Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building thermal dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Temporally continuous thermofluidic–thermomechanical modeling framework for metal additive manufacturing

Additive manufacturing (AM) is known to generate large magnitudes of residual stresses (RS) within builds due to steep and localized thermal gradients. In the current state of commercial AM technology, manufacturers generally perform heat treatments in effort to reduce the generated RS and its detrimental effects on part distortion and in-service failure. Computational models that effectively simulate the deposition process can provide valuable insights to improve RS distributions. Accordingly, it is common to employ Computational fluid dynamics (CFD) models or finite element (FE) models. While CFD can predict geometric and thermal-fluid behavior, it cannot predict the structural response (e.g., stress–strain) behavior. On the other hand, an FE model can predict mechanical behavior, but it lacks the ability to predict geometric and fluid behavior. Thus, an effectively integrated thermofluidic–thermomechanical modeling framework that exploits the benefits of both techniques while avoiding their respective limitations can offer valuable predictive capability for AM processes. In contrast to previously published efforts, the work herein describes a one-way coupled CFD-FEA framework that abandons major simplifying assumptions, such as geometric steady-state conditions, the absence of material plasticity, and the lack of detailed RS evolution/accumulation during deposition, as well as insufficient validation of results. Here, the presented framework is demonstrated for a directed energy deposition (DED) process, and experiments are performed to validate the predicted geometry and RS profile. Both single- and double-layer stainless steel 316L builds are considered. Geometric data is acquired via 3D optical surface scans and X-ray micro-computed tomography, and residual stress is measured using neutron diffraction (ND). Comparisons between the simulations and measurements reveal that the described CFD-FEA framework is effective in capturing the coupled thermomechanical and thermofluidic behaviors of the DED process. The methodology presented is extensible to other metal AM processes, including power bed fusion and wire-feed-based AM.

42 ENGINEERING↗

Nanotubes Growth by Self-Assembly of DNA Strands at Room Temperature

Artificial biomolecular nanotubes are a promising approach to building materials mimicking the capacity of the cellular cytoskeleton to grow and self-organize dynamically. Nucleic acid nanotechnology has demonstrated a variety of self-assembling nanotubes with programmable, robust features and morphological similarities to actual cytoskeleton components. However, their production typically requires thermal annealing, which not only poses a general constraint on their potential applications but is also incompatible with physiological conditions. Here, we demonstrate that DNA nanotubes can self-assemble from a simple mixture of five short DNA strands at constant room temperature, growing for extended periods of time in bulk conditions as well as under confinement. Assembly is achieved using a monovalent salt buffer, which ensures a faithful nanoscale arrangement and avoids nanotube aggregation. We observe the formation of individual nanotubes up to 20 days with a diameter of 22 ± 4 nm and length of several tens of micrometers. We finally encapsulate the strands in microsized compartments, such as water-in-oil microdroplets and giant unilamellar vesicles serving as simple cell models. Notably, nanotubes not only isothermally self-assemble directly inside the microcompartments but also self-organize into dynamic higher-order structures resembling rings and dynamic networks. Our study provides an advantageous method for in situ assembly of programmable biomolecular scaffolds and materials using synthetic DNA strands without requirements of thermal treatment.

Chemistry↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-dependent experimental identification of inter-ELM microtearing modes in the tokamak edge on DIII-D

In a series of discharges on the DIII-D tokamak, fast vertical plasma jogs are used to induce current perturbations in the steep gradient region of the H-mode edge. These current perturbations directly influence the edge q profile, decoupling the resonant location and instability drive of pedestal-localized microtearing modes (MTMs.) By exploiting this effect, we develop and apply a new experimental technique to track the dynamical frequency evolution of MTMs in the pedestal region, providing a compelling validation of the MTM model. The frequency of potential MTMs is calculated as the Doppler-shifted electron diamagnetic frequency at rational q=m/n surfaces, showing remarkable agreement with chirped frequency behavior of n=3, 4 and 5 modes detected with fast magnetics. Data is collected throughout multiple ELM cycles in order to build robust statistics describing the time-dependent frequency evolution of MTMs, which can be explained by examining the recovery of pedestal gradients after an ELM event. MTMs have a dominant transport contribution in the electron thermal channel, so the presented results indicate that reduced models of pedestal transport must be electromagnetic in nature and constructed with accurate calculations of MTM stability; inclusion of this physics is essential for accurate predictions of the electron temperature pedestal profile. Supporting measurements of mode saturation, propagation direction and transport fingerprints are made to support the dynamic frequency determination, unambiguously and experimentally identifying MTMs in the pedestal region of DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collaborative Proposal: Improving understanding of the internal structure and dynamics of deep convection using ARM observations and large eddy simulations

