Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CABLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

INTER-DIGITAL CAPACITIVE SENSOR FOR EVALUATING CABLE INSULATION THROUGH JACKET

Interdigital capacitive (IDC) sensors have previously been used to measure cable-age/damage indicative dielectric properties of cable insulation when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket precluding direct contact with the insulation. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, an IDC to measure the effect of cable polymer dielectric change through a covering jacket has been developed. The IDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. On one electrode, the gap is 5 mm while on the other, the gap is 2 mm. Electric field depth-of-field penetrations are similar to the electrode gaps. The electrodes are printed on a flexible substrate that can be conformed to the outside jacketed surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. For jacketed cable systems, the IDC response is dominated by the jacket but, by analyzing measurements from IDC sensors with different depths-of-field penetration into the cable under test, the influence of the cable jacket material (primarily influenced by the shallow-depth-of field IDC) can be separated from the deeper-depth-of-field IDC sensing the combined effects of both jacket and underlying insulation. No other NDE method is known that is capable of sensing insulation dielectric properties through an overlying jacket.

Cable NDE, Interdigital Capacitance, Insulation Pe↗

Lightweight, flexible, high-performance carbon nanotube cables made by scalable flow coating

Coaxial cables for data transmission are ubiquitous in telecommunications, aerospace, automotive, and robotics industries. Yet, the metals used to make commercial cables are unsuitably heavy and stiff. These undesirable traits are particularly problematic in aerospace applications, where weight is at a premium and flexibility is necessary to conform with the distributed layout of electronic components in satellites and aircraft. The cable outer conductor (OC) is usually the heaviest component of modern data cables; therefore, exchanging the conventional metallic OC for lower weight materials with comparable transmission characteristics is highly desirable. Carbon nanotubes (CNTs) have recently been proposed to replace the metal components in coaxial cables; however, signal attenuation was too high in prototypes produced so far. Here, we fabricate the OC of coaxial data cables by directly coating a solution of CNTs in chlorosulfonic acid (CSA) onto the cable inner dielectric. This coating has an electrical conductivity that is approximately 2 orders of magnitude greater than the best CNT OC reported in the literature to date. In conclusion, this high conductivity makes CNT coaxial cables an attractive alternative to commercial cables with a metal (tin-coated copper) OC, providing comparable cable attenuation and mechanical durability with a 97% lower component mass.

36 MATERIALS SCIENCE↗

The initial appraisal of buried DAS system in CO2CRC Otway Project: the comparison of buried standard fibre-optic and helically wound cables using 2D imaging

This study aims to assess the ability of shallow distributed acoustic sensing (DAS) to serve as a cost-effective seismic sensor array for permanent monitoring applications. To this end, as part of the CO2CRC seismic monitoring program, a fibre-optic DAS array was deployed alongside a permanently buried geophone array at the Otway Project site (Victoria, Australia). The DAS array consisted of a standard commercially available tactical fibre-optic cable, which was deployed in 0.8m deep trenches. A custom-designed helically wound (HW) cable was also deployed in one of the DAS trenches for comparison of the cable designs. Simultaneous acquisition of the seismic data was carried out using 3000 vibroseis source points and geophones, DAS standard and HW cables. For initial assessment of the seismic images acquired with DAS and to compare different cable designs, preliminary 2D seismic reflection processing is conducted on both DAS cables and geophone data along a single 2D line. The geophone data processing guided processing of the DAS data. Several shallow structures (100-450ms) and some important reflectors at 450-600ms are observed on the final DAS images. Comparison of the two different DAS cable types demonstrated that seismic imaging would benefit DAS technology. However, the benefit of utilising HW cable is modest compared with the standard cable. The workflows and results of this study pave the way for processing of the 3D seismic data set acquired with the DAS array, as well as further detailed analysis of the DAS cables and the system itself.

