Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BRASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Roughness and surface material effects on nucleate boiling heat transfer from cylindrical surfaces to refrigerants R-134a and R-123

This paper presents results of an experimental investigation carried out to determine the effects of the surface roughness of different materials on nucleate boiling heat transfer of refrigerants R-134a and R-123. Experiments have been performed over cylindrical surfaces of copper, brass and stainless steel. Surfaces have been treated by different methods in order to obtain an average roughness, Ra, varying from 0.03 {mu}m to 10.5 {mu}m. Boiling curves at different reduced pressures have been raised as part of the investigation. The obtained results have shown significant effects of the surface material, with brass being the best performing and stainless steel the worst. Polished surfaces seem to present slightly better performance than the sand paper roughened. Boiling on very rough surfaces presents a peculiar behavior characterized by good thermal performance at low heat fluxes, the performance deteriorating at high heat fluxes with respect to smoother surfaces. (author)

42 ENGINEERING↗

Grain structure, texture and mechanical property evolution of automotive aluminium sheet during high power ultrasonic welding

High power ultrasonic spot welding (HPUSW) is a joining technique which is performed within less than a second and provides a more energy-efficient alternative to friction stir spot welding (FSSW), which is considered a longer cycle manufacturing process for joining automotive alloys. To date, only a few reports exist on the deformation mechanisms that take place during high power ultrasonic spot welding. In this work, dynamic recrystallization and grain growth were examined using electron backscatter diffraction (EBSD). HPUSW causes extensive deformation within the weld zone where the temperature increases to 440 °C. An ultra-fine grain structure was observed in a thin band of flat weld interface within a short welding time of 0.10 s. With increasing welding time the interface was displaced and ‘folds’ or ‘crests’ appeared together with shear bands. The weld interface progressively changed from flat to sinusoidal and eventually to a convoluted wave-like pattern when the tool fully penetrated the workpiece, having a wavelength of ~ 1 mm after 0.40 s. Finally, the microstructure and texture varied significantly depending on the location within the weld. Although the texture near the weld interface was relatively weak, a shift was observed with increasing welding time from an initially Cube-dominated texture to one where the typical β-fibre Brass component prevailed. - Highlights: •Lap shear strength of ~2.9 kN was achieved in 0.30 sec welding time. •Temperature approached 440 °C along the weld centreline for the highest welding time. •The texture near the teeth was dominated by Brass, P and S components at optimum condition. •The weld interface showed typical β-fibre deformation texture at optimum condition.

36 MATERIALS SCIENCE↗

Commissioning a Miniature Multileaf Collimator for Small Field Radiotherapy

The aim of this study was to determine dosimetric data for the Siemens ModuLeaf miniature multileaf collimator. Acquiring accurate data for small fields requires careful evaluation of different measurement techniques and dosimeters. Output factors were measured using several different detectors. Comparing these results demonstrated the relative under-response of the devices as the field size approaches the active area of the detector. Measurements obtained with a diamond detector, radiographic film, 0.125 cm{sup 3} cylindrical and advanced Markus ionization chambers agreed (within 0.7%) down to a field size of 2 x 2 cm. For smaller field sizes, only the diamond detector and the film agreed within their relative uncertainties. Head scatter factors were measured in brass and Perspex miniphantoms using the cylindrical chamber positioned at the isocenter, and in the Perspex miniphantom at extended distances. For field sizes of less than 3 x 3 cm, only the measurements with the brass miniphantom at the isocenter and the Perspex miniphantom at extended distances agreed (within 0.8%). The effect on the miniphantom measurements of using a low scatter support stand was also quantified. Beam profiles were measured using radiographic film. An unexpected artifact was found in these images because of increased backscatter from white lines inscribed and painted on the phantom. Percentage depth doses (PDDs) measured with and without the ModuLeaf attached agreed for all field sizes down to 3 x 3 cm. Below this field size, tissue maximum ratios (TMRs) were measured using an advanced Markus chamber. The 3 x 3 cm ModuLeaf TMR data agreed with the non-ModuLeaf PDD data within their relative uncertainties. This study investigated the use of several different measurement methods from which accurate dosimetric parameters can be obtained without the need to acquire specialist detectors.

