Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

Role of skin blood flow and sweating rate in exercise thermoregulation after bed rest

Two potential mechanisms, reduced skin blood flow (SBF) and sweating rate (SR), may be responsible for elevated intestinal temperature (T(in)) during exercise after bed rest and spaceflight. Seven men underwent 13 days of 6 degrees head-down bed rest. Pre- and post-bed rest, subjects completed supine submaximal cycle ergometry (20 min at 40% and 20 min at 65% of pre-bed rest supine peak exercise capacity) in a thermoneutral room. After bed rest, T(in) was elevated at rest (+0.31 +/- 0.12 degrees C) and at the end of exercise (+0.33 +/- 0.07 degrees C). Percent increase in SBF during exercise was less after bed rest (211 +/- 53 vs. 96 +/- 31%; P < or = 0.05), SBF/T(in) threshold was greater (37.09 +/- 0.16 vs. 37.33 +/- 0.13 degrees C; P < or = 0.05), and slope of SBF/T(in) tended to be reduced (536 +/- 184 vs. 201 +/- 46%/ degrees C; P = 0.08). SR/T(in) threshold was delayed (37.06 +/- 0.11 vs. 37.34 +/- 0.06 degrees C; P < or = 0.05), but the slope of SR/T(in) (3.45 +/- 1.22 vs. 2.58 +/- 0.71 mg x min-1 x cm-2 x degrees C-1) and total sweat loss (0.42 +/- 0.06 vs. 0.44 +/- 0.08 kg) were not changed. The higher resting and exercise T(in) and delayed onset of SBF and SR suggest a centrally mediated elevation in the thermoregulatory set point during bed rest exposure.

NASA Discipline Cardiopulmonary↗

The effects of twelve weeks of bed rest on bone histology, biochemical markers of bone turnover, and calcium homeostasis in eleven normal subjects

This study was undertaken to examine the effects of 12 weeks of skeletal unloading on parameters of calcium homeostasis, calcitropic hormones, bone histology, and biochemical markers of bone turnover in 11 normal subjects (9 men, 2 women; 34 +/- 11 years of age). Following an ambulatory control evaluation, all subjects underwent 12 weeks of bed rest. An additional metabolic evaluation was performed after 12 days of reambulation. Bone mineral density declined at the spine (-2.9%, p = 0.092) and at the hip (-3.8%, p = 0.002 for the trochanter). Bed rest prompted a rapid, sustained, significant increase in urinary calcium and phosphorus as well as a significant increase in serum calcium. Urinary calcium increased from a pre-bed rest value of 5.3 mmol/day to values as high as 73 mmol/day during bed rest. Immunoreactive parathyroid hormone and serum 1,25-dihydroxyvitamin D declined significantly during bed rest, although the mean values remained within normal limits. Significant changes in bone histology included a suppression of osteoblastic surface for cancellous bone (3.1 +/- 1.3% to 1.9 +/- 1.5%, p = 0.0142) and increased bone resorption for both cancellous and cortical bone. Cortical eroded surface increased from 3.5 +/- 1.1% to 7.3 +/- 4.0% (p = 0.018) as did active osteoclastic surface (0.2 +/- 0.3% to 0.7 +/- 0.7%, p = 0.021). Cancellous eroded surface increased from 2.1 +/- 1.1% to 4.7 +/- 2.2% (p = 0.002), while mean active osteoclastic surface doubled (0.2 +/- 0.2% to 0.4 +/- 0.3%, p = 0.020). Serum biochemical markers of bone formation (osteocalcin, bone-specific alkaline phosphatase, and type I procollagen extension peptide) did not change significantly during bed rest. Urinary biochemical markers of bone resorption (hydroxyproline, deoxypyridinoline, and N-telopeptide of type I collagen) as well as a serum marker of bone resorption (type I collagen carboxytelopeptide) all demonstrated significant increases during bed rest which declined toward normal during reambulation. Thus, under the conditions of this study, the human skeleton appears to respond to unloading by a rapid and sustained increase in bone resorption and a more subtle decrease in bone formation.

