LANL Superconducting Solenoid Magnet Delivery Checks
This report contains logs and photos taken during solenoid magnet delivery checks.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This report contains logs and photos taken during solenoid magnet delivery checks.
We can use formal methods to verify that systems compose correctly without the possibility of incorrect behavior. This means exhaustively checking that System A’s postconditions agree with System B’s preconditions. If so, it is safe to compose.
This report summarizes error messages obtained from counter-checking whether 1 H, 9 Be, 12 C, 27 Al, 235,238 U and 238–242 Pu relative uncertainties of ENDF/B-VIII.0 are realistic. Large parts of this report were generated automatically by the code CovVal. This code allows to test the reliability of relative uncertainties of any isotope. It gives generic error and warning messages if evaluated relative uncertainties of a particular reaction are likely under- or over-estimated. In addition to these error and warning messages, I added comments whether the flagged uncertainties are truly under- or overestimated. I call out these uncertainties that should be further investigated and corrected by an evaluator for an upcoming release of ENDF/B-VIII.1.
China first adopted minimum energy performance standards (MEPS) in 1989. Today, there are standards for a wide range of domestic, commercial and selected industrial equipment. In 1999, China launched a voluntary endorsement label, which has grown to cover over 40 products including water-saving products. Further, in 2005, China started a mandatory energy information label that initially covered two products and in 2007 was extended to cover four products total including: air conditioners; household refrigerators; clothes washers; and unitary air conditioners. These programs have had an important impact in reducing the energy consumption of appliances in China. China has built up a strong infrastructure to develop and implement standards. Historically, however, the government's primary focus has been on the technical requirements for specifying efficiency performance. Less attention has been paid to monitoring and enforcement with a minimal commitment of resources and little expansion of administrative capacity in this area. Thus, market compliance with both mandatory standard and labeling programs has been questionable. Furthermore, actual energy savings have quite possibly been undermined as a result. The establishment of a regularized monitoring system for tracking compliance with the mandatory standard and energy information label programs in China is a major area for program improvement. Over the years, the Collaborative Labeling and Appliance Standards Program (CLASP) has partnered with several Chinese institutions to promote energy-efficient products in China. CLASP, together with its implementing partner Lawrence Berkeley National Laboratory (LBNL), has assisted China in developing and updating the above-mentioned standards and labeling programs. Because of the increasing need for the development of a monitoring system to track compliance with the standard, CLASP, with support from Japan's Ministry of Economy, Trade and Industry (METI) and the Institute of Energy Economics, Japan (IEEJ), has expanded its on-going collaboration with the China National Institute of Standards (CNIS) to include enforcement and monitoring. CNIS has already begun working on the issue of compliance. In early 2007, LBNL compiled a report, with the support of METI, summarizing the findings from these activities and indicating China's progress to date. The report concluded that although the existing legal basis for monitoring and enforcement is sufficient- with multiple laws and regulations defining the responsibility of each government agency and specifying a system of fines and penal-ties for non-compliance-compared with international best practices, there is still a big gap in China's monitoring and enforcement efforts for mandatory standards and labels. In sum, the report concludes that while the sample size is far smaller than the mid-term goal of developing a regular check testing program for 20 percent of the market for each of the three products, this study provides highly valuable feedback on manufacturer compliance rates in the absence of a large-scale national testing program. With METI/IEEJ support, CLASP could assist the China Energy Label Center (CELC) in expanding its verification testing programs to cover more models and products, and in developing a plan for ramping up the national verification testing program over the next three to five years. This is particularly important as the information labeling program gains more visibility and expands to additional product categories. CLASP could also assist CELC to plan for a round-robin testing scheme-first among three national laboratories with sub-sequent expansion of this program to other regional test laboratories--with the goal of improving the consistency of testing results from different testing laboratories.
In this note we perform a cross check of the programs used by NOvA to calculate the 3-flavor oscillation probabilities with a independent program using a different method. The comparison is performed at 6 significant figures and the agreement, $|\Delta P|/P$ is better than $10^{-5}$, as good as can be expected with 6 significant figures. In addition, a simple and accurate alternative method to calculate the oscillation probabilities is outlined and compared in the L/E range and matter density relevant for the NOvA experiment.
This is a quality checked aerosol optical depth (version 3) data ingested from Aeronet.
Lunar Spectral Deconvolution Algorithm (SDA) Retrieval Version 4.1 Level 2.0 (Quality checked and filtered )
A check valve's housing has a valve disposed therein to open or close a flow path from the housing's inlet to its outlet based on a difference between pressures at the inlet and outlet. The valve includes a bellows, a poppet, and a spring. The poppet includes a hollow structure extending through the poppet's plate and terminating in a first open end disposed within the bellows, an annular flange between the second face of the poppet's plate and the housing's outlet, and an open-ended tube extending from the annular flange into the housing's outlet. The spring, disposed within the hollow tubular structure, positions the annular flange to seal the outlet when the pressure difference is less than a predetermined amount and compresses when the difference exceeds the predetermined amount wherein the annular flange is unsealed from the housing's outlet to open the flow path.
