-residue samples (NVR), sapphire, and various miscellaneous materials. All through the ATLO process (from March 2015 until late August 2016) contamination knowledge witness plates (Si wafer and Al foil) were deployed in the various cleanrooms in Denver and KSC to provide an additional record of particle counts and volatiles that is archived for current and future scientific studies. These plates were deployed in roughly monthly increments with each unit containing 4 Si wafers and 4 Al foils. We archived 128 individual witness plates (64 Si wafers and 64 Al foils); one of each witness plate (Si and Al) was analyzed immediately by the science team after archiving, while the remaining 3 of each are archived indefinitely. Information about each material archived is stored in an extensive database at NASA-JSC, and key summary information for each will be presented in an online catalog. b) Bulk Asteroid sample: The Touch and Go Sampling Mechanism (TAGSAM) head will contain up to 1.5 kg of asteroid material. Upon return to Earth, the TAGSAM head with the sample canister will be subjected to a nitrogen purge and then opened in a nitrogen cabinet in Houston. Once the TAGSAM head is removed from the canister, it will be dis-assembled slowly and carefully under nitrogen until the sample can be removed for processing in a dedicated nitrogen glovebox. Bennu surface samples are expected to be sub-cm sized, based on thermal infrared and radar polarization ratio measurements [1]. The upper limit on material collected by the TAGSAM head is ~2 cm. Therefore, we will be prepared to handle, subdivide, and characterize materials of a wide grain size (from ~10 m to 2 cm), and for both organic (UV fluorescence) and inorganic (SEM, FTIR, optical) properties. Representative portions of the bulk sample will be prepared for JAXA (0.5 %; see also [5]) and Canadian Space Agency (4%), with the remaining divided between the science team (<25%) and archived for future studies (NASA) (>75%). c) Contact Pad samples: The base of the TAGSAM head contains 24 contact pads that are designed to trap the upper surface layer of material and thus offer an opportunity to study asteroid samples that have resided at the very top surface of the regolith. Asteroid material is trapped on the pads in spring steel Velcro hooks, and material will have to be removed from these pads by curation specialists in the lab. d) Hardware: Some canister and SRC hardware items will contain information that will be important to understanding the collected samples, including the canister gas filter, temperature strips, flight witness plates, and the TAGSAM and canister parts that might have adhering dust grains. Some challenges remaining for both bulk sample and contact pad samples include: i) working with intermediate size range (200 to 500 micron) samples - a size range NASA has not previously worked in such detail; ii) techniques for removal of contact pad material from the spring steel hooks, iii) static electrical effects of dust sized particles during sample handling and curation is likely to be significant, and iv) the TAGSAM head and associated canister hardware will undoubtedly be coated with fine adhering dust grains from Bennu. In the case of collection of a large bulk sample mass, the adhering dust grains may be of lower priority. If a small sample mass is returned, the adhering dust may attain a higher priority, so recovery of adhering dust grains is an additional challenge to consider. In the year leading up to sample return we plan a variety of sample handling rehearsals that will enables the curation team to be prepared for many new aspects posed by this sample suite.

Righter, Kevin↗

Modeling Approach for the Aluminum-clad Dry Storage Pilot using HFIR Fuel

To confirm that the dry storage of aluminum-clad research reactor spent nuclear fuel (ASNF) will remain within the safety envelope after applied drying schemes and that the resulting evolution of the gas space composition, temperature, and pressure conditions are understood, a dry storage pilot project is being established. The pilot will incorporate an instrumented lid for discrete interval or for on-demand gas composition and temperature monitoring of two DOE Standard Canisters (DSCs) loaded with three High Flux Isotope Reactor (HFIR) inner cores per DSC. Each DSC would be subjected to a separate alternative candidate drying scheme. Canisters will undergo 1 to 5 years of monitoring, including internal temperature and gas sampling to track pressure and composition changes. This report outlines the approach for modeling the ASNF-in-canister behavior in terms of evolving gas space conditions for the ASNF dry storage pilot using HFIR fuel. The ASNF has an adherent surface oxyhydroxide layer comprised of boehmite/bayerite that generates hydrogen when subjected to irradiation. Three-dimensional multi-physics computational fluid dynamics simulations will be executed to compute the thermal field within the DSC and provide inputs to a chemical model employed to compute pressure buildup as hydrogen is generated in the system. Implemented in Cantera, the chemical model solves gas phase and aluminum oxyhydroxide surface-mediated radiolysis reactions. Gas phase reactions are sourced from Wittman and Hanson (2015), whereas surface-mediated reactions are incorporated by fitting experimental data using an optimization algorithm (Abboud, 2023). Water radiolysis reactions from Wren and Ball (2001) are adopted with modifications as described in Abboud (2023c). Understanding the effect of the hydrogen buildup over time is important for long-term storage safety considerations. Modeling results will include the canister pressure, temperature, and composition evolution from the initial helium backfill with the addition of radiolytically-evolved chemical species (e.g., hydrogen and oxygen). The specific HFIR cores for the pilot program have not yet been selected, and the overall design is still in development. The CFD-chemical model used for this work will be based on prior models with necessary updates to allow for improved accuracy and efficiency. The experimental data obtained from the HFIR demonstration will be used to improve and validate the computational models to predict the ASNF-in-canister behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Convergent Manufacturing of Large-Scale Components for Nuclear Applications, via Additive Manufacturing and Powder Metallurgy Hot Isostatic Pressing

