Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COPPER ALLOY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-temperature, low-cycle fatigue of advanced copper-base alloys for rocket nozzles. Part 2: NASA 1.1, Glidcop, and sputtered copper alloys

Short-term tensile and low-cycle fatigue data are reported for five advance copper-base alloys: Sputtered Zr-Cu as received, sputtered Zr-Cu heat-treated, Glidcop AL-10, and NASA alloys 1-1A and 1-1B. Tensile tests were performed in argon at 538 C using an axial strain rate of 0.002/sec. Yield strength and ultimate tensile strength data are reported along with reduction in area values. Axial strain controlled low-cycle fatigue tests were performed in argon at 538C using an axial strain rate of 0.002/sec to define the fatigue life over the range from 100 to 3000 cycles for the five materials studied. It was found that the fatigue characteristics of the NASA 1-1A and NASA 1-1B compositions are identical and represent fatique life values which are much greater than those for the other materials tested. The effect of temperature on NASA 1-1B alloy at a strain rate of 0.002/sec was evaluated along with the effect of strain rates of 0.0004 and 0.01/sec at 538 C. Hold-time data are reported for the NASA 1-1B alloy at 538 C using 5 minute hold periods in tension only and compression only at two different strain range values. Hold periods in tension were much more detrimental than hold periods in compression.

Conway, J. B.↗

Role of alloying elements in adhesive transfer and friction of copper-base alloys

Sliding friction experiments were conducted in a vacuum with binary-copper alloy riders sliding against a conventional bearing-steel surface with normal residual oxides present. The binary alloys contained 1 atomic percent of various alloying elements. Auger spectroscopy analysis was used to monitor the adhesive transfer of the copper alloys to the bearing-steel surface. A relation was found to exist between adhesive transfer and the reaction potential and free energy of formation of the alloying element in the copper. The more chemically active the element and the more stable its oxide, the greater was the adhesive transfer and wear of the copper alloy. Transfer occurred in all the alloys except copper-gold after relatively few (25) passes across the steel surface.

Buckley, D. H.↗

Casting Development Report for EFF-W Casting Furnace

The Experimental Fuels Facility (EFF) Casting System, which is configured for gravity casting into a permanent mold, was installed to cast billets made up of uranium, uranium alloys, copper and copper alloys, as well as other geometries in support of the TerraPower project. This document describes casting development using.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid-Phase Surface Alloying of Copper with Stainless Steel Using Low-Energy, High-Current Electron Beam

The paper deals with the formation of the stainless steel-copper surface alloy which occurs during the single vacuum cycle. Deposition of the stainless steel film onto a copper substrate is performed via successive magnetron sputtering followed by its liquid-phase mixing with copper using the low-energy, high-current electron beam of microsecond length. Numerical calculations are used to identify the optimum irradiation modes for the surface alloying. It is found that the optimum irradiation modes provide the homogeneous surface alloying, and the copper concentration in the obtained layer increases with the increase in energy density of the low-energy, high-current electron beam. The formation of the stainless steel-copper surface alloy increases the wear resistance of copper specimens by 7.5 times as compared to the original specimens. In addition, it is ascertained that the wear resistance of the surface alloy exceeds that of the common film coating (1 μm) more than 5 times.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High temperature, low-cycle fatigue of copper-base alloys in argon. Part 2: Zirconium-copper at 482, 538 and 593 C

Zirconium-copper (1/2 hard) was tested in argon over the temperature range from 482 to 593 C in an evaluation of short-term tensile and low-cycle fatigue behavior. The effect of strain rate on the tensile properties was evaluated at 538 C and in general it was found that the yield and ultimate strengths increased as the strain rate was increased from 0.0004 to 0.01/sec. Ductility was essentially insensitive to strain rate in the case of the zirconium-copper alloy. Strain-rate and hold-time effects on the low cycle fatigue behavior of zirconium-copper were evaluated in argon at 538 C. These effects were as expected in that decreased fatigue life was noted as the strain rate decreased and when hold times were introduced into the tension portion of the strain-cycle. Hold times in compression were much less detrimental than hold times in tension.

Conway, J. B.↗

High tensile alloy of copper to mitigate current collector deformation in silicon electrodes for lithium-ion batteries

The volumetric changes of silicon electrodes, along with the strong adhesive properties of certain binders, can lead to plastic deformation of the current collector and create damage in the electrode coating. Here, in this study, we report a detailed study of silicon coatings on a high-tensile alloy (HTA) foil of copper with strength over twice that of conventional copper foils. The HTA current collectors with high mechanical strength can mitigate plastic deformation upon continuous cycling. At moderate areal capacities (2.5–3 mAh cm −2 ), conventional copper foils show significant wrinkling after only a few electrochemical cycles, whereas the HTA foils remain intact. We demonstrate viability of the HTA foils in large format xx6395 pouch cells, in which the HTA current collectors remain intact even at an areal capacity of 4.5 mAh cm −2 ; in contrast, wrinkles form in conventional copper current collectors increasing the likelihood of lithium plating. Computational studies show that stresses generated during cycling of silicon electrodes are very high in the current collector and at the current collector-coating interface, explaining the wrinkling of conventional Cu foils. Our studies highlight importance of current collector to solve the electrochemical and chemo-mechanical performance challenges associated with high-loading silicon electrodes.