NASA Discipline Musculoskeletal↗

Blood volume responses of men and women to bed rest

This paper reviews a series of studies that indicate that estrogens play an important role in blood volume regulation. The first study illustrates that the plasma volume (PV) of ambulatory women fluctuates during the menstrual cycle, increasing during periods of elevated estrogens. In the second study, it was shown that exogenous and endogenous elevations in blood estrogens attenuate the decrease in PV during bed rest. In the third study, the hypothesis was tested that women, who naturally have a higher blood estrogen content compared with men, will have a smaller loss of PV during bed rest. Ten men and ten women underwent a 13-day, 6 degrees head-down bed rest. Plasma volume and red cell mass (RCM) were measured before and after bed rest using 125I and 51Cr labeling, respectively. Before bed rest, the men and women had similar blood volume (BV) and PV (mL/kg body weight), but the women had a smaller (P < .01) RCM (22.2 +/- 0.9 versus 26.2 +/- 0.8 mL/kg, mean +/- SE). During bed rest, the decrease in RCM (mL/kg) was similar in men and women. However, the decrease in BV was greater in men (8.0 +/- 0.8 mL/kg versus 5.8 +/- 0.8 mL/kg), because of a greater reduction in PV (6.3 +/- 0.6 mL/kg versus 4.1 +/- 0.6 mL/kg). Because the decline in BV has been proposed to contribute to the cardiovascular deconditioning after bed rest, it is possible that women may experience less cardiac and circulatory strain on reambulation.

Review, Tutorial↗

Evaluation of Treadmill Exercise in a Lower Body Negative Pressure Chamber as a Countermeasure for Weightlessness-Induced Bone Loss: a Bed Rest Study with Identical Twins

Counteracting bone loss is required for future space exploration. We evaluated the ability of treadmill exercise in a LBNP chamber to counteract bone loss in a 30-day bed rest study. Eight pairs of identical twins were randomly assigned to sedentary control or exercise groups. Exercise within LBNP decreased the bone resorption caused by bed rest and may provide a countermeasure for spaceflight. INTRODUCTION: Bone loss is one of the greatest physiological challenges for extended-duration space missions. The ability of exercise to counteract weightlessness-induced bone loss has been studied extensively, but to date, it has proven ineffective. We evaluated the effectiveness of a combination of two countermeasures-treadmill exercise while inside a lower body negative pressure (LBNP) chamber-on bone loss during a 30-day bed rest study. MATERIALS AND METHODS: Eight pairs of identical twins were randomized into sedentary (SED) or exercise/LBNP (EX/LBNP) groups. Blood and urine samples were collected before, several times during, and after the 30-day bed rest period. These samples were analyzed for markers of bone and calcium metabolism. Repeated measures ANOVA was used to determine statistical significance. Because identical twins were used, both time and group were treated as repeated variables. RESULTS: Markers of bone resorption were increased during bed rest in samples from sedentary subjects, including the collagen cross-links and serum and urinary calcium concentrations. For N-telopeptide and deoxypyridinoline, there were significant (p < 0.05) interactions between group (SED versus EX/LBNP) and phase of the study (sample collection point). Pyridinium cross-links were increased above pre-bed rest levels in both groups, but the EX/LBNP group had a smaller increase than the SED group. Markers of bone formation were unchanged by bed rest in both groups. CONCLUSIONS: These data show that this weight-bearing exercise combined with LBNP ameliorates some of the negative effects of simulated weightlessness on bone metabolism. This protocol may pave the way to counteracting bone loss during spaceflight and may provide valuable information about normal and abnormal bone physiology here on Earth.

