Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-F-T-650: The Comparison of Robotic Partial Breast Stereotactic Irradiation Using MLC Vs. Iris Cone

Purpose: To evaluate the dosimetric impact on treatment planning for partial breast stereotactic irradiation using Cyberknife with MLC versus Iris Cone. Methods: Ten patients whom underwent lumpectomy for DCIS or stage I invasive non-lobular epithelial breast cancer were included in this study. All patients were previously treated on the Cyberknife using Iris cone with the prescription dose of 37.5Gy in 5 fractions covering at least 95% of PTV on our phase I SBRT 5 fraction partial breast irradiation trial. Retrospectively, treatment planning was performed and compared using the new Cyberknife M6 MLC system for each patient. Using the same contours and critical organ constraints for both MLC and Iris cone plans, the dose on target and critical organs were analyzed accordingly. Results: Dose to critical organs such as ipsilateral lung, contralateral lung, heart, skin, ipsilateral breast, and rib were analyzed, as well as conformity index and high dose spillage of the target area. In 9 of 10 patients, the MLC plans had less total ipsilateral breast volume encompassing the 50% prescription isodose (mean:22.3±8.2% MLC vs. 31.6±8.0 Iris, p=0.00014) .The MLC plans mean estimated treatment delivery time was significantly less than the Iris plans (51±3.9min vs. 56.2±9min, p=0.03) Both MLC and Iris cone plans were able to meet all dose constraints and there was no statistical difference between those dose constraints. Conclusion: Both MLC and Iris Cone can deliver conformal dose to a partial breast target and satisfy the dose constraints of critical organs. The new Cyberknife with MLC can deliver a more conformal dose in the lower dose region and spare more ipsilateral breast tissue to the 50% prescription isodose. The treatment time for partial breast SBRT plans was also reduced using MLC. Project receives research support from Accuray Inc.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Deep learning assisted jet tomography for the study of Mach cones in QGP

Abstract Mach cones are expected to form in the expanding quark-gluon plasma (QGP) when energetic quarks and gluons traverse the hot medium at a velocity faster than the speed of sound in high-energy heavy-ion collisions. The shape of the Mach cone and the associated diffusion wake are sensitive to the initial jet production location and the propagation direction of the parton shower relative to the radial flow because of the distortion caused by the collective expansion of the QGP and the large density gradient. The shape of jet-induced Mach cones and their distortions in heavy-ion collisions provide a unique and direct probe of the dynamical evolution and the equation of state of QGP. However, it is difficult to identify the Mach cone and the diffusion wake in current experimental measurements of final hadron distributions because they are averaged over all possible initial jet production locations and parton-shower propagation directions. To overcome this difficulty, we develop a deep learning assisted jet tomography which uses the full information of the final hadrons from jets to localize the initial jet production positions. This method can help to constrain the initial regions of jet production in heavy-ion collisions and enable a differential study of Mach-cones with different path lengths and orientations relative to the radial flow of the QGP in heavy-ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonlinear dynamics of resonant interactions between wave packets and particle distributions with loss-cone-like structures

The paper studies the nonlinear mechanisms at work in magnetized plasmas when wave packets interact resonantly with particle distributions presenting loss-cone-like structures. Lower hybrid waves are considered in view of the great importance, in space and laboratory plasmas, of waves with frequencies below the electron cyclotron frequency. Owing to a three-dimensional Hamiltonian model and a numerical symplectic code, the authors study the nonlinear stage of the loss-cone instability for various particle distributions and wave spectra involving symmetric and asymmetric features. In particular, the wave-particle interaction process of dynamical resonance merging, which results from an instability of the trapped particles' motion and leads to complex stochastic phenomena, is discussed. Whereas interactions at normal cyclotron resonances are mostly considered, the role of the Landau and the anomalous cyclotron resonances is also studied to explain thoroughly the nonlinear wave-particle dynamics as well as the competition between loss-cone, fan, and beam instabilities. The relaxed particle distributions and the saturated wave spectra are analyzed. The time necessary for filling the loss-cone structures is determined as a function of the characteristics of the particle distributions. Whereas most of the previous works analyzed the asymptotic stage of the system's evolution in the frame of the well-known quasilinear theory, the paper considers the case when the energy carried by the wave packet is sufficiently large so that the description of the physical processes at work cannot be limited to the frame of weak turbulence theories.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-dissipative electromagnetic media with two Lorentz null cones