47 OTHER INSTRUMENTATION↗

Dose Rate Effects on Degradation of Nuclear Power Plant Electrical Cable Insulation at a Common Dose

The intent of this report is to address an identified knowledge gap in relating accelerated aging of nuclear electrical cables to service aging: dose rate effects (DRE). Here, DRE refer to gamma radiation-induced polymer degradation being a function of dose rate in addition to total absorbed dose. The concern raised is that historical qualification conducted at higher dose rates to simulate service lifetime may underestimate insulation degradation that occurs at lower dose rates in service. In the work described herein, common nuclear cable insulation materials—cross-linked polyethylene (XLPE) and ethylene propylene diene elastomer (EPDM)—were subjected to accelerated aging at ambient temperature (26°C) at different gamma dose rates of 100, 200 and 1800 Gy/h for select exposure durations to achieve constant total doses of 170, 210 and 300 kGy to evaluate DRE. First, the cable insulation material types investigated are described. Then, the accelerated aging experimental process involving gamma irradiation applied to the insulation specimens at room temperature and different dose rates is discussed. Then, the experimental characterization techniques used to perform this work are elucidated. These include elongation at break (EAB), mass change, yellowness index (YI), carbonyl index (CI), density, indenter modulus (IM), and relaxation constant (t). Theory of polymer degradation is discussed, and characterization results and discussion are provided. Finally, concluding remarks are made. The findings from this work and cited prior work reveal that DRE are material dependent, even between similar material categories (e.g., XLPE). In the case of the EPDM studied, degradation of ductility was observed to be greater at higher dose rate for the same total dose, indicating accelerated gamma aging to be more conservative than extended aging. Thus, conclusions regarding the conservatism of historical qualification likely require additional consideration for specific materials and conditions in question. The results of this study support the contention that, due to inherent limitations and uncertainties associated with prediction of cable remaining useful life from accelerated aging experiments, trending of installed cable insulation health status will be more practical and useful for safe and efficient cable aging management repair and replace decisions than lifetime prediction from historical qualification. The combination of material robustness demonstrated by the qualification process and ongoing monitoring of cable health status combine to provide confidence in continued safe use of existing nuclear cables. Additional research into effective and efficient condition monitoring methods for non-destructive evaluation of installed cables is needed to support aging cable management, including material studies to inform interpretation of measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Diameter Quality Control of Nb 3 Sn Wires for MQXF Cables in the USA

During this project, the 0.850 ± 0.003 mm Nb 3 Sn wires for the low-beta quadrupole magnets 'MQXFA' procured for the U.S. LHC Accelerator R&D Program (LARP) and the U.S. High Luminosity LHC Accelerator Upgrade Project (US HL-LHC AUP, or simply AUP) are received at Lawrence Berkeley National Laboratory (LBNL). There, the wires are respooled and then fabricated into Rutherford cables for winding coils. As part of the quality control program, AUP obtains from the wire manufacturer values of the maximum, average, minimum, and standard deviation of the two orthogonal axes, which are assessed prior to shipment approval. At LBNL, a dual-axis optical micrometer is used to measure the wire diameter of each spool every ~30 cm prior to cabling. This helps decide whether wire pieces with abnormal diameters should be distributed across the cable cross section, in order to improve cable parameter quality and mechanical stability consistency. This paper presents: 1) diameter data of LARP cables and of the first AUP cables made using wires acquired under LARP; 2) our deviation acceptance/rejection justification; and 3) the impact of wire diameter statistics on cable fabrication.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and performance of high-temperature superconducting CORC ® cables with CFD REBCO tapes

Abstract Increasing the normal zone propagation velocity (NZPV) in superconducting cables based on rare earth barium copper oxide (REBCO) tapes is expected to cause a paradigm shift by enabling the development of faster and more reliable quench detection systems to mitigate the development of destructive hot spots. Furthermore, a higher NZPV is beneficial in terms of fault current limitation capabilities by accelerating the homogenization of the quench in superconducting power devices. One way envisioned to increase the NZPV of cables based on REBCO tapes is the current flow diverter (CFD) concept. A Conductor on Round Core (CORC ® ) cable made with CFD REBCO tapes, called CFD CORC ® cable, and a CORC ® cable made with regular REBCO tapes, were fabricated and tested. The critical current of the CFD and regular CORC ® cables were obtained at temperatures ranging from 67 to 77 K in self-field. Measurements showed that the NZPV was increased by a factor of 4–4.5 in the case of the CFD CORC ® cable. Furthermore, the results suggest that the NZPV depends only on the applied current, similar to what has been observed previously on single REBCO tapes. These results demonstrate the successful integration of CFD REBCO tapes in CORC ® cables, without compromising their superconducting properties or their enhanced NZPV. The possibility of enhancing the NZPV of REBCO-based cables could facilitate quench detection, which remains an important issue in HTS magnet applications. This advancement also holds promise for the fault current limitation functionality of CORC ® cables.

