Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT SCANNER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dose spread functions in computed tomography: A Monte Carlo study

Purpose: Current CT dosimetry employing CTDI methodology has come under fire in recent years, partially in response to the increasing width of collimated x-ray fields in modern CT scanners. This study was conducted to provide a better understanding of the radiation dose distributions in CT. Methods: Monte Carlo simulations were used to evaluate radiation dose distributions along the z axis arising from CT imaging in cylindrical phantoms. Mathematical cylinders were simulated with compositions of water, polymethyl methacrylate (PMMA), and polyethylene. Cylinder diameters from 10 to 50 cm were studied. X-ray spectra typical of several CT manufacturers (80, 100, 120, and 140 kVp) were used. In addition to no bow tie filter, the head and body bow tie filters from modern General Electric and Siemens CT scanners were evaluated. Each cylinder was divided into three concentric regions of equal volume such that the energy deposited is proportional to dose for each region. Two additional dose assessment regions, central and edge locations 10 mm in diameter, were included for comparisons to CTDI{sub 100} measurements. Dose spread functions (DSFs) were computed for a wide number of imaging parameters. Results: DSFs generally exhibit a biexponential falloff from the z=0 position. For a very narrow primary beam input (<<1 mm), DSFs demonstrated significant low amplitude long range scatter dose tails. For body imaging conditions (30 cm diameter in water), the DSF at the center showed {approx}160 mm at full width at tenth maximum (FWTM), while at the edge the FWTM was {approx}80 mm. Polyethylene phantoms exhibited wider DSFs than PMMA or water, as did higher tube voltages in any material. The FWTM were 80, 180, and 250 mm for 10, 30, and 50 cm phantom diameters, respectively, at the center in water at 120 kVp with a typical body bow tie filter. Scatter to primary dose ratios (SPRs) increased with phantom diameter from 4 at the center (1 cm diameter) for a 16 cm diameter cylinder to {approx}12.5 for a 32 cm diameter cylinder. The SPRs increased dramatically at the center of the phantom compared to the edge. For the three equal area regions, the edge to center SPRs for a 32 cm diameter phantom were {approx}1.8, 3.5, and 6.3, respectively. Conclusions: DSFs demonstrate low amplitude long ranging tails which reach considerable distances in cylindrical phantoms. The buildup that results from these long-ranged tails increases at the center of the field (at z=0) with increasing scan length. The DSF distributions lend a better understanding of the trends in CT dose deposition over a range of relevant imaging parameters. The DSFs as well as other related data are available to interested parties using EPAPS at http://www.aip.org/pubservs/epaps.html.

61 RADIATION PROTECTION AND DOSIMETRY↗

Variations in tumor size and position due to irregular breathing in 4D-CT: A simulation study

Purpose: To estimate the position and volume errors in 4D-CT caused by irregular breathing. Methods: A virtual 4D-CT scanner was designed to reproduce axial mode scans with retrospective resorting. This virtual scanner creates an artificial spherical tumor based on the specifications of the user, and recreates images that might be produced by a 4D-CT scanner using a patient breathing waveform. 155 respiratory waveforms of patients were used to test the variability of 4D-CT scans. Each breathing waveform was normalized and scaled to 1, 2, and 3 cm peak-to-peak motion, and artificial tumors with 2 and 4 cm radius were simulated for each scaled waveform. The center of mass and volume of resorted 4D-CT images were calculated and compared to the expected values of center of mass and volume for the artificial tumor. Intrasubject variability was investigated by running the virtual scanner over different subintervals of each patient's breathing waveform. Results: The average error in the center of mass location of an artificial tumor was less than 2 mm standard deviation for 2 cm motion. The corresponding average error in volume was less than 4%. In the worst-case scenarios, a center of mass error of 1.0 cm standard deviation and volume errors of 30%-60% at inhale were found. Systematic errors were observed in a subset of patients due to irregular breathing, and these errors were more pronounced when the tumor volume is smaller. Conclusions: Irregular breathing during 4D-CT simulation causes systematic errors in volume and center of mass measurements. These errors are small but depend on the tumor size, motion amplitude, and degree of breathing irregularity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant improvements in r{sup ¯} and d{sup ¯}{sub 20} (p < 0.05), with density scaled metrics also showing higher r{sup ¯} than for unscaled versions (p < 0.02). r{sup ¯} and d{sup ¯}{sub 20} were also sensitive to image quality, with statistically significant improvements using standard (as opposed to gated) PET images and with application of median filtering. Conclusions: The use of modified CT ventilation metrics, in conjunction with PET-Galligas and careful application of image filtering has resulted in improved correlation compared to earlier studies using nuclear medicine ventilation. However, CT ventilation and PET-Galligas do not always provide the same functional information. The authors have demonstrated that the agreement can improve for CT ventilation metrics incorporating a tissue density scaling, and also with increasing PET image quality. CT ventilation imaging has clear potential for imaging regional air volume change in the lung, and further development is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of angular and longitudinal tube current modulations on the estimation of organ and effective doses in x-ray computed tomography