61 RADIATION PROTECTION AND DOSIMETRY↗

EXAMINATION OF THE OXIDATION PROTECTION OF ZINC COATINGS FORMED ON COPPER ALLOYS AND STEEL SUBSTRATES

The exposure of metallic components at aggressive high temperature environments, usually limit their usage at similar application because they suffer from severe oxidation attack. Copper alloys are used in a wide range of high-quality indoor and outdoor applications, statue parts, art hardware, high strength and high thermal conductivity applications. On the other hand, steel is commonly used as mechanical part of industrial set outs or in the construction sector due to its high mechanical properties. The aim of the present work is the examination of the oxidation resistance of pack cementation zinc coatings deposited on copper, leaded brass and steel substrates at elevated temperature conditions. Furthermore, an effort made to make a long-term evaluation of the coated samples durability. The oxidation results showed that bare substrates appear to have undergone severe damage comparing with the coated ones. Furthermore, the mass gain of the uncoated samples was higher than this of the zinc covered ones. Particularly zinc coated brass was found to be more resistant to oxidation conditions in which it was exposed as it has the lower mass gain as compared to the bare substrates and zinc coated copper. Zinc coated steel was also proved to be more resistive than the uncoated steel.

36 MATERIALS SCIENCE↗

Monte Carlo Simulation of the Conversion X-Rays from the Electron Beam of PFMA-3

PFMA-3, a dense Plasma Focus device, is being optimized as an X-ray generator. X-rays are obtained from the conversion of the electron beam emitted in the backward direction and driven to impinge on a 50 {mu}m brass foil. Monte Carlo simulations of the X-ray emission have been conducted with MCNPX. The electron spectrum had been determined experimentally and is used in the present work as input to the simulations. Dose to the brass foil has been determined both from simulations and from measurements with a thermographic camera, and the two results are found in excellent agreement, thus validating further the electron spectrum assumed as well as the simulation set-up. X-ray emission has been predicted both from bremsstrahlung and from characteristic lines. The spectrum has been found to be comprised of two components of which the one at higher energy, 30 divide 70 keV, is most useful for IORT applications. The results are necessary to estimate penetration in and dose to Standard Human Tissue.

43 PARTICLE ACCELERATORS↗

Study And Comparison Of Silver Mirrors Deposited On Different Substrates By Electron-Beam Gun Method

Choosing the right substrate is one of the important factors for improving quality parameters of thin films such as adhesion between layers and substrates. The selected substrate should have proper physical and chemical compatibility with deposited thin film. In this paper, we have been investigated four different types of high reflective laser mirrors that were produced in similar conditions on four different kinds of substrates including copper, stainless steel, brass, and nickel. We used electron-beam gun method for deposition of silver layers. At the end we compared theoretical results with practical results that were yielded by laser damage threshold test. It was shown that brass is the best choice for silver metal mirrors as a substrate.

36 MATERIALS SCIENCE↗

Dynamics of femto- and nanosecond laser ablation plumes investigated using optical emission spectroscopy

We investigated the spatial and temporal evolution of temperature and electron density associated with femto- and nanosecond laser-produced plasmas (LPP) from brass under similar laser fluence conditions. For producing plasmas, brass targets were ablated in vacuum employing pulses either from a Ti:Sapphire ultrafast laser (40 fs, 800 nm) or from a Nd:YAG laser (6 ns, 1064 nm). Optical emission spectroscopy is used to infer the density and temperature of the plasmas. The electron density (n{sub e}) was estimated using Stark broadened profiles of isolated lines while the excitation temperature (T{sub exc}) was estimated using the Boltzmann plot method. At similar fluence levels, continuum and ion emission are dominant in ns LPP at early times (<50 ns) followed by atomic emission, while the fs LPP provided an atomic plume throughout its visible emission lifetime. Though both ns and fs laser-plasmas showed similar temperatures ({approx}1 eV), the fs LPP is found to be significantly denser at shorter distances from the target surface as well as at early phases of its evolution compared to ns LPP. Moreover, the spatial extension of the plume emission in the visible region along the target normal is larger for fs LPP in comparison with ns LPP.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quasi-discrete particle motion in an externally imposed, ordered structure in a dusty plasma at high magnetic field

Dusty plasmas have been studied in argon, radio frequency (rf) glow discharge plasmas at magnetic fields up to 2.5 T where the electrons and ions are strongly magnetized. Plasmas are generated between two parallel plate electrodes where the lower, powered electrode is solid and the upper electrode supports a dual mesh consisting of #24 brass and #30 aluminum wire cloth. In this experiment, we study the formation of imposed ordered structures and particle dynamics as a function of magnetic field. Through observations of trapped particles and the quasi-discrete (i.e., “hopping”) motion of particles between the trapping locations, it is possible to make a preliminary estimate of the potential structure that confines the particles to a grid structure in the plasma. In conclusion, this information is used to gain insight into the formation of the imposed grid pattern of the dust particles in the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Asymmetric acoustic transmission in multiple frequency bands

