Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calibration of 2-D soil zymography for correct analysis of enzyme distribution

Soil zymography is a new technique developed to visualize two-dimensional distributions of enzyme activities. The method is composed of incubating a membrane saturated with an enzyme-specific fluorogenic substrate on a surface of the soil sample, followed by recording the membrane image generated by a fluorescent product (e.g. MUF: methylumbelliferone) in ultraviolet light. Despite its relative ease of use, performing zymography involves multiple user-made decisions that might affect the accuracy of enzyme activity estimates. Thus, unification of the zymography methodology is required for correct estimations and comparisons of various studies. We investigated the following methodological aspects of the implementation of zymography: (a) camera settings and image processing, (b) effects of evaporation and (c) calibration procedures. Camera settings (shutter speeds or exposure time) affected the intensity of background fluorescence and signal-to-noise ratios (SNR). However, because their combined effects varied depending on MUF concentrations, light and camera setting need to be optimized for the expected range of MUF concentrations prior to zymography. Evaporation of MUF solution from the membrane had no effect on fluorescence. Relations between MUF concentration and intensity of fluorescence during calibrations demonstrated a saturated pattern and were strongly affected by image noise outside the optimal range (e.g. 8–14 μm MUF pixel -1 ). We developed a new calibration approach that is based on a piecewise linear regression. The new approach accounted for specific ranges of MUF concentration and uses nonuniformly saturated membranes, reflecting the real distribution of enzyme activities in soil. The new calibration algorithm eliminated biases of the standard calibration and resulted in greater accuracy in predicting MUF concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

High-Resolution Electron-Impact Study of the Far-Ultraviolet Emission Spectrum of Molecular Hydrogen

The emission spectrum of molecular hydrogen produced by electron-impact excitation at 100 eV has been measured in the wavelength range 1140-1690 A. High-resolution, optically thin spectra (delta(lambda) = 0.136 A) of the far-ultraviolet (FUV) Lyman and Werner band systems have been obtained with a newly constructed 3 m spectrometer. Synthetic spectral intensities based on the transition probabilities calculated by Abgrall et al. are in very good agreement with experimentally observed intensities. Previous modeling that utilized Allison & Daigarno band transition probabilities with Hoenl-London factors breaks down when the transition moment has significant J dependence or when ro-vibrational coupling is significant. Ro-vibrational perturbation between upsilon = 14 of the B(sup 1)Sigma(sup +, sub u) state and upsilon = 3 of the C(sup 1)Pi(sub u) state and the rotational dependence of the transition moment in the bands of the Lyman system are examined. Complete high-resolution experimental reference FUV spectra, together with the model synthetic spectra based on the Abgrall transition probabilities, are presented. An improved calibration standard is obtained, and an accurate calibration of the 3 m spectrometer has been achieved.