Purpose: Tube current modulation (TCM) is one of the recent developments in multislice CT that has proven to reduce the patient radiation dose without affecting the image quality. Presently established methods and published coefficients for estimating organ doses from the dose measured free in air on the axis of rotation or in the CT dose index (CTDI) dosimetry phantoms do not take into account this relatively new development in CT scanner design and technology. Based on these organ dose coefficients effective dose estimates can be made. The estimates are not strictly valid for CT scanning protocols utilizing TCM. In this study, the authors investigated the need to take TCM into account when estimating organ and effective dose values. Methods: A whole-body adult anthropomorphic phantom (Alderson Rando) was scanned with a multislice CT scanner (Somatom Definition, Siemens, Forchheim, Germany) utilizing TCM (CareDose4D). Tube voltage was 120 kV, beam collimation 19.2 mm, and pitch 1. A voxelized patient model was used to define the tissues and organs in the phantom. Tube current values as a function of tube angle were obtained from the raw data for each individual tube rotation of the scan. These values were used together with the Monte Carlo dosimetry tool IMPACTMC (VAMP GmbH, Erlangen, Germany) to calculate organ dose values both with and without account of TCM. Angular and longitudinal modulations were investigated separately. Finally, corresponding effective dose conversion coefficients were determined for both cases according to the updated 2007 recommendations of the ICRP. Results: TCM amplitude was greatest in the shoulder and pelvic regions. Consequently, dose distributions and organ dose values for particular cross sections changed considerably when taking angular modulation into account. The effective dose conversion coefficients were up to 11% lower for a single rotation in the shoulder region and 17% lower in the pelvis when taking angular TCM into account. In the head, neck, thorax, and upper abdominal regions, conversion coefficients changed similarly by only 5% or less. Conversion coefficients for estimating effective doses for scans of complete regions, e.g., chest or abdomen, were approximately 8% lower when taking angular and longitudinal TCMs into account. Conclusions: The authors conclude that for accurate organ and effective dose estimates in individual cross sections in the shoulder or pelvic regions, the angular tube current modulation should be taken into account. In general, using the average of the modulated tube current causes an overestimation of the effective dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report of improved performance in Talbot–Lau phase-contrast computed tomography