We study Maxwell's equations on a 4-manifold where the electromagnetic medium is modeled by an antisymmetric (2/2 )-tensor with 21 real coefficients. In this setting the Fresnel surface is a fourth-order polynomial surface that describes the dynamical response of the medium in the geometric optics limit. For example, in an isotropic medium the Fresnel surface is a Lorentz null cone. The contribution of this paper is the pointwise description of all electromagnetic medium tensors {kappa} with real coefficients that satisfy the following three conditions: (i)medium {kappa} is invertible, (ii)medium {kappa} is skewon-free, or non-dissipative, (iii)the Fresnel surface of {kappa} is the union of two distinct Lorentz null cones. We show that there are only three classes of media with these properties and give explicit expressions in local coordinates for each class. - Highlights: Black-Right-Pointing-Pointer We find two new electromagnetic media classes for which the Fresnel surface decomposes into two light cones. Black-Right-Pointing-Pointer In a suitable setting we classify all electromagnetic media where this is the case. Black-Right-Pointing-Pointer We find an electromagnetic medium tensor with three different signal speeds in one direction. Black-Right-Pointing-Pointer The work is related to [5], which classifies all media with one light cone (in a suitable setting).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics on the cone: Closed orbits and superintegrability

The generalization of Bertrand’s theorem to the case of the motion of point particle on the surface of a cone is presented. The superintegrability of such models is discussed. The additional integrals of motion are analysed for the case of Kepler and harmonic oscillator potentials. -- Highlights: •Bertrand’s theorem is generalized to the case of the motion on a cone. •The superintegrability of the dynamics on a cone is discussed. •The W-algebra of integrals of motion for Kepler and harmonic oscillator problems on a cone is derived.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dose Calculation on KV Cone Beam CT Images: An Investigation of the Hu-Density Conversion Stability and Dose Accuracy Using the Site-Specific Calibration

Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulate sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy{sup TM} system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to {approx}2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.

61 RADIATION PROTECTION AND DOSIMETRY↗

Classical Yang-Mills Mechanics: Instant vs. Light-cone Form

Two different forms of relativistic dynamics, the instant and the light-cone form, for the pure SU(2) Yang-Mills field theory in 4-dimensional Minkowski space are examined under the supposition that the gauge fields depend on the time evolution parameter only. The obtained under that restriction of gauge potential space homogeneity mechanical matrix model, sometimes called Yang-Mills classical mechanics, is systematically studied in its instant and light-cone form of dynamics using the Dirac's generalized Hamiltonian approach. In the both cases the constraint content of the obtained mechanical systems is found. In contrast to its well-known instant-time counterpart the light-cone version of SU(2) Yang-Mills classical mechanics has in addition to the constraints generating the SU(2) gauge transformations the new first and second class constraints also. On account of all of these constraints a complete reduction in number of the degrees of freedom is performed. In the instant form of dynamics it is shown that after elimination of the gauge degrees of freedom from the classical SU(2) Yang-Mills mechanics the resulting unconstrained system represents the ID{sub 3} Euler-Calogero-Moser model with a certain external fourth-order potential, whereas in the light-cone form it is argued that the classical evolution of the unconstrained degrees of freedom is equivalent to a free one-dimensional particle dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laboratory studies of the dynamic of resonance cones formation in magnetized plasmas

The paper is devoted to experimental studies of formation of resonance cones in magnetized plasmas by pulsed RF source in the lower-hybrid (whistler) and the upper-hybrid frequency ranges. It is shown that in both frequency ranges, resonance cones exhibit similar dynamics after switching-on the RF source: at first, wide maxima of radiation are formed in non-resonance directions, which then become narrower, with their direction approaching the resonance one. While the resonance cones are being formed, one observes a fine structure in the form of secondary radiation maxima. It is shown that the characteristic formation time of stationary resonance cones is determined by the minimal value of the group velocity of the quasi-electrostatic waves excited by the antenna. In the low-temperature plasma, this value is limited in the lower-hybrid frequency range by the spatial spectrum of the emitting antenna and in the upper-hybrid range, by the effects of spatial plasma dispersion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced proton acceleration by intense laser interaction with an inverse cone target

