Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COPPER 72”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The materials irradiation experiment for testing plasma facing materials at fusion relevant conditions

The Materials Irradiation Experiment (MITE-E) was constructed at the University of Wisconsin-Madison Inertial Electrostatic Confinement Laboratory to test materials for potential use as plasma-facing materials (PFMs) in fusion reactors. PFMs in fusion reactors will be bombarded with x-rays, neutrons, and ions of hydrogen and helium. More needs to be understood about the interactions between the plasma and the materials to validate their use for fusion reactors. The MITE-E simulates some of the fusion reactor conditions by holding samples at temperatures up to 1000 °C while irradiating them with helium or deuterium ions with energies from 10 to 150 keV. The ion gun can irradiate the samples with ion currents of 20 μA–500 μA; the typical current used is 72 μA, which is an average flux of 9 × 10{sup 14} ions/(cm{sup 2} s). The ion gun uses electrostatic lenses to extract and shape the ion beam. A variable power (1-20 W), steady-state, Nd:YAG laser provides additional heating to maintain a constant sample temperature during irradiations. The ion beam current reaching the sample is directly measured and monitored in real-time during irradiations. The ion beam profile has been investigated using a copper sample sputtering experiment. The MITE-E has successfully been used to irradiate polycrystalline and single crystal tungsten samples with helium ions and will continue to be a source of important data for plasma interactions with materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining CO coverage on copper promotes high-efficiency ethylene electroproduction

The availability of inexpensive industrial CO gas streams motivates efficient electrocatalytic upgrading of CO to higher-value feedstocks such as ethylene. However, the electrosynthesis of ethylene by the CO reduction reaction (CORR) has suffered from low selectivity and energy efficiency. Here we find that the recent strategy of increasing performance through use of highly alkaline electrolyte—which is very effective in CO 2 RR—fails in CORR and drives the reaction to acetate. We then observe that ethylene selectivity increases when we constrain (decrease) CO availability. Using density functional theory, we show how CO coverage on copper influences the reaction pathways of ethylene versus oxygenate: lower CO coverage stabilizes the ethylene-relevant intermediates whereas higher CO coverage favours oxygenate formation. We then control local CO availability experimentally by tuning the CO concentration and reaction rate; we achieve ethylene Faradaic efficiencies of 72% and a partial current density of >800 mA cm -2 . The overall system provides a half-cell energy efficiency of 44% for ethylene production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-fast hadronic calorimetry

Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper the time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-scintillator hadronic calorimeter. In the beam tests, scintillator signals induced by hadronic showers in steel are sampled with a period of 0.2 ns and precisely time-aligned in order to study the average signal waveform at various locations with respect to the beam particle impact. Simulations of the same setup are performed using the MARS15 code. Both simulation and test beam results suggest that energy deposition in steel calorimeters develop over a time shorter than 2 ns providing opportunity for ultra-fast calorimetry. As a result, simulation results for an “ideal” calorimeter consisting exclusively of bulk tungsten or copper are presented to establish the lower limit of the signal integration window.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Centrality, rapidity, and transverse-momentum dependence of cold nuclear matter effects on J/psi production in dAu, CuCu, and AuAu collisions at sq root(s{sub NN})=200 GeV

We have carried out a wide study of cold nuclear matter (CNM) effects on J/psi production in dAu, CuCu and AuAu collisions at sq root(s{sub NN})=200 GeV. We have studied the effects of three different gluon-shadowing parametrizations, using the usual simplified kinematics for which the momentum of the gluon recoiling against the J/psi is neglected as well as an exact kinematics for a 2->2 process; namely g+g->J/psi+g as expected from LO pQCD. We have shown that the rapidity distribution of the nuclear modification factor R{sub dAu}, and particularly its antishadowing peak, is systematically shifted toward larger rapidities in the 2->2 kinematics, irrespective of which shadowing parametrization is used. In turn, we have noted differences in the effective final-state nuclear absorption needed to fit the PHENIX dAu data. Taking advantage of our implementation of 2->2 kinematics, we have also computed the transverse momentum dependence of the nuclear modification factor, which cannot be predicted with the usual simplified kinematics. All the corresponding observables have been computed for CuCu and AuAu collisions and compared to the PHENIX and STAR data. Finally, we have extracted the effective nuclear absorption from the recent measurements of R{sub CP} in dAu collisions by the PHENIX collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vector-current correlation and charge separation via the chiral-magnetic effect