Purpose: Many expectations have been raised since the use of conventional x-ray tubes on grating-based x-ray phase-contrast imaging. Despite a reported increase in contrast-to-noise ratio (CNR) in many publications, there is doubt on whether phase-contrast computed tomography (CT) is advantageous in clinical CT scanners in vivo. The aim of this paper is to contribute to this discussion by analyzing the performance of a phase-contrast CT laboratory setup. Methods: A phase-contrast CT performance analysis was done. Projection images of a phantom were recorded, and image slices were reconstructed using standard filtered back projection methods. The resulting image slices were analyzed by determining the CNRs in the attenuation and phase image. These results were compared to analytically calculated expectations according to the already published phase-contrast CT performance analysis by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. There, a severe mistake was found leading to wrong predictions of the performance of phase-contrast CT. The error was corrected and with the new formulae, the experimentally obtained results matched the analytical calculations. Results: The squared ratios of the phase-contrast CNR and the attenuation CNR obtained in the authors’ experiment are five- to ten-fold higher than predicted by Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)]. The effective lateral spatial coherence length deduced outnumbers the already optimistic assumption of Raupach and Flohr [Med. Phys. 39, 4761–4774 (2012)] by a factor of 3. Conclusions: The authors’ results indicate that the assumptions made in former performance analyses are pessimistic. The break-even point, when phase-contrast CT outperforms attenuation CT, is within reach even with realistic, nonperfect gratings. Further improvements to state-of-the-art clinical CT scanners, like increasing the spatial resolution, could change the balance in favor of phase-contrast computed tomography even more. This could be done by, e.g., quantum-counting pixel detectors with four-fold smaller pixel pitches.

60 APPLIED LIFE SCIENCES↗

Characterization of the Martinsburg Formation using Computed Tomography and Geophysical Logging Techniques

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown site were used to characterize 9 different core sections of Upper Ordovician black shale from the Eastern Panhandle of West Virginia. The samples are representative of the upper Ordovician Martinsburg Formation, a Utica Shale equivalent, which is a carbonaceous black shale in the Appalachian Basin. The primary impetus of this work was to develop a standardized methodology for the rapid and detailed characterization of chemical composition, physical characteristics, and internal micro structure of lithologic samples with the NETL core characterization equipment. Having a standardized methodology combining these innovative techniques allows large, rapidly produced data sets to be available for multiple researchers and allows collaborative studies. The resultant data sets are presented as part of this report as well and can be accessed from NETL's Energy Data eXchange (EDX) online system (https://edx.netl.doe.gov) using the following link: https://edx.netl.doe.gov/dataset/martinsburg-formation-ct-data. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores with the additional information gathered through these tests. None of the equipment used was suitable for direct visualization of the shale pore space, though fractures and discontinuities were visible and detectable with all methods tested. High resolution CT imagery with the NETL industrial CT scanner was a powerful and insightful way to examine the details of fractures, discontinuities, minerals, and large crystals within the shale, but was time consuming both in image capture and analysis. As such, only a small percentage of the core was scanned at high resolution. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with the measurements from the multi-sensor core logger (including x-ray fluorescence, XRF, measurements) were very useful in identifying zones of interest for more detailed analysis and fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of all methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations of core that have traditionally been performed at NETL.

47 OTHER INSTRUMENTATION↗

The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: How can we minimize the risk for deterministic effects?

Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peak tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of signal-to-noise ratio mainly to the peripheral region of the phantom. Conclusions: Despite typical peak doses to skin, eye lens, brain, and RBM from the standard low-dose brain perfusion 256-slice CT protocol are well below the corresponding thresholds for the induction of erythema, cataract, cerebrovascular disease, and depression of hematopoiesis, respectively, every effort should be made toward optimization of the procedure and minimization of dose received by these tissues. The current study provides evidence that the use of the narrower bowtie filter available may considerably reduce peak absorbed dose to all above radiosensitive tissues with minimal deterioration in image quality. Considerable reduction in peak eye-lens dose may also be achieved by positioning patient head center a few centimeters above isocenter during the exposure.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-09: Assessment of OSL Dosimeter Technology in the Validation of a Monte Carlo Radiation Transport Code for CT Dosimetry