Twin Study↗

Hydrodynamics of Two-Phase Flows through Porous Media in Microgravity: Packed Bed Reactor Experiment onboard of the International Space Station

The objective of the Packed Bed Reactor Experiment was to develop a fundamental understanding of the hydrodynamics of two-phase flow with no phase transition through porous media in microgravity. This work describes two experimental campaigns flown on the International Space Station (ISS) that were designed to achieve the objective. This work presents the results on flow patterns observed, two-phase flow pressure drop in porous media, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work is the first to present predictive correlations of the two-phase friction factor for the different regimes identified based on the superficial liquid and gas velocity in microgravity, the first to hypothesize the different regimes based on the change in slope of the pressure gradient versus flow rate plots, the first to address the effects of the capillarity on the pressure gradient and the first to measure column holdup and assess the effective porosity based on the packing and the trapped gas bubbles. Experimental data on pressure drop in gas (N2) – liquid (water) flow show the presence of four different flow regimes in microgravity. Dispersed bubble flow (DB) and pulse (P) flow regimes are detected at high liquid flow rates, whereas at low liquid flow rates “large bubble” or elongated bubble (LB) and “gas channeling” (GC) regimes are observed. For these different flow regimes, different two-phase flow friction factor and pressure gradient correlations are presented for the first time as a function of the gas and liquid modified Reynolds numbers and Suratman number. Within the viscous-capillary (V-C) regime, it is found that the capillary contribution is the dominant force that contributes to the pressure drop for the wetting case (glass). However, for the non-wetting packing (Teflon), the viscous contribution dominates. It was found that the gas hold-up and pressure drop are functions of bed history at low liquid and gas flow rates with the magnitude of the hysteresis decreasing with increasing flow rates. PBRE-2 results show that the capillary force is a strong function of the superficial liquid velocity but is a much weaker function of the superficial gas velocity and varies inversely with the particle diameter. Within the Viscous-Capillary (V-C) regime, over 90% of the pressure gradient is attributed to the capillary contribution in the gas continuous regime. However, in the large bubble regime, the viscous and capillary contributions were comparable. After the completion of PBRE-2 with glass spherical beads, another bed packed with alumina was installed. Pressure gradient data for the alumina packed bed (PBRE-Water Recovery) were transferred to the PI and were not analyzed by the authors of this work. The Packed Bed Reactor Experiment concluded its on-orbit operation after two successful campaigns of testing in 2017 and in 2021. The flight hardware was brought back from orbit and is being reconditioned for a series of future experiments referred to as PBRE-WRS in support of water recovery (WRS). The WRS series consists of testing different two-phase fluid system components and packed beds to assess their pressure gradient characteristics, which will be used for designing packed bed reactors for various applications relevant to life support. Although there is so much relevance of the experimental results obtained from the two PBRE campaign in microgravity to life support, these findings also apply to other applications that involve two phase flow in porous medium such as fuel cells, transport of nutrient to plants in space and other chemical and materials processing that involve two phase flows. These systems operate differently in microgravity because, due to the lack of buoyancy, the density difference between the phases becomes irrelevant and no longer leads to phase separation.

Packed Bed↗

Laser Powder Bed Fusion Additive Manufacturing In-Process Monitoring and Optimization Using Thermionic Emission Detection

In this project, the emission of electrons during laser powder bed fusion additive manufacturing was identified and investigated to resolve the underlying dynamics driven by laser-material interactions. Laser powder bed fusion involves the selective laser melting of metal powder particles layer by layer which fuse together forming a larger 3D structure. Laser-based additive manufacturing approaches such as laser powder bed fusion hold the potential to revolutionize manufacturing of complex metal components in the aerospace, medical, and automotive industries. However, the difficulty in producing defect-free components by metal 3D printing is a major hurdle for widespread commercial adoption. This project resolved important dynamics in laser powder bed fusion including the identification of plasma formation mechanisms, transitions between laser-induced melting modes and stochastic precursors to defect formation. These findings were realized through implementation of electronic sensing diagnostics into an existing testbed system and harnessing capabilities developed for the time dependent analysis of laser powder bed fusion datasets. Importantly, the results advance our understanding of laser-material interactions and reveal that detection of thermionic emission can also resolve information critical to optimization of the laser powder bed fusion fabrication process. The findings are critical for advancing our fundamental understanding of the laser powder bed fusion process and can help assure the requisite fidelity of fabricated components.

