Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALORIMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Design and Use of Calorimeters For Characterization of High-Enthalpy Flows in Arc-Heated Test Facilities

High-enthalpy, arc-heated flows used for aerothermal testing present a challenging environment for flow characterization. This paper describes the design and use of cooled dwell probes used for heat-transfer and pressure characterization of the NASA and United States Department of Defense (DoD) arc facilities located at Moffett Field, CA, and Arnold Air Force Base, TN. Dwell calorimeters designed, fabricated, and tested by Thermal Technologies, Inc. (TTI) in the NASA IHF and the USAF H1 and H2 arc test facilities provide heat flux and pressure data with excellent repeatability. These calorimeters use standard Gardon calorimeter gages and pressure ports with unique cooling systems enabling them to withstand the severe arc-heated environments for durations sufficient for acquisition of steady-state data. The TTI probes have proven very robust in the extreme aerothermal environments of these facilities. This paper provides an overview of calorimeter instruments typically used in arc facilities, discusses design features of the TTI dwell probes, presents selected data acquired by the TTI calorimeters, and provides comparisons with data acquired from using measurement techniques.

D Mark Smith↗

Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics

The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a $^{60}$Co radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Lastly we describe the instrumentation details and the operational experiences related to the sourcing test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes

The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\%\oplus~15.5\%/\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\%\oplus 64.9\%/\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and uncertainty quantification of Fuego simulations of calorimeter heating in a wind-driven hydrocarbon pool fire.

The objective of this work is to perform an uncertainty quantification (UQ) and model validation analysis of simulations of tests in the cross-wind test facility (XTF) at Sandia National Laboratories. In these tests, a calorimeter was subjected to a fire and the thermal response was measured via thermocouples. The UQ and validation analysis pertains to the experimental and predicted thermal response of the calorimeter. The calculations were performed using Sierra/Fuego/Syrinx/Calore, an Advanced Simulation and Computing (ASC) code capable of predicting object thermal response to a fire environment. Based on the validation results at eight diversely representative TC locations on the calorimeter the predicted calorimeter temperatures effectively bound the experimental temperatures. This post-validates Sandia's first integrated use of fire modeling with thermal response modeling and associated uncertainty estimates in an abnormal-thermal QMU analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the response of the ATLAS liquid argon barrel calorimeter to electrons at the 2004 combined test-beam

During summer and fall 2004, the response of a full slice of the ATLAS barrel detector to different particles was studied in controlled beam. One module of the ATLAS liquid argon barrel calorimeter - identical to the production modules and read out by the final front-end and back-end electronics - was used for electromagnetic calorimetry. This paper presents and discusses the electron performance of the LAr barrel calorimeter, including linearity, uniformity, and resolution with different amounts of material upstream the calorimeter and energies ranging from 1 to 250 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calorimeter development for the SuperNEMO double beta decay experiment

SuperNEMO is a double-β decay experiment, which will employ the successful tracker–calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-β decay isotope, reaching a sensitivity to the neutrinoless double-β decay (Ovββ) half-life of the order of 10 26 yr, corresponding to a Majorana neutrino mass of 50–100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, ΔE/E, around 3%/ $\sqrt{E9MeV)}$σ, or 7% $\sqrt{E9MeV)}$ FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. Here, we describe the R&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-assisted object condensation clustering for calorimeter shower reconstruction at CLAS12

Several nuclear physics studies using the CLAS12 detector rely on the accurate reconstruction of neutrons and photons from its forward angle calorimeter system. These studies often place restrictive cuts when measuring neutral particles due to an overabundance of false clusters created by the existing calorimeter reconstruction software. In this work, we present a new AI approach to clustering CLAS12 calorimeter hits based on the object condensation framework. The model learns a latent representation of the full detector topology using GravNet layers, serving as the positional encoding for an event’s calorimeter hits which are processed by a Transformer encoder. This unique structure allows the model to contextualize local and long range information, improving its performance. Evaluated on one million simulated $e^-$ $+$ $p$ collision events, our method significantly improves cluster trustworthiness: the fraction of reliable neutron clusters, increasing from 8.88% to 30.73%, and photon clusters, increasing from 51.07% to 64.73%. In conclusion, our study also marks the first application of AI clustering techniques for hodoscopic detectors, showing potential for usage in many other experiments.

