Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTROLLED AREAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Stochastic Characterization of Communication Network Latency for Wide Area Grid Control Applications.

This report characterizes communications network latency under various network topologies and qualities of service (QoS). The characterizations are probabilistic in nature, allowing deeper analysis of stability for Internet Protocol (IP) based feedback control systems used in grid applications. The work involves the use of Raspberry Pi computers as a proxy for a controlled resource, and an ns-3 network simulator on a Linux server to create an experimental platform (testbed) that can be used to model wide-area grid control network communications in smart grid. Modbus protocol is used for information transport, and Routing Information Protocol is used for dynamic route selection within the simulated network.

97 MATHEMATICS AND COMPUTING↗

Wide-area, real-time monitoring and visualization system

A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

47 OTHER INSTRUMENTATION↗

Wide-area, real-time monitoring and visualization system

A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PDCI Wide-Area Damping Control: PSLF Simulations of the 2016 Open and Closed Loop Test Plan

To demonstrate and validate the performance of the wide-are a damping control system, the project plans to conduct closed-loop tests on the PDCI in summer/fall 2016. A test plan details the open and closed loop tests to be conducted on the P DCI using the wide-area damping control system. To ensure the appropriate level of preparedness, simulations were performed in order to predict and evaluate any possible unsafe operations before hardware experiments are attempted. This report contains the result s from these simulations using the power system dynamics software PSLF (Power System Load Flow, trademark of GE). The simulations use the WECC (Western Electricity Coordinating Council) 2016 light summer and heavy summer base cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dissipativity-based design of local and wide-area DER controls for large-scale power systems with high penetration of renewables

In this paper, an integrated and modular control design is developed for distributed energy resources (DERs) to stabilize power systems and minimize effects of load variations and intermittent generation. Traditionally, the droop control of each generator (or virtual power plant) works as a local feedback loop to track frequency during load disturbance, whereas automatic generation control (AGC) calculates control signals and sends them to each generator with the goal of matching the total generation and load in the overall system. The droop control and the AGC work separately, therefore the two controls often conflict each other. The proposed design enables us to modularly synthesize an integrated control for each of the DERs by using both local and wide-area measurements so that the controls work together in enhancing stability and performance of the power system. The design methodology admits the full nonlinear power flow equations, and it results in a data-driven control that in real-time takes into account the nonlinear power flow interactions (in terms of current angle measurements) and adaptively adjusts parameters of the controls that operate the DERs. The design framework uses the concept of passivity-short systems to analyze individual DERs and quantify their dynamic responses in such a way that the resulting system-wide implementation becomes plug-and-play. Simulations are done to demonstrate the effectiveness of the proposed methodology and design.

Harvey, Roland↗

Risk of carotid atherosclerosis is associated with low serum paraoxonase (PON1) activity among arsenic exposed residents in Southwestern Taiwan

To understand whether human paraoxonase 1 (PON1) would modulate the risk for arsenic-related atherosclerosis, we studied 196 residents from an arseniasis-endemic area in Southwestern Taiwan and 291 age- and sex-matched residents from a nearby control area where arsenic exposure was found low. Carotid atherosclerosis was defined by a carotid artery intima-media wall thickness (IMT) of > 1.0 mm. Prevalence of carotid atherosclerosis was increased in the arseniasis-endemic area as compared to the control area after adjustment for conventional risk factors (OR = 2.20, p < 0.01). The prevalence was positively associated with cumulative arsenic exposure (mg/L-year) in a dose-dependent manner. Multiple logistic regression analysis showed that in the endemic group, low serum PON1 activity was an independent risk factor for atherosclerosis (OR = 4.18 low vs. high, p < 0.05). For those of low PON1 activity and high cumulative arsenic exposure, the odds ratio for the prevalence of atherosclerosis was further increased up to 5.68 (p < 0.05). No significant association was found between atherosclerosis and four polymorphisms of the PON gene cluster (PON1 - 108C/T, PON1 Q192R, PON2 A148G, PON2 C311S). However, genetic frequencies of certain alleles including PON1 Q192, PON2 G148 and PON2 C311 were found increased in the endemic group as compared to the controls and a general Chinese population, indicating a possible survival selection in the endemic group after a long arsenic exposure history. Our results showed a significant joint effect between arsenic exposure and serum PON1 activity on carotid atherosclerosis, suggesting that subjects of low PON1 activity may be more susceptible to arsenic-related cardiovascular disease.