36 MATERIALS SCIENCE↗

Effect of bed rest and exercise on body balance

A battery of 11 body balance tests was administered to 7 men before and after 14 days of bedrest. Seven men who had not undergone bed rest served as controls. During bed rest, each subject underwent daily either isotonic, isometric, or no leg exercise. The results showed that, for the bed-rested no exercise, isotonic exercise, and isometric exercise groups, 2 weeks of bed rest produces significant body balance decrements on 3, 4, and 5 of the 11 tests, respectively. Daily leg exercise did not prevent the debilitating effects of bed rest on body balance. After bed rest, balance skill was relearned rapidly so that in most tests, performance had reached prebed-rest levels by the third recovery day. These data suggest that balance impairment is not due to loss of muscular strength in the legs but, perhaps, to a bed-rest-related change in the neurally coded information to postural control centers.

Haines, R. F.↗

Reduction in peak oxygen uptake after prolonged bed rest

The hypothesis that the magnitude of the reduction in peak oxygen uptake (VO2) after bed rest is directly proportional to the level of pre-bed rest peak VO2 is tested. Complete pre and post-bed rest working capacity and body weight data were obtained from studies involving 24 men (19-24 years old) and 8 women (23-34 years old) who underwent bed rest for 14-20 days with no remedial treatments. Results of regression analyses of the present change in post-bed rest peak VO2 on pre-bed rest peak VO2 with 32 subjects show correlation coefficients of -0.03 (NS) for data expressed in 1/min and -0.17 for data expressed in ml/min-kg. In addition, significant correlations are found that support the hypothesis only when peak VO2 data are analyzed separately from studies that utilized the cycle ergometer, particularly with subjects in the supine position, as opposed to data obtained from treadmill peak VO2 tests. It is concluded that orthostatic factors, associated with the upright body position and relatively high levels of physical fitness from endurance training, appear to increase the variability of pre and particularly post-bed rest peak VO2 data, which would lead to rejection of the hypothesis.

Greenleaf, J. E.↗

Changes in body fluid compartments during a 28-day bed rest

Serial isotope measurements were used to obtain measurements of the body fluid responses of 10 22-29-year-old men during 28 d of simulated microgravity (bed rest). The subjects were maintained on a controlled metabolic diet for 7 d before the study, during 14 d of ambulatory control, 28 d of horizontal bed rest, and 14 d of ambulant recovery. Fluid compartments were measured on control days 1 and 9, bed rest days 2, 14, and 28, and recovery days 7 and 14. By day 2 of bed rest, plasma volume and extracellular volume (ECV) decreased significantly by an average 209 and 533 ml, respectively. Red cell volume and total body water (TBW) decreased more slowly, with average losses of 128 and 1316 ml, respectively, after 28 d of bed rest. Early in the bed rest, TBW loss was mostly from the ECV. Thereafter, the TBW deficit was derived from the intracellular compartment, which decreased an average of 838 ml after 28 d. These results suggest losses from all fluid compartments during bed rest, with no evidence of restoration of ECV after 1-2 weeks.

Fortney, Suzanne M.↗

The development of test beds to support the definition and evolution of the Space Station Freedom power system

Since the beginning of the Space Station Freedom Program (SSFP), the NASA Lewis Research Center (LeRC) and the Rocketdyne Division of Rockwell International have had extensive efforts underway to develop testbeds to support the definition of the detailed electrical power system design. Because of the extensive redirections that have taken place in the Space Station Freedom Program in the past several years, the test bed effort was forced to accommodate a large number of changes. A short history of these program changes and their impact on the LeRC test beds is presented to understand how the current test bed configuration has evolved. The current test objectives and the development approach for the current DC test bed are discussed. A description of the test bed configuration, along with its power and controller hardware and its software components, is presented. Next, the uses of the test bed during the mature design and verification phase of SSFP are examined. Finally, the uses of the test bed in the operation and evolution of the SSF are addressed.

