Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

NUMERICAL STUDY OF THE VISHNIAC INSTABILITY IN SUPERNOVA REMNANTS

The Vishniac instability is thought to explain the complex structure of radiative supernova remnants in their Pressure-Driven Thin Shell (PDTS) phase after a blast wave (BW) has propagated from a central explosion. In this paper, the propagation of the BW and the evolution of the PDTS stage are studied numerically with the two-dimensional (2D) code HYDRO-MUSCL for a finite-thickness shell expanding in the interstellar medium (ISM). Special attention is paid to the adiabatic index, {gamma}, and three distinct values are taken for the cavity ({gamma}{sub 1}), the shell ({gamma}{sub 2}), and the ISM ({gamma}{sub 3}) with the condition {gamma}{sub 2} < {gamma}{sub 1}, {gamma}{sub 3}. This low value of {gamma}{sub 2} accounts for the high density in the shell achieved by a strong radiative cooling. Once the spherical background flow is obtained, the evolution of a 2D-axisymmetric perturbation is computed from the linear to the nonlinear regime. The overstable mechanism, previously demonstrated theoretically by E. T. Vishniac in 1983, is recovered numerically in the linear stage and is expected to produce and enhance anisotropies and clumps on the shock front, leading to the disruption of the shell in the nonlinear phase. The period of the increasing oscillations and the growth rate of the instability are derived from several points of view (the position of the perturbed shock front, mass fluxes along the shell, and density maps), and the most unstable mode differing from the value given by Vishniac is computed. In addition, the influence of several parameters (the Mach number, amplitude and wavelength of the perturbation, and adiabatic index) is examined and for wavelengths that are large enough compared to the shell thickness, the same conclusion arises: in the late stage of the evolution of the radiative supernova remnant, the instability is dampened and the angular initial deformation of the shock front is smoothed while the mass density becomes uniform with the angle. As a result, our model shows that the supernova remnant returns to a stable evolution and the Vishniac instability does not lead to the fragmentation of the shock as predicted by the theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon Source Capabilities of the Jefferson Lab FEL

Jefferson Lab operates a superconducting energy recovered linac which is operated with CW RF and which powers oscillator-based IR and UV Free Electron Lasers (FELs) with diffraction limited sub-picosecond pulses with >10{sup 13} photons per pulse (1.0%BW) at pulse repetition frequencies up to 75 MHz. Useful harmonics extend into the vacuum ultraviolet (VUV). Based on FEL model calculations validated using this facility, we have designed both an oscillator-based VUV-FEL that would produce 6 10{sup12} coherent (0.5% BW) 100 eV photons per pulse at multi-MHz repetition rates in the fundamental, and a dual FEL configuration that would allow simultaneous lasing lasing at THz and UV wavelengths. The VUV-FEL would utilize a novel high gain, low Q cavity, while the THz source would be an FEL oscillator with a short wiggler providing diffraction limited pulses with pulse energy exceeding 50 microJoules. The THz source would use the exhaust beam from a UVFEL. Such multiphoton capabilities would provide unique opportunities for out of equilibrium dynamical studies at time-scales down to 50 fs. The fully coherent nature of all these sources results in peak and average brightness values that are many orders of magnitude higher than storage rings. We acknowledge support from the Commonwealth of Virginia. Jefferson Lab is supported by the U.S. DOE under Contract No. DE-AC05-84-ER40150.

43 PARTICLE ACCELERATORS↗

Free-electron laser inverse-Compton interaction x-ray source

Free-electron lasers (FEL) and synchrotron sources of high brilliance x-rays have been confirmed to be of tremendous value in basic and applied research. Inverse-Compton sources (ICS) can achieve brilliance matching the requirements of many applications pioneered at those FEL and synchrotron facilities—including phase contrast imaging, macromolecular x-ray crystallography, and x-ray microscopy—but with size, cost, and complexity compatible with a small laboratory. The free-electron laser inverse-Compton interaction compact x-ray source at the University of Hawaii at Manoa is a unique approach to an ICS which employs an FEL as the laser source. We have measured a total average flux of 3.0 × 10 5 photons / second with an average brilliance of 2.0 × 10 7 photons / s mm 2 mrad 2 0.1% of bandwidth (BW) with a peak energy of 10.9 keV from the source. While these results are modest in comparison to the standards set by other IC sources, upgrades to the system have the potential to increase the total average flux to 9.2 × 10 11 photons / second with an average brilliance of 1.9 × 10 12 photons / s mm 2 mrad 2 0.1% BW: comparing more favorably to other sources. We discuss the scientific program, the progress made in design and development, and the achievements of the source to date. We also outline future upgrades and integration needed to yield an enabling source for emerging high brilliance x-ray applications.