We report both experimentally and numerically that the multi-band device of the asymmetric acoustic transmission is realized by placing two periodic gratings with different periods on both sides of two brass plates immersed in water. The asymmetric acoustic transmission can exist in four frequency bands below 1500 kHz, which arises from the interaction between various diffractions from the two gratings and Lamb modes in the brass plates immersed in water. The results indicate that the device has the advantages of multiple band, broader bandwidth, and simpler structure. Our finding should have great potential applications in ultrasonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of electrical breakdown properties of deionized water and heavy water under pulsed power conditions

A comparative study of electrical breakdown properties of deionized water (H{sub 2}O) and heavy water (D{sub 2}O) is presented with two different electrode materials (stainless steel (SS) and brass) and polarity (positive and negative) combinations. The pulsed (∼a few tens of nanoseconds) discharges are conducted by applying high voltage (∼a few hundred kV) pulse between two hemisphere electrodes of the same material, spaced 3 mm apart, at room temperature (∼26-28 °C) with the help of Tesla based pulse generator. It is observed that breakdown occurred in heavy water at lesser voltage and in short duration compared to deionized water irrespective of the electrode material and applied voltage polarity chosen. SS electrodes are seen to perform better in terms of the voltage withstanding capacity of the liquid dielectric as compared to brass electrodes. Further, discharges with negative polarity are found to give slightly enhanced discharge breakdown voltage when compared with those with positive polarity. The observations corroborate well with conductivity measurements carried out on original and post-treated liquid samples. An interpretation of the observations is attempted using Fourier transform infrared measurements on original and post-treated liquids as well as in situ emission spectra studies. A yet another important observation from the emission spectra has been that even short (nanosecond) duration discharges result in the formation of a considerable amount of ions injected into the liquid from the electrodes in a similar manner as reported for long (microseconds) discharges. The experimental observations show that deionised water is better suited for high voltage applications and also offer a comparison of the discharge behaviour with different electrodes and polarities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving a high-efficiency, gated spectrometer for x-ray Thomson scattering experiments at the National Ignition Facility

We are developing x-ray Thomson scattering for applications in implosion experiments at the National Ignition Facility. In particular we have designed and fielded MACS, a high-efficiency, gated x-ray spectrometer at 7.5–10 keV [T. Döppner et al., Rev. Sci. Instrum. 85, 11D617 (2014)]. Here we report on two new Bragg crystals based on Highly Oriented Pyrolytic Graphite (HOPG), a flat crystal and a dual-section cylindrically curved crystal. We have performed in situ calibration measurements using a brass foil target, and we used the flat HOPG crystal to measure Mo K-shell emission at 18 keV in 2nd order diffraction. Such high photon energy line emission will be required to penetrate and probe ultra-high-density plasmas or plasmas of mid-Z elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic resonance visualization of conductive structures by sequence-triggered direct currents and spin-echo phase imaging

Purpose: Instrument visualization in interventional magnetic resonance imaging (MRI) is commonly performed via susceptibility artifacts. Unfortunately, this approach suffers from limited conspicuity in inhomogeneous tissue and disturbed spatial encoding. Also, susceptibility artifacts are controllable only by sequence parameters. This work presents the basics of a new visualization method overcoming such problems by applying sequence-triggered direct current (DC) pulses in spin-echo (SE) imaging. SE phase images allow for background free current path localization. Methods: Application of a sequence-triggered DC pulse in SE imaging, e.g., during a time period between radiofrequency excitation and refocusing, results in transient field inhomogeneities. Dependent on the additional z-magnetic field from the DC, a phase offset results despite the refocusing pulse. False spatial encoding is avoided by DC application during periods when read-out or slice-encoding gradients are inactive. A water phantom containing a brass conductor (water equivalent susceptibility) and a titanium needle (serving as susceptibility source) was used to demonstrate the feasibility. Artifact dependence on current strength and orientation was examined. Results: Without DC, the brass conductor was only visible due to its water displacement. The titanium needle showed typical susceptibility artifacts. Applying triggered DC pulses, the phase offset of spins near the conductor appeared. Because SE phase images are homogenous also in regions of persistent field inhomogeneities, the position of the conductor could be determined with high reliability. Artifact characteristic could be easily controlled by amperage leaving sequence parameters unchanged. For an angle of 30° between current and static field visualization was still possible. Conclusions: SE phase images display the position of a conductor carrying pulsed DC free from artifacts caused by persistent field inhomogeneities. Magnitude and phase images are acquired simultaneously under the same conditions without the use of extra measurement time. The presented technique offers many advantages for precise instrument localization in interventional MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying uncertainty from material inhomogeneity.

