A Scoping Study to Develop a Computational Fluid Dynamics Based Model to Predict Radiological Materials Packaging Temperatures within a Generic Staging Building

The objective of this work is to perform computational fluid dynamics simulations of a ventilated radiological-material-package staging building to determine the effect of including or excluding a variety of physical effects and computational methods on both the predicted package temperatures and required computational resources. The generic building contains 640 drum-packages containing heat-generating, radiological material supported on four racks that are eight levels tall. Additionally, there is a forced ventilation system, lighting, and insulated walls. Computational models were constructed that included or excluded (a) shelving, (b) effects of unsteadiness, and (c) radiation heat transfer. Simulations with each drum modeled separately were compared to simpler simulations with sets of four drums represented by an equivalent box-package. These models employed between 106 to 107 elements. Steady state simulations predicted package temperatures that were within 0.1°C of simulations that included transient effects and required only one-eighth the computational resources. Calculations that excluded shelving predicted temperatures within 0.6°C of simulations that included shelving and required one-fourth the computational resources. Excluding radiation heat transfer systematically increased temperatures by around 1.5°C but reduced computational resources by a factor of four. The box-package model reduced the computational resources by a factor of 3, but systematically predicted higher temperatures by around 1.1°C. These results will be used to develop an efficient computational fluid dynamics model to assess the ability of different staging building designs to prevent the temperature of package components from exceeding specified limits.

42 ENGINEERING↗

Studsvik R2 materials test reactor Ad Hoc depletion strategy for the derivation of the fuel isotopic composition of the MPCMIV benchmark

The Ad Hoc Depletion Strategy elaborated by the NINE company, developed in support of the organization of the MPCMIV (Multi-physics Pellet Cladding Mechanical Interaction Validation) benchmark input and output specifications, is presented. This work aims at illustrating the strategy itself and then showing the results obtained with its application over the Studsvik R2 Testing Reactor, which is analyzed in the benchmark. The objective of the application of the strategy is to compute the fuel elements isotopic compositions at the beginning of some core loadings of interest for the benchmark. To this objective, it is necessary to implement first the simulation model of the three single assembly types and perform the infinite lattice depletions, then, to build the full core model and to perform the simulation of the core cycle. All the models and simulations were carried out with the use of the Monte Carlo particle transport code Serpent 2. Finally, the simulations results are assessed against Studsvik isotopic compositions of the fuel elements discharged from the R2 Reactor at the end of the core loading. Several assumptions were necessary during all the steps of the strategy, to overcome the lack of information regarding the core management. For this reason, the solution found at the end of the current analysis may not be completely optimized and further improvements regarding the model assumptions will be tested in a future work. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Deriving Simulation Parameters for Storage-Type Water Heaters Using Ratings Data Produced from the Uniform Energy Factor Test Procedure: Preprint

Building energy modeling (BEM) is commonly used to estimate the energy usage of residential buildings. Uses for BEM include calculating home energy ratings, demonstrating compliance with performance-based energy codes, and establishing whether designs meet voluntary program requirements, such as ENERGY STAR® qualified homes. BEM requires simulating subsystems within the building, including storage-type water heaters. To properly simulate the in-situ performance of residential storage water heaters, it is necessary to determine key water heater parameters, including the overall heat loss coefficient (UA) and conversion efficiency (?c) of the water heater, based on the rated efficiency of the water heater. The testing procedure and rating standard for residential water heaters have recently changed: the new rating standard provides a Uniform Energy Factor (UEF) rather than the Energy Factor (EF) used previously. This paper discusses how to derive the necessary model parameters from the ratings data produced from the latest test procedure.

30 DIRECT ENERGY CONVERSION↗

Model America - Arizona extract from ORNL's AutoBEM v1.1

Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM).Two sets of sample data are provided for 2,555,152 buildings located within the boundary of Arizona in the United States:Data (846.3MB *.csv) - minimalist list of each building (rows) for the following fields (columns) • ID - unique building ID • Centroid - building center location in latitude/longitude (from Footprint2D) • Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) • State_abbr - state name • Area - estimate of total conditioned floor area (ft2) • Area2D - footprint area (ft2) • Height - building height (ft) • NumFloors - number of floors (above-grade) • WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) • CZ - ASHRAE Climate Zone designation • BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards • Standard - building vintage • Sample Models (114GB*.zip by county) - OpenStudio and EnergyPlus building energy models named according to IDThis data is made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL), U.S. Dept. of Energy’s (DOE) Building Technologies Office (BTO), Office of Electricity (OE), and Biological and Environmental Research (BER).