The generation and control of high-quality proton bunches using focused intense laser pulse on an inverse cone target is investigated with a set of particle-in-cell simulations. The inverse cone is a high atomic number conical frustum with a thin solid top and open base, where the laser impinges onto the top surface directly, not down the open end of the cone. Results are compared with a simple planar target, where the proton angular distribution is very broad because of transverse divergence of the electromagnetic fields behind the target. For a conical target, hot electrons along the cone wall surface induce a transverse focusing sheath field. This field can effectively suppress the spatial spreading of the protons, resulting in a high-quality small-emittance, low-divergence proton beam. A slightly lower proton beam peak energy than that of a conventional planar target was also found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ACCRETION OF SUPERSONIC WINDS ONTO BLACK HOLES IN 3D: STABILITY OF THE SHOCK CONE

Using numerical simulations we present the accretion of supersonic winds onto a rotating black hole in three dimensions. We study five representative directions of the wind with respect to the axis of rotation of the black hole and focus on the evolution and stability of the high-density shock cone that is formed during the process. We explore both the regime in which the shock cone is expected to be stable in order to confirm previous results obtained with two-dimensional simulations, and the regime in which the shock cone is expected to show a flip–flop (FF) type of instability. The methods used to attempt a triggering of the instability were (i) the accumulation of numerical errors and (ii) the explicit application of a perturbation on the velocity field after the shock cone was formed. The result is negative, that is, we did not find the FF instability within the parameter space we explored, including cases that are expected to be unstable.

79 ASTRONOMY AND ASTROPHYSICS↗

Terahertz surface plasmon polaritons on a conductive right circular cone: Analytical description and experimental verification

We report on an analytical solution of Maxwell's equations for the propagation of surface plasmon polaritons on a right circular cone. The problem was solved for THz frequencies in real metals and was therefore derived using the Leontovich approximation, which is valid for media with small surface impedances. The solution also accounts for both surface plasmon polaritons that are axisymmetric and those that have an angular structure in a plane normal to the cone's axis. This was an important consideration since it is crucial for describing surface phenomena such as surface-enhanced absorption, fluorescence, and Raman scattering. Our findings predict a total reflection of surface plasmon polaritons at the cone's apex, which was experimentally verified by an absence of light emitted from a heated cone's tip into the far-field region.

74 ATOMIC AND MOLECULAR PHYSICS↗

Form factors of B{sub u,d,s} decays into p-wave axial-vector mesons in the light-cone sum rule approach

We calculate the vector and axial-vector form factors of B{sub u,d,s} decays into P-wave axial-vector mesons in the light-cone sum rule approach. For the sum rule results, we have included corrections of order m{sub A}/m{sub b}, where m{sub A} is the mass of the axial-vector meson A. The results are relevant to the light-cone distribution amplitudes of the axial-vector mesons. It is important to note that, owing to the G parity, the chiral-even two-parton light-cone distribution amplitudes of the {sup 3}P{sub 1} ({sup 1}P{sub 1}) mesons are symmetric (antisymmetric) under the exchange of quark and antiquark momentum fractions in the SU(3) limit. For chiral-odd light-cone distribution amplitudes, it is the other way around. The predictions for decay rates of B{sub u,d,s}{yields}Ae{nu}{sub e} are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Instanton effects on the twist-three light-cone distribution amplitudes of pion and light scalar mesons above 1 GeV

By use of a single-instanton approximation the twist-three light-cone distribution amplitudes of the pion as well as the p-wave mesons, i.e., f{sub 0}(1370), K{sub 0}*(1430), and a{sub 0}(1450), are investigated within the framework of QCD moment sum rules with the inclusion of instanton effects based on the valence quark model. The results show that there is much change on light-cone distribution amplitudes due to the isospin- and chirality-dependent instanton contribution compared with the instanton-free ones. We find that the instanton-involved twist-three light-cone distribution amplitudes are non-positive-definite within some range of the momentum fraction and that there are rapid changes at two ends of the momentum fraction. To guarantee the convergence of moments using the method in this work, a low instanton density should be adopted; for instance, n{sub c}=(1/2) fm{sup -4}. Possible ingredients which might have an impact on the results are briefly discussed. These light-cone distribution amplitudes may be helpful to analyze exclusive heavy-flavored processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bright and durable field-emission source derived from frozen refractory-metal Taylor cones