43 PARTICLE ACCELERATORS↗

Study of the lineshape of the χ c1 (3872) state

A study of the lineshape of the χ c1 (3872) state is made using a data sample corresponding to an integrated luminosity of 3 fb –1 collected in pp collisions at center-of-mass energies of 7 and 8 TeV with the LHCb detector. Candidate χ c1 (3872) and ψ(2S) mesons from b-hadron decays are selected in the J/ψπ + π – decay mode. Describing the lineshape with a Breit-Wigner function, the mass splitting between the χ c1 (3872) and ψ(2S) states, Δm, and the width of the χ c1 (3872) state, Γ BW , are determined to be Δm=185.598 ± 0.067 ± 0.068 MeV, Γ BW = 1.39 ± 0.24 ± 0.10 MeV, where the first uncertainty is statistical and the second systematic. Using a Flatté-inspired model, the mode and full width at half maximum of the lineshape are determined to be mode = 3871.69+0.00+0.05 – 0.04–0.13 MeV, FWHM=0.22 +0.07+0.11–0.06–0.13 MeV. An investigation of the analytic structure of the Flatté amplitude reveals a pole structure, which is compatible with a quasibound D 0 D¯ *0 state but a quasivirtual state is still allowed at the level of 2 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of the lineshape of X ( 3872 ) using B decays to D 0 D ¯ * 0 K

We present a study of the X⁡(3872) lineshape in the decay B →X(3872)⁢K →D 0 $\overline{D}$ *0 ⁢K using a data sample of 772 ×10 6 B$\overline{B}$ pairs collected at the Y⁡(4⁢S) resonance with the Belle detector at the KEKB asymmetric-energy e +⁢ e - collider. The peak near the threshold in the D 0 $\overline{D}$ *0 invariant mass spectrum is fitted using a relativistic Breit-Wigner lineshape. We determine the mass and width parameters to be m BW =3873.7⁢1$^{+0.56}_{-0.50⁢}$(stat) ±0.13⁢(syst) MeV/c 2 and Γ BW =5.2$^{+2.2}_{-1.5}$⁢(stat) ±0.4⁢(syst) MeV, respectively. The branching fraction is found to be $\mathscr{B}$⁡(B + → X⁡(3872)⁢K + ) × $\mathscr{B}$⁡(X⁡(3872) → D 0 $\overline{D}$ *0 ) = (0.9⁢7$^{+0.21}_{-0.18}$⁢(stat) ± 0.10⁢(syst)) ×10 -4 . The signal from B 0 decays is observed for the first time with 5.2σ significance, and the ratio of branching fractions between charged and neutral B decays is measured to be $\mathscr{B}$(B 0 → X⁡(3872)⁢K 0 )/$\mathscr{B}$⁡(B + →X⁡(3872)⁢K + ) =1.34$^{+0.47}_{-0.40}$⁢(stat) $^{+0.10}_{-0.12}$⁢(syst). The peak is also studied using a Flatté lineshape. We determine the lower limit on the D 0 $\overline{D}$ * coupling constant g to be 0.075 at 95% credibility in the parameter region where the ratio of g to the mass difference from the D 0 $\overline{D}$ *0 threshold is equal to -15.11 GeV -1 , as measured by LHCb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of the D+ --> K- pi+ e+ nu_e decay channel

Using 347.5 fb{sup -1} of data recorded by the BABAR detector at the PEP-II electron-positron collider, 244 x 10{sup 3} signal events for the D{sup +} {yields} K{sup -}{pi}{sup +}e{sup +}{nu}{sub e} decay channel are analyzed. This decay mode is dominated by the {bar K}*(892){sup 0} contribution. We determine the {bar K}*(892){sup 0} parameters: m{sub K*(892){sup 0}} = (895.4{+-}0.2{+-}0.2) MeV/c{sup 2}, {Lambda}{sub K*(892){sup 0}}{sup 0} = (46.5{+-}0.3{+-}0.2) MeV/c{sup 2} and the Blatt-Weisskopf parameter r{sub BW} = 2.1{+-}0.5{+-}0.5 (GeV/c){sup -1} where the first uncertainty comes from statistics and the second from systematic uncertainties. We also measure the parameters defining the corresponding hadronic form factors at q{sup 2} = 0 (r{sub V} = V(0)/A{sub 1}(0) = 1.463{+-}0.017{+-}0.031, r{sup 2} = A{sub 2}(0)/A{sub 1}(0) = 0.801{+-}0.020{+-}0.020) and the value of the axial-vector pole mass parameterizing the q{sup 2} variation of A{sub 1} and A{sub 2}: m{sub A} = (2.63{+-}0.10{+-}0.13) GeV/c{sup 2}. The S-wave fraction is equal to (5.79{+-}0.16{+-}0.15)%. Other signal components correspond to fractions below 1%. Using the D{sup +} {yields} K{sup -}{pi}{sup +}{pi}{sup +} channel as a normalization, we measure the D{sup +} semileptonic branching fraction: {Beta}(D{sup +} {yields} K{sup -}{pi}{sup +}e{sup +}{nu}{sub e}) = (4.00 {+-} 0.03 {+-} 0.04 {+-} 0.09) x 10{sup -2} where the third uncertainty comes from external inputs. We then obtain the value of the hadronic form factor A{sub 1} at q{sup 2} = 0: A{sub 1}(0) = 0.6200 {+-} 0.0056 {+-} 0.0065 {+-} 0.0071. Fixing the P-wave parameters we measure the phase of the S-wave for several values of the K{pi} mass. These results confirm those obtained with K{pi} production at small momentum transfer in fixed target experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark decay of the top quark