Liu, Xian-Ming↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

Amer, Tahani↗

Characterization of Fresh Nuclear Fuel using Time-Of-Flight Neutrons

Neutrons offer excellent characterization capabilities for nuclear fuels and can provide non-destructive insight on micro structure, chemistry and crystallographic phase. Measurements are possible at reactors or pulsed sources, but the inherent energy resolution implicit at pulsed sources offers unique opportunities. Recent advances in 2D neutron detection enabled new capabilities of material characterization using neutron imaging and tomography for nuclear materials. Moreover, time-of-flight (TOF) neutron measurements can enable isotope specific tomography by deriving isotope densities from transmission spectra exhibiting neutron resonances, which are recorded for each pixel. Tomographic algorithms allow 3D reconstructions of the spatial distribution of isotopes, density and features in typical fuel pellet samples. The ability to select radiographs for different energies allows characterizing samples which are opaque for thermal neutrons, such as enriched fuels or fuels containing plutonium, by selecting epi-thermal neutron energies and by knowledge of the total neutron cross sections of the constituents, isotopic enrichment levels can be determined. Nuclear cross sections are typically not calculated directly and databases such as the Evaluated Nuclear Data File (ENDF) database provide this information with cross sections determined by standardized experimental measurements, such as neutron transmission measurements for individual isotopes. Utilizing the information in the ENDF database, the 'inverse' problem can be solved by assuming cross section parameters to be known parameters and areal densities can be determined. This work presents recent advances at the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL), which provides the infrastructure to handle radioactive samples, in the development of fuel characterization with TOF neutrons. Examples include recent work on prototype accident tolerant nuclear fuels (ATF). The potential application of these techniques for nondestructive examination of irradiated fuel is under consideration. Non-destructive access to materials features for specimens embedded in containers, particularly for hazardous samples, such as a radioactive nuclear fuel, is indispensable to characterize and ultimately license new fuel forms. Energy-resolve neutron imaging is a new tool for this research field. The results reported here present a new imaging technique, setting a milestone in the capabilities of measuring non-destructively absolute quantities of physical properties. The enabling physics behind this new technique are nuclear resonances. We have demonstrated how absolute areal densities can be extracted from radiographs utilizing pulsed neutron sources. This technique provides information that is otherwise difficult and costly to obtain. In the case of nuclear fuels, the results from energy-dispersive neutron imaging may guide destructive examination of irradiated fuel. This summery does not describe recent analysis, which is ongoing. Particularly, the implementation of calibration standards has improved the determination of enrichment levels without additional calibration. The analysis of the samples was performed with full tomographic reconstructions for isotope specific data and presents a first approach in absolute isotope specific 3D reconstruction. This work was predominantly funded by and received substantial support from the Fuel Cycle R and D program at Los Alamos National Laboratory. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-223: Computed Radiography Dose Measurements of External Radiotherapy Beams

Purpose: To obtain quantitative, two-dimensional dose measurements of external radiotherapy beams with a computed radiography (CR) system and to derive volume correction factors for ionization chambers in small fields. Methods: A commercial Kodak ACR2000i CR system with Kodak Flexible Phosphor Screen HR storage foils was used. Suitable measurement conditions and procedures were established. Several corrections were derived, including image fading, length-scale corrections and long-term stability corrections. Dose calibration curves were obtained for cobalt, 4 MV, 8 MV and 25 MV photons, and for 10 MeV, 15 MeV and 18 MeV electrons in a water phantom. Inherent measurement inhomogeneities were studied as well as directional dependence of the response. Finally, 2D scans with ionization chambers were directly compared to CR measurements, and volume correction factors were derived. Results: Dose calibration curves (0.01 Gy to 7 Gy) were obtained for multiple photon and electron beam qualities. For each beam quality, the calibration curves can be described by a single fit equation over the whole dose range. The energy dependence of the dose response was determined. The length scale on the images was adjusted scan-by-scan, typically by 2 percent horizontally and by 3 percent vertically. The remaining inhomogeneities after the system’s standard calibration procedure were corrected for. After correction, the homogeneity is on the order of a few percent. The storage foils can be rotated by up to 30 degrees without a significant effect on the measured signal. First results on the determination of volume correction factors were obtained. Conclusion: With CR, quantitative, two-dimensional dose measurements with a high spatial resolution (sub-mm) can be obtained over a large dose range. In order to make use of these advantages, several calibrations, corrections and supporting measurements are needed. This work was funded by the European Metrology Research Programme (EMRP) project HLT09 MetrExtRT Metrology for Radiotherapy using Complex Radiation Fields.

