TECHNOLOGY GOALS FOR A NEXT GENERATION RADIOXENON MONITORING SYSTEM

The Swedish Automated/Unattended Noble Gas Analyzer (SAUNA) is a nuclear explosion monitoring technology that was developed to provide continuous field measurement of radioxenon gas escaping from an underground nuclear detonation. This capability is a key to the verification of the Comprehensive nuclear Test Ban Treaty (CTBT). While the SAUNA technology has demonstrated success in the field, a decade of operation primarily in the International Noble Gas Experiment (INGE) has yielded areas for improvement in operations and verification. These opportunities include measurement sensitivity, sample throughput time, system uptime, and data availability. Increasing measurement sensitivity allows for finer discrimination between manmade radioxenon signals (from sources such as medical isotope production facilities) and radioxenon signals that result from fission in a nuclear weapon. Measurement sensitivity can be increased with techniques such as halving the sample processing time or increasing the quantity of xenon extracted from the atmosphere. Additionally, improvements in gas processing technology and control system software can improve the uptime and data availability. This paper will discuss the technical requirements as well as the system and operational specifications which we expect to be the groundwork for the next-generation of radioxenon monitoring systems.

Ely, James H.↗

Extraction of Xenon using Enriching Reflux Pressure Swing Adsorption

Measuring radioactive xenon isotopes in the atmosphere is an important technique used for monitoring within the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Several process steps are needed to capture and prepare a xenon sample suitable for transfer to a nuclear detector. These processes include air drying, xenon collection, concentration and purification. The ideal xenon sampling system would be small, have low power consumption, not use consumables (such as helium gas or liquid nitrogen) and be fully automated, robust and dependable. Due to the low concentration of xenon in the air, the most energy intensive part of the gas processing is the first stage collection and concentration. Pacific Northwest National Laboratory has developed a batch mode enriching-reflux pressure-swing-adsorption (ER-PSA) process that shows promise as a xenon collection and concentration technique. The development of this process was guided by finite element models of the process chemistry. The modeling showed minimizing the xenon dispersion in the adsorption columns is critical to achieving a good separation. Prior to hardware construction, models were used to determine appropriate trap dimensions, adsorbent particle size and optimum process variables such as cycle steps, step times, and flow rates. A bench top ER-PSA unit was constructed and testing under various operating conditions has begun. The results obtained in these initial parametric experiments have provided insight into the physics of the process and have refined the mathematical models. The combination of modeling and experiment provides a better understanding of process physics than either experiment or models alone. The bench top system has demonstrated room temperature collection of xenon with a xenon enrichment of 1000 (starting from air) with a modest pressure ratio of 7-10 resulting in an energy efficient separation technique. The technique does not use exotic adsorbents, cryogenic temperatures or high pressure compressors, enabling a small, low power and robust system. This ER-PSA process is an enabling technology for small energy efficient xenon collectors, desirable qualities for next generation international xenon systems.

Williams, Richard M.↗

Novel Photonuclear Methods to Produce an Argon-37 Standard

The mission of this research is to explore novel photonuclear-based pathways into the production of 37Ar. Above-background detection levels of 37Ar uniquely indicates the occurrence of an underground nuclear explosion, produced from fission neutrons interacting in the surrounding environment through the 40Ca(n,a)37Ar reaction. The half-life of 35 days allows on-site inspectors (OSI) adequate time following the nuclear event to detect 37Ar and verify compliance or defiance of non-proliferation treaties such as the Comprehensive Nuclear-Test-Ban Treaty (CTBT). An 37Ar standard would give OSI the ability to calibrate their detectors and measure detector efficiency allowing for the quantification of detected activity, give OSI authentic samples to test detectors in field exercises, and improve models predicting diffusion pathways of 37Ar through the underground environment.

43 PARTICLE ACCELERATORS↗

Production of 37Ar in The University of Texas TRIGA reactor facility

The detection of {sup 37}Ar is important for on-site inspections for the Comprehensive Nuclear-Test-Ban Treaty monitoring. In an underground nuclear explosion this radionuclide is produced by {sup 40}Ca(n,{alpha}){sup 37}Ar reaction in surrounding soil and rock. With a half-life of 35 days, {sup 37}Ar provides a signal useful for confirming the location of an underground nuclear event. An ultra-low-background proportional counter developed by Pacific Northwest National Laboratory is used to detect {sup 37}Ar, which decays via electron capture. The irradiation of Ar gas at natural enrichment in the 3L facility within the Mark II TRIGA reactor facility at The University of Texas at Austin provides a source of {sup 37}Ar for the calibration of the detector. The {sup 41}Ar activity is measured by the gamma activity using an HPGe detector after the sample is removed from the core. Using the {sup 41}Ar/{sup 37}Ar production ratio and the {sup 41}Ar activity, the amount of {sup 37}Ar created is calculated. The {sup 41}Ar decays quickly (half-life of 109.34 minutes) leaving a radioactive sample of high purity {sup 37}Ar and only trace levels of {sup 39}Ar.

