Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Brayton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

PDC Modifications for Analysis of Gas-Cooled Reactors with Direct Helium Brayton Cycle

Capabilities of the Plant Dynamics Code (PDC) have been extended to allow steady-state and transient simulation of graphite-cooled reactors with direct helium Brayton cycle. On the cycle side, the most significant code modification is the addition of helium properties, in the format required by the code’s equations. Since the code was already formulated to handle more complex real gas properties, adding helium as working fluid that behaves like ideal gas was fairly straightforward. A reactor module was added to PDC to simulate a reactor cooled by the working fluid of the Brayton cycle. Two options are supported: channel type, typical for graphite gas-cooled reactors, and pin type, typical for light-water and liquid metal-cooled reactors. The reactor module is an extension of the electrical heater model and simulates heat deposition in the fuel and transfer of this heat from the fuel to the coolant through the matrix and tube materials. The new reactor module becomes the third option in PDC for modeling heat addition to the cycle, besides previously modeled heat addition heat exchanger and electrical heater. In addition to those changes, other minor code modifications and improvements were introduced during the work of expanding PDC to modeling of gas-cooled reactors. These modifications are summarized in the last chapter of this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technology of nuclear-Brayton space power systems

The present technology of Brayton power systems is reviewed. The potential for even higher system efficiency at the 10 KWe level is assessed as well as the potential for comparable efficiency with an output of 1 or 2 KWe. Systems accommodation of isotope decay is briefly discussed. The salient features are described for a Brayton power system based on this technology and employing the ZrH reactor. Reactor lives for this and competitive systems are compared. Growth capability with an advanced reactor is assessed. A concept for application of this technology to driving a gas-dynamic laser is described.

English, R. E.↗

Steady-state temperature distribution within a Brayton rotating unit operating in a power conversion system using helium-xenon gas

The Brayton rotating unit (BRU), consisting of a turbine, an alternator, and a compressor, was tested as part of a Brayton cycle power conversion system over a side range of steady state operating conditions. The working fluid in the system was a mixture of helium-xenon gases. Turbine inlet temperature was varied from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor discharge pressure from 20 to 45 psia, rotative speed from 32 400 to 39 600 rpm, and alternator liquid-coolant flow rate from 0.01 to 0.27 pound per second. Test results indicated that the BRU internal temperatures were highly sensitive to alternator coolant flow below the design value of 0.12 pound per second but much less so at higher values. The armature winding temperature was not influenced significantly by turbine inlet temperature, but was sensitive, up to 20 F per kVA alternator output, to varying alternator output. When only the rotational speed was changed (+ or - 10% of rated value), the BRU internal temperatures varied directly with the speed.

Johnsen, R. L.↗

Brayton heat exchange unit development program

A Brayton Heat Exchanger Unit (BHXU), consisting of a recuperator, a heat sink heat exchanger and a gas ducting system, was designed, fabricated, and tested. The design was formulated to provide a high performance unit suitable for use in a long-life Brayton-cycle powerplant. A parametric analysis and design study was performed to establish the optimum component configurations to achieve low weight and size and high reliability, while meeting the requirements of high effectiveness and low pressure drop. Layout studies and detailed mechanical and structural design were performed to obtain a flight-type packaging arrangement. Evaluation testing was conducted from which it is estimated that near-design performance can be expected with the use of He-Xe as the working fluid.

Morse, C. J.↗

Design and fabrication of the Brayton rotating unit

The Brayton rotating unit (BRU), operating on a gas bearing system, has been designed, fabricated, and demonstrated for use in a closed Brayton cycle space power conversion system. The BRU uses a binary mixture of xenon and helium (molecular weight, 83.8) as the cycle working fluid and bearing lubricating medium and was designed to produce from 2.25 to 10.5 kw sub e of 1200 Hz three-phase electrical power. The single-shaft rotating assembly operates at a design speed of 36,000 rpm and comprises a radial single-stage compressor, a four-pole Rice alternator rotor, and a radial inflow turbine. Four units, a dynamic simulator and three component research packages, were supplied to the NASA Lewis Research Center for performance testing and further development.

Davis, J. E.↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers

The experimental paralleling characteristics of two 1200 Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences. However, equilibrium could not be reached in extreme cases where alternator load differences were great and, at the same time, the phase-angle error was large (150 deg or more).

Perz, D. A.↗

Concepts for application of 500- to 2500-We Brayton power systems for shuttle-launched missions

A mini-Brayton power system in the power range of 500 to 2500 We utilizing the multihundred Watt isotope heat source was studied for use in shuttle-launched experiments. The system consists of a single closed gas loop containing a single-shaft, gas cooled, compressor-alternator turbine assembly; a heat source heat exchanger assembly; a startup battery package; an electrical control module; a recuperator; a gas radiator; and a multifoil superinsulation system. The basic configuration and major nuclear payloads for shuttle integration are discussed. It is concluded that mini-Brayton systems have low isotope inventories and high electrical output per thermal input, and have the capability of flying all earth orbital and interplanetary missions with little degradation in performance.

