Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLEANING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Review of Clean Electricity Policies—From Countries to Utilities

Due to the heavy stress on environmental deterioration and the excessive consumption of fossil resources, the transition of global energy from fossil fuel energy to clean energy has significantly accelerated in recent years. The power industry and policymakers in almost all countries are focusing on clean energy development. Thanks to progressive clean energy policies, significant progress in clean energy integration and greenhouse gas reduction has been achieved around the world. However, due to the differences in economic structures, clean energy distributions, and development models, clean energy policy scope, focus, and coverage vary between different countries, states, and utilities. This paper aims at providing a policy review for readers to easily obtain clean energy policy information on various clean energies in the U.S. and some other countries. Firstly, this paper reviews and compares some countries’ clean energy policies on electricity. Then, taking the U.S. as an example, this paper introduces the clean energy policies of some representative states and utilities in the U.S in perspectives of renewable energies, electric vehicles, and energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Cleaning Methods for Dust Mitigation of Lunar Docking and Hatch Seals

Low-leakage seals are an enabling technology for future lunar surface systems, and they must be kept clean to ensure that crews have sufficient breathable air for extended lunar surface missions. Previous testing on representative state-of-the-art seals showed that while seals can tolerate some level of lunar simulant dust contamination, dust can degrade seal performance to a point at which seal leak rates exceed maximum allowable values. The ability to clean simulant from seals had not been thoroughly studied, and the effectiveness and potential complications of using different cleaning methods for lunar seals were not well understood. To address this knowledge gap, researchers at the NASA Glenn Research Center executed a multiphase study to better understand and mitigate seal dust-exposure risks. The focus of this report is on the second phase of that study, in which tests were conducted to evaluate the viability of seal cleaning methods for use in the lunar environment. Multiple methods for cleaning seals contaminated with lunar simulant were assessed for cleaning effectiveness and viability for use in the lunar environment. Leak tests were performed on seals after they were cleaned to determine whether leak rates could be brought back to acceptable levels, and cleaned seals were examined to determine whether their surfaces had been damaged by the cleaning processes. This phase of the study also investigated changes in the seals’ adhesion forces as a result of contamination and cleaning.

Dust Mitigation↗

Glass-particle adhesion-force-distribution on clean (laboratory) and contaminated (outdoor) surfaces

This article explores whether laboratory-clean samples are representative of real outdoor surfaces – often covered in dust and other contaminants – with respect to adhesion properties, which ultimately affect particle resuspension. In this study, Atomic Force Microscopy (AFM) was used to measure the adhesion force between a clean, smooth glass particle (5 µm in diameter) and two glass slides, one prepared according to common laboratory practices (hereafter, clean glass) and a second one left outdoors for six weeks (hereafter, contaminated glass). It was found that the adhesion force distribution was bimodal for the clean glass while it showed three peaks for the contaminated glass. For both surfaces, the adhesion force showed a peak at very low adhesion values (< 100 nN) representing 1.2% of the measurements for the clean glass and 58% for the contaminated glass. This low-adhesion peak is important because it represents the particles that would be resuspended first even in light winds. The low adhesion-force measurements were associated with the presence of contaminants on the surface. Another notable difference between the adhesion force distributions was a long tail at high adhesion forces for clean glass (up to ~1900 nN) and the absence of the tail for the contaminated glass, which had a maximum adhesion force of 950 nN. The mean adhesion force on the contaminated glass was also lower than on the clean glass (206 ± 240 nN vs. 516 ± 354 nN). These observations indicate that the adhesion force distribution between a 5-µm smooth and clean glass sphere and the outdoor contaminated glass surface is quite different from that of the clean glass surface. Hence, one should be cautious when using adhesion force measurements from clean surfaces to estimate particle resuspension from outdoor surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

U.S. Department of Energy clean cities five-year strategic plan.