Soeder, James F.↗

Orthostatic intolerance during a 13-day bed rest does not result from increased leg compliance

Increased leg compliance (LC) has been proposed as a mechanism for orthostatic intolerance after spaceflight or bed rest. Using venous occlusion plethysmography with mercury-in-Silastic strain gauge, we evaluated LC before, during, and after a 13-day head-down bed rest in 10 men. LC was measured by the relationship between the increased calf areas at thigh cuff occlusions of 20, 30, 50, 70, and 80 mmHg. Orthostatic tolerance was evaluated by a presyncopal-limited lower body negative pressure test before and after bed rest. The 10 subjects were divided into TOL (n= 5) and INT (n=5) groups for which the orthostatic tolerance was similar and lower after bed rest, respectively. For TOL (INT) before bed rest, calf area increases were 2.2 +/- 0.5 (SE) (1.3 +/- 0.4), 3.5 +/- 0.7 (2.3 +/- 0.5), 5.0 +/- 0.9 (3.5 +/- 0.6), 5.6 +/- 0.9 (4.4 +/- 0.6), and 6.4 +/- 1.1 (4.7 +/- 0.6) sq cm for thigh occlusion pressures of 20, 30, 50, 70, and 80 mmHg, respectively. Neither for INT nor for TOL were these results significantly changed by bed rest. These results suggest that other mechanisms than increased LC have to be taken into account to explain the decreased orthostatic tolerance induced by this 13-day bed rest.

Melchior, Francois M.↗

Concentration and Velocity Gradients in Fluidized Beds

In this work we focus on the height dependence of particle concentration, average velocity components, fluctuations in these velocities and, with the flow turned off, the sedimentation velocity. The latter quantities are measured using Particle Imaging Velocimetry (PIV). The PIV technique uses a 1-megapixel camera to capture two time-displaced images of particles in the bed. The depth of field of the imaging system is approximately 0.5 cm. The camera images a region with characteristic length of 2.6 cm for the small particles and 4.7 cm. for the large particles. The local direction of particle flow is determined by calculating the correlation function for sub-regions of 32 x 32 pixels. The velocity vector map is created from this correlation function using the time between images (we use 15 to 30 ms). The software is sensitive variations of 1/64th of a pixel. We produce velocity maps at various heights, each consisting of 3844 velocities. We break this map into three vertical zones for increased height information. The concentration profile is measured using an expanded (1 cm diameter) linearly polarized HeNe Laser incident on the fluidized bed. A COHU camera (gamma=1, AGC off) with a lens and a polarizer images the transmitted linearly polarized light to minimize the effects of multiply scattered light. The intensity profile (640 X 480 pixels) is well described by a Gaussian fit and the height of the Gaussian is used to characterize the concentration. This value is compared to the heights found for known concentrations. The sedimentation velocity is estimated using by imaging a region near the bottom of the bed and using PIV to measure the velocity as a function of time. With a nearly uniform concentration profile, the time can be converted to height information. The stable fluidized beds are made from large pseudo-monodisperse particles (silica spheres with radii (250-300) microns and (425-500) microns) dispersed in a glycerin/water mix. The Peclet number is sufficiently large that Brownian motion of the particles can be ignored and the Reynolds number sufficiently small that particle inertia is negligible. A packed particle bed is used to randomize and disperse the flowing fluid introduced by a peristaltic pump. The bed itself is a rectangular glass cell 8 cm wide (x), 0.8 cm deep and a height of 30.5 cm (z). The depth of field of the camera is approximately 0.5 cm so depth information is averaged. Over flow fluid is returned to the reservoir making a closed loop system. In these experiments the particles form a sediment approximately 5.7 cm high with the pump off and expand to 22 cm with the pump on. For the smaller particles the pump velocity is .5 millimeters per second and 1.1 millimeters per second for the large particles. At this concentration the bed has a very well defined top where particle concentration rapidly drops to zero.

