The circulating immunoglobulins negatively impact on the parasite clearance in the liver of Leishmania donovani-infected mice via dampening ROS activity

Highlights: • Mice with the absence of circulating immunoglobulins are resistant to Leishmania donovani infection. • The clearance of parasites in liver of these mice occurs from the early stage of infection. • This rapid clearance is independent of interferon gamma. • Reactive oxygen species pathway is involved in this rapid clearance. • Circulating immunoglobulins dampens reactive oxygen species pathway in the liver of Leishmania donovani-infected mice. Visceral leishmaniasis, the most severe form of leishmaniasis, is caused by Leishmania donovani and L. infantum. Immunity to Leishmania infection has been shown to depend on the development of Th1 cells; however, the roles of B cells and antibodies during infection remain unclear. In the present study, we showed that AID and μs double-deficient mice (DKO), which have B cells but not circulating immunoglobulins (cIgs), became resistant to L. donovani infection, whereas μs or AID single-deficient mice did not. This resistance in DKO mice occurred in the liver from an early stage of the infection. The depletion of IFN-γ did not affect the rapid reduction of parasite burden, whereas NADPH oxidases was up-regulated in the livers of infected DKO mice. The inhibition of the reactive oxygen species pathway in vivo by apocynin, a NADPH oxidase inhibitor, resulted in a significant increase in the parasite burden in DKO mice. These results indicate that a circulating Ig deficiency induces a protective response against L. donovani infection by elevating IFN-γ-independent NADPH oxidase activity, and also that cIgs play a regulatory role in controlling L. donovani infection in mice.

60 APPLIED LIFE SCIENCES↗

Dual Exosite-binding Inhibitors of Insulin-degrading Enzyme Challenge Its Role as the Primary Mediator of Insulin Clearance in Vivo

Insulin-degrading enzyme (IDE, insulysin) is the best characterized catabolic enzyme implicated in proteolysis of insulin. Recently, a peptide inhibitor of IDE has been shown to affect levels of insulin, amylin, and glucagon in vivo. However, IDE –/– mice display variable phenotypes relating to fasting plasma insulin levels, glucose tolerance, and insulin sensitivity depending on the cohort and age of animals. As such, here, we interrogated the importance of IDE-mediated catabolism on insulin clearance in vivo. Using a structure-based design, we linked two newly identified ligands binding at unique IDE exosites together to construct a potent series of novel inhibitors. These compounds do not interact with the catalytic zinc of the protease. Because one of these inhibitors (NTE-1) was determined to have pharmacokinetic properties sufficient to sustain plasma levels >50 times its IDE IC 50 value, studies in rodents were conducted. In oral glucose tolerance tests with diet-induced obese mice, NTE-1 treatment improved the glucose excursion. Yet in insulin tolerance tests and euglycemic clamp experiments, NTE-1 did not enhance insulin action or increase plasma insulin levels. Importantly, IDE inhibition with NTE-1 did result in elevated plasma amylin levels, suggesting the in vivo role of IDE action on amylin may be more significant than an effect on insulin. Furthermore, using the inhibitors described in this report, we demonstrate that in HEK cells IDE has little impact on insulin clearance. In total, evidence from our studies supports a minimal role for IDE in insulin metabolism in vivo and suggests IDE may be more important in helping regulate amylin clearance.

59 BASIC BIOLOGICAL SCIENCES↗

Current Estimates for HIV-1 Production Imply Rapid Viral Clearance in Lymphoid Tissues

It has recently been estimated that a single HIV-1 infected cell produces between 103 and more than 104 viral particles over its life span. Since body-wide estimates of the ratio of free virus to productively infected cells are smaller than 103 and much smaller than 104, individual virions must be cleared rapidly. This seems difficult to reconcile with the fact that most of the total body virus is trapped on follicular dendritic cells where it can survive for many months. It has also been difficult to reconcile the vast difference in the rates at which the virus is cleared from the blood in rhesus macaques and in chronically infected patients. Here we attempt to reconcile these seemingly contradictory observations by considering the virion clearance rate in various organs and the virion exchange rates between them. The main results are that the per capita clearance rate of free virus in lymphoid tissue should be fast, the virion exchange rate between lymphoid tissue and the blood should be slow, and the comparatively slow previous estimates for the virion clearance rate from the blood correspond to the rate of virion efflux from the blood to other organs where the virus is ultimately cleared.