Recent observational and large eddy simulation (LES) modeling studies have nearly unanimously supported the view of deep cumulus convection being composed of a series of quasi-spherical bubbles of buoyant air, known as moist thermals. Despite the prevalence of moist thermals in deep convection, a comprehensive theory for the dynamics of these structures is lacking. Most current conceptual models for cumulus convection are based on canonical scaling theories for dry thermals or plumes; however, there is considerable evidence that the behavior of moist thermals differs markedly from these theories. Furthermore, the theoretical basis for most cumulus parameterizations originates from the plume conceptual model, and therefore these parameterizations are inconsistent with the real structure of moist convection. Motivated by the aforementioned knowledge gaps, this “end-to-end” research effort use theory, observations, numerical simulations, and direct improvements to the Zhang-McFarlane (ZM) convection scheme in the global climate Community Atmosphere Model (CAM) to address the following research questions: What key environmental parameters determine whether or not shallow convection will transition into deep convection, in the context of thermal-like updrafts? What factors regulate the size of thermals within cumulus updrafts? How does vertical wind shear influence thermal behavior, and as a consequence, vertical velocity and mass flux profiles and the shallow-to-deep convective transition? What are the critical processes that determine updraft vertical velocities and their connection to the vertical mass flux profile for thermal-like updrafts? Idealized LES modeling will be used in conjunction with theoretical models for the core properties of thermal-like updrafts to better understand key processes that regulate thermal ascent rates and entrainment properties. Thermal-tracking procedures will be used to characterize the behavior of thermals within the LES, and recently developed direct measures of entrainment and detrainment will be used to quantify entrainment/detrainment rates. Building from these results, we will analyze the structure of moist thermals from hemispheric range-height indicator scans taken during the Atmospheric Radiation Measurement Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign, and from “real case” LES of CACTI events. This combined modeling and observational analysis will provide essential validation for the existing body of research on moist thermal dynamics, which is based primarily on modeling studies. With the insight gained from the aforementioned activities, we will modify the Zhang-McFarlane convection scheme to improve its representation of updraft vertical velocity and entrainment rate profiles. These process-level changes will be tested in the Community Atmosphere Model to assess the impact on global climate simulations.

54 ENVIRONMENTAL SCIENCES↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Quantum criticality and topology in non-equilibrium systems

A key goal of condensed matter physics research is to identify new phases of matter, and to understand the universal features of the phase transitions between them. In the past decade, physicists have uncovered a wealth of new phases with interesting surface properties, exemplified by the theoretical prediction and subsequent experimental discovery of topological insulators and superconductors. Traditional condensed matter systems are usually in a thermal equilibrium state and typically at very low temperature. Very recently, experimental advances have sparked interest in the non-equilibrium setting. Non-equilibrium systems can host new phases and phenomena with no equilibrium counterpart, and could also enable robust ways to build quantum memory devices to store and manipulate quantum information in a coherent manner. These phases and phenomena are inherently “dynamical”: they are described not by changes in the arrangement or structure of the constituent particles, but instead marked by sharp distinctions in how the particles move and exchange energy or quantum information. The discovery of robust non-equilibrium phases raises many fundamental questions: Can we develop a systematic theory of states of matter and of dynamical transitions between such states? How can such states be realized and probed experimentally? The main goal of this project was to explore the emergence of topological phases and quantum criticality (two cornerstones of modern condensed matter physics in equilibrium) in such non-equilibrium quantum systems. Specific goals included (1) using tensor networks to efficiently represent non-equilibrium states of matter and their phase transitions; (2) studying and designing new probes for periodically driven systems; and (3) developing analytic and numerical tools to analyze non-equilibrium topological phase transitions. Advances in these directions were achieved using novel techniques appropriate to study the non-equilibrium dynamics in many-body quantum systems combining strong interactions and randomness. Taken together, these results provide a new conceptual framework for understanding the emergence of quantum critical and topological properties in quantum systems far from thermal equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Force field for calcium sulfate minerals to predict structural, hydration, and interfacial properties

