Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral irradiance calibration in the infrared. I - Ground-based and IRAS broadband calibrations

Absolutely calibrated versions of realistic model atmosphere calculations for Sirius and Vega by Kurucz (1991) are presented and used as a basis to offer a new absolute calibration of infrared broad and narrow filters. In-band fluxes for Vega are obtained and defined to be zero magnitude at all wavelengths shortward of 20 microns. Existing infrared photometry is used differentially to establish an absolute scale of the new Sirius model, yielding an angular diameter within 1 sigma of the mean determined interferometrically by Hanbury Brown et al. (1974). The use of Sirius as a primary infrared stellar standard beyond the 20 micron region is suggested. Isophotal wavelengths and monochromatic flux densities for both Vega and Sirius are tabulated.

Cohen, Martin↗

Photometric calibration of the HST wide-field/planetary camera. II - Ground-based observations of calibration fields

Ground-based CCD observations have been made simulating the photometric properties of the Wide Field/Planetary Camera (WF/PC) of the Hubble Space Telescope. This paper gives results in 15 of the most important WF/PC passbands for two fields chosen to provide efficient in-flight calibration of the WF/PC. These calibration fields are located in the outskirts of the globular clusters Omega Cen and NGC 6752.

Harris, Hugh C.↗

PHILLS Vicarious Calibration: A WFS Experiment and Guidance for LEO-15 Calibration Efforts

On April 24, 2001, Florida Shelf Lagrangian Experiment (FSLE) cruises were accompanied by PHILLS hyperspectral overflights at 30,000 ft altitude. Robert Steward, and Jim Ivey collected remote sensing reflectance and water samples for absorption during two FSLE experiments. The PHILLS was flown on several transects over the area with vicarious calibration measurements conducted by USF from the R/V LINK. The USF slow-drop package was also deployed to collect inherent and apparent optical properties as a function of depth for an evaluation of effects of vertical structure on remote sensing spectra. The PHILLS imagery has been successfully calibrated. We show the procedures, results, derived bathymetry, and some noise effects with a 3 s period.

Carder, Kendall L.↗

The Calibration of AVHRR/3 Visible Dual Gain Using Meteosat-8 as a MODIS Calibration Transfer Medium

This viewgraph presentation reviews the NOAA-17 AVHRR visible channels calibrated against MET-8/MODIS using dual gain regression methods. The topics include: 1) Motivation; 2) Methodology; 3) Dual Gain Regression Methods; 4) Examples of Regression methods; 5) AVHRR/3 Regression Strategy; 6) Cross-Calibration Method; 7) Spectral Response Functions; 8) MET8/NOAA-17; 9) Example of gain ratio adjustment; 10) Effect of mixed low/high count FOV; 11) Monitor dual gains over time; and 12) Conclusions

Avey, Lance↗

Swift Mission Gyro Patch and Re-Calibration Without A Calibration Campaign

The Swift spacecraft has three Two-Axis-Rate-Assemblies (TARAs) (designated as TARA 1, TARA 2, and TARA 3, and generically referred to as gyros) which until March of 2024 were all used in rate estimation as an operational workaround (dubbed “corrector-gyro”) of a software defect discovered in 2007. TARA 1 performance degraded throughout 2023 and 2024, making it an unreliable rate source. It was determined that shifting TARA 1 to be the corrector-gyro and using mainly TARAs 2 and 3, with the existing flight software (FSW) defect, would not meet performance requirements for science operations. Rather the FSW was patched to remove the defect found in 2007. This patch was delivered by the vendor in 2009, but was not fully tested or installed at that time. A decision was made in 2024 to install the patch despite limited simulation and testing capabilities. The problem facing the team was to come up with a set of alignment parameters that would work with the new patch, using data from the spacecraft operating normally in the old configuration. Calibration activities would have been possible in either the old or new FSW configuration, but were ultimately deemed unnecessary, saving staff time and pre-serving time on the spacecraft for science data collection. This paper describes the old and new FSW configurations related to gyro processing and alignment, and how the raw gyro and star tracker data from normal operation were used with a multidimensional unconstrained nonlinear minimization in MATLAB (Nelder-Mead1) to produce a fully calibrated set of gyro alignment parameters compatible with the patched FSW. Flight data is presented showing that not only did the process work, it improved performance significantly, rivaling the best slew performance of the mission to date.

MATLAB↗

Development of a Low-Level Ar-37 Calibration Standard

Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiate powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty in Measurement. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.

Absolute radiation measurement↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy: Simulation of NIST air-kerma rate eBT calibration standard