Purpose: To assess the utility of optically stimulated luminescent (OSL) dosimeter technology in calibrating and validating a Monte Carlo radiation transport code for computed tomography (CT). Methods: Exposure data were taken using both a standard CT 100-mm pencil ionization chamber and a series of 150-mm OSL CT dosimeters. Measurements were made at system isocenter in air as well as in standard 16-cm (head) and 32-cm (body) CTDI phantoms at isocenter and at the 12 o'clock positions. Scans were performed on a Philips Brilliance 64 CT scanner for 100 and 120 kVp at 300 mAs with a nominal beam width of 40 mm. A radiation transport code to simulate the CT scanner conditions was developed using the GEANT4 physics toolkit. The imaging geometry and associated parameters were simulated for each ionization chamber and phantom combination. Simulated absorbed doses were compared to both CTDI{sub 100} values determined from the ion chamber and to CTDI{sub 100} values reported from the OSLs. The dose profiles from each simulation were also compared to the physical OSL dose profiles. Results: CTDI{sub 100} values reported by the ion chamber and OSLs are generally in good agreement (average percent difference of 9%), and provide a suitable way to calibrate doses obtained from simulation to real absorbed doses. Simulated and real CTDI{sub 100} values agree to within 10% or less, and the simulated dose profiles also predict the physical profiles reported by the OSLs. Conclusion: Ionization chambers are generally considered the standard for absolute dose measurements. However, OSL dosimeters may also serve as a useful tool with the significant benefit of also assessing the radiation dose profile. This may offer an advantage to those developing simulations for assessing radiation dosimetry such as verification of spatial dose distribution and beam width.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-A-12A-12: Improved Airway Measurement Accuracy for Low Dose Quantitative CT (qCT) Using Statistical (ASIR), at Reduced DFOV, and High Resolution Kernels in a Phantom and Swine Model

Purpose: Quantitative accuracy of Iodine Hounsfield Unit (HU) in conventional single-kVp scanning is susceptible to beam-hardening effect. Dual-energy CT has unique capabilities of quantification using monochromatic CT images, but this scanning mode requires the availability of the state-of-the-art CT scanner and, therefore, is limited in routine clinical practice. Purpose of this work was to develop a beam-hardening-correction (BHC) for single-kVp CT that can linearize Iodine projections at any nominal energy, apply this approach to study Iodine response with respect to keV, and compare with dual-energy based monochromatic images obtained from material-decomposition using 80kVp and 140kVp. Methods: Tissue characterization phantoms (Gammex Inc.), containing solid-Iodine inserts of different concentrations, were scanned using GE multi-slice CT scanner at 80, 100, 120, and 140 kVp. A model-based BHC algorithm was developed where Iodine was estimated using re-projection of image volume and corrected through an iterative process. In the correction, the re-projected Iodine was linearized using a polynomial mapping between monochromatic path-lengths at various nominal energies (40 to 140 keV) and physically modeled polychromatic path-lengths. The beam-hardening-corrected 80kVp and 140kVp images (linearized approximately at effective energy of the beam) were used for dual-energy material-decomposition in Water-Iodine basis-pair followed by generation of monochromatic images. Characterization of Iodine HU and noise in the images obtained from singlekVp with BHC at various nominal keV, and corresponding dual-energy monochromatic images, was carried out. Results: Iodine HU vs. keV response from single-kVp with BHC and dual-energy monochromatic images were found to be very similar, indicating that single-kVp data may be used to create material specific monochromatic equivalent using modelbased projection linearization. Conclusion: This approach may enable quantification of Iodine contrast enhancement and potential reduction in injected contrast without using dual-energy scanning. However, in general, dual-energy scanning has unique value in material characterization and quantification, and its value cannot be discounted. GE Healthcare Employee.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Explosive Detection in Aviation Applications Using CT

CT scanners are deployed world-wide to detect explosives in checked and carry-on baggage. Though very similar to single- and dual-energy multi-slice CT scanners used today in medical imaging, some recently developed explosives detection scanners employ multiple sources and detector arrays to eliminate mechanical rotation of a gantry, photon counting detectors for spectral imaging, and limited number of views to reduce cost. For each bag scanned, the resulting reconstructed images are first processed by automated threat recognition algorithms to screen for explosives and other threats. Human operators review the images only when these automated algorithms report the presence of possible threats. The US Department of Homeland Security (DHS) has requirements for future scanners that include dealing with a larger number of threats, higher probability of detection, lower false alarm rates and lower operating costs. One tactic that DHS is pursuing to achieve these requirements is to augment the capabilities of the established security vendors with third-party algorithm developers. A third-party in this context refers to academics and companies other than the established vendors. DHS is particularly interested in exploring the model that has been used very successfully by the medical imaging industry, in which university researchers develop algorithms that are eventually deployed in commercial medical imaging equipment. The purpose of this paper is to discuss opportunities for third-parties to develop advanced reconstruction and threat detection algorithms.