60 APPLIED LIFE SCIENCES↗

Heavy-Duty Vehicle Port Drayage Drive Cycle Characterization and Development

In an effort to better understand the operational requirements of port drayage vehicles and their potential for adoption of advanced technologies, National Renewable Energy Laboratory (NREL) researchers collected over 36,000 miles of in-use duty cycle data from 30 Class 8 drayage trucks operating at the Port of Long Beach and Port of Los Angeles in Southern California. These data include 1-Hz global positioning system location and SAE J1939 high-speed controller area network information. Researchers processed the data through NREL's Drive-Cycle Rapid Investigation, Visualization, and Evaluation tool to examine vehicle kinematic and dynamic patterns across the spectrum of operations. Using the k-medoids clustering method, a repeatable and quantitative process for multi-mode drive cycle segmentation, the analysis led to the creation of multiple drive cycles representing four distinct modes of operation that can be used independently or in combination. These drive cycles are statistically representative of real-world operation of port drayage vehicles. When combined with modeling and simulation tools, these representative test cycles allow advanced vehicle or systems developers to efficiently and accurately evaluate vehicle technology performance requirements to reduce cost and development time while ultimately leading to the commercialization of advanced technologies that meet the performance requirements of the port drayage vocation. The drive cycles, which are suitable for chassis dynamometer testing, were compared to several existing test cycles. This paper presents the clustering methodology, accompanying results of the port drayage duty cycle analysis and custom drive cycle creation.

33 ADVANCED PROPULSION SYSTEMS↗

Mix/Cast Contamination Control

Presented is a training handbook for Mix/Cast Contamination Control; a part of a series of training courses to qualify access to Mix/Cast facilities. Contents: List Contamination Control Requirements; Identify foreign objects debris (FOD), Control Areas and their guidelines; Describe environmental monitoring; List Contamination Control Initiatives; Describe concern for Controlled Materials; Identify FOD Controlled Areas in Mix/Cast.

Wallentine, M.↗

Clearance Measurements prior to the Shut-Down of ERAM

Low and intermediate level radioactive waste was emplaced in the Morsleben Repository (ERAM), a former salt mine, until 1998. Now the German Federal Office for Radiation Protection (Bundesamt fuer Strahlenschutz - BfS) has applied for the decommissioning of the plant. The ERAM's own radioactive waste requires clearance as far as it may not remain in the repository. The German Mining Law also demands all non-mining typical waste to be removed from the mine when being decommissioned and the Waste Avoidance, Recovery and Disposal Act demands waste to remain within the economy cycle if this is economically justifiable. Therefore new clearance measuring devices have to be applied using gamma and beta radiation to determine the contamination of objects and substances regarding the special nuclide spectra in the ERAM. Even if a very multifaceted radionuclide spectrum is to be expected due to the fact that the emplaced waste results from various applications such as nuclear engineering, medicine, research, and military, numerous investigations have confirmed that only a few radionuclides have to be considered. To facilitate this procedure the controlled area of the ERAM is to be classified according to different contamination categories. Assumptions about the radionuclide mixture are permanently controlled by routine measurements and the evaluation of possible contamination events. The considerations about the radionuclide mixture and the structure of the controlled area will be described in this presentation. Furthermore a new methodology to measure Sr-90 is discussed which uses the Cerenkov effect and the low level of background gamma radiation in the salt mine. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

600 C Logic Gates Using Silicon Carbide JFET's

Complex electronics and sensors are increasingly being relied on to enhance the capabilities and efficiency of modernjet aircraft. Some of these electronics and sensors monitor and control vital engine components and aerosurfaces that operate at high temperatures above 300 C. However, since today's silicon-based electronics technology cannot function at such high temperatures, these electronics must reside in environmentally controlled areas. This necessitates either the use of long wire runs between sheltered electronics and hot-area sensors and controls, or the fuel cooling of electronics and sensors located in high-temperature areas. Both of these low-temperature-electronics approaches suffer from serious drawbacks in terms of increased weight, decreased fuel efficiency, and reduction of aircraft reliability. A family of high-temperature electronics and sensors that could function in hot areas would enable substantial aircraft performance gains. Especially since, in the future, some turbine-engine electronics may need to function at temperatures as high as 600 C. This paper reports the fabrication and demonstration of the first semiconductor digital logic gates ever to function at 600 C. Key obstacles blocking the realization of useful 600 C turbine engine integrated sensor and control electronics are outlined.