A novel method for creating conical field-emission structures possessing unusual and desirable physical characteristics is described. This process is accomplished by solidification of electrostatically formed high-temperature Taylor cones created on the ends of laser melted refractory-metal wires. Extremely rapid freezing ensures that the resultant solid structures preserve the shape and surface smoothness of the flawless liquid Taylor-cones to a very high degree. The method also enables in situ and rapid restoration of the frozen cones to their initial pristine state after undergoing physical degradation during use. This permits maximum current to be delivered without excessive concern for any associated reduction in field-emitter lifetime resulting from operation near or even above the damage threshold. In addition to the production of field emitters using polycrystalline wires as a substrate, the feasibility of producing monocrystalline frozen Taylor-cones having reproducible crystal orientation by growth on single-crystal wires was demonstrated. Finally, the development of the basic field-emission technology, progress to incorporate it into a pulsed electron gun employing laser-assisted field emission for ultrafast experiments, and some additional advances and opportunities are discussed.

36 MATERIALS SCIENCE↗

TH-EF-207A-04: A Dynamic Contrast Enhanced Cone Beam CT Technique for Evaluation of Renal Functions

Purpose: To develop a simple but robust method for the early detection and evaluation of renal functions using dynamic contrast enhanced cone beam CT technique. Methods: Experiments were performed on an integrated imaging and radiation research platform developed by our lab. Animals (n=3) were anesthetized with 20uL Ketamine/Xylazine cocktail, and then received 200uL injection of iodinated contrast agent Iopamidol via tail vein. Cone beam CT was acquired following contrast injection once per minute and up to 25 minutes. The cone beam CT was reconstructed with a dimension of 300×300×800 voxels of 130×130×130um voxel resolution. The middle kidney slices in the transvers and coronal planes were selected for image analysis. A double exponential function was used to fit the contrast enhanced signal intensity versus the time after contrast injection. Both pixel-based and region of interest (ROI)-based curve fitting were performed. Four parameters obtained from the curve fitting, namely the amplitude and flow constant for both contrast wash in and wash out phases, were investigated for further analysis. Results: Robust curve fitting was demonstrated for both pixel based (with R{sup 2}>0.8 for >85% pixels within the kidney contour) and ROI based (R{sup 2}>0.9 for all regions) analysis. Three different functional regions: renal pelvis, medulla and cortex, were clearly differentiated in the functional parameter map in the pixel based analysis. ROI based analysis showed the half-life T1/2 for contrast wash in and wash out phases were 0.98±0.15 and 17.04±7.16, 0.63±0.07 and 17.88±4.51, and 1.48±0.40 and 10.79±3.88 minutes for the renal pelvis, medulla and cortex, respectively. Conclusion: A robust method based on dynamic contrast enhanced cone beam CT and double exponential curve fitting has been developed to analyze the renal functions for different functional regions. Future study will be performed to investigate the sensitivity of this technique in the detection of radiation induced kidney dysfunction.

60 APPLIED LIFE SCIENCES↗

Energy momentum tensor on and off the light cone: exposition with scalar Yukawa theory

Abstract We compute the gravitational form factorsA i ,D i and$$ {\overline{c}}_i $$ c ¯ i of the scalar Yukawa theory using both the light-cone and covariant perturbation theory at the one-loop level. The light-cone formalism provides a potential approach to access these form factors beyond the perturbative regime. However, unlike the covariant formulation, the Poincaré symmetry on the light cone is not manifest. In this work, we use perturbation theory as a benchmark to extract the gravitational form factors from the light-front energy-momentum tensor. By comparing results on and off the light cone, we identifyT ++ ,T +a ,T +− ,T 12 as the “good currents” that are properly renormalized and can be used to extract the gravitational form factors.

Physics↗

The holographic entropy cone from marginal independence

The holographic entropy cone characterizes the relations between entanglement entropies for a spatial partitioning of the boundary spacetime of a holographic CFT in any state describing a classical bulk geometry. We argue that the holographic entropy cone, for an arbitrary number of parties, can be reconstructed from more fundamental data determined solely by subadditivity of quantum entropy. We formulate certain conjectures about graph models of holographic entanglement, for which we provide strong evidence, and rigorously prove that they all imply that such a reconstruction is possible. Our conjectures (except only for the weakest) further imply that the necessary data is remarkably simple. In essence, all one needs to know to reconstruct the holographic entropy cone, is a certain subset of the extreme rays of this simpler “subadditivity cone”, namely those which can be realized in holography. This recasting of the bewildering entanglement structure of geometric states into primal building blocks paves the way to distilling the essence of holography for the emergence of a classical bulk spacetime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