Block, H. B.↗

Gas-injection-start and shutdown characteristics of a 2-kilowatt to 15-kilowatt Brayton power system

Two methods of starting the Brayton power system have been considered: (1) using the alternator as a motor to spin the Brayton rotating unit (BRU), and (2) spinning the BRU by forced gas injection. The first method requires the use of an auxiliary electrical power source. An alternating voltage is applied to the terminals of the alternator to drive it as an induction motor. Only gas-injection starts are discussed in this report. The gas-injection starting method requires high-pressure gas storage and valves to route the gas flow to provide correct BRU rotation. An analog computer simulation was used to size hardware and to determine safe start and shutdown procedures. The simulation was also used to define the range of conditions for successful startups. Experimental data were also obtained under various test conditions. These data verify the validity of the start and shutdown procedures.

Cantoni, D. A.↗

Recent technology advances in the NASA-Lewis Research Center Brayton program

A review of the progress and milestones passed in the Brayton program is presented. The 2-to-15 kWe power system was successfully operated in a vacuum with a space-type radiator. Gas loop and electrical subsystem endurance tests have continued to demonstrate long-term operation with one rotating unit surpassing 10,000 hours of failure-free operation. Simplified gas-bearing designs for the rotating unit are being evaluated. Fabrication of an improved design of heat exchanger is nearing completion, and a study of more advanced heat exchanger technology is being conducted. A study was completed to investigate the applicability of Brayton technology applied to a lower power level (0.5 to 2.5 kWe) and showed potentially very attractive performance, simplicity, and low cost for a system in this power range.

Vernon, R.↗

Technology of nuclear-Brayton space power systems.

The present technology of Brayton power systems is reviewed. The potential for even higher system efficiency at the 10 kWe level is assessed as well as the potential for comparable efficiency with an output of 1 or 2 kWe. System accommodation of isotope decay is briefly discussed. The salient features are described for a Brayton power system based on this technology and employing the ZrH reactor. Reactor lives for this and competitive systems are compared. Growth capability with an advanced reactor is assessed. A concept for application of this technology to driving a gas-dynamic laser is described.

English, R. E.↗

Brayton cycle heat exchanger and duct assembly (HXDA, preliminary design and technology tests

A preliminary design of the heat exchanger and duct assembly (HXDA) for a 60 kwe, closed loop, Brayton cycle space power system is presented. This system is weight optimized within the constraints imposed by the defined structural and operational requirements. Also presented are the results of several small scale tests, directed to obtaining specific design data and/or the resolution of a design approach for long life Brayton cycle heat exchanger systems.

Coombs, M. G.↗

Design, fabrication, and performance of foil journal bearing for the brayton rotating unit

Foil bearings were designed and manufactured to replace pivoted-shoe journal bearings in an existing Brayton Cycle turbo-alternator-compressor. The design of this unconventional rotor support was accomplished within the constraints and space limitations imposed by the present machine, and the substitution of foil bearings was effected without changes or modification other machine components. A housing and a test rig were constructed to incorporate the new foil-bearing support into a unified assemble with an air-driven rotor and the gimbal-mounted thrust bearing, seals, and shrouds of an actual Brayton Rotating Unit. The foil bearing required no external pressure source, and stable self-acting rotation was achieved at all speeds up to 43,200 rpm. Excellent wipe-wear characteristics of the foil bearing permitted well over 1000 start-stop cycles with no deterioriation of performance in the entire speed range.

Licht, L.↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers.

The experimental paralleling characteristics of two 1200-Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based power systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences.

Perz, D. A.↗

Review of the NASA Brayton System Technology Program.

Summary of the research work accomplished on the Brayton space power system during the 1962-1972 period. It is shown that a great amount of Brayton system technology has been developed over this period. In addition, mission users are now seriously considering this system for use in future space missions.

Rochen, H.↗

Evaluation testing of a closed Brayton-cycle electrical-power-conversion system.

Description of the design and testing of a recuperated, closed Brayton-cycle, electrical power conversion system designated the Brayton Cycle Demonstrator (BCD). The system uses electrical heaters as a heat source, argon as the cycle working fluid, and gas-lubricated foil-type bearings. Objectives of the test program include (1) evaluation of the overall system performance characteristics and influences on spacecraft integration, (2) familiarization of personnel with operational methods, and (3) determination of system flexibility by operating at a number of off-design conditions. Results obtained to date are discussed.

Redding, T. E.↗

A power and load priority control concept as applied to a Brayton cycle turbo-electric generator.

This paper describes a system to regulate the speed and power output of a Brayton Cycle Power System under varying load. A typical user load profile is applied and a simple load priority and parasitic load is used for system regulation. Power storage is provided by batteries with charge and discharge converters to demonstrate support capability. The breadboard system is tested with the Brayton Cycle Demonstrator at the National Aeronautics and Space Administration, Manned Space Craft Center, Houston, Texas.

Kelsey, E. L.↗