Clean Cities is a government-industry partnership sponsored by the U.S. Department of Energy's (DOE) Vehicle Technologies Program, which is part of the Office of Energy Efficiency and Renewable Energy. Working with its network of about 100 local coalitions and more than 6,500 stakeholders across the country, Clean Cities delivers on its mission to reduce petroleum consumption in on-road transportation. In its work to reduce petroleum use, Clean Cities focuses on a portfolio of technologies that includes electric drive, propane, natural gas, renewable natural gas/biomethane, ethanol/E85, biodiesel/B20 and higher-level blends, fuel economy, and idle reduction. Over the past 17 years, Clean Cities coalitions have displaced more than 2.4 billion gallons of petroleum; they are on track to displace 2.5 billion gallons of gasoline per year by 2020. This Clean Cities Strategic Plan lays out an aggressive five-year agenda to help DOE Clean Cities and its network of coalitions and stakeholders accelerate the deployment of alternative fuel and advanced technology vehicles, while also expanding the supporting infrastructure to reduce petroleum use. Today, Clean Cities has a far larger opportunity to make an impact than at any time in its history because of its unprecedented $300 million allocation for community-based deployment projects from the American Recovery and Reinvestment Act (ARRA) (see box below). Moreover, the Clean Cities annual budget has risen to $25 million for FY2010 and $35 million has been requested for FY2011. Designed as a living document, this strategic plan is grounded in the understanding that priorities will change annually as evolving technical, political, economic, business, and social considerations are woven into project decisions and funding allocations. The plan does not intend to lock Clean Cities into pathways that cannot change. Instead, with technology deployment at its core, the plan serves as a guide for decision-making at both the national and local levels of Clean Cities over the next five years. The plan recognizes the need for flexibility and sets out a strategic direction that will build on the progress of current technologies and new opportunities presented in emerging fuels and technologies, such as hydrogen and fuel cells, as well as new niche markets such as off-road applications that build additional throughput at existing alternative fuel stations.

02 PETROLEUM↗

Laser Ablation Cleaning of Self-Reacting Friction Stir Weld Seam Surfaces: A Preliminary Evaluation

Anodized aluminum panels were cleaned by three lasers at three separate sites with a view to determining whether more economical laser cleaning might supplant current manual cleaning methods for preparation of surfaces to be welded by the self-reacting friction stir process. Uncleaned panels yielded welds exhibiting residual oxide defect (ROD) and failing at very low stresses along the trace of the weld seam. Manually cleaned panels yielded welds without ROD; these welds failed at nominal stress levels along an angled fracture surface not following the weld seam trace. Laser cleaned panels yielded welds failing at intermediate stress levels. The inadequacy of the laser cleaning processes leaves questions: Was the anodized aluminum test too stringent to represent actual cleaning requirements? Were the wrong laser cleaning techniques/parameters used for the study? Is the laser cleaning mechanism inadequate for effective preweld surface cleaning?

Nunes, A. C., Jr.↗

Chemical cleaning of porous stainless steel cross-flow filter elements for nuclear waste applications

The Waste Treatment and Immobilization Plant (WTP) currently under construction for treatment of High-Level Waste (HLW) at the Hanford Site will rely on cross-flow ultrafiltration to provide solids-liquid separation as a core part of the treatment process. To optimize process throughput, periodic chemical cleaning of the porous stainless steel filter elements has been incorporated into the design of the plant. It is currently specified that chemical cleaning with nitric acid will occur after significant irreversible membrane fouling is observed. Irreversible fouling is defined as fouling that cannot be removed by backpulsing the filter. PNNL has investigated chemical cleaning processes as part of integrated tests with HLW simulants and with actual Hanford tank wastes. To quantify the effectiveness of chemical cleaning, the residual membrane resistance after cleaning was compared against the initial membrane resistance for each test in a series of long-term fouling tests. The impact of the small amount of residual resistance in these tests could not be separated from other parameters and the historical benchmark of >1 GPM/ft2 for clean water flux was determined to be an adequate metric for chemical cleaning. Using the results from these tests, a process optimization strategy is presented suggesting that for the simulant material under test, the value of chemical cleaning may be suspect. The period of enhanced filtration may not be enough to offset the down time required for chemical cleaning, without respect to the other associated costs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated Facility For Cleaning Large Flex Hoses

Technicians no longer exposed to hazardous cleaning materials. Proposed computer-controlled facility cleans bellow-type expansion joints and large flex hoses. Major portions of automated cleaning facility contained in clean room. One piece of equipment in clean room tower in which hose or expansion joint to be cleaned hoisted by hydraulic machinery and hung vertically. Once hose or expansion joint hung in required position, technician initiates programmed cleaning procedure from console on computer monitoring system. Procedure includes degreasing, cleaning with detergents, rinsing, pickling, and passivating operations. After cleaning completed, technician removes hose or expansion joint from tower and wraps open ends to prevent recontamination of interior.

