Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Simulation toolkit for digital material characterization of large image-based microstructures

In this paper, an efficient image-based simulation toolkit for material characterization is presented, which is scalable to work from personal computers to workstations. The effective thermal conductivity, elasticity, and permeability are evaluated employing a computational homogenization framework based on the Finite Element Method (FEM). Two complementary open-source packages are presented: one developed in Python, which can convert digital images into voxel meshes (pyTomoviewer); the other developed in Julia, that can run numerical simulations to compute effective material properties (chpack). Also, a CUDA C version of chpack is provided (chfem_gpu). They were designed to deal with large multi-phase models, so strategies were devised to minimize their memory footprint, while avoiding a high toll on execution time. The voxel-based approach significantly simplifies the FEM meshes and allows efficient matrix-free implementations. In that sense, to handle large linear systems of equations, the element-by-element (EBE) technique is adopted, in conjunction with a low-memory implementation of the Preconditioned Conjugate Gradient (PCG) method. Finally, the code was thoroughly tested on an artificial geometry made of a square array of cylinders, for which analytical solutions exist, as well as on a real micro-tomographic reconstruction of FiberForm TM , a carbon preform commonly used in thermal protection systems.

36 MATERIALS SCIENCE↗

Generalized parton distributions from lattice QCD with asymmetric momentum transfer: Unpolarized quarks at nonzero skewness

We extend the formalism of asymmetric frames of reference for generalized parton distributions (GPDs) to the case of nonzero skewness, i.e., including longitudinal momentum transfer. The framework, based on Lorentz-invariant amplitudes and previously developed and numerically implemented for unpolarized, helicity and transversity GPDs at zero skewness, gives efficient access to a broad range of kinematics, making full mapping of GPDs from the lattice realistic. The general-skewness formalism is tested using lattice data with both transverse and longitudinal or only longitudinal momentum transfer, the latter being a special case with a reduced number of independent amplitudes. We extract the amplitudes in coordinate space and express the GPDs 𝐻 and 𝐸 in terms of these amplitudes. This is followed by reconstruction of quasidistributions and their matching to the light cone. We further identify and discuss the principal challenges for nonzero skewness GPDs.

Lattice QCD↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Ultrasparse View X-ray Computed Tomography for 4D Imaging

X-ray computed tomography (CT) is a noninvasive, nondestructive approach to imaging materials, material systems, and engineered components in two and three dimensions. Acquisition of three-dimensional (3D) images requires the collection of hundreds or thousands of through-thickness X-ray radiographic images from different angles. Such 3D data acquisition strategies commonly involve suboptimal temporal sampling for in situ and operando studies (4D imaging). Herein, we introduce a sparse-view imaging approach, Tomo-NeRF, which is capable of reconstructing high-fidelity 3D images from <10 twodimensional radiographic images. Experimental 2D and 3D X-ray images were used to test the reconstruction capability in two-view, four-view, and six-view scenarios. Tomo-NeRF is capable of reconstructing 3D images with a structural similarity of 0.9971–0.9975 and a voxel-wise accuracy of 81.83–89.59% from 2D experimentally obtained images. Furthermore, the reconstruction accuracy for the experimentally obtained images is less than the synthetic structures. Experimentally obtained images demonstrate a similarity of 0.9973–0.9984 and a voxelwise accuracy of 84.31–95.77%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Regularization by denoising diffusion models for solving inverse PDE problems with application to full waveform inversion

Partial differential equation (PDE)-governed inverse problems are fundamental across various scientific and engineering applications; yet they face significant challenges due to nonlinearity, ill-posedness, and sensitivity to noise. Here, we introduce a computational framework, regularization by denoising using diffusion models for partial differential equations (RED-DiffEq), by integrating physics-driven inversion and data-driven learning. RED-DiffEq leverages pretrained diffusion models as a regularization mechanism for PDE-governed inverse problems. We apply RED-DiffEq to solve the full waveform inversion problem in geophysics, a challenging seismic imaging technique that seeks to reconstruct high-resolution subsurface velocity models from seismic measurement data. Our method shows enhanced accuracy and robustness compared to benchmark methods. Additionally, it exhibits strong generalization and domain decomposition capacity, enabling the inversion of more complex velocity models with larger domains than those used in training the diffusion model. Our framework can also be directly applied to diverse PDE-governed inverse problems.

Shan, Siming [Yale University, New Haven, CT (Unit↗

From clutter to clarity: Emergent neural operators via questionnaire metrics

Real-world datasets in chemical engineering and bioengineering processes—such as those from catalytic reactors, multiphase flows, polymerization reactors, bioreactors, and clinical trials—can often be unlabeled or disorganized, rendering the training of existing supervised learning models ineffective at learning the underlying dynamics. To salvage these datasets for decision-making, we first seek to obtain clarity from the cluttered data. Here, we present a framework for developing “structural” generative models, discovering emergent equations, and constructing efficient emulators from scrambled datasets by integrating unsupervised organizational learning techniques (Questionnaires) with advanced deep learning architectures (Deep Hidden Physics Models and Deep Operator Networks). Our approach is demonstrated on two illustrative model systems: (a) a 1D advection–diffusion partial differential equation representing a winding underground pipe and (b) an ensemble of Stuart–Landau oscillators, an agent-based system of coupled ordinary differential equations. In both cases, we successfully reconstruct meaningful spatial, temporal, and parameter embeddings from scrambled data, enabling good predictions of system dynamics. As a result, we highlight the framework’s potential for broader applications, enabling data-driven system identification in fields with inherently disorganized or hidden parameter spaces.