We investigate the vector-current correlation {Pi}{sub {mu}{nu}}(VCC) in the presence of a strong external magnetic field (B=B{sub 0} in the z direction) at low temperature (T < or approx. T{sub c}{sup {chi}}) with P and CP violations, indicated by the nonzero chiral-chemical potential ({mu}{sub {chi}{ne}0}), i.e. the chiral-magnetic effect (CME). For this purpose, we employ the instanton-vacuum configuration at finite T with nonzero topological charge (Q{sub t{ne}}0). We also consider a simple estimation for the nonzero-mode contributions to the quark propagator, in addition to the zero-mode approximation. From the numerical calculations, it turns out that the longitudinal component of the connected VCC is linear in B{sub 0} and shows a bump, representing a corresponding vector meson at |Q|=(300{approx}400) MeV for T=0. The bump becomes enhanced as T increases and the bump position shifts to a lager |Q| value. In the limit of |Q|{yields}0, the transverse component of the connected VCC disappears, whereas the longitudinal one remains finite and becomes insensitive to B{sub 0} with respect to T, due to diluting instanton contributions. Considering the simple collision geometry of heavy-ion collision and some assumptions on the induced magnetic field and screening effect, we can estimate the charge separation as a function of centrality using the present results for the VCC. The numerical results show a qualitative agreement with experiments for the Au+Au and Cu+Cu collisions. These results are almost independent on the source of the CME, instanton, or sphaleron, as long as the CME current is linear in B{sub 0}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm × 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Ir-Mn composition on exchange bias and thermal stability of spin valves with nano-oxide layers

The Ir-Mn bottom-pinned spin valves with nano-oxide layers (NOLs), Ta/Ni{sub 81}Fe{sub 19}/Ir-Mn/Co{sub 90}Fe{sub 10}/NOL/Co{sub 90}Fe{sub 10}/Cu/Co{sub 90}Fe{sub 10}/NOL/Ta, were fabricated by dc magnetron sputtering. The magnetoresistance (MR), magnetization, and exchange bias have been studied as a function of Ir-Mn composition and annealing temperature. It was observed that the spin valves with the Ir-Mn layer containing relatively low Mn content (58.9-72.4 at. % Mn) show the best thermal endurance. For these samples, the Mn diffusion is effectively hampered by the NOL with a large MR value of about 12.5% even after annealing at 300 deg. C. On the other hand, the exchange bias field of the pinned CoFe layer shows a maximum at Mn content of about 72.4 at. %, which is different from the widely adopted composition, Ir-80 at. % Mn, optimized from the top-pinned NiFe/Ir-Mn system. Moreover, the blocking temperature of the Ir-Mn/CoFe system with 72.4 at. % Mn is higher than that with 80.6 at. % Mn. The present results suggest that the Ir-Mn/CoFe pinning system with Mn content at about 72% renders the most favorable exchange bias and the best thermal stability for the bottom-pinned specular spin valves.

36 MATERIALS SCIENCE↗

Ti{sub 3}CrCu{sub 4}: A possible 2-D ferromagnetic spin fluctuating system

Ti{sub 3}CrCu{sub 4} is a new ternary compound which crystallizes in the tetragonal Ti{sub 3}Pd{sub 5} structure type. The Cr atoms form square nets in the a-b plane (a = 3.124 Å) which are separated by an unusually large distance c = 11.228 Å along the tetragonal axis, thus forming a -2-D Cr-sublattice. The paramagnetic susceptibility is characterized by a low effective moment, μ{sub eff} = 1.1 μ{sub B}, a low paramagnetic Curie temperature θ{sub P} (below 7 K) and a temperature independent χ{sub 0} = 6.7 x 10{sup −4} emu/mol. The magnetization at 1.8 K increases rapidly with field nearly saturating to 0.2 μ{sub B}/f.u. The zero field heat capacity C/T shows an upturn below 7 K (∼190 mJ/mol K{sup 2} at ∼0.1K) which is suppressed in applied magnetic fields and interpreted as suggesting the presence of spin fluctuations. The resistivity at low temperatures shows non-Fermi liquid behavior. Overall, the experimental data thus reveal an unusual magnetic state in Ti{sub 3}CrCu{sub 4}, which likely has its origin in the layered nature of the Cr sub-lattice and ferromagnetic spin fluctuations. Density functional theoretical calculations reveal a sharp Cr density of states peak just above the Fermi level, indicating the propensity of Ti{sub 3}CrCu{sub 4} to become magnetic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of dissimilar metal welds by energy-resolved neutron imaging