Up-cycling Process Feasibility for Coupled Radiolytic and Biochemical Conversion of Polyethylene – Progress Check In Presentation.
The use of electrothermal vaporization (ETV) has not been readily applied to nuclear safeguards or pre inspection check (PIC) sample analysis, even though the technique is ideally suited for low level (pg) isotopic quantification due to its high analyte transport efficiency. Here demonstrate the ETV method for PIC safeguard analysis. The ETV system is an automated, commercial of the shelf (COTS) technology, with the capability to introduce solid samples to a mass spectrometer platform. The system has been shown to simultaneously determine uranium assay, and the major isotopic ratios for uranium and plutonium. The ETV unit has demonstrated analysis up to 50 samples a day autonomously. The utilization of this ETV methodology provide a secondary option to the current PIC analysis and offers high throughput, enhanced sensitivity, and broader isotopic detection platform.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Large-scale carbon dioxide capture and storage (CCS) offers the benefit of reducing CO{sub 2} emissions and thereby mitigating climate change risk, but it will also bring its own health, safety, and environmental risks. Curtis M. Oldenburg, Editor-in-Chief, considers these risks in the context of the broader picture of energy production. Over the last year, there have been major acute health, safety, and environmental (HSE) consequences related to accidents involving energy production from every major primary energy source. These are, in chronological order: (i) the Upper Big Branch (coal) Mine disaster, (ii) the Gulf of Mexico Macondo (oil) well blowout, (iii) the San Bruno (natural gas) pipeline leak and explosion, and (iv) the Fukushima (nuclear) reactor radioactivity releases. Briefly, the Upper Big Branch Mine disaster occurred in West Virginia on April 5, 2010, when natural methane in the mine ignited, causing the deaths of 29 miners, the worst coal mine disaster in the USA since 1970. Fifteen days later, the Macondo oil well in the Gulf of Mexico suffered a blowout, with a gas explosion and fire on the floating drilling platform that killed 11 people. The oil and gas continued to flow out of the well at the seafloor until July 15, 2010, spilling a total of approximately 5 million barrels of oil into the sea. On September 9, 2010, a 30-inch (76-cm) buried, steel, natural gas pipeline in San Bruno, California, leaked gas and exploded in a residential neighborhood, killing 8 people in their homes and burning a total of 38 homes. Flames were up to 1000 ft (300 m) high, and the initial explosion itself reportedly measured 1.1 on the Richter scale. Finally, on March 11, 2011, a magnitude 9.0 earthquake off the coast of Japan's main island, Honshu, caused a tsunami that crippled the backup power and associated cooling systems for six reactor cores and their spent fuel storage tanks at the Fukushima nuclear power plant. At time of writing, workers trying to bring the crisis under control have been exposed to dangerous levels of radiation, and radioactive water and particulates have been released to the sea and atmosphere. These four disasters, all of which occurred within the past 12 months, were not unprecedented; similar events differing only in detail have happened around the world before, and such events will occur again. Today, developed nations primarily use fossil fuels to create affordable energy for comforts such as lighting, heating and air-conditioning, refrigeration, transportation, education, and entertainment, as well as for powering manufacturing, which creates jobs and a wealth of material goods. In addition to the risks of the existing energy infrastructure that have become obvious through these recent disasters, there is also the ongoing risk of climate change that comes from the vast emissions of greenhouse gases, primarily CO{sub 2}, from the burning of fossil fuels. The implementation of CO{sub 2} capture and storage (CCS) will help mitigate CO{sub 2} emissions from fossil fuel energy, but it also carries with it HSE risks. In my personal interactions with the public and with students, the main concern voiced is whether CO{sub 2} could leak out of the deep reservoirs into which it is injected and rise up out of the ground, smothering people and animals at the ground surface. Another concern expressed is that CO{sub 2} pipelines could fail and cause similar gaseous plumes of CO{sub 2}. The widespread concerns about CO{sub 2} leaking out over the ground surface may be inspired by events that have happened within natural systems in equatorial Africa, in Indonesia, and in Italy. Researchers have been investigating a wide variety of HSE risks of geologic CO{sub 2} storage for some time and have determined that wells are the main potential pathways for significant leakage from the deep subsurface. I discuss the acute HSE risks of CO{sub 2} leakage through wells and from pipelines, and compare the behavior of failures in CO{sub 2} wells and pipelines with oil and gas analogues from which most of our experience derives.
Abstract not provided.
We report the Nearly Autonomous Management And Control System (NAMAC) is a comprehensive control system to assist plant operations by furnishing control recommendations to operators in a broad class of situations. This study refines a NAMAC system for making reasonable recommendations during complex loss of flow (LOF) scenarios with a validated EBR-II simulator, digital twins improved by machine-learning algorithms, a multi-attribute decision-making scheme, and a discrepancy checker for identifying unexpected recommendation effects. The performance of each NAMAC component is assessed, while the capability of NAMAC is demonstrated and evaluated in a class of LOF scenarios.
Not Available