42 ENGINEERING↗

PIXE ANALYSIS ON AN ANCIENT SCROLL SAMPLE

For years, scientists have developed several new techniques to read texts of Herculaneum scrolls without destroying them. Recently, the use of a custom built high-resolution CT scanner was proposed to scan and then virtually unroll the scrolls for reading. Identification of any unique chemical signatures in the ancient ink would allow better calibration of the CT scanner to improve the chances of resolving the ink from the burned papyrus background. To support this effort, we carried out one pilot study to see whether the composition of the ink can be obtained from an ancient scroll sample using PIXE technique. PIXE data were collected and analyzed in two different regions of the ancient scroll sample (ink and blank regions). This preliminary work shows that elemental distributions from the ink used in this scroll mainly contained Al, Fe and Ti as well as minor trace amounts of Cr, Cu and Zn.

Environmental Molecular Sciences Laboratory↗

Repeatable and reproducible measurements of myocardial oxidative metabolism, blood flow and external efficiency using {sup 11}C-acetate PET

Background: Non-invasive approaches to investigate myocardial efficiency can help track the progression of heart failure (HF). This study evaluates the repeatability and reproducibility of {sup 11}C-acetate positron emission tomography (PET) imaging of oxidative metabolism. Methods and results: Dynamic {sup 11}C-acetate PET scans were performed at baseline and followup (47 ± 22 days apart) in 20 patients with stable HF with reduced ejection fraction. Two observers blinded to patients’ clinical data used FlowQuant{sup ®} to evaluate test–retest repeatability, as well as intra- and inter-observer reproducibility of {sup 11}C-acetate tracer uptake and clearance rates, for the measurement of myocardial oxygen consumption (MVO{sub 2}), myocardial external efficiency (MEE), work metabolic index (WMI), and myocardial blood flow. Reproducibility and repeatability were evaluated using intra-class-correlation (ICC) and Bland–Altman coefficient-of-repeatability (CR). Test–retest correlations and repeatability were better for MEE and WMI compared to MVO{sub 2}. All intra- and inter-observer correlations were excellent (ICC = 0.95-0.99) and the reproducibility values (CR = 3%-6%) were significantly lower than the test–retest repeatability values (22%-54%, P < 0.001). Repeatability was improved for all parameters using a newer PET–computed tomography (CT) scanner compared to older PET-only instrumentation. Conclusion: {sup 11}C-acetate PET measurements of WMI and MEE exhibited excellent test–retest repeatability and operator reproducibility. Newer PET–CT scanners may be preferred for longitudinal tracking of cardiac efficiency. [French] French Abstract: Contexte: Les examens non invasifs de la fonction myocardique aident à suivre la progression de l’insuffisance cardiaque. Dans ce travail, nous avons évalué la répétabilité et la reproductibilité de l’étude du métabolisme oxydatif du myocarde par imagerie tomographique à positrons avec l’acétate marqué au carbone 11. Méthodes et résultats: Une étude de base et un second examen TEP dynamique à l’ acétate marqué au carbone 11 ont été réalisés (47 ± 22 jours) chez 20 patients présentant une insuffisance cardiaque stable avec une fraction d’éjection réduite. Sans aucune connaissance des données cliniques et au moyen du programme FlowQuant®, deux observateurs ont évalué la répétabilité des TEPs de base et de leur suivi, la reproductibilité intra- et inter-observateur, l’absorption et la clearance du traceur, la mesure de la consommation d’oxygène du myocarde (MVO2), l’efficacité contractile du myocarde (MEE), l’index