Ben Saâd, Haïfa (ORCID:0000000216205364)↗

Fabrication of 8-Strand Rutherford Cables Using Roped Strands Made from Ultrafine Wires

Conventional Rutherford cables are typically made from solid round wire. While multi-stage cables have been made elsewhere, the purpose was usually to achieve a higher strand count and therefore a higher current carrying capability. In this work, we attempt to use two-stage roped strands made from ultrafine wires to fabricate Rutherford cables. The ultimate goal of this work is to obtain a very flexible cable that can wind accelerator magnet coils with a very tight bend radius in both the “easy way” (along the broad face of the cable) and the “hard way” (along the edge of the cable) in the wind-and-react manner, or wind coils with a radius typically used today but in the react and-wind manner with a much reduced degradation in critical current. We report our experience fabricating such Rutherford cables at the Lawrence Berkeley National Laboratory, and the initial findings from the analysis of the experimental cables made. We will discuss how the conventional wisdom and some rules of thumb for making Rutherford cables are no longer applicable or relevant, and the new thinking required in designing these cables.

Pong, Ian↗

Advanced Models for Nondestructive Evaluation of Aging Nuclear Power Plant Cables

Background: Nuclear power plant (NPP) cables must function correctly for proper power supply and control of the nuclear reactor. This is especially important for public and environmental safety at critical times such as during reactor shut-down following loss of coolant. Over extended periods of service, the cable insulation and jacket polymer materials suffer from degradation due to exposure to environmental stressors such as heat and ionizing radiation. The focus of this project has been the development of detailed descriptions of the way in which insulation polymers degrade, from a materials science perspective, and the development of new electrical techniques to monitor cable polymer condition nondestructively. Objectives: The objectives of this project have been to i) perform detailed characterization experiments upon cable insulation polymers that have experienced thermal and radiation exposure mimicking that received during NPP operation, including the exploration of novel cable nondestructive evaluation methods; capacitive, THz and infrared methods; ii) identify the most sensitive indicators of aging in these materials, and iii) develop advanced, validated models describing microstructural and chemical changes that are observed in cable insulation polymers due to thermal and radiation exposure. Methods: Accelerated aging was performed on the two most common United States NPP cable insulation polymers (cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR)) under various conditions of elevated temperature and gamma radiation dose. Aging mechanisms were elucidated through extensive thermal, mechanical and microscopic characterization of the aged samples, and materials modeling. Dielectric and IR spectra were measured on pristine and aged samples. Data was analyzed statistically, via multiple linear regression, partial least squares and probabilistic neural network approaches. Impact: Extant cable monitoring techniques do not deal successfully with all polymer types. This research has laid a foundation upon which new electrical nondestructive test methods for cable polymer condition monitoring may be developed, hence launching the development of new test methods for cable insulation monitoring based on measuring electrical rather than mechanical parameters. Collaboration: This project has benefitted from collaboration between experts in materials science and engineering, materials modeling, electrical engineering, and nondestructive evaluation. The majority of the characterization measurements were carried out at Iowa State University. Materials modeling was carried out primarily at Washington State University. Irradiation of samples took place at Pacific Northwest National Laboratory (PNNL), where a student intern from Iowa State was hosted for one summer, setting up the aging experiments. A research student from the University of Bologna, Italy, joined the project for their thesis research at Iowa State University with samples provided by PNNL. The project benefitted from regular involvement of senior engineers in US-based industry partners. Project investigators presented findings at various national and international conferences and workshops.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of NSI and related cable performance during tests performed in the NASA Hot Gas Facility