Powder metallurgy (PM)–hot isostatic pressing (PM-HIP) has long been recognized as a powerful route for producing fully dense, near net shape metallic components. By consolidating powders under high temperature and pressure, HIP provides isotropic properties, uniform microstructures, and scalability to complex geometries that are vital for sectors such as aerospace, energy, and nuclear power. Yet despite these advantages, the technology has remained constrained by costly trial and error canister fabrication, limitations of conventional forging, and incomplete knowledge about how the canister design influences final part properties. Additive manufacturing (AM), by contrast, thrives on design freedom and geometric flexibility but struggles with speed, scalability, and cost when applied to very large structures. The research presented in this report investigated how a convergent manufacturing approach, combining AM with PM-HIP, can merge the strengths of both technologies, leveraging AM’s flexibility for canister design and HIP’s consolidation capability to deliver reliable, large, and complex parts. The work progressed through three case studies that built on one another in scale and complexity. Small cylindrical canisters fabricated by conventional methods, laser powder bed fusion, and directed energy deposition were filled with stainless steel powders and subjected to HIP. The resulting parts demonstrated near-full density and mechanical properties on par with wrought stainless steel, showing for the first time that AM canisters can be a direct substitute for conventional ones without sacrificing quality. The next step involved a medium-scale, noncentrosymmetric T-valve, which is an enclosed, multibranch geometry that tested the limits of AM + PM-HIP integration. The T-valve achieved predictable shrinkage and uniform densification, confirming feasibility for enclosed designs. However, this study also revealed oxide inclusions and interfacial challenges at the AM + HIP boundary, underscoring the critical importance of controlling interface chemistry and employing robust, in situ strategies, such as melt pool monitoring and thermal monitoring, coupled with nondestructive evaluation techniques such as x-ray computed tomography. Finally, the effort culminated in fabricating a large-scale impeller weighing nearly 2000 lb and spanning 5 ft in diameter. Produced via multirobot wire arc AM and hot isostatic pressed to near-full density, the impeller validated industrial-scale feasibility. Predictive models closely matched experimental shrinkage, tensile properties were spatially uniform across the component, and the AM + PM-HIP interface proved mechanically sound despite the presence of oxide-decorated prior particle boundaries. This large-scale demonstration is a major milestone, showing that hybrid AM + PM‑HIP can reliably deliver components at reactor-relevant scales. Collectively, these studies charted a logical pathway: small-scale work built scientific confidence, medium-scale work highlighted opportunities and challenges, and large-scale work proved industrial impact. The overarching conclusion of this report is that AM + PM-HIP should not be seen as a replacement for forging but as a complementary pathway that provides the US with flexibility, resilience, and new options for manufacturing nuclear-grade components. Looking ahead, several directions emerge as critical to sustaining progress. Predictive modeling must become faster, more accessible, and more accurate, with digital twins and machine learning reducing reliance on trial and error. Powders and alloys must be optimized for HIP, with improved cleanliness, reduced oxides, and tailored chemistries that enhance creep, fatigue, and irradiation resistance. Interfaces between AM and HIP regions must be better engineered through coatings, machining strategies, and surface treatments to mitigate oxide formation and ensure reliable bonding to explore opportunities for HIP of targeted compositional parts, as well as multimaterial HIP cladding applications. Monitoring and nondestructive evaluation need to expand, incorporating multimodal sensors, x-ray computed tomography, and real-time data integration through platforms such as Pelican. At the same time, the pathway to industrial adoption requires techno-economic analysis, machinability studies, and qualification frameworks aligned with industry and regulatory standards. Finally, workforce and academic engagement must be strengthened. Programs that train technicians and engineers for US Navy and US Department of Energy manufacturing challenges should be paired with academic partnerships to support fundamental research, with open sharing of non-export-controlled data to accelerate innovation and build the next generation of experts. In conclusion, this report demonstrates that hybrid AM + PM-HIP is scientifically viable and strategically important. By combining the design agility of AM with the consolidation strength of HIP and embedding modeling, monitoring, and workforce development, this approach provided a transformative new capability for US manufacturing. The path forward is clear: hybrid AM + PM-HIP is not just a promising research direction but is also potentially an industrially relevant pathway that can reshape how nuclear-grade components are designed, qualified, and deployed.

36 MATERIALS SCIENCE↗