métabolique du travail myocardique (WMI) et le débit sanguin myocardique (MBF). La reproductibilité et la répétabilité ont été évaluées en utilisant la corrélation intra-classe (ICC) et le coefficient de répétabilité Altman (CR). Les corrélations entre les études de base et leur suivi et la répétabilité des données se sont avérées supérieures pour les paramètres MEE et WMI par rapport à MVO2. Toutes les corrélations intra- et inter-observateurs furent excellentes (ICC = 0,95-0,99). Les valeurs de reproductibilité (CR = 3-6%) furent significativement inférieures aux valeurs de répétabilité (22-54%, p <0.001). La répétabilité des paramètres mesurés s’est avérée supérieure avec un scanner TEP-TDM de nouvelle génération par rapport à l’utilisation de la TEP sans TDM Conclusion: Les mesures réalisées dans cette étude TEP 11C-acétate montre une excellent répétabilité et reproductibilité des paramètres WMI et WMI entre les examens de base et leur suivi effectués par des opérateurs différents. Les nouveaux scanners TEP-TDM devraient être préférés pour le suivi longitudinal de la fonction cardiaque. [Spanish] Spanish Abstract: Antecedentes: el abordaje no invasivo para investigar la eficiencia miocárdica puede ayudar en el seguimiento de la progresión de la insuficiencia cardíaca. Este estudio evalúa la repetibilidad y la reproducibilidad del estudio de metabolismo oxidativo con PET 11C-acetato. Métodos y resultados: Se realizaron estudios de PET 11C-acetato dinámicos al inicio y durante el seguimiento (47 ± 22 días de diferencia) en 20 pacientes con insuficiencia cardíaca estable y fracción de eyección reducida. Dos observadores cegados a los datos clínicos de los pacientes utilizaron FlowQuant® para evaluar la repetibilidad de la prueba-reprueba, así como la reproducibilidad intra e interobservador de la captación de radiotrazador 11C-acetato y sus tasas de eliminación, la medición del consumo miocárdico de oxígeno (MVO2), la eficiencia externa miocardica (EEM), el índice trabajo-metabólico (ITM) y flujo sanguíneo miocárdico (FSM). La reproducibilidad y la repetibilidad se evaluaron mediante la correlación intraclase (ICC) y el coeficiente de repetibilidad (CR) de Bland-Altman. Las correlaciones Prueba-Reprueba y la repetibilidad fueron mejores para la EEM y el ITM en comparación con el MVO2. Todas las correlaciones intra e interobservador fueron excelentes (ICC = 0.95-0.99) y los valores de reproducibilidad (CR = 3-6%) fueron significativamente menores que los valores de repetibilidad prueba-reprueba (22-54%, p <0.001). La repetibilidad fue mejor para todos los parámetros utilizando un equipo PET-TC más nuevo en comparación con un equipo PET sin CT. Conclusión: las mediciones del PET con 11C-acetato del ITM y EEM mostraron una excelente repetibilidad prueba-preprueba y reproducibilidad del operador. Los nuevos equipos PET-CT pueden ser elegidos para el seguimiento longitudinal de la eficiencia miocárdica. [Chinese] Chinese Abstract: 背景: 采用非侵入式方法来研究心肌代谢效率可以帮助追踪心力衰竭的过程。本研究评估利用碳-11 醋酸盐为 PET 显影剂行氧化代谢成像的可重复性和可再现性。 方法和结果: 纳入射血分数减低的 20 名稳定性心衰患者,对患者基线和 47±22 天随访都进行碳-11 醋酸盐 PET 扫描。为测量心肌耗氧量(MVO{sub 2}), 心肌外效率(MEE), 工作代谢指标(WMI)和心肌血流量(MBF), 两名观察者按照双盲的方法利用 FlowQuant®对碳-11 醋酸盐的摄取率和清空率进行了重复性测试以及不同观察者之间的可再现性测试。采用组内相关系数(ICC)和 Bland Altman 可重复性系数(CR)分别对可再现性和可重复性进行评估。MEE 和 WMI 的两次试验系数和可重复性优于MVO{sub 2}。所有观察者之间的相关系数都较好(ICC=0.95-0.99),可再现性系数的值(CR=3-6%)明显低于两次试验可重复性的值(22-54%, P<0.001)。相比于旧的只有 PET 的设备, 采用新型 PET-CT 扫描仪能够使所有参数的可再现性都有所提高。 结论: 碳-11醋酸盐 PET 显像测量 WMI 和 MEE 有很好的可重复性和可再现性。新的 PET-CT 扫描仪可能更适合于心脏代谢效率的长期追踪。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-202-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Evaluation of the Use of Direct Electron Density CT Images in Radiation Therapy