Neudeck, Philip G.↗

Detailed SCALE Dose Rate Evaluations for a Consolidated Interim Spent Nuclear Fuel Storage Facility

This paper presents a confirmatory dose rate calculation for a proposed consolidated interim spent nuclear fuel (SNF) storage facility (CISF). The proposed CISF was modeled in detail using SCALE 6.2.1 to determine the radiation dose map of the surrounding areas of the facility and determine the location of the controlled area boundary based on 10 CFR 72.104 requirements. The spatial dose rate distribution was determined as the total dose rate contributions by each of the 467 storage casks comprising the CISF. A rectangular boundary outside of which no dose rate exceeds 25 mrem/yr has the dimensions of 1.25 km x 1.25 km. It denotes the smallest rectangle that could serve as the controlled area boundary. The results (dose map) show the unique capability of the SCALE code system for a high-resolution radiation dose simulation of a large SNF storage facility.

Radulescu, Georgeta↗

An Investigation of the Influence of Urban Areas on Rainfall Using the TRMM Satellite and a Cloud-Mesoscale Model

A recent paper by Shepherd and Pierce (in press at Journal of Applied Meteorology) used rainfall data from the Precipitation Radar on NASA's Tropical Rainfall Measuring Mission's (TRMM) satellite to identify warm season rainfall anomalies downwind of major urban areas. Data (PR) were employed to identify warm season rainfall (1998-2000) patterns around Atlanta, Montgomery, Nashville, San Antonio, Waco, and Dallas. Results reveal an average increase of approx. 28% in monthly rainfall rates within 30-60 kilometers downwind of the metropolis with a modest increase of 5.6% over the metropolis. Portions of the downwind area exhibit increases as high as 51%. The percentage changes are relative to an upwind control area. It was also found that maximum rainfall rates in the downwind impact area exceeded the mean value in the upwind control area by 48%-116%. The maximum value was generally found at an average distance of 39 km from the edge of the urban center or 64 km from the center of the city. Results are consistent with METROMEX studies of St. Louis almost two decades ago and with more recent studies near Atlanta. A convective-mesoscale model with extensive land-surface processes is currently being employed to (a) determine if an urban heat island (UHI) thermal perturbation can induce a dynamic response to affect rainfall processes and (b) quantify the impact of the following three factors on the evolution of rainfall: (1) urban surface roughness, (2) magnitude of the UHI temperature anomaly, and (3) physical size of the UHI temperature anomaly. The sensitivity experiments are achieved by inserting a slab of land with urban properties (e.g. roughness length, albedo, thermal character) within a rural surface environment and varying the appropriate lower boundary condition parameters. The study will discuss the feasibility of utilizing satellite-based rainfall estimates for examining rainfall modification by urban areas on global scales and over longer time periods. The talk also introduces very preliminary results from the modeling component of the study. Such research has implications for weather forecasting, urban planning, water resource management, and understanding human impact on the environment and climate.

Shepherd, J. Marshall↗

Rainfall Modification by Urban Areas: New Perspectives from TRMM

Data from the Tropical Rainfall Measuring Mission's (TRMM) Precipitation Radar (PR) were employed to identify warm season rainfall (1998-2000) patterns around Atlanta, Montgomery, Nashville, San Antonio, Waco, and Dallas. Results reveal an average increase of -28% in monthly rainfall rates within 30-60 kilometers downwind of the metropolis with a modest increase of 5.6% over the metropolis. Portions of the downwind area exhibit increases as high as 51%. The percentage changes are relative to an upwind control area. It was also found that maximum rainfall rates in the downwind impact area exceeded the mean value in the upwind control area by 48% - 116%. The maximum value was generally found at an average distance of 39 km from the edge of the urban center or 64 km from the center of the city. Results are consistent with METROMEX studies of St. Louis almost two decades ago and with more recent studies near Atlanta. Future work is extending the investigation to Phoenix, Arizona, an arid U.S. city, and several international cities like Mexico City, Johannesburg, and Brasilia. The study establishes the possibility of utilizing satellite-based rainfall estimates for examining rainfall modification by urban areas on global scales and over longer time periods. Such research has implications for weather forecasting, urban planning, water resource management, and understanding human impact on the environment and climate.