37Ar, CTBT, On-Site Inspections, Radioargon↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SDAT – Analysis of 131mXe with 133Xe Interference

The Spectral Deconvolution Analysis Tool (SDAT) software was developed at The University of Texas at Austin. SDAT utilizes a standard spectrum technique for the analysis of beta-gamma coincidence spectra. Testing was performed on the software to compare the standard spectrum analysis technique with a region of interest (ROI) analysis technique. Experimentally produced standard spectra and sample data were produced at the Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor. The results of the testing showed that the standard spectrum technique had lower errors than the ROI analysis technique for samples with low counting statistics. In contrast, the ROI analysis technique outperformed the standard spectrum technique in high counting statistics samples. It was also shown that the standard spectrum technique benefitted from a compression of the number of channels within the spectra.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Consideration of impact of atmospheric intrusion in subsurface sampling for investigation of suspected underground nuclear explosions

Radioactive noble gases radioxenon and radioargon constitute the primary smoking gun of an underground nuclear explosion. The aim of subsurface sampling of soil gas as part of an on-site inspection (OSI) is to search for evidence of a suspected underground nuclear event. It has been hypothesized that atmospheric gas can disturb soil gas concentrations and therefore potentially add to problems in civilian source discrimination verifying treaty compliance under the comprehensive nuclear-test-ban treaty. Furthermore, this work describes a study of intrusion of atmospheric air into the subsurface and its potential impact on an OSI using results of simulations from the underground transport of environmental xenon (UTEX) model.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Alternative treaty monitoring approaches using ultra-low background measurement technology

The International Monitoring System (IMS) of the Comprehensive Test Ban Treaty includes a network of stations and laboratories for collection and analysis of radioactive aerosols. Alternative approaches to IMS operations are considered as a method of enhancing treaty verification. Ultra-low background (ULB) detection promises the possibility of improvements to IMS minimum detectable activities (MDAs) well below the current approach, requiring MDAp30 mBq/m3 of air for 140Ba, or about 106 fissions per daily sample.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Maximum Reasonable Radioxenon Releases from Medical Isotope Production Facilities and Their Effect on Monitoring Nuclear Explosions

Fission gases such as 133Xe are used extensively for monitoring the world for signs of nuclear testing in systems such as the International Monitoring System (IMS). These gases are also produced by nuclear reactors and by fission production of 99Mo for medical use. Recently, medical isotope production facilities have been identified as the major contributor to the background of radioactive xenon isotopes (radioxenon) in the atmosphere (Saey, et al., 2009). These releases pose a potential future problem for monitoring nuclear explosions if not addressed. As a starting point, a maximum acceptable daily xenon emission rate was calculated, that is both scientifically defendable as not adversely affecting the IMS, but also consistent with what is possible to achieve in an operational environment. This study concludes that an emission of 5×109 Bq/day from a medical isotope production facility would be both an acceptable upper limit from the perspective of minimal impact to monitoring stations, but also appears to be an achievable limit for large isotope producers.

07 ISOTOPE AND RADIATION SOURCES↗

Potential impact of releases from a new Molybdenum-99 production facility on regional measurements of airborne xenon isotopes

The monitoring of the radioactive xenon isotopes 131mXe, 133Xe, 133mXe, and 135Xe is important for the detection of nuclear explosions. While backgrounds of the xenon isotopes are short-lived, they are constantly replenished from activities dominated by the fission-based production of 99Mo used for medical procedures. One of the most critical locations on earth for the monitoring of nuclear explosions is the Korean peninsula, where the Democratic Republic of North Korea (DPRK) has announced that it had conducted three nuclear tests between 2009 and 2013. This paper explores the backgrounds that would be caused by the medium to large scale production of 99Mo in the region of the Korean peninsula.

Comprehensive Nuclear-Test-Ban Treaty↗

Radioxenon spiked air

Four of the radioactive xenon isotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) with half-lives ranging from 9 h to 12 days are produced from nuclear fission and can be detected from days to weeks following their production and release. Being inert gases, they are readily transported through the atmosphere. Sources for release of radioactive xenon isotopes include operating nuclear reactors via leaks in fuel rods, medical isotope production facilities, and nuclear weapons' detonations. They are not normally released from fuel reprocessing due to the short half-lives. The Comprehensive Nuclear-Test-Ban Treaty has led to creation of the International Monitoring System. The International Monitoring System, when fully implemented, will consist of one component with 40 stations monitoring radioactive xenon around the globe. Monitoring these radioactive xenon isotopes is important to the Comprehensive Nuclear-Test-Ban Treaty in determining whether a seismically detected event is or is not a nuclear detonation. A variety of radioactive xenon quality control check standards, quantitatively spiked into various gas matrices, could be used to demonstrate that these stations are operating on the same basis in order to bolster defensibility of data across the International Monitoring System. This study focuses on Idaho National Laboratory's capability to produce three of the xenon isotopes in pure form and the use of the four xenon isotopes in various combinations to produce radioactive xenon spiked air samples that could be subsequently distributed to participating facilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using STAX data to predict IMS radioxenon concentrations

The noble gas collection and measurement stations in the International Monitoring System (IMS) are heavily influenced by releases from medical isotope production facilities. The ability to reliably model the movement of radioxenon from the points of release to these IMS samplers has improved enough that a routine aspect of the analysis of IMS radioxenon data should be the prediction of the effect of releases from civilian nuclear facilities on the sample concentrations. In this work, predicted concentrations at IMS noble gas systems in Germany and Sweden based on measured releases from Institute for Radioelements (IRE) in Belgium and atmospheric transport modeling for a four-month period are presented and discussed.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).