Some seven different configurations of the NSI and other cables were tested in the NASA-MSFC Hot Gas Facility (HGF). The tests were conducted to study what happens to the cables when they are exposed to hot flow as was the case in the first two Shuttle flights, the STS-1 and STS-2. Protection of these components is vital for various functions especially to attain proper nozzle separation. The tests in the HGF demonstrated the severity of the aerodynamic forces combined with aero heating environment on the test cables and helped, in general, to evaluate the cable wrap materials and cable mounting hardware and technique. Blastape 2 cable wrap which is adequate for thermal protection of the cables must be properly clamped at its ends. The nylon clamps (or ties) used to secure cables to metal components inside the skirt could not withstand the heating. K5NA closeout material used on the outboard surface of the aft skirt when troweled over the cables performed excellently in protecting the cables and mounting hardware.

Karu, Z. S.↗

New Life For The Cable Cars

NASA-Arnes' major recommendations involved ways of extending cable life in the interests of safety and economy. Other recommendations included redesign of the cablegripping device, substitution of modern braking mechanisms, improvements in cable pulleys and other components, and new inspection and repair procedures. Ames followed up by designing and installing new equipment to lengthen cable life, which averages only about two months. These cables-four of them for four different car routes--are endless belts, like ski lift cables, running from the downtown car barn to the end of each line. When a cable is installed, the loop is closed by splicing the ends together in a 72-footlong splice. The splice is the weakest part of the cable and a source of problems. When the car operator applies his grip while over a splice, the resulting friction sometimes causes the splice to "unbraid" and fail; this means shutting down the line until the splice can be repaired. Even when unbraiding does not occur, gripping a splice shortens cable life by friction wear. Worn cables are a safety hazard and must be replaced, which is expensive at $1.60 a foot for 10,000 to 20,000 feet of cable.

Source record↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗

Implementation and Verification of Cable Bending Stiffness in MoorDyn: Preprint

Cable bending stiffness capabilities have been added to MoorDyn to enable modeling of dynamic power cables. The relatively large motions experienced by floating wind turbines and wave energy converters pose a challenge for power cables, whose internal components provide significant bending resistance and are sensitive to deformation. The behavior and associated design considerations of power cables in these highly dynamic applications make coupled analysis relevant for design. MoorDyn is a lumped-mass mooring dynamics model that is used for floating wind energy simulation (often coupled with OpenFAST) and floating wave energy converter simulation (often coupled with WEC-Sim). Its existing line elasticity formulation considers axial stiffness only. To properly capture the dynamics of power cables, a cable bending stiffness model has been added that approximates cable curvature based on the difference in tangent vectors of adjacent line elements. The resulting bending moment is realized by applying forces on adjacent nodes, leaving the underlying lumped-mass formulation unchanged. The bending stiffness implementation is verified in static conditions against analytical solutions and then in a dynamic power cable scenario in comparison with OrcaFlex. The dynamic scenario uses prescribed motions and includes wave loadings on the cable. Results indicate correct implementation of bending stiffness and show close agreement with OrcaFlex.

50 EE - Wind and Water Power Program - Water (EE-4↗

Frequency Domain Reflectometry Modeling and Measurement for Nondestructive Evaluation of Nuclear Power Plant Cables

Cable insulation polymers are among the more susceptible materials to age-related degradation within a nuclear power plant. This is recognized by both regulators and utilities, so all plants have developed cable aging management programs to detect damage before critical component failure in compliance with regulatory guidelines. Although a wide range of tools are available to evaluate cables and cable systems, cable aging management programs vary in how condition monitoring and NDE is conducted as utilities search for the most reliable and cost-effective ways to assess cable system condition. Frequency domain reflectometry (FDR) is emerging as one valuable tool to locate and assess damaged portions of a cable system with minimal cost and only requires access in most cases to one of the cable terminal ends. This work examines a physics-based model of a cable system and relates it to FDR measurements for a better understanding of specific damage influences on defect detectability.

cable↗

A Cable Condition Monitoring Strategy for Safe and Reliable Plant Operation

Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.