Calcium sulfates such as anhydrite, hemihydrate, and gypsum find widespread use in building materials, implants, and tissue healing. We introduce a simple and compatible atomistic force field for all calcium sulfate phases that reproduces a wide range of experimental data including lattice parameters, surface, hydration, mechanical, and thermal properties in 1% to 5% accuracy relative to experiments. The performance is several times better than prior force fields and DFT methods, which lead to errors in structures and energies up to 100%. We explain (hkl) cleavage energies, the dynamics of (hkl) water interfaces, and new insights into molecular origins of crystal-facet specific hydration and solubility. Impressive agreement of computed and experimentally measured hydration energies is shown. The models add to the Interface force field (IFF) and are compatible with multiple force fields (CHARMM, AMBER, GROMOS, CVFF, PCFF, OPLS-AA) for property predictions of sulfate-containing materials from atoms to the large nanometer scale.

36 MATERIALS SCIENCE↗

How good are learning-based control v.s. model-based control for load shifting? Investigations on a single zone building energy system

Both model predictive control (MPC) and deep reinforcement learning control (DRL) have been presented as a way to approximate the true optimality of a dynamic programming problem, and these two have shown significant operational cost saving potentials for building energy systems. Furthermore, there is still a lack of in-depth quantitative studies on their approximation levels to the true optimality, especially in the building energy domain. To fill in the gap, this paper provides a numerical framework that enables the evaluation of the optimality levels of different controllers for building energy systems. This framework is then used to comprehensively compare the optimal control performance of both MPC and DRL controllers with given computation budgets for a single zone fan coil unit system. Note the optimality is estimated based on a user-specific selection of trade-off weights among energy costs, thermal comfort and control slew rates. Compared with the best optimality we can find through expensive optimization simulations, the best DRL agent can maximally approximate the optimality by 96.54%, which outperforms the best MPC whose optimality level is 90.11%. However, due to the stochasticity, the DRL agent is only expected to approximate the optimality by 90.42%, which is almost equivalent to the best MPC. Except for Proximal Policy Optimization (PPO), all DRL agents can have a better approximation to the optimality than the best MPC, and are expected to have better approximation than the MPC with a prediction horizon of 32 steps (15 min per step). In terms of reducing energy cost and thermal discomfort, MPC can outperform the rule-based control (RBC) by 18.47%–25.44%. DRL can be expected to outperform RBC by 18.95%–25.65% ,and the best DRL control policy can outperform RBC by 20.29%–29.72%. Although the comparison of the optimality level is performed in a perfect setting, e.g., MPC assumes perfect models, and DRL assumes a perfect offline training process and online deployment process, this can shed insight on their capabilities of approximating to the original dynamic programming problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictions of Cell-to-Cell Propagation and Vent Gas Production in the Thermal Runaway of Lithium-Ion Battery Stacks

This work presents the thermal runaway propagation model LIM1TR (Lithium-ion Modeling with 1-D Thermal Runaway) as an efficient tool to predict different cell-to-cell thermal runaway propagation scenarios. Here, we explored the vent gas volume production and reaction duration highlighting the relationship between these parameters and thermal runaway propagation due to convection by the vented gases. Two metrics based on gas production rate and heating rate are utilized as good indicators of the start and end of thermal runaway. LIM1TR results are compared with and validated by experiments from the literature for single-cell and multicell array experiments of 5 Ah and 10 Ah cells. By accounting for intraparticle diffusion of reacting species in the electrodes, we were able to capture the general dynamics of thermal runaway propagation and estimate acceptable reaction durations compared with the experimental values. Simulation results further demonstrated that varying heating modes lead to distinct reaction durations, consistent with experimental observations. Vent gas volume predictions indicate the need to consider both full and partial oxidation of the electrolyte. The outcomes of this work are building blocks for further investigations of module-to-module propagation by vented gases through convective heat transfer.