Most engineering materials are inherently inhomogeneous in their processing, internal structure, properties, and performance. Their properties are therefore statistical rather than deterministic. These inhomogeneities manifest across multiple length and time scales, leading to variabilities, i.e. statistical distributions, that are necessary to accurately describe each stage in the process-structure-properties hierarchy, and are ultimately the primary source of uncertainty in performance of the material and component. When localized events are responsible for component failure, or when component dimensions are on the order of microstructural features, this uncertainty is particularly important. For ultra-high reliability applications, the uncertainty is compounded by a lack of data describing the extremely rare events. Hands-on testing alone cannot supply sufficient data for this purpose. To date, there is no robust or coherent method to quantify this uncertainty so that it can be used in a predictive manner at the component length scale. The research presented in this report begins to address this lack of capability through a systematic study of the effects of microstructure on the strain concentration at a hole. To achieve the strain concentration, small circular holes (approximately 100 {micro}m in diameter) were machined into brass tensile specimens using a femto-second laser. The brass was annealed at 450 C, 600 C, and 800 C to produce three hole-to-grain size ratios of approximately 7, 1, and 1/7. Electron backscatter diffraction experiments were used to guide the construction of digital microstructures for finite element simulations of uniaxial tension. Digital image correlation experiments were used to qualitatively validate the numerical simulations. The simulations were performed iteratively to generate statistics describing the distribution of plastic strain at the hole in varying microstructural environments. In both the experiments and simulations, the deformation behavior was found to depend strongly on the character of the nearby microstructure.

36 MATERIALS SCIENCE↗

Atomic-level heterogeneity and defect dynamics in concentrated solid-solution alloys

Performance enhancement of structural materials in extreme radiation environments has been activelyinvestigated for many decades. Traditional alloys, such as steel, brass and aluminum alloys, normallycontain one or two principal element(s) with a low concentration of other elements. While these existin either a mixture of metallic phases (multiple phases) or in a solid solution (single phase), limited orlocalized chemical disorder is a common characteristic of the main matrix. Fundamentally different fromtraditional alloys, recently developed single-phase concentrated solid-solutio n alloys (CSAs) contain mul-tiple elemental species in equiatomic or high concentrations with different elements randomly arrangedon a crystalline lattice. Due to the lack of ordered elemental arrangement in these CSAs, they exhibit sig-nificant chemical disorder and unique site-to-site lattice distortion. While it is well recognized intraditional alloys that minor additions lead to enhanced radiation resistance, it remains unclear inCSAs how atomic-level heterogeneity affects defect formation, damage accumulation, and microstruc-tural evolution. These knowledge gaps have acted as roadblocks to the development of future-generation energy technology. CSAs with a simple crystal structure, but complex chemical disorder,are unique systems that allow us, through replacing principal alloying elements and modifying concen-trations, to study how compositional complexity influences defect dynamics, and to bridge the knowl-edge gaps through understanding intricate electronic- and atomic-level interactions, mass and energytransfer processes, and radiation resistance performance. Recent advances in defect dynamics and irradi-ation performance of CSAs are reviewed, intrinsic chemical effects on radiation performance arediscussed, and direction for future studies is suggested.

Zhang, Yanwen↗

Effect of niobium and phase transformation temperature on the microstructure and texture of a novel 0.40% C thermomechanically processed steel

Field emission scanning electron microscopy, electron backscatter diffraction (EBSD) and X-ray diffraction (XRD) have been employed to investigate the effect of niobium and phase transformation temperature on the evolution of microstructure and texture in a novel thermomechanically processed, medium‑carbon, low-alloy steel intended for slurry pipeline applications. Thermomechanical processing consisted of hot-rolling in the austenitic region with deformation both above the recrystallization limit temperature and below the recrystallization stop temperature. Immediately after rolling, specimens were directly quenched in water to two different temperatures of 560 °C and 420 °C and subsequently furnace cooled from those temperatures to simulate the cooling of coiled strip on a hot strip mill. The microstructure of samples quenched to 560 °C mostly comprised of upper bainite, whereas the samples quenched to 420 °C mainly consisted of lath-type lower bainite. The transformation texture of all samples at the mid-thickness position consisted of α, γ and ε-fibers with high intensities close to the transformed copper, transformed brass and rotated cube components. The addition of 0.013 wt% Nb refined the microstructure and sharpened the texture. The texture of the small fraction of retained austenite present in the final microstructures indicated that the main bcc texture components result from the brass and copper components in the parent austenite.