We suggest top quark decays as a venue to search for light dark force carriers. Top quark is the heaviest particle in the standard model whose decays are relatively poorly measured, allowing sufficient room for exotic decay modes from new physics. A very light (GeV scale) dark gauge boson (Z') is a recently highlighted hypothetical particle that can address some astrophysical anomalies as well as the 3.6 σ deviation in the muon g-2 measurement. We present and study a possible scenario that top quark decays as t → b W + Z's. This is the same as the dominant top quark decay (t → b W) accompanied by one or multiple dark force carriers. The Z' can be easily boosted, and it can decay into highly collimated leptons (lepton-jet) with large branching ratio. In addition, we discuss the implications for the Large Hadron Collider experiments including the analysis based on the lepton-jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 128-Tap Highly Tunable CMOS IF Finite Impulse Response Filter for Pulsed Radar Applications

A configurable-bandwidth (BW) filter is presented in this paper for pulsed radar applications. Also, to eliminate dispersion effects in the received waveform, a finite impulse response (FIR) topology is proposed, which has a measured standard deviation of an in-band group delay of 11 ns that is primarily dominated by the inherent, fully predictable delay introduced by the sample-and-hold. The filter operates at an IF of 20 MHz, and is tunable in BW from 1.5 to 15 MHz, which makes it optimal to be used with varying pulse widths in the radar. Employing a total of 128 taps, the FIR filter provides greater than 50-dB sharp attenuation in the stopband in order to minimize all out-of-band noise in the low signal-to-noise received radar signal. Fabricated in a 0.18-μm silicon on insulator CMOS process, the proposed filter consumes approximately 3.5 mW/tap with a 1.8-V supply. Finally, a 20-MHz two-tone measurement with 200-kHz tone separation shows IIP3 greater than 8.5 dBm.

42 ENGINEERING↗

A dual-bandwidth multilayer monochromator system

This paper reports on a planned upgrade to the capabilities of the Illinois Institute of Technology’s BioCAT undulator beamline in an effort to increase the photon flux 10 to 100-fold. This is accomplished by the addition of a double multilayer monochromator (MLM) system complementing the existing cryogenically-cooled double crystal silicon monochromator system. The water-cooled MLMs are designed and fabricated with each having two coated stripes to deliver a 12 keV undulator beam with either 1.0% or 0.5% energy bandwidths (BW). To simplify the mechanical design and operation of the MLM system, the two coatings have been designed with the same period thickness so that the BW selection is accomplished (at the same Bragg angle) by a mere horizontal translation of the MLMs. The challenge has been to find a pair of coatings that provide the desired BWs with high reflectivity at the same incident angle. This was achieved using MoSi2/B4C and Mo/MoSi2/B4C/MoS2 multilayers at an angle of 1.194°. The bandwidths and reflectivities attained are 0.52 and 83.33% for the former and 0.86 and 75.9% for the latter. Details are provided.