McClymer, James P.↗

Effect of head-down-tilt bed rest and hypovolemia on dynamic regulation of heart rate and blood pressure

Adaptation to head-down-tilt bed rest leads to an apparent abnormality of baroreflex regulation of cardiac period. We hypothesized that this "deconditioning response" could primarily be a result of hypovolemia, rather than a unique adaptation of the autonomic nervous system to bed rest. To test this hypothesis, nine healthy subjects underwent 2 wk of -6 degrees head-down bed rest. One year later, five of these same subjects underwent acute hypovolemia with furosemide to produce the same reductions in plasma volume observed after bed rest. We took advantage of power spectral and transfer function analysis to examine the dynamic relationship between blood pressure (BP) and R-R interval. We found that 1) there were no significant differences between these two interventions with respect to changes in numerous cardiovascular indices, including cardiac filling pressures, arterial pressure, cardiac output, or stroke volume; 2) normalized high-frequency (0.15-0.25 Hz) power of R-R interval variability decreased significantly after both conditions, consistent with similar degrees of vagal withdrawal; 3) transfer function gain (BP to R-R interval), used as an index of arterial-cardiac baroreflex sensitivity, decreased significantly to a similar extent after both conditions in the high-frequency range; the gain also decreased similarly when expressed as BP to heart rate x stroke volume, which provides an index of the ability of the baroreflex to alter BP by modifying systemic flow; and 4) however, the low-frequency (0.05-0.15 Hz) power of systolic BP variability decreased after bed rest (-22%) compared with an increase (+155%) after acute hypovolemia, suggesting a differential response for the regulation of vascular resistance (interaction, P < 0.05). The similarity of changes in the reflex control of the circulation under both conditions is consistent with the hypothesis that reductions in plasma volume may be largely responsible for the observed changes in cardiac baroreflex control after bed rest. However, changes in vasomotor function associated with these two conditions may be different and may suggest a cardiovascular remodeling after bed rest.

Non-NASA Center↗

Cardiovascular Adaptations to Long Duration Head Down Tilt Bed Rest

Orthostatic hypotension is a recognized risk for crewmembers returning from space. Numerous cardiovascular mechanisms have been proposed to account for this problem including vascular and cardiac dysfunction. We studied arterial and cardiac function in 6-degree head-down tilt bed rest, which is the most widely accepted ground-based analog of spaceflight. Eleven subjects are included in this study (8 men and 3 women). Data analysis was limited to the first 49 days, and compared to pre-bed rest baseline data. Using ultrasound, data was collected on arterial diameters and flows at baseline and during reactive hyperemia and following administration of nitroglycerin. Echocardiography was used to acquire information regarding systolic and diastolic function as well as ventricular mass and diameter. Plasma volumes were significantly decreased by 7 days of bed rest and stayed down through 49 days. There were no differences in reactive hyperemic response in the arm at any time point. However, the hyperemic response in the leg was significantly increased at day 49. Arterial responses to nitroglycerin did not change over the duration of bed rest (day effect) in either the arm or leg, but there was a significant difference between the arm and the leg responses. There was a marked decrease in anterior tibial intimal-medial thickness at days 21, 35 and 49. Several cardiac functional parameters including IVRT, Mitral e-wave, ejection time, velocity of circumferential shortening and myocardial performance index were significantly changed following 49 days of bed rest. These data show that some cardiovascular measures change during bed rest, while others do not. Further study is needed to determine if these measures can provide any insight into the effects of bed rest, or spaceflight, on human cardiovascular performance.