25 ENERGY STORAGE↗

Energy Storage Grand Challenge: Energy Storage Market Report

As part of the Department of Energy's (DOE) Energy Storage Grand Challenge (ESGC), DOE intends to synthesize and disseminate best available energy storage data, information, and analysis to inform decision-making and accelerate technology adoption. The ESGC Roadmap provides options for addressing technology development, commercialization, manufacturing, valuation, and workforce challenges to position the United States for global leadership in the energy storage technologies of the future. This report provides a baseline understanding of the numerous, dynamic energy storage markets that fall within the scope of the ESGC via an integrated presentation of deployment, investment, and manufacturing data from the best, publicly-available sources. This report covers the following energy storage technologies: lithium ion batteries, lead acid batteries, pumped storage hydropower, comrpessed air energy storage, redox flow batteries, hydrogen, building thermal energy storage, and select long duration energy storage technologies. Not all energy storage technologies and markets could be addressed in this report. Due to the wide array of energy technologies, market niches, and data availability issues, this market report only included a select group of technologies. For example, thermal energy storage technologies are very broadly defined and cover a wide range of potential markets, technology readiness levels, and primary energy sources. In other areas, data scarcity necessitates a greater understanding of future applications and emerging science. Future efforts will update data presented in this report and be expanded to include other energy storage technologies. This data-driven assessment of the current status of energy storage markets is essential to track progress toward the goals described in the Energy Storage Grand Challenge and inform the decision-making of a broad range of stakeholders. At the same time, gaps identified through the development of this report can point to areas where further data collection and analysis could provide an even greater level of understanding of the full range of markets and technologies. Finally, numerous complementary analyses are planned, underway, or completed that will provide a deeper understanding of the specific technologies and markets covered at a high-level in this report.

25 ENERGY STORAGE↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Random Quantum Circuits

Quantum circuits—built from local unitary gates and local measurements—are a new playground for quantum many-body physics and a tractable setting to explore universal collective phenomena far from equilibrium. These models have shed light on longstanding questions about thermalization and chaos, and on the underlying universal dynamics of quantum information and entanglement. In addition, such models generate new sets of questions and give rise to phenomena with no traditional analog, such as dynamical phase transitions in quantum systems that are monitored by an external observer. Quantum circuit dynamics is also topical in view of experimental progress in building digital quantum simulators that allow control of precisely these ingredients. Randomness in the circuit elements allows a high level of theoretical control, with a key theme being mappings between real-time quantum dynamics and effective classical lattice models or dynamical processes. Many of the universal phenomena that can be identified in this tractable setting apply to much wider classes of more structured many-body dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigating shock-induced chemical reactions in Ni+Al multilayers: A continuum-based mesoscale approach with Arrhenius kinetics and artificial thermal conduction

A new continuum-based mesoscale modeling approach for shock-induced chemical reactions (SICRs) in Ni+Al multilayers is demonstrated in Sandia’s shock physics hydrocode, CTH. The approach utilizes Arrhenius-type kinetics and artificial thermal conduction. Our work builds upon previous efforts to parameterize equations of state for Ni x Al y [J. Appl. Phys. 137, 075102 (2025)], as well as simulations of inert shocks in realistic 2D microstructures [J. Appl. Phys. 137, 225301 (2025)]. To calibrate the reaction kinetics, pairs of the reaction coordinate, R′, vs time are extracted from the molecular dynamics (MD) literature. Here, the MD-informed kinetics are used to simulate the dynamic evolution of pressure and temperature in 2D mesoscale simulations. Overall, the MD-informed kinetics obtained for planar interfaces are too slow, as initial reaction is not observed on a nanosecond time scale. Even with quasi-periodic shock focusing leading to the formation of so-called “hot-spots,” the hot spots are unable to grow and coalesce using the fitted Arrhenius rate constants. However, by increasing the rate constants by two orders of magnitude, SICRs are observed at a shock pressure near 30 GPa, which is supported by experiments. Consequently, these mesoscale simulations suggest that unresolved shear-based mechanical mixing might possibly account for the discrepancies in kinetic rates, with shock-generated intense perturbations, interfacial vortical flows, and elevated temperatures serving as favorable reaction conditions. Future work will calibrate a shear-dependent reaction rate from the MD simulations with realistic interfaces that are wavy, diffuse, and disordered.

Kittell, David E. [Sandia National Laboratories (S↗