Chemo-mechanical degradation↗

A visualization instrument to investigate the mechanical-electro properties of high temperature superconducting tapes under multi-fields

We construct a visible instrument to study the mechanical-electro behaviors of high temperature superconducting tape as a function of magnetic field, strain, and temperature. This apparatus is directly cooled by a commercial Gifford-McMahon cryocooler. The minimum temperature of sample can be 8.75 K. A proportion integration differentiation temperature control is used, which is capable of producing continuous variation of specimen temperature from 8.75 K to 300 K with an optional temperature sweep rate. We use an external loading device to stretch the superconducting tape quasi-statically with the maximum tension strain of 20%. A superconducting magnet manufactured by the NbTi strand is applied to provide magnetic field up to 5 T with a homogeneous range of 110 mm. The maximum fluctuation of the magnetic field is less than 1%. We design a kind of superconducting lead composed of YBa2Cu3O7-x coated conductor and beryllium copper alloy (BeCu) to transfer DC to the superconducting sample with the maximum value of 600 A. Most notably, this apparatus allows in situ observation of the electromagnetic property of superconducting tape using the classical magnetic-optical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the gaseous hydrogen ductile-brittle transition in copper-nickel alloys

A series of copper-nickel alloys were fabricated, notched tensile specimens machined for each alloy, and the specimens tested in 34.5 MPa hydrogen and in air. A notched tensile ratio was determined for each alloy and the hydrogen environment embrittlement (HEE) determined for the alloys of 47.7 weight percent nickel to 73.5 weight percent nickel. Stacking fault probability and stacking fault energies were determined for each alloy using the x ray diffraction line shift and line profiles technique. Hydrogen environment embrittlement was determined to be influenced by stacking fault energies; however, the correlation is believed to be indirect and only partially responsible for the HEE behavior of these alloys.

Parr, R. A.↗

Eutectic structures in friction spot welding joint of aluminum alloy to copper

A dissimilar joint of AA5083 Al alloy and copper was produced by friction spot welding. The Al-MgCuAl{sub 2} eutectic in both coupled and divorced manners were found in the weld. At a relatively high temperature, mass transport of Cu due to plastic deformation, material flow, and atomic diffusion, combined with the alloy system of AA5083 are responsible for the ternary eutectic melting.

36 MATERIALS SCIENCE↗

Calculation of binodals and spinodals in multicomponent alloys by different statistical methods with application to iron-copper-manganese alloys

A generalization of the pair-cluster (PC) approximation in the theory of disordered systems to multicomponent alloys is proposed. It is shown that phase equilibrium boundaries (binodals) calculated in the mean-field (MF) approximation, which is used in standard calculations of phase diagrams by the CALPHAD method, coincide with the results of rigorous calculations for dilute alloys; however, the application of these methods to calculating the boundaries of the stability region with respect to the decomposition of an alloy (spinodals) leads to large errors. At the same time, in the PC approximation, the description of all statistical properties, including binodals and spinodals, turns out to be exact for dilute alloys. The methods developed are illustrated by an example of iron-copper-manganese ternary alloys.

36 MATERIALS SCIENCE↗

Determining the Force Exerted by a Stepped Punch

The relative pressure in the cold extrusion of hollow cylindrical aluminum- and copper-alloy parts by a stepped punch is determined experimentally. A mathematical model of the process is derived.

42 ENGINEERING↗

NiAl Coatings Investigated for Use in Reusable Launch Vehicles

As part of its major investment in the area of advanced space transportation, NASA is developing new technologies for use in the second- and third-generation designs of reusable launch vehicles. Among the prototype rocket engines being considered for these launch vehicles are those designed to use liquid hydrogen as the fuel and liquid oxygen as the oxidizer. Advanced copper alloys, such as copper-chromium-niobium (Cu-8(at.%)Cr- 4(at.%)Nb, also referred to as GRCop-84), which was invented at the NASA Glenn Research Center, are being considered for use as liner materials in the combustion chambers and nozzle ramps of these engines. However, previous experience has shown that, in rocket engines using liquid hydrogen and liquid oxygen, copper alloys are subject to a process called blanching, where the material undergoes environmental attack under the action of the combustion gases. In addition, the copper alloy liners undergo thermomechanical fatigue, which often results in an initially square cooling channel deforming into a dog-house shape. Clearly, there is an urgent need to develop new coatings to protect copper liners from environmental attack inside rocket chambers and to lower the temperature of the liners to reduce the probability of deformation and failure by thermomechanical fatigue.

Raj, Sai V.↗

High temperature, low cycle fatigue of copper-base alloys in argon. Part 3: Zirconium-copper; thermal-mechanical strain cycling, hold-time and notch fatigue results

The low-cycle fatigue characteristics of smooth bar and notched bar specimens (hourglass shape) of zirconium-copper, 1/2 Hard, material (R-2 Series) were evaluated at room temperature in axial strain control. Over the fatigue life range from about 300 to 3000 cycles the ratio of fatigue life for smooth bar to fatigue life for notched bar remained constant at a value of about 6.0. Some additional hold-time data for the R-2 alloy tested in argon at 538 C are reported. An analysis of the relaxation data obtained in these hold-time tests is also reported and it is shown that these data yield a fairly consistent correlation in terms of instantaneous stress rate divided by instantaneous stress. Two thermal-mechanical strain cycling tests were also performed using a cyclic frequency of 4.5 cycles per hour and a temperature cycling interval from 260 to 538 C. The fatigue life values in these tests were noticeably lower than that observed in isothermal tests at 538 C.

Conway, J. B.↗