Landry, Louis E.↗

Precision Cleaning and Verification Processes Used at Marshall Space Flight Center for Critical Hardware Applications

Marshall Space Flight Center (MSFC) of the National Aeronautics and Space Administration performs many research and development programs that require hardware and assemblies to be cleaned to levels that are compatible with fuels and oxidizers (liquid oxygen, solid propellants, etc.). Also, MSFC is responsible for developing large telescope satellites which require a variety of optical systems to be cleaned. A precision cleaning shop is operated within MSFC by the Fabrication Services Division of the Materials & Processes Laboratory. Verification of cleanliness is performed for all precision cleaned articles in the Environmental and Analytical Chemistry Branch. Since the Montreal Protocol was instituted, MSFC had to find substitutes for many materials that have been in use for many years, including cleaning agents and organic solvents. As MSFC is a research center, there is a great variety of hardware that is processed in the Precision Cleaning Shop. This entails the use of many different chemicals and solvents, depending on the nature and configuration of the hardware and softgoods being cleaned. A review of the manufacturing cleaning and verification processes, cleaning materials and solvents used at MSFC and changes that resulted from the Montreal Protocol will be presented.

Caruso, Salvadore V.↗

Precision Cleaning and Verification Processes Used at Marshall Space Flight Center for Critical Hardware Applications

Marshall Space Flight Center (MSFC) of the National Aeronautics and Space Administration (NASA) performs many research and development programs that require hardware and assemblies to be cleaned to levels that are compatible with fuels and oxidizers (liquid oxygen, solid propellants, etc.). Also, the Center is responsible for developing large telescope satellites which requires a variety of optical systems to be cleaned. A precision cleaning shop is operated with-in MSFC by the Fabrication Services Division of the Materials & Processes Division. Verification of cleanliness is performed for all precision cleaned articles in the Analytical Chemistry Branch. Since the Montreal Protocol was instituted, MSFC had to find substitutes for many materials that has been in use for many years, including cleaning agents and organic solvents. As MSFC is a research Center, there is a great variety of hardware that is processed in the Precision Cleaning Shop. This entails the use of many different chemicals and solvents, depending on the nature and configuration of the hardware and softgoods being cleaned. A review of the manufacturing cleaning and verification processes, cleaning materials and solvents used at MSFC and changes that resulted from the Montreal Protocol will be presented.

Caruso, Salvadore V.↗

Clean Assembly of Genesis Collector Canister for Flight: Lessons for Planetary Sample Return

Measurement of solar composition in the Genesis collectors requires not only high sensitivity but very low blanks; thus, very strict collector contamination minimization was required beginning with mission planning and continuing through hardware design, fabrication, assembly and testing. Genesis started with clean collectors and kept them clean inside of a canister. The mounting hardware and container for the clean collectors were designed to be cleanable, with access to all surfaces for cleaning. Major structural components were made of aluminum and cleaned with megasonically energized ultrapure water (UPW). The UPW purity was >18 M resistivity. Although aluminum is relatively difficult to clean, the Genesis protocol achieved level 25 and level 50 cleanliness on large structural parts; however, the experience suggests that surface treatments may be helpful on future missions. All cleaning was performed in an ISO Class 4 (Class 10) cleanroom immediately adjacent to an ISO Class 4 assembly room; thus, no plastic packaging was required for transport. Persons assembling the canister were totally enclosed in cleanroom suits with face shield and HEPA filter exhaust from suit. Interior canister materials, including fasteners, were installed, untouched by gloves, using tweezers and other stainless steel tools. Sealants/lubricants were not exposed inside the canister, but vented to the exterior and applied in extremely small amounts using special tools. The canister was closed in ISO Class 4, not to be opened until on station at Earth-Sun L1. Throughout the cleaning and assembly, coupons of reference materials that were cleaned at the same time as the flight hardware were archived for future reference and blanks. Likewise reference collectors were archived. Post-mission analysis of collectors has made use of these archived reference materials.