60 APPLIED LIFE SCIENCES↗

Measuring Pressure Has a New Standard

The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

Source record↗

Waveguide Calibrator for Multi-Element Probe Calibration

A calibrator, referred to as the spider design, can be used to calibrate probes incorporating multiple acoustic sensing elements. The application is an acoustic energy density probe, although the calibrator can be used for other types of acoustic probes. The calibrator relies on the use of acoustic waveguide technology to produce the same acoustic field at each of the sensing elements. As a result, the sensing elements can be separated from each other, but still calibrated through use of the acoustic waveguides. Standard calibration techniques involve placement of an individual microphone into a small cavity with a known, uniform pressure to perform the calibration. If a cavity is manufactured with sufficient size to insert the energy density probe, it has been found that a uniform pressure field can only be created at very low frequencies, due to the size of the probe. The size of the energy density probe prevents one from having the same pressure at each microphone in a cavity, due to the wave effects. The "spider" design probe is effective in calibrating multiple microphones separated from each other. The spider design ensures that the same wave effects exist for each microphone, each with an indivdual sound path. The calibrator s speaker is mounted at one end of a 14-cm-long and 4.1-cm diameter small plane-wave tube. This length was chosen so that the first evanescent cross mode of the plane-wave tube would be attenuated by about 90 dB, thus leaving just the plane wave at the termination plane of the tube. The tube terminates with a small, acrylic plate with five holes placed symmetrically about the axis of the speaker. Four ports are included for the four microphones on the probe. The fifth port is included for the pre-calibrated reference microphone. The ports in the acrylic plate are in turn connected to the probe sensing elements via flexible PVC tubes. These five tubes are the same length, so the acoustic wave effects are the same in each tube. The flexible nature of the tubes allows them to be positioned so that each tube terminates at one of the microphones of the energy density probe, which is mounted in the acrylic structure, or the calibrated reference microphone. Tests performed verify that the pressure did not vary due to bends in the tubes. The results of these tests indicate that the average sound pressure level in the tubes varied by only 0.03 dB as the tubes were bent to various angles. The current calibrator design is effective up to a frequency of approximately 4.5 kHz. This upper design frequency is largely due to the diameter of the plane-wave tubes.

Sommerfeldt, Scott D.↗

Experimental comparison of icing cloud instruments

Icing cloud instruments were tested in the spray cloud Icing Research Tunnel (IRT) in order to determine their relative accuracy and their limitations over a broad range of conditions. It was found that the average of the readings from each of the liquid water content (LWC) instruments tested agreed closely with each other and with the IRT calibration; but all have a data scatter (+ or - one standard deviation) of about + or - 20 percent. The effect of this + or - 20 percent uncertainty is probably acceptable in aero-penalty and deicer experiments. Existing laser spectrometers proved to be too inaccurate for LWC measurements. The error due to water runoff was the same for all ice accretion LWC instruments. Any given laser spectrometer proved to be highly repeatable in its indications of volume median drop size (DVM), LWC and drop size distribution. However, there was a significant disagreement between different spectrometers of the same model, even after careful standard calibration and data analysis. The scatter about the mean of the DVM data from five Axial Scattering Spectrometer Probes was + or - 20 percent (+ or - one standard deviation) and the average was 20 percent higher than the old IRT calibration. The + or - 20 percent uncertainty in DVM can cause an unacceptable variation in the drag coefficient of an airfoil with ice; however, the variation in a deicer performance test may be acceptable.

Olsen, W.↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

A Portable Quantitative High-Resolution Gamma System for In-Situ Waste, D and D, and Emergency Measurements - 18573

The Canberra ISOCS system has been a highly successful and technologically innovative product since its introduction about 22 years ago. The combination of field-portable HPGe detectors, flexible shield/collimator set, and accurate mathematical efficiency calibration software made in-situ gamma spectroscopy measurements very practical. Good quality in-situ measurements are economically beneficial for items that are either large or complex, in comparison to the cost, time and impracticality of extracting a sample for laboratory measurements or producing representative calibration standards. And where the item is not homogeneous [most of the time for in-situ measurement situations] an assay of a large part of the item has been shown to be more accurate than a few widely dispersed extracted samples [the normal case]. However the size, weight, cost and complexity of the full-size ISOCS system limit its usefulness in some situations. A companion device was recently introduced, and is the subject of this document. The gamma sensor is a 1 cm{sup 3} CZT detector. It is surrounded by an optional tungsten shield/collimator set with a tripod for support. The detector is powered solely by a USB connection from a laptop PC. The full power of the ISOCS efficiency calibration software can be used with this detector. This entire package is less than 15 kg, needs no cooling, and is quite rugged, in comparison to the 120 kg for ISOCS with sensitive HPGe detectors which need Liquid Nitrogen or electro-mechanical cooling. Furthermore this CZT package is about 1/3 the cost. This is a very complementary device for the many current ISOCS users, especially for quick initial evaluations or simple situations where the full energy resolution and sensitivity of the HPGe ISOCS are not needed. Operating nuclear power plants or those in the initial phases of decommissioning are prime examples. Their complex layout often precludes the deployment of the full-sized ISOCS system, whereas the CZT system can be hand-carried there and very quickly setup for a measurement. The small detector size, and therefore low efficiency, is not a disadvantage, and in many cases is an advantage due to the elevated radioactivity of the items. This can be used to assay items in tanks, spills on floors, activity on filters, waste or items in small containers, and waste in drums. In the event of an emergency, it can be quickly deployed to measure gas or liquid effluent streams, air particulate and iodine filters in the field, or even in-vivo thyroid activity. Examples of measurements at nuclear facilities are shown and discussed in further detail, along with estimated detection limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements of Hydrogen Generation Rates using a Sealed Reactor System - 19428