Purpose: Dosimetry for the model S700 50 kV electronic brachytherapy (eBT) source (Xoft, Inc., a subsidiary of iCAD, San Jose, CA) was simulated using Monte Carlo (MC) methods by Rivard et al. [“Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-ray source: An electronic brachytherapy source,” Med. Phys. 33, 4020–4032 (2006)] and recently by Hiatt et al. [“A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model,” Med. Phys. 42, 2764–2776 (2015)] with improved geometric characterization. Additionally, while these studies examined the dose distribution in water, there have not previously been reports of the eBT source calibration methods beyond that recently reported by Seltzer et al. [“New national air-kerma standard for low-energy electronic brachytherapy sources,” J. Res. Natl. Inst. Stand. Technol. 119, 554–574 (2014)]. Therefore, the motivation for the current study was to provide an independent determination of air-kerma rate at 50 cm in air K air (d = 50 cm) using MC methods for the model S700 eBT source. Methods: Using CAD information provided by the vendor and disassembled sources, an MC model was created for the S700 eBT source. Simulations were run using the mcnp6 radiation transport code for the NIST Lamperti air ionization chamber according to specifications by Boutillon et al. [“Comparison of exposure standards in the 10-50 kV x-ray region,” Metrologia 5, 1–11 (1969)], in air without the Lamperti chamber, and in vacuum without the Lamperti chamber. K air (d = 50 cm) was determined using the *F4 tally with NIST values for the mass energy-absorption coefficients for air. Photon spectra were evaluated over 2π azimuthal sampling for polar angles of 0° ≤ θ ≤ 180° every 1°. Volume averaging was averted through tight radial binning. Photon energy spectra were determined over all polar angles in both air and vacuum using the F4 tally with 0.1 keV resolution. A total of 10 11 simulated histories were run for the Lamperti chamber geometry (statistical uncertainty of 0.14%), with 10 10 histories for the in-air and in-vacuum simulations (statistical uncertainty of 0.04%). The total standard uncertainty in the calculated air-kerma rate determination amounted to 6.8%. Results: MC simulations determined the air-kerma rate at 50 cm from the source with the modeled Lamperti chamber to be (1.850 ± 0.126) × 10 -4 Gy/s, which was within the range of K air (d = 50 cm) values (1.67–2.11) × 10 -4 Gy/s measured by NIST. The ratio of the photon spectra in air and in vacuum were in good agreement above 13 keV, and for θ < 150° where the influence of the Kovar sleeve and the Ag epoxy components caused increased scatter in air. Below 13 keV, the ratio of the photon spectra in air to vacuum exhibited a decrease that was attributed to increased attenuation of the photons in air. Across most of the energy range on the source transverse plane, there was good agreement between the authors' simulated spectra and that measured by NIST. Discrepancies were observed above 40 keV where the NIST spectrum had a steeper fall-off towards 50 keV. Conclusions: Through MC simulations of radiation transport, this study provided an independent validation of the measured air-kerma rate at 50 cm in air at NIST for the model S700 eBT source, with mean results in agreement within 3.3%. Lastly, this difference was smaller than the range (i.e., 23%) of the measured values.

61 RADIATION PROTECTION AND DOSIMETRY↗

Moment Magnitudes of Local/Regional Events from 1D Coda Calibrations in the Broader Middle East Region [Moment Magnitudes of Small to Moderate Size Regional Events from Coda Calibration in the Broader Middle East]

Reliable moment magnitude estimates for seismic events in the Middle East region can be difficult to obtain due to the uneven distribution of stations, the complex tectonic structure, and regions of high attenuation. In this paper, we take advantage of the many new broadband seismic stations that have become available through improved national networks and numerous temporary deployments. We make coda envelope-amplitude measurements for 2247 events recorded by 68 stations over 13 narrow frequency bands ranging between 0.03 and 8 Hz. The absolute scaling of these spectra was calculated based on independent waveform modeling solutions of the moment magnitudes for a subset of these events to avoid circularity. Using our 1D path calibrations, we determined coda-based magnitudes for a majority of the events. We obtain fairly good agreement with waveform-modeled seismic moments for the larger events (Mw>4.5) at low frequencies (<0.7 Hz). As expected, the coda-derived source spectra become increasingly scattered at higher frequencies (>0.7 Hz) because of unaccounted 2D path effects, as well as mixing of both Sn coda and Lg coda, which have different attenuation behavior. This scatter leads to increased variance in the magnitudes estimated for smaller events in which low-frequency amplitudes are below the noise levels and the higher frequencies are the only signals available. We quantify the expected variance in coda envelope amplitudes as a function of frequency using interstation scatter as our metric. Finally, the net results of this study provide thousands of new 1D coda magnitude estimates for events in the broad region, as well as the necessary initial starting model for use in a new related 2D coda study (Pasyanos et al., 2016).

58 GEOSCIENCES↗

Energy Reconstruction and Calibration of the MicroBooNE LArTPC

The Liquid Argon Time Projection Chamber (LArTPC) is increasingly becoming the chosen technology for current and future precision neutrino oscillation experiments due to its superior capability in particle tracking and energy calorimetry. In LArTPCs, calorimetric information is critical for particle identification, which is the foundation for the neutrino cross-section and oscillation measurements as well as searches for beyond standard model physics. One of the primary challenges in employing LArTPC technology is characterizing its performance and quantifying the associated systematic uncertainties. MicroBooNE, the longest operating LArTPC to date, has performed numerous such measurements, including studies of detector physics and electromagnetic shower reconstruction. Here we present results on the operation and performance of the detector during its data taking, highlighting accomplishments toward calorimetric reconstruction, calibration, and detector physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibrating the simple biosphere model for Amazonian tropical forest using field and remote sensing data. I - Average calibration with field data

Using meteorological and hydrological measurements taken in and above the central-Amazon-basin tropical forest, calibration of the Sellers et al. (1986) simple biosphere (SiB) model are described. The SiB model is a one-dimensional soil-vegetation-atmosphere model designed for use within GCMs models, representing the vegetation cover by analogy with processes operating within a single representative plant. The experimental systems and the procedures used to obtain field data are described, together with the specification of the physiological parameterization required to provide an average description of data. It was found that some of the existing literature on stomatal behavior for tropical species is inconsistent with the observed behavior of the complete canopy in Amazonia, and that the rainfall interception store of the canopy is considerably smaller than originally specified in the SiB model.

Sellers, Piers J.↗