59 BASIC BIOLOGICAL SCIENCES↗

Independent Verification Plan for Clearance of Real Property of the Operation Roller Coaster Sites

The U.S. Department of Energy (DOE) is pursuing release of the Operation Roller Coaster sites under DOE O 458.1, “Radiation Protection of the Public and the Environment.” The requirements for clearance and release of property under DOE O 458.1 are implemented when DOE intends to facilitate transfer of responsibility or control of real property from DOE. DOE O 458.1 prescribes that all radiological monitoring or surveys performed in support of clearance of property must use methods such as the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) method or other methods approved by DOE. DOE O 458.1 requires an Independent Verification for the clearance of real property. This Independent Verification Plan outlines the process for validating the method and implementation of the MARRSIM process for release of the Operation Roller Coaster sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Independent Verification Report for Clearance Operation Roller Coaster Sites

The U.S. Department of Energy (DOE) is pursuing clearance of the Operation Roller Coaster sites under DOE O 458.1, Radiation Protection of the Public and the Environment. The clearance of property requirements in DOE O 458.1 must be implemented when DOE intends to facilitate future transfers of responsibility/control of real property. DOE O 458.1 prescribes that all radiological monitoring or surveys performed in support of clearance of property must use methods such as the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) or other methods approved by DOE. MARSSIM recommends using a series of surveys for collecting information required to demonstrate compliance. These surveys form the Radiation Survey and Site Investigation (RSSI) Process.

99 GENERAL AND MISCELLANEOUS↗

Modeling hepatitis C virus kinetics during liver transplantation highlights the role of the liver in virus clearance

While the liver, specifically hepatocytes, are widely accepted as the main source of hepatitis C virus (HCV) production, the role of the liver/hepatocytes in clearance of circulating HCV remains unknown. Frequent HCV kinetic data were recorded and mathematically modeled from five liver transplant patients throughout the anhepatic (absence of liver) phase and for 4 hr post-reperfusion. During the anhepatic phase, HCV remained at pre-anhepatic levels (n = 3) or declined (n = 2) with t 1/2 ~1 hr. Immediately post-reperfusion, virus declined in a biphasic manner in four patients consisting of a rapid decline (t 1/2 = 5 min) followed by a slower decline (t 1/2 = 67 min). Consistent with the majority of patients in the anhepatic phase, when we monitored HCV clearance at 37°C from culture medium in the absence/presence of chronically infected hepatoma cells that were inhibited from secreting HCV, the HCV t 1/2 in cell culture was longer in the absence of chronically HCV-infected cells. The results suggest that the liver plays a major role in the clearance of circulating HCV and that hepatocytes may be involved.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced optical blade tip clearance measurement system

An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.

Ford, M. J.↗

Effect of rotor tip clearance and configuration on overall performance of a 12.77-centimeter tip diameter axial-flow turbine

An extensive experimental investigation was made to determine the effect of varying the rotor tip clearance of a 12.77-cm-tip diameter, single-stage, axial-flow reaction turbine. In this investigation, the rotor tip clearance was obtained by use of a recess in the casing above the rotor blades and also by use of a reduced blade height. For the recessed casing configuration, the optimum rotor blade height was found to be the one where the rotor tip diameter was equal to the stator tip diameter. The tip clearance loss associated with this optimum recessed casing configuration was less than that for the reduced blade height configuration.

Haas, J. E.↗

Laser-optical blade tip clearance measurement system

A laser-optical measurement system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in rotating component rigs and complete engines. The system is applicable to fan, compressor and turbine blade tip clearance measurements. The engine mounted probe is particularly suitable for operation in the extreme turbine environment. The measurement system consists of an optical subsystem, an electronic subsystem and a computing and graphic terminal. Bench tests and environmental tests were conducted to confirm operation at temperatures, pressures, and vibration levels typically encountered in an operating gas turbine engine.