X-ray optics, multilayer, coating, tuning, reflect↗

TU-C-12A-01: Measurement of Skeletal Muscle Lipids in Type 2 Diabetes Using in Vivo Proton MR Spectroscopy

Purpose: To quantify and compare the intramyocellular (IMCL), extramyocellular (EMCL) lipids and total fat fraction in human vastus lateralis (VL) muscle between lean controls and type 2 diabetic (T2DM) subjects using long echo time in vivo proton MR spectroscopy ({sup 1}H-MRS) Methods: {sup 1}H-MRS single voxel (15 × 15 × 15 mm{sup 3}) stimulated acquisition mode (STEAM) was performed in right vastus lateralis m. on 10 lean controls (age: 28.3±3.94 yrs, BMI: 24.25±3.20 kg/m{sup 2}) and 7 type 2 diabetic (age: 54.28±6.42 yrs, BMI: 31.34±3.13 kg/m{sup 2}) subjects with Siemens 3T MRI and four-channel flex coil. Unsuppressed water spectra (NSA = 16) with TR/TE = 3000/30 msec, TM = 10 msec, BW = 2000 Hz, and water-suppressed spectra (NSA = 128) with TR/TE = 3000/270 msec, TM = 10 msec, and fixed water suppression BW = 50 Hz were acquired. Spectral intensity ratios of IMCL-CH{sub 2}, EMCL-CH{sub 2} and total lipid (IMCL {sub +} EMCL) with unsuppressed water signal (W) were converted into absolute concentrations expressed in mmol/kg. Fat fraction (100 × F/(W+F)) was calculated, where F includes the signal intensities of IMCL and EMCL methylene (CH{sub 2})n, peaks only. Results: Comparison of IMCL (controls: 11.70 ± 6.7, T2DM: 21.74 ± 10.2, p ≤ 0.01), EMCL (controls: 22.89 ± 18.42, T2DM: 77.21 ± 33.4, p ≤ 0.001) and total lipid (64.35 mmol/kg less in controls, p ≤ 0.001) showed statistical significance using two-tailed student t-test. Fat fraction (%) exhibited considerable inter-individual variability for controls (3.14 ± 2.09; range: 1.34 - 7.04) and T2DM (9.34 ± 2.88; range: 4.15 - 13.67) and deemed significant (p ≤ 0.05 Conclusion: Single voxel STEAM {sup 1}H-MRS at long TE provides a robust non-invasive method for characterizing lipids within localized muscle regions, with well-resolved IMCL/EMCL peak separation. Regional lipid estimate and fat fraction in VL m. was significantly different in T2DM compared to lean controls. American Heart Association Southwest Affiliate Pre-doctoral Fellowship.

60 APPLIED LIFE SCIENCES↗

Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction

Purpose: To develop ultralow dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultralow doses (10–35 mA s). CT quantitation: noise, low-contrast resolution, and CT numbers for 11 tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% volume computed tomography dose index (0.39/3.64; mGy) from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUV{sub bw}) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative dose reduction and noise control. Results: CT numbers were constant to within 10% from the nondose reduced CTAC image for 90% dose reduction. No change in SUV{sub bw}, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols was found down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62% and 86% (3.2/8.3–0.9/6.2). Noise magnitude in dose-reduced patient images increased but was not statistically different from predose-reduced patient images. Conclusions: Using ASiR allowed for aggressive reduction in CT dose with no change in PET reconstructed images while maintaining sufficient image quality for colocalization of hybrid CT anatomy and PET radioisotope uptake.

60 APPLIED LIFE SCIENCES↗

Genomic Signatures of Strain Selection and Enhancement in Bacillus atrophaeus var. globigii , a Historical Biowarfare Simulant

Despite the decades-long use of Bacillus atrophaeus var. globigii (BG) as a simulant for biological warfare (BW) agents, knowledge of its genome composition is limited. Furthermore, the ability to differentiate signatures of deliberate adaptation and selection from natural variation is lacking for most bacterial agents. We characterized a lineage of BGwith a long history of use as a simulant for BW operations, focusing on classical bacteriological markers, metabolic profiling and whole-genome shotgun sequencing (WGS). Archival strains and two ‘‘present day’’ type strains were compared to simulant strains on different laboratory media. Several of the samples produced multiple colony morphotypes that differed from that of an archival isolate. To trace the microevolutionary history of these isolates, we obtained WGS data for several archival and present-day strains and morphotypes. Bacillus-wide phylogenetic analysis identified B. subtilis as the nearest neighbor to B. atrophaeus. The genome of B. atrophaeus is, on average, 86% identical to B. subtilis on the nucleotide level. WGS of variants revealed that several strains were mixed but highly related populations and uncovered a progressive accumulation of mutations among the ‘‘military’’ isolates. Metabolic profiling and microscopic examination of bacterial cultures revealed enhanced growth of ‘‘military’’ isolates on lactate-containing media, and showed that the ‘‘military’’ strains exhibited a hypersporulating phenotype. Conclusions: Our analysis revealed the genomic and phenotypic signatures of strain adaptation and deliberate selection for traits that were desirable in a simulant organism. Together, these results demonstrate the power of whole-genome and modern systems-level approaches to characterize microbial lineages to develop and validate forensic markers for strain discrimination and reveal signatures of deliberate adaptation.