Purpose: The current standard for calculation of photon and electron dose requires conversion of Hounsfield Units (HU) to Electron Density (ED) by applying a calibration curve specifically constructed for the corresponding CT tube voltage. This practice limits the use of the CT scanner to a single tube voltage and hinders the freedom in the selection of optimal tube voltage for better image quality. The objective of this study is to report a prototype CT reconstruction algorithm that provides direct ED images from the raw CT data independently of tube voltages used during acquisition. Methods: A tissue substitute phantom was scanned for Stoichiometric CT calibrations at tube voltages of 70kV, 80kV, 100kV, 120kV and 140kV respectively. HU images and direct ED images were acquired sequentially on a thoracic anthropomorphic phantom at the same tube voltages. Electron densities converted from the HU images were compared to ED obtained from the direct ED images. A 7-field treatment plan was made on all HU and ED images. Gamma analysis was performed to demonstrate quantitatively dosimetric change from the two schemes in acquiring ED. Results: The average deviation of EDs obtained from the direct ED images was −1.5%±2.1% from the EDs from HU images with the corresponding CT calibration curves applied. Gamma analysis on dose calculated on the direct ED images and the HU images acquired at the same tube voltage indicated negligible difference with lowest passing rate at 99.9%. Conclusion: Direct ED images require no CT calibration while demonstrate equivalent dosimetry compared to that obtained from standard HU images. The ability of acquiring direct ED images simplifies the current practice at a safer level by eliminating CT calibration and HU conversion from commissioning and treatment planning respectively. Furthermore, it unlocks a wider range of tube voltages in CT scanner for better imaging quality while maintaining similar dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Dose variations caused by setup errors in intracranial stereotactic radiotherapy: A PRESAGE study

Stereotactic radiotherapy (SRT) requires tight margins around the tumor, thus producing a steep dose gradient between the tumor and the surrounding healthy tissue. Any setup errors might become clinically significant. To date, no study has been performed to evaluate the dosimetric variations caused by setup errors with a 3-dimensional dosimeter, the PRESAGE. This research aimed to evaluate the potential effect that setup errors have on the dose distribution of intracranial SRT. Computed tomography (CT) simulation of a CIRS radiosurgery head phantom was performed with 1.25-mm slice thickness. An ideal treatment plan was generated using Brainlab iPlan. A PRESAGE was made for every treatment with and without errors. A prescan using the optical CT scanner was carried out. Before treatment, the phantom was imaged using Brainlab ExacTrac. Actual radiotherapy treatments with and without errors were carried out with the Novalis treatment machine. Postscan was performed with an optical CT scanner to analyze the dose irradiation. The dose variation between treatments with and without errors was determined using a 3-dimensional gamma analysis. Errors are clinically insignificant when the passing ratio of the gamma analysis is 95% and above. Errors were clinically significant when the setup errors exceeded a 0.7-mm translation and a 0.5° rotation. The results showed that a 3-mm translation shift in the superior-inferior (SI), right-left (RL), and anterior-posterior (AP) directions and 2° couch rotation produced a passing ratio of 53.1%. Translational and rotational errors of 1.5 mm and 1°, respectively, generated a passing ratio of 62.2%. Translation shift of 0.7 mm in the directions of SI, RL, and AP and a 0.5° couch rotation produced a passing ratio of 96.2%. Preventing the occurrences of setup errors in intracranial SRT treatment is extremely important as errors greater than 0.7 mm and 0.5° alter the dose distribution. The geometrical displacements affect dose delivery to the tumor and the surrounding normal tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-25: Determining Tube Current, Tube Voltage and Pitch Suitable for Low- Dose Lung Screening CT