42 ENGINEERING↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

3D pore structure reconstruction of fluff region in top of EBR-II irradiated fuel by X-ray micro-computed tomography

Metallic fuels comprised of U-Zr binary and U-Pu-Zr ternary alloys are a promising fuel candidate for sodium-cooled fast reactors and possess many advantages over ceramic fuels such as higher uranium density and improved thermal conductivity. Fluff is a highly porous structure forming at the top of metallic fuel slugs during irradiation and was extensively observed in past sodium-cooled fast reactor (SFR) experiments such as Idaho National Laboratory’s Experimental Breeder Reactor II (EBR-II). Previous investigations have shown that fluff is rich in fissile atoms and hence could have neutronics implications, but its formation mechanisms are not understood. In this work, two cube-shaped lift outs were taken from the fluff and bulk fuel regions of a high burnup U-19Pu-10Zr composition EBR-II fuel slug and characterized by micro computed tomography (Micro-CT) and energy dispersive x-ray spectroscopy (EDS). This was used to characterize differences in microscale porosity and composition between fluff and bulk fuel, and to support or oppose postulated fluff formation mechanisms. Surface EDS showed minimal differences between the elemental compositions of the fluff and fuel cubes. However, three-dimensional (3D) pore analysis from the tomography scans showed significant differences between the fluff and fuel cube pore size distributions at the microscale level. The high porosity and irregular pore distribution seen in macroscale fluff was also present within the micro-scale fluff cube, having a much higher porosity than the fuel cube which was concentrated in a few large pore networks. In conclusion, these results indicate support for a creep driven mechanism of fluff formation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploratory calculation of 𝐾 L → 𝜇 + ⁢𝜇 − decay from lattice QCD at physical pion mass

We compute the complex, long-distance two-photon-exchange amplitude which contributes to the rare 𝐾 L → 𝜇 + ⁢𝜇 − decay from lattice QCD. We use a 24 3 × 64 physical-pion-mass gauge field ensemble at an inverse lattice spacing of 1.023 GeV and a QED ∞ -based formalism. Our implementation strategies for all five non-SU(3)-flavor-suppressed diagram topologies are given in detail. We achieve a 25% statistical precision on the dispersive part of this long-distance amplitude. This calculation is carried out with 2+1 quark flavors and therefore requires the addition of counterterms to compensate for the absence of the Glashow-Iliopoulos-Maiani mechanism. These counterterms are not included in the current calculation and will be the subject of a second paper. Although a direct comparison to experiment cannot yet be made because of those omitted counterterms, the present exploratory calculation allows one to identify principal sources of statistical uncertainty in this calculation. The precision of our results is limited by the reconstruction of the physical contribution of the 𝜂 intermediate state, for which various strategies are tested and compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scalable method for micro-CT analysis enables large scale quantitative characterization of brain lesions and implants

Anatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.

3-D reconstruction↗

Leaf Wax Hydrogen Isotopes Reflect Storm Track Position Over Western North America

Proxy records of past climates have yielded powerful insights into regional hydroclimate dynamics. Novel insights may be gained by reconstructing spatiotemporal changes in precipitation isotopologues in past climate states that cannot be gleaned from individual site‐level studies. In this paper, we ask whether latitudinal gradients in the stable hydrogen isotopic composition of precipitation, as inferred from sedimentary leaf wax biomarkers, reflect aspects of large‐scale climate conditions in western North America (WNA). Modern coretop samples from offshore WNA show that leaf wax hydrogen isotopes broadly track the hydrogen isotopic composition of rainfall between 20 and 40N, but with an offset corresponding to a relatively constant “apparent fractionation” value. Poleward of 40N, the leaf wax signal may be complicated by fluvial transport of leaf waxes from the continental interior. Leaf wax‐inferred precipitation hydrogen isotopes show a shift to more negative values between 30 and 40N. We use modern observational data to show that this latitudinal range marks a major transition between the subtropical arid zone and the location of the midlatitude storm tracks over the northeast Pacific. Nudged water isotope‐enabled models capture the location of the arid to mesic climate transition with fidelity. This modern data set suggests that reconstructions of the latitudinal gradient of precipitation hydrogen isotopes can constrain the sensitivity of the storm tracks to shifts in climatic boundary conditions in past climate states. This approach can yield novel insights into past, present, and future hydroclimate variability in this arid region.