Platts, Steven H.↗

Spool Valve for Switching Air Flows Between Two Beds

U.S. Patent 6,142,151 describes a dual-bed ventilation system for a space suit, with emphasis on a multiport spool valve that switches air flows between two chemical beds that adsorb carbon dioxide and water vapor. The valve is used to alternately make the air flow through one bed while exposing the other bed to the outer-space environment to regenerate that bed through vacuum desorption of CO2 and H2O. Oxygen flowing from a supply tank is routed through a pair of periodically switched solenoid valves to drive the spool valve in a reciprocating motion. The spool valve equalizes the pressures of air in the beds and the volumes of air flowing into and out of the beds during the alternations between the adsorption and desorption phases, in such a manner that the volume of air that must be vented to outer space is half of what it would be in the absence of pressure equalization. Oxygen that has been used to actuate the spool valve in its reciprocating motion is released into the ventilation loop to replenish air lost to vacuum during the previous desorption phase of the operating cycle.

Dean, W. Clark↗

Gradient Compression Stockings may Prevent Recovery after Bed Rest Deconditioning

Introduction: Astronauts continue to wear a compression garment during and immediately after landing to prevent orthostatic intolerance (OI). We recently developed a custom-fitted, 3-piece garment that consists of thigh-high stockings with biker-style shorts that provides continuous, gradient compression: 55 mmHg at the ankle that decreases to approximately 20 mmHg at the top of the leg and 15 mmHg over the abdomen. This garment has been shown to be effective in preventing symptoms of OI during a short stand test after Space Shuttle missions, but symptoms may persist for several days after a long-duration mission in some astronauts. The purpose of this study was to confirm the effectiveness of wearing these elastic, gradient compression garments during orthostatic testing after 2 weeks of 6 degree head-down tilt bed rest as a model of spaceflight and to determine whether they would impact recovery after bed rest. Methods: Eight (5 treatment, 3 control) of 16 subjects have completed this study to-date. All subjects wore the 3-piece garment from waking until tilt testing (~3 h) as a simulation of the timeline for astronauts on landing day (BR+0). Control subjects removed the garment after the tilt test. Treatment subjects wore the garment for the remainder of the day and wore lower compression thigh-high only garments on the day after bed rest (BR+1). Blood pressure, heart rate, and stroke volume responses to a 15-min 80 degree head-up tilt test were determined before 2 weeks of 6 degree head-down tilt, and on BR+0 and BR+1. Plasma volume (PV) was measured before each of these test sessions. Data are mean SE. Results: Compression garments prevented signs of OI on BR+0; all subjects in both groups completed the full 15-min test. Heart rate responses to tilt were lower on BR+0 than all other test days. Control subjects demonstrated a marginal PV decrease after bed rest, but showed typical recovery the day after bed rest (BR+0: 2.32 plus or minus 0.15 L to BR+1: 2.79 plus or minus 0.15 L). Treatment subjects did not recover PV the day after bed rest (BR+0: 2.61 plus or minus 0.23 L to BR+1: 2.61 plus or minus 0.23 L). Conclusion: Abdomen-high compression garments, which are effective in preventing post-bed rest orthostatic intolerance, may slow recovery of PV. Modified garments with reduced compression may be necessary to prevent prolonging recovery.

Stenger, Michael B.↗

Performance Evaluation of the ISS Water Processor Multifiltration Beds

The ISS Water Processor Assembly (WPA) produces potable water from a waste stream containing humidity condensate and urine distillate. The primary treatment process is achieved in the Multifiltration Bed, which includes adsorbent media and ion exchange resin for the removal of dissolved organic and inorganic contaminants. The first Multifiltration Bed was replaced on ISS in July 2010 after initial indication of inorganic breakthrough. This bed was returned to ground in July 2011 for an engineering investigation. The water resident in the bed was analyzed for various parameters to evaluate adsorbent loading, performance of the ion exchange resin, microbial activity, and generation of leachates from the ion exchange resin. Portions of the adsorbent media and ion exchange resin were sampled and subsequently desorbed to identify the primary contaminants removed at various points in the bed. In addition, an unused Multifiltration Bed was evaluated after two years in storage to assess the generation of leachates during storage. This assessment was performed to evaluate the possibility that these leachates are impacting performance of the Catalytic Reactor located downstream of the Multifiltration Bed. The results of these investigations and implications to the operation of the WPA on ISS are documented in this paper.

Bowman, Elizabeth M.↗