A nondestructive study of the internal structure and compositional gradient of dissimilar metal-alloy welds through energy-resolved neutron imaging is described in this paper. The ability of neutrons to penetrate thick metal objects (up to several cm) provides a unique possibility to examine samples which are opaque to other conventional techniques. The presence of Bragg edges in the measured neutron transmission spectra can be used to characterize the internal residual strain within the samples and some microstructural features, e.g. texture within the grains, while neutron resonance absorption provides the possibility to map the degree of uniformity in mixing of the participating alloys and intermetallic formation within the welds. In addition, voids and other defects can be revealed by the variation of neutron attenuation across the samples. This paper demonstrates the potential of neutron energy-resolved imaging to measure all these characteristics simultaneously in a single experiment with sub-mm spatial resolution. Two dissimilar alloy welds are used in this study: Al autogenously laser welded to steel, and Ti gas metal arc welded (GMAW) to stainless steel using Cu as a filler alloy. The cold metal transfer variant of the GMAW process was used in joining the Ti to the stainless steel in order to minimize the heat input. The distributions of the lattice parameter and texture variation in these welds as well as the presence of voids and defects in the melt region are mapped across the welds. The depth of the thermal front in the Al–steel weld is clearly resolved and could be used to optimize the welding process. As a result, a highly textured structure is revealed in the Ti to stainless steel joint where copper was used as a filler wire. The limited diffusion of Ti into the weld region is also verified by the resonance absorption.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{phi}-meson production and the in-medium {phi}-width in proton-nucleus collisions

The production of {phi}-mesons in collisions of 2.83 GeV protons with C, Cu, Al, and Au targets has been measured with the ANKE magnetic spectrometer at the Cooler Synchrotron COSY. The {phi}-mesons were detected at small angles via their K{sup +}K{sup -} decay. The measured target mass dependence of the production cross section can be related to the in-medium {phi} width. First comparisons with model calculations suggest a significant broadening of the {phi}-width relative to its vacuum value of 4.3 MeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam-energy and system-size dependence of dynamical net charge fluctuations

We present measurements of net charge fluctuations in Au+Au collisions at {radical}(s{sub NN})=19.6, 62.4, 130, and 200 GeV, Cu+Cu collisions at {radical}(s{sub NN})=62.4 and 200 GeV, and p+p collisions at {radical}(s)=200 GeV using the dynamical net charge fluctuations measure {nu}{sub +-,dyn}. We observe that the dynamical fluctuations are nonzero at all energies and exhibit a modest dependence on beam energy. A weak system size dependence is also observed. We examine the collision centrality dependence of the net charge fluctuations and find that dynamical net charge fluctuations violate 1/N{sub ch} scaling but display approximate 1/N{sub part} scaling. We also study the azimuthal and rapidity dependence of the net charge correlation strength and observe strong dependence on the azimuthal angular range and pseudorapidity widths integrated to measure the correlation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence for a gapped spin-liquid ground state in a kagome Heisenberg antiferromagnet

Here, the kagome Heisenberg antiferromagnet is a leading candidate in the search for a spin system with a quantum spin-liquid ground state. The nature of its ground state remains a matter of active debate. We conducted oxygen-17 single-crystal nuclear magnetic resonance (NMR) measurements of the spin-1/2 kagome lattice in herbertsmithite [ZnCu 3 (OH) 6 Cl 2 ], which is known to exhibit a spinon continuum in the spin excitation spectrum. We demonstrated that the intrinsic local spin susceptibility χkagome, deduced from the oxygen-17 NMR frequency shift, asymptotes to zero below temperatures of 0.03J, where J ~ 200 kelvin is the copper-copper superexchange interaction. Combined with the magnetic field dependence of χ kagome that we observed at low temperatures, these results imply that the kagome Heisenberg antiferromagnet has a spin-liquid ground state with a finite gap.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the equation of state of solid-density copper heated with laser-accelerated protons

We present equation of state (EOS) measurements of solid-density copper heated to 5–10 eV. A copper sample was heated isochorically by hydrogen ions accelerated from an adjacent foil by a high intensity pulsed laser, and probed optically. The measured temperature and expansion are compared against simulations using the most up-to-date wide range EOS tables available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charm and beauty searches using electron -D{sup 0} azimuthal correlations and microvertexing techniques in STAR experiment at RHIC