Sealed reactor tests were performed to measure the hydrogen generation rate (HGR) from stored radioactive waste at the Savannah River Site. HGR may be very low, on the order of 7.5 x 10{sup -13} (m{sup 3}/h)/L [that is, cubic meters of H{sub 2} generated per hour per liter of radioactive liquid waste, or 10{sup -10} (ft{sup 3}/h)/gal]. Because the estimated HGR limit of detection for an open, continuous flow, system is approximately 7.5 x 10{sup -10} (m{sup 3}/h)/L [or 10{sup -7} (ft{sup 3}/h)/gal], a more sensitive method was needed. By accumulating generated gasses in a sealed system without a continuous purge gas, the resulting concentrations can increase the sensitivity of measurement, which is based on time of heating. In 2017, Savannah River Remediation declared a Potential Inadequacy in the Safety Analysis related to the potential thermal decomposition of organics that generate hydrogen in each of three Liquid Waste facilities: Concentration, Storage and Transfer Facility, Saltstone Production Facility, and the Defense Waste Processing Facility. The research for this study concerns low activity waste of Tank 50, which feeds the Saltstone Production Facility. This study evaluated the impact of organics including formate on the generation of H{sub 2}. Samples of SRS Tank 50 waste, which is a nominal 5 molar sodium salt solution, were sealed in stainless steel reactors and held at varying temperatures, e.g., 50 deg. C, 75 deg. C, 100 deg. C, and 120 deg. C, to determine if organic compounds are decomposing into H2. The experiments included trace solids used to stabilize waste in grout, e.g., grout-premix and Blast Furnace Slag, to determine if any solid phase reactions are present, which would accelerate or inhibit the generation of H{sub 2} at these temperatures. This paper describes the sealed reactors designed and constructed at Savannah River National Laboratory and the radioactive tests that were performed to measure HGR in both oxic and anoxic atmospheres. The shakedown tests showed the sealed reactors to be leak tight and hydrogen concentrations from calibrated standards could be accurately measured. Previous simulant tests helped to perfect the test methods and better design the radioactive tests. The radioactive results showed that the rate of hydrogen generated from Tank 50 waste, over a range of temperatures from 30 deg. C up to 120 deg. C, is bounded by an empirical relation (Hu Equation) that can be used to approximate HGRs in Tank 50 radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards direct realisation of the SI unit of sound pressure in the audible hearing range based on optical free-field acoustic particle measurements

Since the introduction of the International System of Units (the SI system) in 1960, weights, measures, standardised approaches, procedures, and protocols have been introduced, adapted, and extensively used. A major international effort and activity concentrate on the definition and traceability of the seven base SI units in terms of fundamental constants, and consequently those units that are derived from the base units. In airborne acoustical metrology and for the audible range of frequencies up to 20 kHz, the SI unit of sound pressure, the pascal, is realised indirectly and without any knowledge or measurement of the sound field. Though the principle of reciprocity was originally formulated by Lord Rayleigh nearly two centuries ago, it was devised in the 1940s and eventually became a calibration standard in the 1960s; however, it can only accommodate a limited number of acoustic sensors of specific types and dimensions. International standards determine the device sensitivity either through coupler or through free-field reciprocity but rely on the continuous availability of specific acoustical artefacts. Here, we show an optical method based on gated photon correlation spectroscopy that can measure sound pressures directly and absolutely in fully anechoic conditions, remotely, and without disturbing the propagating sound field. It neither relies on the availability or performance of any measurement artefact nor makes any assumptions of the device geometry and sound field characteristics. Most importantly, the required units of sound pressure and microphone sensitivity may now be experimentally realised, thus providing direct traceability to SI base units.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Correction for GALEX Spectroscopic UV Flux Distributions from Comparisons with CALSPEC and IUE