Barranger, J. P.↗

Expanded study of feasibility of measuring in-flight 747/JT9D loads, performance, clearance, and thermal data

The JT9D jet engine exhibits a TSFC loss of about 1 percent in the initial 50 flight cycles of a new engine. These early losses are caused by seal-wear induced opening of running clearances in the engine gas path. The causes of this seal wear have been identified as flight induced loads which deflect the engine cases and rotors, causing the rotating blades to rub against the seal surfaces, producing permanent clearance changes. The real level of flight loads encountered during airplane acceptance testing and revenue service and the engine's response in the dynamic flight environment were investigated. The feasibility of direct measurement of these flight loads and their effects by concurrent measurement of 747/JT9D propulsion system aerodynamic and inertia loads and the critical engine clearance and performance changes during 747 flight and ground operations was evaluated. A number of technical options were examined in relation to the total estimated program cost to facilitate selection of the most cost effective option. It is concluded that a flight test program meeting the overall objective of determining the levels of aerodynamic and inertia load levels to which the engine is exposed during the initial flight acceptance test and normal flight maneuvers is feasible and desirable. A specific recommended flight test program, based on the evaluation of cost effectiveness, is defined.

Sallee, G. P.↗

Participation of the hypophyseal-adrenal cortex system in thrombin clearance during immobilization stress

Thrombin marked with I-131 resulted in a considerable increase of the thrombined clearance rate in healthy male rats during stress caused by an immobilization lasting 30 minutes, and in an increase of thrombin clearance occurred by a combination of immobilization and administration of adrenocorticotropin (ACTH). Contrary to ACTH, the thrombin clearance is not stimulated in healthy animals by hydrocortisone. The results of the examination are presented.

Kudryashov, B. A.↗

Simple geometric algorithms to aid in clearance management for robotic mechanisms

Global geometric shapes such as lines, planes, circles, spheres, cylinders, and the associated computational algorithms which provide relatively inexpensive estimates of minimum spatial clearance for safe operations were selected. The Space Shuttle, remote manipulator system, and the Power Extension Package are used as an example. Robotic mechanisms operate in quarters limited by external structures and the problem of clearance is often of considerable interest. Safe clearance management is simple and suited to real time calculation, whereas contact prediction requires more precision, sophistication, and computational overhead.

Copeland, E. L.↗

Investigation of the tip clearance flow inside and at the exit of a compressor rotor passage

The nature of the tip clearance flow in a moderately loaded compressor rotor is studied. The measurements were taken inside the clearance between the annulus-wall casing and the rotor blade tip. These measurements were obtained using a stationary two-sensor hot-wire probe in combination with an ensemble averaging technique. The flowfield was surveyed at various radial locations and at ten axial locations, four of which were inside the blade passage in the clearance region and the remaining six outside the passage. Variations of the mean flow properties in the tangential and the radial directions at various axial locations were derived from the data. Variation of the leakage velocity at different axial stations and the annulus-wall boundary layer profiles from passage-averaged mean velocities were also estimated.

Pandya, A.↗

Investigation of the tip clearance flow inside and at the exit of a compressor rotor passage. II - Turbulence properties

The flow in the tip clearance region of a compressor rotor is highly turbulent due to the strong interaction of the leakage flow with the annulus wall boundary layer. This paper deals with the turbulence properties of the flow in the tip clearance region of a moderately loaded compressor rotor. The experimental results reported in this paper were obtained using a two-sensor hot-wire probe in combination with an ensemble averaging technique. Blade-to-blade distribution of the axial and tangential turbulence intensities at various radial locations and ten axial locations (four inside the blade passage and the remaining six outside the passage) were derived from this data. Isointensity contours in the clearance region at various radial locations were also obtained from the experimental data. A region of very high turbulence intensities was indicated at the half-chord location from these results. The turbulence intensity profiles also indicated that the leakage flow travels toward the midpassage before rolling up. The turbulence is almost isotropic beyond three-quarter chord downstream of the trailing edge.