54 ENVIRONMENTAL SCIENCES↗

BOPTest As a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

BOPTEST as a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

A New Modeling Framework for Multi-Scale Simulation of Hydraulic Fracturing and Production from Unconventional Reservoirs

This paper describes a new modeling framework for microscopic to reservoir-scale simulations of hydraulic fracturing and production. The approach builds upon a fusion of two existing high-performance simulators for reservoir-scale behavior: the GEOS code for hydromechanical evolution during stimulation and the TOUGH+ code for multi-phase flow during production. The reservoir-scale simulations are informed by experimental and modeling studies at the laboratory scale to incorporate important micro-scale mechanical processes and chemical reactions occurring within the fractures, the shale matrix, and at the fracture-fluid interfaces. These processes include, among others, changes in stimulated fracture permeability as a result of proppant behavior rearrangement or embedment, or mineral scale precipitation within pores and microfractures, at µm to cm scales. In our new modeling framework, such micro-scale testing and modeling provides upscaled hydromechanical parameters for the reservoir scale models. We are currently testing the new modeling framework using field data and core samples from the Hydraulic Fracturing Field Test (HFTS), a recent field-based joint research experiment with intense monitoring of hydraulic fracturing and shale production in the Wolfcamp Formation in the Permian Basin (USA). Below, we present our approach coupling the reservoir simulators GEOS and TOUGH+ informed by upscaled parameters from micro-scale experiments and modeling. We provide a brief overview of the HFTS and the available field data, and then discuss the ongoing application of our new workflow to the HFTS data set.

58 GEOSCIENCES↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock/COVID-19: U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

ComStock is a DOE platform, with NREL as the lead developer, that models the U.S. commercial building stock using OpenStudio/EnergyPlus to perform physics-based building energy modeling simulations. The ASHRAE Epidemic Taskforce (ASHRAE-ETF) has released several COVID-19 mitigation strategies for commercial buildings. ComStock was used to analyze the impact of four strategies on the existing commercial building stock. These strategies are upgrading to MERV-13 filters, disabling demand control ventilation (DCV), increasing minimum outdoor air to 100%, and HVAC flushing mode operation. Results show the impact of each measure on energy consumption, electric consumption, gas consumption and peak electric.

30 DIRECT ENERGY CONVERSION↗

Development and Performance Evaluation of of Active Insulation Systems using Solid-State Thermal Switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs), which dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. Sensitivity studies have provided requirements for the AIS properties and control schemes that can lead to those savings. However, materials and assembly development have not yet achieved a cost-effective product that achieves the required performance. In this study, we present the process to develop an AIS that we will install in a test hut for their performance evaluation. Minimum performance criteria of the AIS system are developed based on Rmin/Rmax ratio, required time and efficiency to switch states and cost estimate. The next step carried out during this study is creating the concept to meet the requirements, predicting the performance by simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to natural weather conditions. The selected approach uses off-the-shelf products to create a materials system that can switch R-value between R~=1 ft2·°F·h/BTU (0.18 m2·K/W) and R~=7 ft2·°F·h/BTU (1.23 m2·K/W and have a switching time of less than one minute between R-high and R-low.

Iffa, Emishaw↗

Air Return Strategies and Airborne SARS-CoV-2

Dedicated ducted air return per zone for heating, ventilating, and air-conditioning (HVAC) systems is sometimes claimed to be a superior technique over plenum return strategy from the viewpoint of exposure reduction to airborne pathogens. While both the return strategies have advantages, there is limited evidence in the literature as to which strategy is superior merely from a standpoint of building vulnerability to airborne contaminants. We performed multizonal airborne contaminant dispersion modelling using CONTAM to simulate the overall building vulnerability to airborne SARS-CoV-2 aerosols when released in an office building and evaluated the two air return strategies. Results showed that for ducted returns, maintaining negative pressure in the release zone coupled with 100% outdoor air supply can greatly reduce overall building vulnerability. However, for a building maintained under a slight positive pressure and a recirculated air percentage as low as 31%, ducted returns do not necessarily outperform plenum returns in terms of overall building vulnerability to airborne pathogens. Building-specific details and factors that are not easily represented with multizone modelling are important, making general preferential statements for either strategy difficult to make. Insights from this study can guide new construction and retrofits of buildings both during and after the COVID-19 pandemic with the aim of safe re-occupancy of buildings while keeping the buildings resilient against potential future epidemics spread by airborne agents.

Shrestha, Prateek↗

Python Library for Monte Carlo Simulations with Ab Initio and Machine-Learned Interatomic Potentials

There is a growing need in the simulation community for software that provides a transparent, reproducible, usable, and extensible (TRUE) Monte Carlo (MC) simulation framework employing energies from ab initio methods and machine-learning interatomic potentials (MLIPs). We introduce a Python library (ASE-MC) that adds Monte Carlo functionality to the Atomic Simulation Environment (ASE) package. Now, we can combine the powerful tools used to build systems and perform ab initio and MLIP in ASE with MC simulation algorithms to sample the configurational space with a concise Python script. After presenting the design philosophy, we demonstrate the flexibility of our approach using selected examples. These example simulations include liquid water described with a message-passing MLIP in the canonical and isothermal–isobaric ensembles, sampling the characteristic dihedral angle of biphenyl and comparing an MLIP to first-principles calculations, and a grand canonical Monte Carlo simulation of ammonia adsorption on Pt(111). These examples showcase the main features of the software, which include flexibility in the choice of ab initio or MLIP engine, ab initio or MLIP grand canonical MC with cavity bias insertions and deletions, the ability to add custom MC moves to the move set, and how users can condense complex MC workflows into a single Python script. Finally, this library serves as a framework for reproducible Monte Carlo simulations, facilitating easy reproduction of the work and application to new systems.