Allton, J. H.↗

Clean Energy Innovation Ecosystems Discovery - Measuring Innovation Through Data Analytics (MIDAS)

As part of the Mission Innovation rollout at the Paris COP 21, 20 countries announced to double their R&D budgets over 5 years to accelerate lab-to-market clean energy innovations. These innovations must address technical urgency and navigate complex institutional, social and financial environments. To inform budget and program development, policymakers need to understand existing clean energy innovation ecosystems (IE) and their characteristics at the local, state, and regional levels within the US. Researchers at ORNL have implemented a ground-breaking application of natural language processing, link analysis, and other computational techniques to transform text and numerical data into metrics on clean energy innovation activity and geography. The 'Measuring Innovation through Data Analytics' (MIDAS) application uses data to determine where clean energy innovation ecosystems exist and the underlying scoring algorithm "ranks" the strength of the ecosystem for several clean energy technologies. The selection of the data sources is driven by the fact that a clean energy IE can be identified as an intersection of nascent clean technology efforts and financing mechanisms and related large companies located in a geographically concentrated area with an enabling environment to encourage commercialization and networking assets to facilitate communication. MIDAS is a machine-assisted methodology that provides the user with a replicable method to rapidly identify, quantify and characterize clean energy innovation ecosystems. This software application and the underlying datasets have the potential to address many important policy questions. The initial broad list of U.S. clean energy ecosystems, with geographic area, technology focus, and list and types of involved organizations can help describe regional tech activities and capabilities. Other potential applications include understanding the effect of private sector investments on ecosystem activity, and trends analysis.

Chinthavali, Supriya↗

Corrosion Testing of Carbon Steel Exposed to Sludge Heel Chemical Cleaning Solutions - 16109

As efforts continue to treat and dispose of millions of gallons of legacy radioactive materials from the production of nuclear weapons, non-compliant waste storage tanks will gradually be emptied of the bulk waste volume leaving heel materials requiring removal prior to tank closure. The waste heel slurries are distributed on the floor of large, million gallon tanks, which frequently contain numerous obstructions that limit the effectiveness of mechanical removal methods. As a result, chemical cleaning methods are needed for the effective removal of the heels as well as chemical scales that are present on the tank walls and other interior surfaces. Two tank cleaning technologies have already been implemented at the Savannah River Site (SRS): Low Temperature Aluminum Dissolution (LTAD) and Bulk Oxalic Acid Cleaning (BOAC). Recent chemical cleaning efforts on SRS Tank 12 were very successful with regard to bulk sludge heel (especially for Al, Fe, and U phases) and beta/gamma radionuclide removal. Although chemical cleaning using these technologies has been shown to be effective, no disposition path has been identified for oxalate added during BOAC, and insoluble oxalate salts are accumulating within the SRS tank farm and waste processing facilities (evaporators, etc.). Extensive sludge washing is also required to remove moderately soluble sodium oxalate salts prior to sludge vitrification in the SRS Defense Waste Processing Facility (DWPF). As a result, oxalate additions to the tank farm need to be minimized by the use of supplementary acids to assist sludge removal in OA or the use of other cleaning reagents or processing strategies. Previous SRNL testing revealed the importance of pH control for BOAC and recommended the use of a supplementary acid (dilute HNO{sub 3}) with OA to minimize oxalate additions. Primary drivers in SRS Tank Closure Performance Assessments, which evaluate the fate and impact of tank sludge residuals on a geological timescale, are the removal of alpha emitting radionuclides present at low concentrations such as Pu, Am, and Np, which are not highly soluble in currently utilized chemical cleaning reagents. Scoping studies conducted at SRNL revealed promising methods to dissolve the actinides within the HLW tank heels. Oxidation of the actinides with permanganate in either strong caustic (10 M NaOH) or dilute acidic (0.2 M HNO{sub 3}) solutions was shown to result in dissolution of oxy/hydroxide phases of these metals in the absence of major sludge phases. The waste tanks at SRS and Hanford are constructed of carbon steel. Carbon steel corrodes rapidly in most acidic and/or oxidizing environments. Previous electrochemical corrosion testing indicated that the corrosion rates in dilute HNO{sub 3} with OA may result in manageable corrosion rates, over short exposure periods. Additional corrosion testing was performed to provide data for the nitric acid/OA blend as well as the acid/permanganate and caustic permanganate based chemical cleaning solutions. Corrosion rates from the passive coupon tests for the nitric acid/oxalic acid blend were significantly greater than those observed previously with the electrochemical testing. This result may be due to simultaneous electrochemical and chemical dissolution of the steel. The corrosion rate data from the coupon tests in the nitric acid/oxalic acid blend were evaluated to determine the degree of potential structural damage. The corrosion rates, although relatively high, would not be expected to cause damage that would reduce the capacity of the tank primary wall if the process is completed within a month. The corrosivity of sodium permanganate in four proposed cleaning solutions, 1 nitric acid solution and 3 sodium hydroxide solutions, was studied by electrochemical methods at room temperature. The corrosion rates were significantly less aggressive than in the nitric acid/oxalic acid blend corrosion tests. Passive coupon tests needs to be performed in these solutions to ensure that chemical dissolution of the metal is not occurring simultaneously. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Passive exposures of children to volatile trihalomethanes during domestic cleaning activities of their parents