36 MATERIALS SCIENCE↗

Lithiophilic 3D Porous CuZn Current Collector for Stable Lithium Metal Batteries

Lithium (Li) dendrites formed from nonuniform Li deposition limit potential uses of Li metal as an anode material. Here, we report a lithiophilic 3D porous CuZn current collector that mitigates dendrite formation and realizes the high stability of Li anodes. As opposed to the common metal current collector of copper (Cu), calculations and in situ experiments demonstrate that copper zinc (CuZn) alloys found in commercially available brass are lithiophilic and promote uniform Li deposition. Facile dealloying methods are applied to provide sufficient Li deposition and volume expansion space in brass sheets. Residual CuZn alloys in the framework are found to induce uniform Li deposition and stabilize Li dendrite growth. The optimal current collector (2h-3D CuZn) runs smoothly over 220 cycles at 0.5 mA cm –2 with improved Coulombic efficiencies at high current density. Lastly, this demonstrates an economic and facile CuZn preparation method that unlocks the full potential of Li anodes and provides new Li battery stabilization approaches.

25 ENERGY STORAGE↗

Rhombohedrally Distorted γ-Au 5– x Zn 8+ y Phases in the Au–Zn System

The region of the Au–Zn phase diagram encompassing γ-brass-type phases has been studied experimentally from 45 to 85 atom % Zn. The γ phases were obtained directly from the pure elements by heating to 680 °C in evacuated silica tubes, followed by annealing at 300 °C. Powder X-ray and single-crystal diffraction studies show that γ-“Au5Zn8” phases adopt a rhombohedrally distorted Cr5Al8 structure type rather than the cubic Cu5Zn8 type. The refined compositions from two single crystals extracted from the Zn- and Au-rich loadings are Au4.27(3)Zn8.26(3)γ0.47 (I) and Au4.58(3)Zn8.12(3)γ0.3 (II), respectively (γ = vacancy). These (I and II) refinements indicated both nonstatistical mixing of Au and Zn atoms as well as partially ordered vacancy distributions. The structures of these γ phases were solved in the acentric space group R3m (No. 160, Z = 6), and the observed lattice parameters from powder patterns were found to be a = 13.1029(6) and 13.1345(8) Å and c = 8.0410(4) and 8.1103(6) Å for crystals I and II, respectively. According to single-crystal refinements, the vacancies were found on the outer tetrahedron (OT) and octahedron (OH) of the 26-atom cluster. Single-crystal structural refinement clearly showed that the vacancy content per unit cell increases with increasing Zn, or valence-electron concentration. Electronic structure calculations, using the tight-binding linear muffin-tin orbital method with the atomic-sphere approximation (TB-LMTO-ASA) method, indicated the presence of a well-pronounced pseudogap at the Fermi level for “Au5Zn8” as the representative composition, an outcome that is consistent with the Hume–Rothery interpretation of γ brass.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of ambient gas confinement, plasma chemistry, and focusing conditions on emission features of femtosecond laser-produced plasmas

Ultrafast laser ablation coupled with optical emission spectroscopy is currently under development for standoff detection of elements and their isotopes for a wide range of application areas. In this work, we explore the role of ambient air pressure during the interaction of an ultrafast laser beam with two metallic targets (brass and uranium) with significantly different oxygen gas-phase reactivity. Plasma plumes were generated by focusing ~800 nm, ~35 fs pulses from an ultrafast laser system using a long focal length lens with f = 1 m. Two-dimensional spectral imaging was performed over the pressure range of 30 mTorr-700 Torr air to evaluate emission dynamics, plasma chemistry, signal-to-background ratio, and characteristic parameters (i.e. excitation temperature, electron density). An increase in ambient air pressure during ultrafast laser ablation leads to plume confinement and subsequent changes in the emission dynamics due to plasma chemistry as well as changes in plasma generation conditions (i.e. focused fs laser ablation versus filament ablation). Ablation crater morphologies were also investigated via scanning electron microscopy. Results indicate atomic emission intensity and signal-to-background ratios peak at moderate pressure levels (~50-100 Torr air) for both targets studied, although plasma chemistry influences uranium emission signatures. The emission features of the uranium plasma at pressures = 10 Torr showed the presence of atoms and oxide molecules which are co-located within the plume. We also find filament ablation leads to wider, more shallow craters compared to focused laser ablation. Our study provides unique insight into the interplay between plume dynamics, confinement, and oxygen chemistry of fs laser-produced plasmas and how these phenomena evolve with changing ambient air pressure.

Laser-produced plasma↗