36 MATERIALS SCIENCE↗

Effects of core type, placement, and width on the estimated interstrand coupling properties of QXF-type Nb 3 Sn Rutherford cables

The coupling magnetization of a Rutherford cable is inversely proportional to an effective interstrand contact resistance R eff , a function of the crossing-strand resistance R c , and the adjacent strand resistance R a . In cored cables, R eff continuously varies with W, the core width expressed as percent interstrand cover. For a series of un-heat-treated stabrite-coated NbTi LHC-inner cables with stainless-steel (SS, insulating) cores, R eff (W) decreased smoothly as W decreased from 100%, whereas for a set of research-wound SS-cored Nb 3 Sn cables, R eff plummeted abruptly and remained low over most of the range. The difference is due to the controlling influence of R c - 2.5 μΩ for the stabrite/NbTi and 0.26 μΩ for Nb 3 Sn. The experimental behavior was replicated in the R eff (W)’s calculated by the program CUDI, which (using the basic parameters of the QXF cable) went on to show in terms of decreasing W that: 1) in QXF-type Nb 3 Sn cables (R c = 0.26 μΩ), R eff dropped even more suddenly when the SS core, instead of being centered, was offset to one edge of the cable; 2) R eff decreased more gradually in cables with higher R c ’s; and 3) a suitable R eff for a Nb 3 Sn cable can be achieved by inserting a suitably resistive core rather than an insulating (SS) one.

36 MATERIALS SCIENCE↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Initiation of Experimental Campaign to Address Knowledge Gaps Related to Simultaneous Thermal and Gamma Radiation Aging of Crosslinked Polyethylene and Ethylene-Propylene Rubber Cable Insulation

Key cable knowledge gaps identified in the Expanded Materials Degradation Assessment (EMDA) volume on Aging of Cables and Cable Systems (Volume 5) specifically relate to the combined effects of thermal and gamma irradiation stresses on cable insulation materials. These include dose rate effects (DRE), inverse temperature effects (ITE), and synergistic effects (S/E). Extent of radiation-induced polymer degradation is proportional to absorbed dose, but DRE describe the phenomenon in which degree of damage is based not only on total dose, but also on the dose rate experienced during dose accumulation. This can be particularly complicated in the presence of thermal stress as a material spends more time at elevated temperature to receive the same total dose at a lower dose rate. Rates of cable polymer degradation generally increases with temperature, but ITE describes the situation in which polymer material damage under irradiation is greater at lower temperatures than at higher temperatures. Finally, S/E describe the concept that the mechanism of polymer material degradation when exposed to thermal aging and radiation aging in succession may be different than when exposed to thermal and radiation aging concurrently. The experimental campaign at the Pacific Northwest National Laboratory (PNNL) described in this report seeks to address these knowledge gaps through investigation of the degradation of relevant cable insulation materials at select conditions using controlled temperatures, dose rates and total doses. Insulation materials considered were chosen to represent those most commonly found in U.S. nuclear power plants in terms of manufacturers and polymer systems. They include products from manufactures including The Rockbestos Company; The Okonite Company; Boston Insulated Wire & Cable Company; Kerite Company; Anaconda Company; Brand Rex, Inc.; and Samuel Moore Company. The products include the most ubiquitous cross-linked polyethylene (XLPE) and ethylene-propylene rubber (EPR) classes of insulation polymer. Circulating air ovens with remote temperature sensing and control are positioned within the gamma irradiation beam to enable controlled temperatures during radiation exposure. Dose rates are controlled through repeatable positioning of specimens at determined distances from the Cobalt-60 gamma source. Total absorbed doses for comparing temperature and dose rate effects are controlled by removing samples from exposure at pre-determined time points. The effects of gamma beam geometry, source decay and attenuation due to samples, ovens and racks are determined and controlled for using local point dosimetry. The temperature, dose and dose rates selected for the experimental campaign described in this report were determined following input from a range of stakeholders and intended to balance the constraints of the experimental capabilities, available material, project timeline and project funding with the value of the effort in narrowing EMDA-identified knowledge gaps. Results from this campaign are anticipated to reduce uncertainty in the understanding of cable material degradation behavior in nuclear power plant environments and thereby support cable aging management in long term operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