54 ENVIRONMENTAL SCIENCES↗

Metal Identity and Coordination Environment Modulate Single-Atom Catalyst Stability During Electrocatalysis

A major hurdle to the implementation of single-atom catalysts (SACs) in real-world systems is a poor understanding of their stability under operating conditions, which is particularly relevant due to the high surface free energy of SACs. Here, we evaluated the aggregation behavior of a suite of SACs varied by metal identity (Fe, Co, Ni, and Cu) during electrocatalytic nitrate reduction using in situ X-ray absorption spectroscopy. The metal center had significant influence on reconstruction, where under identical applied reductive potentials, SACs underwent varying levels of reconstruction, ranging from no discernible change to complete reduction into metallic nanoparticles. Such in situ experiments revealed Cu SACs to be the most susceptible to aggregation, prompting a deeper investigation into how coordination environment (O-, B-, and N-graphene) affected Cu SAC aggregation. We further conducted density functional theory calculations to elucidate the relationship between Cu SAC structure and stability. This work deconvolutes the relationship between SAC architecture and stability, which is essential to evaluate and explain for the realization of SACs for electrocatalysis.

36 MATERIALS SCIENCE↗

X-ray Computed Tomography Data of Dense Metallic Components

The data shared in here are X-ray computed tomography (XCT) scans of a hexagonal fuel nozzle in 3 sections with the Metrotom 800 system at the Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory. The data are used in the paper "Tomographic Sparse View Selection using the View Covariance Loss, by Lin et al. (doi:10.1109/TPAMI.2025.36000720), accepted to the international conference on computational imaging (ICCP 2025). Figures 4-7 in the paper describe the part/XCT scan. File name Descriptions: Bottom section: TCR- Single Channeled SRC L 2019-3-18 12-26-41.hdf5 Medium section: TCR- Single Channeled SRC M 2019-3-18 13-8-9.hdf5 Top section: TCR- Single Channeled SRC T 2019-3-18 13-45-39.hdf5 Each hdf5 file contains projection data, and all the relevant X-ray CT scan setting. The full list of included attributes: distance_unit: Units of all distances specified angle_unit : Units of the angles angles: Array of all angles used voxel_size_xy: Baseline recon (if any) has this voxel size in the in-plane direction voxel_size_z: Baseline recon (if any) has this voxel size in the cross-plane direction det_pixel_size_col: Size of the detector pixels in the column dimension det_pixel_size_row: Size of the detector pixels in the row dimension src_iso_dist: Source to iso-center distance iso_det_dist: Iso-center to detector distance det_angle: If the detector is rotated/tilted, this angle corresponds to that value det_row_offset: Center of rotation offset in the vertical direction det_col_offset: Center of rotation offset in the horizontal direction reconstruction: A baseline reconstruction stored as 3D array BHC params: Beam-hardening parameters - Van De Casteel Model - if it has been used to pre-process the projections We also provided a python script (hdf_io.py) that allows the user to read the relevant data from each hdf5 file.

Ziabari, Amir [Oak Ridge National Laboratory]↗

Ptychography at all wavelengths

Ptychography is a computational imaging technique that operates across multiple wavelength regimes, from electron (picometres) to X-ray (~0.1 nm), extreme ultraviolet (~10 nm) and visible light (micrometres). By reconstructing both amplitude and phase from diffraction patterns, ptychography enables high-resolution, quantitative imaging without conventional limitations imposed by lens-based optics. Ptychography has enabled advances across a range of scales: achieving deep-sub-angstrom resolution with electron microscopy, becoming an indispensable tool at X-ray synchrotron facilities worldwide and overcoming the trade-offs between resolution and field-of-view in optical imaging. This Primer provides a unified treatment of ptychography across these wavelength regimes. First, we discuss theoretical foundations, reconstruction algorithms, experimental considerations and wavelength-specific challenges. We then give examples of raw and processed data from various configurations and wavelengths. Next, we highlight key applications of ptychography in life sciences, materials science and industry. We also discuss data standards, open-source software implementations and best practices for ensuring reproducibility across different wavelength regimes. Finally, we consider limitations and future opportunities for ptychography. Together with accompanying datasets and code implementations, this Primer aims to serve newcomers and experienced practitioners in the field, facilitating broader adoption of ptychography across different disciplines.

47 OTHER INSTRUMENTATION↗

Emergent surface resonance from charge density wave symmetry breaking in TiSe 2

Surface confined electronic states provide a fertile ground for discovering emergent phenomena that have no counterpart in the bulk, offering new routes to manipulate correlations, symmetry breaking, and dimensionality at the atomic scale. Here, in this study, we show that charge density wave (CDW) symmetry breaking can yield surface states in 1⁢T−TiSe 2 . Micro–angle-resolved photoemission spectroscopy (µ-ARPES) resolves a sharp, two-dimensional surface resonant state (SRS) that emerges within the CDW reconstructed low energy spectrum. The SRS exhibits notable temperature dependence and its spectral weight collapses around ∼ 160 K, while CDW transition temperature 𝑇 CDW is commonly reported as ≈ 202 K. Slab DFT + 𝑈 calculations reproduce a surface localized resonance when CDW folding brings valence and conduction states into near degeneracy, suggesting a correlation tuned, surface selective origin. These results point to a form of correlation-tuned surface resonance in a layered CDW compound and suggest a framework for engineering low-dimensional quantum states in van der Waals materials via symmetry breaking and electronic structure tuning.

36 MATERIALS SCIENCE↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