Pandya, A.↗

Low-cost FM oscillator for capacitance type of blade tip clearance measurement system

The frequency-modulated (FM) oscillator described is part of a blade tip clearance measurement system that meets the needs of a wide class of fans, compressors, and turbines. As a result of advancements in the technology of ultra-high-frequency operational amplifiers, the FM oscillator requires only a single low-cost integrated circuit. Its carrier frequency is 42.8 MHz when it is used with an integrated probe and connecting cable assembly consisting of a 0.81 cm diameter engine-mounted capacitance probe and a 61 cm long hermetically sealed coaxial cable. A complete circuit analysis is given, including amplifier negative resistance characteristics. An error analysis of environmentally induced effects is also derived, and an error-correcting technique is proposed. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a rotor blade thickness of 1.2 mm. High-temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum permissible seal temperature. The major source of error is the residual FM oscillator noise, which produces a clearance error of + or - 10 microns at a clearance of 0.5 mm. The oscillator electronics accommodates the high rotor speeds associated with small engines, the signals from which may have frequency components as high as 1 MHz.

Barranger, John P.↗

The effects of pin elasticity, clearance, and friction on the stresses in a pin-loaded orthotropic plate

The effects of pin elasticity, clearance, and friction on the stresses in a pin loaded orthotropic plate are studied. The effects are studied by posing the problem as a planar contact elasticity problem, the pin and the plate being two elastic bodies which interact through contact. Coulomb friction is assumed, the pin loads the plate in one of its principal material directions, and the plate is infinite in extent. A collocation scheme and interaction, in conjunction with a complex variable series solution, are used to obtain numerical results. The contact region between the plate and pin is unknown and must be solved for as part of the solution. The same is true of the region of friction induced no slip. Two pin stiffnesses, two clearance levels, two friction levels and two laminates, a (0/+ or - 45/90)s and a (02/+ or - 45)s, are studied. The effects of pin elasticity, clearance, and friction on the load capacity of the plate are assessed by comparing the load capacity of the plate with the capacity when the pin is rigid, perfectly fitting, and frictionless.

Hyer, M. W.↗

Recent advances in capacitance type of blade tip clearance measurements

Two recent electronic advances at NASA-Lewis that meet the blade tip clearance needs of a wide class of fans, compressors, and turbines are described. The first is a frequency modulated (FM) oscillator that requires only a single low cost ultrahigh frequency operational amplifier. Its carrier frequency is 42.8 MHz when used with a 61 cm long hermetically sealed coaxial cable. The oscillator can be calibrated in the static mode and has a negative peak frequency deviation of 400 kHz for a typical rotor blade. High temperature performance tests of the probe and 13 cm of the adjacent cable show good accuracy up to 600 C, the maximum which produces a clearance error of + or - 10 microns at a clearance of 500 microns. In the second advance, a guarded probe configuration allows a longer cable capacitance. The capacitance of the probe is part of a small time constant feedback in a high speed operational amplifier. The solution of the governing differential equation is applied to a ramp type of input. The results show an amplifier output that contains a term which is proportional to the derivative of the feedback capacitance. The capacitance is obtained by subtracting a balancing reference channel followed by an integration stage.

Barranger, John P.↗

Stress analysis method for clearance-fit joints with bearing-bypass loads

Within a multi-fastener joint, fastener holes may be subjected to the combined effects of bearing loads and loads that bypass the hole to be reacted elsewhere in the joint. The analysis of a joint subjected to search combined bearing and bypass loads is complicated by the usual clearance between the hole and the fastener. A simple analysis method for such clearance-fit joints subjected to bearing-bypass loading has been developed in the present study. It uses an inverse formulation with a linear elastic finite-element analysis. Conditions along the bolt-hole contact arc are specified by displacement constraint equations. The present method is simple to apply and can be implemented with most general purpose finite-element programs since it does not use complicated iterative-incremental procedures. The method was used to study the effects of bearing-bypass loading on bolt-hole contact angles and local stresses. In this study, a rigid, frictionless bolt was used with a plate having the properties of a quasi-isotropic graphite/epoxy laminate. Results showed that the contact angle as well as the peak stresses around the hole and their locations were strongly influenced by the ratio of bearing and bypass loads. For single contact, tension and compression bearing-bypass loading had opposite effects on the contact angle. For some compressive bearing-bypass loads, the hole tended to close on the fastener leading to dual contact. It was shown that dual contact reduces the stress concentration at the fastener and would, therefore, increase joint strength in compression. The results illustrate the general importance of accounting for bolt-hole clearance and contact to accurately compute local bolt-hole stresses for combined bearings and bypass loading.