Calorimeters↗

On the resolution of dual readout calorimeters

Dual readout calorimeters allow state-of-the-art resolutions for hadronic energy measurements. Their various incarnations are leading candidates for the calorimeter systems for future colliders. In this paper, we present a simple formula for the resolution of a dual readout calorimeter, which we verify with a toy simulation and with full simulation results. This formula can help those new to dual readout calorimetry understand its strengths and limitations. The paper also highlights that the dual readout correction works not just to compensate for binding energy loss, but also for energies escaping the calorimeter or clustering algorithm. Formulae are also presented for approximate resolutions and energy scales in terms of different sources of response.

Calorimeters↗

New development in high resolving power W-Si calorimeters

The Relativistic Heavy Ion Collider (BNL) collides heavy nuclei and creates a strongly coupled medium at unprecedented density and temperature. Characteristic event structures may be efficiently selected with calorimeters, which can provide triggers on high-pT particles, 'jets' of particles, or large transverse energy, along with precision measurements of the structures. The importance of calorimeters in studies of ultrarelativistic heavy-ion collisions was first recognized by W.Willis. The key requirements are photon identification and measurements, and high resolving power to handle extreme occupancies common to this kind of interactions. We present a fully developed and beam tested concept of the W-Si sampling calorimeter built to this specifications. Novel features of this design are concepts of silicon micromodules, use of microconnectors for the silicon alignment purposes and passive signal summation to form readout towers. A prototype calorimeter was built in collaboration between BNL and a number of University groups from USA, Russia, Korea, Finland and Czech Republic and exposed to particle beams at CERN PS and SPS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1

This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Lastly, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of shashlik electromagnetic calorimeter prototype for SoLID

A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. In conclusion, a prototype of that module will be tested soon with an electron beam at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy 3D calorimeter for use in gamma-ray astronomy based on position-sensitive virtual Frisch-grid CdZnTe detectors

Here, we will present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frisch-grid CdZnTe (hereafter CZT) detectors. This calorimeter aims to measure photons with energies from ~100 keV to 20–50 MeV . The expected energy resolution at 662 keV is better than 1% FWHM, and the photon interaction position-measurement accuracy is better than 1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section from 5×5 to 7×7 mm 2 and length of 2–4 cm. The bars are arranged in modules of 4×4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., >1 cm). Also, it allows us to use the standard (unselected) grade crystals, while achieving the energy resolution of the premium detectors and thus substantially reducing the cost of the instrument. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of γ-rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons (like a focal plane detector in a Compton camera). Also, it could provide suitable energy resolution to allow for spectroscopic measurements of γ-ray lines from nuclear decays.

47 OTHER INSTRUMENTATION↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Neutron irradiation and electrical characterisation of the first 8” silicon pad sensor prototypes for the CMS calorimeter endcap upgrade

As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures.The results on the electrical properties of the irradiated CE silicon sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a compensatable Muon Collider calorimeter with manageable backgrounds

Muon Collider detectors pose very challenging problems in detector technology due to extremely large backgrounds present in the detector volume as a result of muon decays. Current designs of a 750 GeV/c per beam Muon Collider envisage 4.28 x 10{sup 5} muon decays per meter in the beam pipe close to the interaction region. The decay electrons after intense shielding still manage to produce large backgrounds in the detector volume of low energy photons, neutrons and higher energy Bethe Heitler muons. There are 170/184/6.8/177 TeVs energy entering the detector volume per crossing due to EM particles/Muons/Mesons/Baryons respectively. We investigate the capabilities of an iron calorimeter with pixelated readout where each pixel gives a yes/no answer as to whether a charged particle passed through it or not, to solve this problem. Each pixel is individually triggered by a 'travelling gate trigger' with a gate of 2 ns where the beginning of the gate is the time of arrival of a light signal from the interaction region to the pixel. We show that such a calorimeter is compensatable and propose two schemes to compensate the digital output in software to improve the resolution of the calorimeter. We show that such a calorimeter is capable of digitizing physics signals from the interaction region and as a result, the backgrounds from the muon decays are much reduced and under control.