Purpose: The quality of a computed tomography (CT) image and the dose delivered during its acquisition depend upon the acquisition parameters used. Tube current, tube voltage, and pitch are acquisition parameters that potentially affect image quality and dose. This study investigated physicians' abilities to characterize small, solid nodules in low-dose CT images for combinations of current, voltage and pitch, for three CT scanner models. Methods: Lung CT images was acquired of a Data Spectrum anthropomorphic torso phantom with various combinations of pitch, tube current, and tube voltage; this phantom was used because acrylic beads of various sizes could be placed within the lung compartments to simulate nodules. The phantom was imaged on two 16-slice scanners and a 64-slice scanner. The acquisition parameters spanned a range of estimated CTDI levels; the CTDI estimates from the acquisition software were verified by measurement. Several experienced radiologists viewed the phantom lung CT images and noted nodule location, size and shape, as well as the acceptability of overall image quality. Results: Image quality for assessment of nodules was deemed unsatisfactory for all scanners at 80 kV (any tube current) and at 35 mA (any tube voltage). Tube current of 50 mA or more at 120 kV resulted in similar assessments from all three scanners. Physician-measured sphere diameters were closer to actual diameters for larger spheres, higher tube current, and higher kV. Pitch influenced size measurements less for larger spheres than for smaller spheres. CTDI was typically overestimated by the scanner software compared to measurement. Conclusion: Based on this survey of acquisition parameters, a low-dose CT protocol of 120 kV, 50 mA, and pitch of 1.4 is recommended to balance patient dose and acceptable image quality. For three models of scanners, this protocol resulted in estimated CTDIs from 2.9–3.6 mGy.

60 APPLIED LIFE SCIENCES↗

SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. The new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

A method to evaluate the dose increase in CT with iodinated contrast medium

Purpose: The objective of this study is to develop a method to calculate the relative dose increase when a computerized tomography scan (CT) is carried out after administration of iodinated contrast medium, with respect to the same CT scan in absence of contrast medium. Methods: A Monte Carlo simulation in GEANT4 of anthropomorphic neck and abdomen phantoms exposed to a simplified model of CT scanner was set up in order to calculate the increase of dose to thyroid, liver, spleen, kidneys, and pancreas as a function of the quantity of iodine accumulated; a series of experimental measurements of Hounsfield unit (HU) increment for known concentrations of iodinated contrast medium was carried out on a Siemens Sensation 16 CT scanner in order to obtain a relationship between the increment in HU and the relative dose increase in the organs studied. The authors applied such a method to calculate the average dose increase in three patients who underwent standard CT protocols consisting of one native scan in absence of contrast, followed by a contrast-enhanced scan in venous phase. Results: The authors validated their GEANT4 Monte Carlo simulation by comparing the resulting dose increases for iodine solutions in water with the ones presented in literature and with their experimental data obtained through a Roentgen therapy unit. The relative dose increases as a function of the iodine mass fraction accumulated and as a function of the Hounsfield unit increment between the contrast-enhanced scan and the native scan are presented. The data shown for the three patients exhibit an average relative dose increase between 22% for liver and 74% for kidneys; also, spleen (34%), pancreas (28%), and thyroid (48%) show a remarkable average increase. Conclusions: The method developed allows a simple evaluation of the dose increase when iodinated contrast medium is used in CT scans, basing on the increment in Hounsfield units observed on the patients' organs. Since many clinical protocols employ multiple scans at different circulatory phases after administration of contrast medium, such a method can be useful to evaluate the total dose to the patient, also in view of potential clinical protocol optimizations.

60 APPLIED LIFE SCIENCES↗