Domestic cleaning has been proposed as a determinant of trihalomethanes (THMs) exposure in adult females. We hypothesized that parental housekeeping activities could influence children's passive exposures to THMs from their mere physical presence during domestic cleaning. In a recent cross-sectional study (n=382) in Cyprus [41 children (<18y) and 341 adults (≥18y)], we identified 29 children who met the study's inclusion criteria. Linear regression models were applied to understand the association between children sociodemographic variables, their individual practices influencing ingestion and noningestion exposures to ΣTHMs, and their urinary THMs levels. Among the children-specific variables, age alone showed a statistically significant inverse association with their creatinine-adjusted urinary ΣTHMs (r{sub S}=−0.59, p<0.001). A positive correlation was observed between urinary ΣTHMs (ng g{sup −1}) of children and matched-mothers (r{sub S}=0.52, p=0.014), but this was not the case for their matched-fathers (r{sub S}=0.39, p=0.112). Time spent daily by the matched-mothers for domestic mopping, toilet and other cleaning activities using chlorine-based cleaning products was associated with their children's urinary THMs levels (r{sub S}=0.56, p=0.007). This trend was not observed between children and their matched-fathers urinary ΣTHMs levels, because of minimum amount of time spent by the latter in performing domestic cleaning. The proportion of variance of creatinine-unadjusted and adjusted urinary ΣTHMs levels in children that was explained by the matched-mothers covariates was 76% and 74% (p<0.001), respectively. A physiologically-based pharmacokinetic model adequately predicted urinary chloroform excretion estimates, being consistent with the corresponding measured levels. Our findings highlighted the influence of mothers' domestic cleaning activities towards enhancing passive THMs exposures of their children. The duration of such activities could be further tested as a valid indicator of children's THMs body burden. - Highlights: • First report on THMs exposure assessment in matched parents and children. • Duration of domestic cleaning by mothers influenced passive exposure to THMs in children. • Matched-fathers did little cleaning and thereby no contribution to passive exposure to THMs in children. • Reverse dosimetry showed a good agreement between predicted and observed urinary chloroform. • Passive exposures to THMs require new attention in survey questionnaires and epidemiology.

54 ENVIRONMENTAL SCIENCES↗

Studies on the production of ultra-clean coal by alkali-acid leaching of low-grade coals

The use of low-grade coal in thermal power stations is leading to environmental pollution due to the generation of large amounts of fly ash, bottom ash, and CO{sub 2} besides other pollutants. It is therefore important to clean the coal before using it in thermal power stations, steel plants, or cement industries etc. Physical beneficiation of coal results in only limited cleaning of coal. The increasing environmental pollution problems from the use of coal have led to the development of clean coal technologies. In fact, the clean use of coal requires the cleaning of coal to ultra low ash contents, keeping environmental norms and problems in view and the ever-growing need to increase the efficiency of coal-based power generation. Therefore this requires the adaptation of chemical cleaning techniques for cleaning the coal to obtain ultra clean coal having ultra low ash contents. Presently the reaction conditions for chemical demineralization of low-grade coal using 20% aq NaOH treatment followed by 10% H{sub 2}SO{sub 4} leaching under reflux conditions have been optimized. In order to reduce the concentration of alkali and acid used in this process of chemical demineralization of low-grade coals, stepwise, i.e., three step process of chemical demineralization of coal using 1% or 5% aq NaOH treatment followed by 1% or 5% H{sub 2}SO{sub 4} leaching has been developed, which has shown good results in demineralization of low-grade coals. In order to conserve energy, the alkali-acid leaching of coal was also carried out at room temperature, which gave good results.