Shepherd, J. Marshall↗

On Rainfall Modification by Major Urban Areas: Observations from Space-borne Rain Radar on TRMM - Part 1

This study represents one of the first published attempts to identify rainfall modification by urban areas using satellite-based rainfall measurements. Data from the first space-based rain-radar, the Tropical Rainfall Measuring Mission's (TRMM) Precipitation Radar, are employed. Analysis of the data enables identification of rainfall patterns around Atlanta, Montgomery, Nashville, San Antonio, Waco, and Dallas during the warm season. Results reveal an average increase of -28% in monthly rainfall rates within 30-60 kilometers downwind of the metropolis with a modest increase of 5.6% over the metropolis. Portions of the downwind area exhibit increases as high as 51%. The percentage chances are relative to an upwind CONTROL area. It was also found that maximum rainfall rates in the downwind impact area can exceed the mean value in the upwind CONTROL area by 48%-116%. The maximum value was generally found at an average distance of 39 km from the edge of the urban center or 64 km from the center of the city. These results are consistent with METROMEX studies of St. Louis almost two decades ago and more recent studies near Atlanta. Future work will investi(yate hypothesized factors causing rainfall modification by urban areas. Additional work is also needed to provide more robust validation of space-based rain estimates near major urban areas. Such research has implications for urban planning, water resource management, and understanding human impact on the environment.

Shepherd, J. Marshall↗

An expert system for air traffic control system

The objective was to design a control logic which automates all or part of the guidance function for air traffic control systems. Particular interest was focused on automation of the terminal area control system. A preliminary study was done on the development of an expert system. The system may be used to assist controllers by providing them with feasible options in guiding each aircraft in the control area to its desired destination.

Sensui, Takashi↗

A Reversed Impedance-Based Stability Criterion for IBR Grids

The existing impedance-based stability criterion is effective for analyzing local control interactions; however, it is difficult to scale the existing criterion to analyze wide-area control interactions among numerous IBRs through a complex power system network. The scaled version of the existing criterion requires the impedance response of each IBR in the system as well as of the network looking from all the IBRs. It is quite challenging to obtain all these impedance responses because of the computational effort and the requirement of separately scanning the impedance of the network and the IBRs. We propose a reversed criterion for the impedance-based stability analysis to address these problems. In contrast to the existing criterion, the reversed criterion analyzes the stability of a power system when an IBR is disconnected from the system. The reversed criterion estimates the impact of an IBR on the frequency and damping of power system oscillation modes using the impedance scans of only the IBR and the grid at its terminal. It can be sequentially applied at different IBRs to evaluate their impact on the power system stability. In addition to scalability, the reversed criterion gives flexibility to focus only on a few selected IBRs, depending on their rating, the magnitude of oscillations observed at their terminals, and the vendor support available for implementing stabilizing control system updates. The reversed criterion is demonstrated on a 14-bus power system with 100% IBRs.

control interactions↗

SU-E-T-568: Neutron Dose Survey of a Compact Single Room Proton Machine

Purpose: To ensure acceptable radiation limits are maintained for those working at and near the machine during its operation, a comprehensive radiation survey was performed prior to the clinical release of Mevion S250 compact proton machine at Stephenson Oklahoma Cancer Center. Methods: The Mevion S250 proton therapy system consists of the following: a superconducting cyclotron to accelerate the proton particles, a passive double scattering system for beam shaping, and paired orthogonal x-ray imaging systems for patient setup and verification via a 6D robotic couch. All equipment is housed within a single vault of compact design. Two beam delivery applicators are available for patient treatment, offering field sizes of as great as 14 cm and 25 cm in diameter, respectively. Typical clinical dose rates are between 1 and 2 Gy/min with a fixed beam energy of 250 MeV. The large applicator (25 cm in diameter) was used in conjunction with a custom cut brass aperture to create a 20 cm x 20 cm field size at beam isocenter. A 30 cm − 30 cm − 35 cm high density plastic phantom was placed in the beam path to mimic the conditions creating patient scatter. Measurements integrated-ambient-neutron-dose-equivalence were made with a SWENDII detector. Gantry angles of 0, 90 and 180 degrees, with a maximum dose rate of 150 MU/min (for large applicator) and beam configuration of option 1 (range 25 cm and 20 cm modulation), were selected as testing conditions. At each point of interest, the highest reading was recorded at 30 cm from the barrier surface. Results: The highest neutron dose was estimated to be 0.085 mSv/year at the console area. Conclusion: All controlled areas are under 5 mSv/year and the uncontrolled areas are under 1 mSv/year. The radiation protection provided by the proton vault is of sufficient quality.

61 RADIATION PROTECTION AND DOSIMETRY↗