97 MATHEMATICS AND COMPUTING↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation-based assessment on stochastic load scheduling for building cooling systems

Here, to fill knowledge gaps related to stochastic load scheduling, we performed a comprehensive evaluation of the stochastic load scheduling for building cooling systems. Specifically, we studied the common uncertain variables in the load scheduling process for building cooling systems and categorized those variables based on their dynamic patterns. We then developed a generic stochastic load scheduling framework and applied it to building cooling systems that served a simulated community. This community consists of 100 heterogeneous houses and serves as a virtual testbed for evaluating the performance of stochastic load scheduling. In this evaluation, we considered representatives of uncertain variables with different dynamic patterns and included 100 realizations of the considered uncertainty in the evaluation to better catch the probability distribution of the control performance. The evaluation results suggest that deterministic load scheduling can reduce the operating energy cost by 18% but its performance can be affected by uncertainty. Stochastic load scheduling can further decrease the operating energy cost under uncertainty compared to deterministic load scheduling. We also found that the effectiveness of stochastic load scheduling in handling uncertainty is not directly associated with the number of uncertainty scenarios that are considered in its formulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-Centric key performance indicators to inform building design and operations

Building performance indicators are widely used to guide building design and track and benchmark operational performance. Traditional building performance indicators mostly focus on the energy efficiency perspective. As occupants are the primary building service recipients in residential and most commercial buildings, their comfort and wellbeing are crucial. As such, this study first identified significant attributes of occupant-centric key performance indicators (KPIs) and analyzed the diverse factors that should be considered in formulating an occupant-centric KPI. Then a suite of occupant-centric KPIs were synthesized from the review and enhancement of existing occupant-related performance metrics. The proposed occupant KPIs represent the occupant lens on three integrative aspects of building performance: resource use (including energy and water), indoor environmental quality, and human–building interactions. A simulation-based case study was conducted to demonstrate how occupant-centric KPIs can be used to quantify the impacts of building operation changes from the occupants’ point of view. Highlights: Occupant-centric metrics are currently ad hoc and limited, yet crucial to inform building design and operations. Literature was reviewed to reveal the state-of-the-art and gaps of occupant-centric metrics. A suite of occupant-centric key performance indicators (KPIs) covering five groups of building services were synthesized. Proposed occupant KPIs represent three aspects of performance: resource use and demand, occupant comfort and health, and human–building interactions. A case study using whole building simulation was conducted to demonstrate the use of occupant-centric KPIs in evaluating building operations during a power outage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Critical Metallicity of Cool Supergiant Formation. I. Effects on Stellar-mass Loss and Feedback

This paper systematically studies the relation between metallicity and mass loss of massive stars. We perform one-dimensional stellar evolution simulations and build a grid of ~2000 models with initial masses ranging between 11 and 60 M ⊙ and absolute metallicities Z between 0.00001 and 0.02. Steady-state winds, comprising hot main-sequence winds and cool supergiant winds, are the main drivers of the mass loss of massive stars in our models. We calculate the total mass loss over the stellar lifetime for each model. Our results reveal the existence of a critical metallicity Z c at Z ~ 10 –3 , where the mass loss exhibits a dramatic jump. If Z > Z c , massive stars tend to evolve into cool supergiants, and a robust cool wind is operational. In contrast, if Z < Z c , massive stars usually remain as blue supergiants, wherein the cool wind is not activated and the mass loss is generally weak. Moreover, we calculate the wind feedback in a 10 5 M ⊙ star cluster with the Salpeter initial mass function. The kinetic energy released by winds does not exhibit any significant transition at Z c because the wind velocity of a cool supergiant wind is low and contributes little to the kinetic energy. The effects of critical metallicity provide implications for the fates of metal-poor stars in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗

A Data-Driven Approach to Nation-Scale Building Energy Modeling

In 2019, 125 million U.S. residential and commercial buildings consumed $412 billion in energy bills. These buildings currently consume 40% of the nation's primary energy, 73% of electricity, 80% of energy during peak electric grid use, and responsible for 39% of greenhouse gas emissions [14]. Urban-scale building energy modeling has grown significantly in the past decade, allowing individual campuses or communities of buildings to be modeled, simulated, and cost-effective solutions for intelligent management to be identified and implemented. While traditionally limited to individual counties and usually less than 2,000 buildings, the Automatic Building Energy Modeling (AutoBEM) soft-ware suite has been developed to process unconventional, nation-scale data sources to generate unique OpenStudio and EnergyPlus models of each building. Through the use of High Performance Computing (HPC) resources, every U.S. building has been simulated. This paper showcases the data layout, node partitioning, algorithmic approaches, and analytic results that were used to create, share, and analyze 124.4 million U.S. building models.