01 COAL, LIGNITE, AND PEAT↗

ALTERNATIVE AND ENHANCED CHEMICAL CLEANING: CORROSION STUDIES RESULTS: FY2010

Due to the need to close High Level Waste storage tanks, chemical cleaning methods are needed for the removal of sludge heel materials remaining at the completion of mechanical tank cleaning efforts. Oxalic acid is considered the preferred cleaning reagent for heel dissolution of iron-based sludge. However, the large quantity of chemical reagents added to the tank farm from oxalic acid based cleaning has significant downstream impacts. Optimization of the oxalic acid cleaning process can potentially reduce the downstream impacts from chemical cleaning. To optimize oxalic acid usage, a detailed understanding of the chemistry of oxalic acid based sludge dissolution is required. Additionally, other acidic systems may be required for specific waste components that have low solubility in oxalic acid, and as a means to reduce oxalic acid usage in general. Electrochemical corrosion studies were conducted with 1 wt. % oxalic acid at mineral acid concentrations above and below the optimal conditions for this oxalic acid concentration. Testing environments included pure reagents, pure iron and aluminum phases, and sludge simulants. Mineral acid concentrations greater than 0.2 M and temperatures greater than 50 C result in unacceptably high corrosion rates. Results showed that manageable corrosion rates of carbon steel can be achieved at dilute mineral acid concentrations (i.e. less than 0.2 M) and low temperatures based on the contact times involved. Therefore, it is recommended that future dissolution and corrosion testing be performed with a dilute mineral acid and a less concentrated oxalic acid (e.g., 0.5 wt.%) that still promotes optimal dissolution. This recommendation requires the processing of greater water volumes than those for the baseline process during heel dissolution, but allows for minimization of oxalic acid additions. The following conclusions can be drawn from the test results: (1) In both nitric and sulfuric acid based reagents, the low temperature and dilute concentration environment resulted in carbon steel corrosion rates that were less than 150 mpy. These rates are manageable in that chemical cleaning processes could proceed for limited time without significant wall loss. Further optimization of the Alternative Enhance Chemical Cleaning (AECC) process should focus on testing in solutions of this dilute concentration and low temperature regime. (2) In general, for the nitric acid based reagent, the aluminum oxide phase environments resulted in higher corrosion rates than the iron oxide phase environments. (3) In general, for the sulfuric acid based reagent, the iron oxide phase environments resulted in higher corrosion rates than the aluminum oxide phase environments. (4) In general, for the nitric acid based reagent, the HM sludge simulant environments resulted in higher corrosion rates than the PUREX sludge simulant environments. This result agrees with the previous observation that the aluminum oxide phases are more aggressive than the iron oxide phase environments in the nitric acid reagent. (5) Pitting was more likely to occur in the sulfuric acid based reagents than in the nitric acid based reagents. (6) Pitting occurred only in the iron based pure oxide phases and the sludge simulants. No pitting was observed in the aluminum based pure oxide phases. (7) Pitting tended to occur more frequently in tests that involved the dilute mineral acid reagent. (8) Pitting was more severe at the higher temperature for a given mineral acid concentration. (9) Pitting was more severe at a higher mineral acid concentration for a given temperature. (10) Based on the combined results of the open circuit potential and cathodic polarization testing, there was a low propensity for hydrogen evolution in solutions where sludge has been dissolved.

08 HYDROGEN↗

A Method to Extract Soiling Loss Data from Soiling Stations with Imperfect Cleaning Schedules: Preprint

Typical PV soiling stations determine the natural soiling losses by comparing the output of a naturally soiled PV cell to that of a PV cell maintained in the clean state. Inadequate cleaning frequency or human error provides opportunity for the cleaned cell to soil, directly resulting in error in the reported soiling ratio. This work investigates an algorithm to automatically detect and correct the data stream for errors associated with soiling of the clean cell. The methodology is tested on several soiling stations with irregular cleaning schedules as well as a soiling station where both ideal and imperfect cleaning schedules are in place. The initial results show that the algorithm can reduce error associated with imperfect cleaning but also confirms the benefits of maintaining an optimal cleaning schedule.