The CALSPEC database of absolute spectral energy distributions (SEDs) from the Hubble Space Telescope is based on pure hydrogen model atmosphere calculations for three unreddened white dwarf stars and represents the current UV flux calibration standard with a precision approaching 1% for well observed stars. Following our previous work to correct International Ultraviolet Explorer (IUE) fluxes, this paper provides an average correction for the Galaxy Evolution Explorer (GALEX) spectral database that places GALEX fluxes on the current CALSPEC scale. Our correction is derived by comparing GALEX spectroscopic flux distributions with CALSPEC and corrected IUE SEDs. This recalibration is relevant for any project based on GALEX archival spectroscopic data, e.g., UV or multi-wavelength analyses, correlating GALEX spectra with other existing or future databases, and planning of new observations. The recalibration will be applied to our planned catalog of corrected GALEX SEDs.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving the Field Portability of Neutron and Gamma Counting Techniques

Savannah River National Laboratory (SRNL) puts science to work by developing techniques that better meet customers needs for in-situ measurements. There is high demand for laboratory quality measurements in field situations, improving the cost and speed for first responders and environmental monitoring. This work focused on two improvements (1) reading a signal from a neutron detector using a Raspberry Pi (2) testing the Peak-to-Valley method for determining the depth of a source in soil contamination measurements. A Raspberry Pi is a cheap, compact computer. This affordable, compact computer is able to do simple tasks that a desktop computer is able to do, like spreadsheets, browse the internet, play games and even program a simple robot. Additionally, a Raspberry Pi can run off of a battery, so it could be deployed for long term measurements in adverse conditions like neutron monitors deployed in a shipping port. Using the Raspberry Pi and libraries easily accessible on the internet, a code was written in Python that allows the Pi to keep track of how many times a button is pushed. This work will be used with the future goal of creating low power-budget neutron detectors. 1) Make sure Python was correctly installed on the Raspberry Pi. 2) Write a code that will keep track of how many times a button connected to the Pi is pressed. A code was written to use the Raspberry Pi to count the number of times the button was pushed. Moving forward the Raspberry Pi will be tested with a neutron counter. Ideally, each signal from the neutron pulse will be equivalent of 'push the button' and be counted. In the characterization of a soil contamination area both the location and the depth of the source is important. Attenuation of the source by the soil can make determining its depth challenging, particularly for monoenergetic radionuclides like Cs-137. To address this issue, a method of calculating the 'peak-to-valley' ratio of the gamma count spectra is implemented to help calculate the known depth of the source. 1) Determine the 'peak-to-valley' ratio of a Cs-137 source at different depths. 2) Find an appropriate function to serve as a model for the peak-to-valley ratio as a function of depth. Several Petri dishes, filled with sand, were stacked with one containing a Cs-137 source. The individual Petri dishes allowed for the source to be placed at different depths. A bucket was placed over the sand and source, to keep the detector at a consistent height. A Petri dish containing a Eu-155 source, which acted as an internal calibration standard, was placed on top of the bucket. A NaI detector was place on top of the Eu-155 source and the assembly was surrounded by a tungsten shield. Count times were 20 minutes and the data was analyzed using PeakEasy. Data was recorded for Cs-137 at a series of depths in sand. Both exponential and logarithmic functions provided a reasonable fit to the data. The experimental data showed a decreasing 'peak-to-valley' ratio as the depth was increased. The next steps for this project involves determining the optimum fit function and combining the results from sand to different soil types to get a better representation of the soil found at SRS. Eventually, the peak-to-valley ratio will be used to estimate the depth of contamination in field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of single particle sizing velocimeters using photomask reticles

The development of photomask reticle calibration standards for single particle instruments is discussed. The calibration method studied involves the use of photomask reticles where the particle artifacts are actually disks of chrome thin film in the clear field reticles produced by photolithography and etching processes. Consideration is given to various aspects of theory, design, and performance.

Hirleman, E. D.↗