59 BASIC BIOLOGICAL SCIENCES↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSR J1301+0833: a kinematic study of a black-widow pulsar

We have obtained spectroscopic measurements of the P {sub s} = 1.8 ms, P {sub B} = 6.5 hr black-widow (BW) pulsar PSR J1301+0833 as part of a program to investigate optical companions of wind-shrouded pulsars. The derived radial-velocity amplitude (259±4 km s{sup −1}) and inclination (i≈52{sup ∘}) imply a neutron star mass M{sub p}=1.74{sub −0.17}{sup +0.20} M{sub ⊙}, smaller (for similar fit assumptions) than that of the well-studied original BW pulsar PSR J1959+2048, which shares similar values of P {sub s} and P {sub B}. This fit, which assumes d≈1 kpc, indicates a small heated region on the (anomalously faint) companion. With a free distance and full surface heating the best fit is statistically acceptable, but the large inferred d=4.7±0.3 kpc is inconsistent with the observed pulsar proper motion. Improved photometry and heating models will be needed to refine these measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

The 3-dimensional radio mapping experiment /SBH/ on ISEE-C

The SBH experiment on ISEE-C will provide maps of the large scale structure of the interplanetary magnetic field from ten solar radii altitude to the earth orbit, in and out of the ecliptic. The SBH instrument will track type III solar radio bursts at 24 frequencies in the range 30 kHz-2 MHz thus providing the positions of 24 points along the line of force which guides the electrons producing the radio radiation. The antennas are two dipoles: one (90 m long) in the spin plane, the other (15 m long) along the spin axis. The receiver was designed for high sensitivity (0.3 microV in 3 kHz BW), high intermodulation rejection (80 dB/1 microV input for order 2 products), large dynamic range (70 dB), high selectivity (-30-dB response 6.5 kHz away from the center frequency of 10.7 MHz for the 3 kHz BW channels), and high reliability (expected orbital life: 3 years).

Knoll, R.↗

30/20 GHz communications satellite multibeam antenna

A 20 GHz downlink satellite antenna design is described. The aperture simultaneously radiates 18 fixed, 0.3 deg width pencil beams directed at 18 cities distributed over CONUS for Trunking Service. All beams use the same trunk frequency allocation for 18 reuses of the band. The same aperture also radiates six additional 0.3 deg spot beams for Customer Premises Service (CPS) for TDMA beam hopping operation to small terminals anywhere in CONUS. Each CPS beam scans one sector of CONUS and all six beams are frequency reused in a CPS band. Offset dual reflector optics are used with a feed array and multiport beam forming network (BFN). For so many frequency reuses, sidelobes per beam must be 30 to 40 dB down over CONUS. Novel dual reflector optics were devised with shaped surfaces providing low aberrations for all beam positions over CONUS (+ or - 12 BW by + or - 5 BW). Scan loss under 1 dB is calculated with nearly constant sidelobes. For each beam position, a 7-element cluster of feeds is activated in the feed array with coefficients adjusted by the BFN to maintain low sidelobes and thus high beam isolation for frequency reuse.

Scott, W. G.↗

Array feed synthesis for correction of reflector distortion and Vernier Beamsteering

An algorithmic procedure for the synthesis of planar array feeds for paraboloidal reflectors is described which simultaneously provides electronic correction of systematic reflector surface distortions as well as a Vernier electronic beamsteering capability. Simple rules of thumb for the optimum choice of planar array feed configuration (i.e., number and type of elements) are derived from a parametric study made using the synthesis procedure. A number of f/D ratios and distortion models were examined that are typical of large paraboloidal reflectors. Numerical results are presented showing that, for the range of distortion models considered, good on-axis gain restoration can be achieved with as few as seven elements. For beamsteering to +/- 1 beamwidth (BW), 19 elements are required. For arrays with either 7 or 19 elements, the results indicate that the use of high-aperture-efficiency elements (e.g., disk-on-rod and short backfire) in the array yields higher system gain than can be obtained with elements having lower aperture efficiency (e.g., open-ended waveguides). With 37 elements, excellent gain and beamsteering performance to +/- 1.5 BW are obtained independent of the assumed effective aperture of the array element. An approximate expression is derived for the focal-plane field distribution of the distorted reflector. Contour plots of the focal-plane fields are also presented for various distortion and beam scan angle cases. The results obtained show the effectiveness of the array feed approach.

Blank, S. J.↗