14 SOLAR ENERGY↗

Alternate Methods for Cleaning Zirconium Plate

The United States High Performance Research Reactor Conversion Program identified the need to transition from highly enriched uranium fuel to lowly enriched uranium fuel for high power research and civil reactors. One of the fuel configurations selected for these reactors was a uranium (U) foil alloyed with 10% molybdenum (Mo). The U-10Mo fuel foil was then covered with a zirconium (Zr) interlayer and pressed into an aluminum cladding. Idaho National Laboratory prescribed a need to remove surface oxidation on the Zr prior to bonding it with U-10Mo fuel foil. To determine the best method of oxidation removal, a variety of polishing methods, including hand polishing with a diamond paste or Scotch-Brite™ pads, mechanically wet-polishing with abrasive belts, and chemical etching with hydrofluoric/nitric acid mixtures, were investigated on pre-polished Zircaloy 702 sheets purchased directly from the manufacturer. No change in surface roughness was detected using any of these methods relative to the as-received material. In fact, scanning electron microscopy detected grit from hand polishing with Amplex Grade 30 waste soluble diamond paste and Scotch-Brite™ pads. Visible staining was found, and fluorine detected via X-ray photoelectron spectroscopy on the flash etching samples. These contaminants were not seen on the as-received material. In addition to the need to remove the oxide layer on the Zr prior to co-rolling, there are concerns that the Neolube debonding agent on the co-rolling can may contaminate the Zr surface after co-rolling. The experimental results found that zirconium in contact with Neolube coated steel plates was easily cleaning with ethanol wiping after heat treated and no carbide inclusions remained on the surface. Overall, all cleaning methods tested did not significantly change the surface roughness of the plates or reduce the oxide layer present on the zirconium. Carbon was found on all the samples, before and after cleaning, except for the flash etch samples which detected fluorine instead. The insignificant changes seen in the cleaned plates relative to the as received plates question the need for cleaning prior to rolling. Further investigation in the requirements for cleaning at this step is recommended. Current methods for cleaning the surface after hot rolling with alcohol appear sufficient. After hot rolling, if Neolube does peel off the can and onto the zirconium coated foil surface, a dry abrasive or diamond paste polish is not recommended due to the chance of abrasive being embedded into the surface. However, the ability of an etchant to lift the lubricant off the zirconium surface indicates that a spot etch method could work to clean specific spots where Neolube is present, if the need arises.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultra-clean and smoky marine boundary layers frequently occur in the same season over the southeast Atlantic

We study 41 d with daily median surface accumulation mode aerosol particle concentrations below 50 cm -3 (ultra-clean conditions) observed at Ascension Island (ASI; 7.9° S, 14.4° W) between June 2016 and October 2017 as part of the Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign. Interestingly, these days occur during a period of great relevance for aerosol–cloud–radiation interactions, the southeast Atlantic (SEATL)biomass-burning season (approximately June–October). That means that these critical months can feature both the highest surface aerosol numbers, from smoke intrusion into the marine boundary layer, as well as the lowest. While carbon monoxide and refractory black carbon concentrations on ultra-clean days do not approach those on days with heavy smoke, they also frequently exceed background concentrations calculated in the non-burning season from December 2016 to April 2017. This is evidence that even what become ultra-clean boundary layers can make contact with and entrain from an overlying SEATL smoke layer before undergoing a process of rapid aerosol removal. Because many ultra-clean and polluted boundary layers observed at Ascension Island during the biomass burning season follow similar isobaric back trajectories, the variability in this entrainment is likely more closely tied to the variability in the overlying smoke rather than large-scale horizontal circulation through the boundary layer. Since exceptionally low accumulation mode aerosol numbers at ASI do not necessarily indicate the relative lack of other trace pollutants, this suggests the importance of regional variations in what constitutes an “ultra-clean” marine boundary layer. Finally, surface drizzle rates, frequencies and accumulation – as well as retrievals of liquid water path– all consistently tend toward higher values on ultra-clean days. This implicates enhanced coalescence scavenging in low clouds as the key driver of ultra-clean events in the southeast Atlantic marine boundary layer. These enhancements occur against and are likely mediated by the backdrop of a seasonal increase in daily mean cloud fraction and daily median liquid water path over ASI, peaking in September and October in both LASIC years. Therefore the seasonality in ultra-clean day occurrence seems directly linked to the seasonality in SEATL cloud properties. These results highlight the importance of two-way aerosol–cloud interactions in the region.

54 ENVIRONMENTAL SCIENCES↗