43 PARTICLE ACCELERATORS↗

TH-CD-BRA-09: Towards Absolute Dose Measurement in MRI-Linac and Gamma-Knife: Design and Construction of An MR-Compatible Water Calorimeter

Purpose: The purpose of this work is to design and optimize a portable Water Calorimeter (WC) for use in a commercial MRI-linac and Gamma-knife in addition to conventional radiotherapy linacs. Water calorimeters determine absorbed dose to water at a point by measuring radiation-induced temperature rise of the volume (the two are related by the medium specific heat capacity). In this formalism, one important correction factor is heat transfer correction k-ht. It compensates for heat gain/loss due to conductive and convective effects, and is numerically calculated as ratio of temperature rise in the absence of heat loss to that in the presence of heat loss. Operating at 4°C ensures convection is minimal. Methods: A commercial finite element software was used to evaluate several WC designs with different insulation materials and thicknesses; channels allowing coolant to travel around WC (to sustain WC at 4°C) were modeled, and worst-case scenario variation in the temperature of the coolant was simulated for optimization purposes (2.6 mK/s). Additionally, several calorimeter vessel design parameters (front/back glass thickness/separation, diameter) were also simulated and optimized. Optimization is based on minimizing long term calorimeter drift (24h) as well as variation and magnitude of k-ht. Results: The final selected WC design reached a modest drift of 11µK/s after 15h for the worst-case coolant temperature variation. This design consists of coolant channels being encompassed on both sides by cryogel insulation. For the MRI-linac beam, glass thickness plays the largest effect on k-ht with variation of upto 0.6% in the first run for thicknesses ranging between 0.5–1.7mm. Subsequent runs vary only within 0.1% with glass thickness. Other factors such as vessel radius and top/bottom glass separation have sub 0.1% effects on k-ht. Conclusion: An MR-safe 4°C stagnant WC appropriate for dosimetry in MRI-linac and Gamma-Knife was designed, optimized, and construction is nearly completed. NSERC Discovery Grant RGPIN-435608.

07 ISOTOPE AND RADIATION SOURCES↗

Specific features of thermocouple calorimeter application for measurements of pulsed X-ray emission from plasma

It is shown that the accuracy of time-integrated measurements of pulsed X-ray emission from hot plasma with calibrated thermocouple calorimeters is mainly determined by two factors. The first and the most important factor is heating of the filter by the absorbed X-rays; as a result, the calorimeter measures the thermal radiation of the filter, which causes appreciable distortion of the temporal profile and amplitude of the recorded signal. The second factor is the dependence of the effective depth of X-ray absorption in the dielectric that covers the entrance window of the calorimeter on the energy of X-ray photons, i.e., on the recorded radiation spectrum. The results of model calculations of the calorimeter signal are compared with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The CMS barrel calorimeter response to particle beams from 2-GeV/c to 350-GeV/c

The response of the CMS barrel calorimeter (electromagnetic plus hadronic) to hadrons, electrons and muons over a wide momentum range from 2 to 350 GeV/c has been measured. To our knowledge, this is the widest range of momenta in which any calorimeter system has been studied. These tests, carried out at the H2 beam-line at CERN, provide a wealth of information, especially at low energies. The analysis of the differences in calorimeter response to charged pions, kaons, protons and antiprotons and a detailed discussion of the underlying phenomena are presented. We also show techniques that apply corrections to the signals from the considerably different electromagnetic (EB) and hadronic (HB) barrel calorimeters in reconstructing the energies of hadrons. Above 5 GeV/c, these corrections improve the energy resolution of the combined system where the stochastic term equals 84.7 {+-} 1.6% and the constant term is 7.4 {+-} 0.8%. The corrected mean response remains constant within 1.3% rms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