The energy loss of heavy quarks in the hot and dense matter created at RHIC, can be used to probe the properties of the medium. Both charm and beauty quarks contribute to the non-photonic electrons through their semi-leptonic decays. It is essential to determine experimentally the relative contribution of charm and beauty quarks to understand the suppression of heavy flavors at high p{sub T} in central Au+Au collisions. The azimuthal angular correlations of non-photonic electrons with the reconstructed D{sup 0} allow to disentangle the contribution of charm and beauty and to reduce the background below the D{sup 0} invariant mass as well. We discuss the STAR measurement of non-photonic electron and D{sup 0{yields}}K{sup -{pi}+} azimuthal correlations in p+p collisions at 200 GeV. Furthermore, we show results from the application of microvertexing techniques for charm and beauty searches in Cu+Cu and Au+Au collisions at 200 GeV using the information of the Silicon tracker of STAR.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Data Sheets for A = 58

The evaluated spectroscopic data are presented for known nuclides of mass 58 (Ca,Sc,Ti,V,Cr,Mn,Fe,Co,Ni,Cu,Zn). Excited-state data are nonexistent for {sup 58}Ca, {sup 58}Sc, and {sup 58}Zn; and very scarce for {sup 58}Ti and {sup 58}V, with only one tentative level in each case. Except for half-lives, no other radioactive decay data are available for the decay of {sup 58}Sc and {sup 58}Ti. The radioactive decays of {sup 58}V, {sup 58}Cr and {sup 58}Zn are not considered as well established. Superdeformed structures are known in {sup 58}Ni (two bands) and in {sup 58}Cu (one band). Prompt proton decay of high-spin states in 58Ni for eight levels and prompt {alpha} decay for two states have been identified. In {sup 58}Cu, one high-spin state decays by prompt proton emission. Very complex high-spin structures are now known for {sup 58}Ni from the work by 2009Jo03.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System-Size Independence of Directed Flow Measured at the BNL Relativistic Heavy-Ion Collider

We measure directed flow (v{sub 1}) for charged particles in Au+Au and Cu+Cu collisions at {radical}(s{sub NN})=200 and 62.4 GeV, as a function of pseudorapidity ({eta}), transverse momentum (p{sub t}), and collision centrality, based on data from the STAR experiment. We find that the directed flow depends on the incident energy but, contrary to all available model implementations, not on the size of the colliding system at a given centrality. We extend the validity of the limiting fragmentation concept to v{sub 1} in different collision systems, and investigate possible explanations for the observed sign change in v{sub 1}(p{sub t})

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-I-72: First Experimental Study of On-Board CBCT Imaging Using 2.5MV Beam On a Radiotherapy Linac

Purpose: Varian TrueBeam version 2.0 comes with a new inline 2.5MV beam modality for image guided patient setup. In this work we develop an iterative volumetric image reconstruction technique specific to the beam and investigate the possibility of obtaining metal artifact free CBCT images using the new imaging modality. Methods: An iterative reconstruction algorithm with a sparse representation constraint based on dictionary learning is developed, in which both sparse projection and low dose rate (10 MU/min) are considered. Two CBCT experiments were conducted using the newly available 2.5MV beam on a Varian TrueBeam linac. First, a Rando anthropomorphic head phantom with and without a copper bar inserted in the center was scanned using both 2.5MV and kV (100kVp) beams. In a second experiment, an MRI phantom with many coils was scanned using 2.5MV, 6MV, and kV (100kVp) beams. Imaging dose and the resultant image quality is studied. Results: Qualitative assessment suggests that there were no visually detectable metal artifacts in MV CBCT images, compared with significant metal artifacts in kV CBCT images, especially in the MRI phantom. For a region near the metal object in the head phantom, the 2.5MV CBCT gave a more accurate quantification of the electron density compared with kV CBCT, with a ∼50% reduction in mean HU error. As expected, the contrast between bone and soft-tissue in 2.5MV CBCT decreased compared with kV CBCT. Conclusion: On-board CBCT imaging with the new 2.5MV beam can effectively reduce metal artifacts, although with a reduced softtissue contrast. Combination of kV and MV scanning may lead to metal artifact free CBCT images with uncompromised soft-tissue contrast.

60 APPLIED LIFE SCIENCES↗

J/{psi} Production in {radical}(s{sub NN})=200 GeV Cu+Cu Collisions

Yields for J/{psi} production in Cu+Cu collisions at {radical}(s{sub NN})=200 GeV have been measured over the rapidity range |y|<2.2 and compared with results in p+p and Au+Au collisions at the same energy. The Cu+Cu data offer greatly improved precision over existing Au+Au data for J/{psi} production in collisions with small to intermediate numbers of participants, in the range where the quark-gluon plasma transition threshold is predicted to lie. Cold nuclear matter estimates based on ad hoc fits to d+Au data describe the Cu+Cu data up to N{sub part}{approx}50, corresponding to a Bjorken energy density of at least 1.5 GeV/fm{sup 3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