Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

A NEW DIFFERENTIAL AND ERRANT BEAM CURRENT MONITOR FOR THE SNS* ACCELERATOR

A new Differential and errant Beam Current Monitor (DBCM) is being implemented for both the Spallation Neutron Source's Medium Energy Beam Transport (MEBT) and the Super Conducting Linac (SCL) accelerator sections. These new current monitors will abort the beam when the difference between two toroidal pickups exceeds a threshold. The MEBT DBCM will protect the MEBT chopper target, while the SCL DBCM will abort beam to minimize fast beam losses in the SCL cavities. The new DBCM will also record instances of errant beam, such as beam dropouts, to assist in further optimization of the SNS Accelerator. A software Errant Beam Monitor was implemented on the regular BCM hardware to study errant beam pulses. The new system will take over this functionality and will also be able to abort beam on pulse-to-pulse variations. Because the system is based on the FlexRIO hardware and programmed in LabVIEW FPGA, it will be able to abort beam in about 5 us. This paper describes the development, implementation, and initial test results of the DBCM, as well as errant beam examples.

beam current monitor↗

An Online Beam Loss Monitor for NSLS-II Storage Ring

Reliable beam loss monitors are important tools for the safe operation of the accelerators. Beam loss monitors provide valuable information on the magnitude and location of the particle beam loss inside the accelerator enclosures. In the synchrotron radiation facilities, the electron accelerator enclosures experience a mixed radiation environment, consisting of low energy x-ray background along with bremsstrahlung and photoneutrons.

36 MATERIALS SCIENCE↗

FPGA Architectures for Distributed ML Systems for Real-time Beam Loss De-blending

The Accelerator Real-time Edge AI for Distributed Systems (READS) project’s goal is to create a Artificial Intelligence (AI) system for real-time beam loss de-blending within the accelerator enclosure, which houses two accelerators: the Main Injector (MI) and the Recycler Ring (RR). In periods of joint operation, when both machines contain high intensity beam, radioactive beam losses from MI and RR overlap on the enclosure’s beam loss monitoring Beam Loss Monitor (BLM) system, making it difficult to attribute those losses to a single machine. Incorrect diagnoses result in unnecessary downtime that incurs both financialand experimental cost. The ML system will automatically disentangle each machine’s contributions to those measured losses, while not disrupting the existing operations-critical functions of the BLM system. This paper will focus on the evolution of the architectures, which provided the high-frequency, low-latency collection of synchronized data streams to make real-time inferences. The ML models, used for learning both local and global machine signatures and producing high quality inferences based on raw BLM loss measurements, will only be discussed at a high-level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Position Monitor: Sensors, Calibration and Analysis [Slides]

A beam position monitor (BPM) provides information on electron beam current and position, essential to meeting the performance requirements for the Scorpius accelerator as laid down in FR1.1 –FR1.8 and FR2.2. The critical elements in employing BPM’s to meet those requirements are design of the sensor, design of calibration equipment for the sensor, and design of methods to record and process data.

43 PARTICLE ACCELERATORS↗

The LCLS Undulator Beam Loss Monitor Readout System

The LCLS Undulator Beam Loss Monitor System is required to detect any loss radiation seen by the FEL undulators. The undulator segments consist of permanent magnets which are very sensitive to radiation damage. The operational goal is to keep demagnetization below 0.01% over the life of the LCLS. The BLM system is designed to help achieve this goal by detecting any loss radiation and indicating a fault condition if the radiation level exceeds a certain threshold. Upon reception of this fault signal, the LCLS Machine Protection System takes appropriate action by either halting or rate limiting the beam. The BLM detector consists of a PMT coupled to a Cherenkov radiator located near the upstream end of each undulator segment. There are 33 BLMs in the system, one per segment. The detectors are read out by a dedicated system that is integrated directly into the LCLS MPS. The BLM readout system provides monitoring of radiation levels, computation of integrated doses, detection of radiation excursions beyond set thresholds, fault reporting and control of BLM system functions. This paper describes the design, construction and operational performance of the BLM readout system.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

A beam intensity monitor for the evaluation beamline for soft x-ray optical elements

Evaluation Beamline for Soft X-Ray Optical Elements (BL-11) at the SR Center of Ritsumeikan University has been operated to measure the wavelength and angular characteristics of soft x-ray optical components in a wavelength range of 0.65-25 nm using a reflecto-diffractometer (RD). The beam intensity monitor that has been equipped in BL-11 has observed the signal of the zero-th order light. For the purpose of more accurate evaluation of the performance of optical components, a new beam intensity monitor to measure the intensity of the first order light from the monochromator in BL-11 has been developed and installed in just front of RD. The strong positive correlation between the signal of the beam monitor and a detector equipped in the RD is shown. It is successful that the beam intensity of the first order light can be monitored in real time.

43 PARTICLE ACCELERATORS↗

Dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources

A dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources includes a detector arrangement consists of three detectors downstream from the object under observation. The latter detector, which operates as a beam monitor, is an integrating detector that monitors the total beam power arriving at its surface. The first detector and the middle detector each include an integrating detector surrounding a foil. The foils of these two detectors are made of the same atomic material, but each foil is a different isotope, e.g., the first foil may comprise U235 and second foil may comprise U238. The integrating detectors surrounding these pieces of foil measure the total power scattered from the foil and can be similar in composition to the final beam monitor. Non-resonant photons will, after calibration, scatter equally from both foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

42 ENGINEERING↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New x-ray pink-beam profile monitor system for the SPring-8 beamline front-end

A new beam profile monitoring system for the small X-ray beam exiting from the SPring-8 front-end was developed and tested at BL13XU. This system is intended as a screen monitor and also as a position monitor even at beam currents of 100 mA by using photoluminescence of a chemical vapor deposition-grown diamond film. To cope with the challenge that the spatial distribution of the photoluminescence in the vertical direction is too flat to detect the beam centroid within a limited narrow aperture, a filter was installed that absorbs the fundamental harmonic concentrated in the beam center, which resulted in “de-flattening” of the vertical distribution. For the measurement, the filter crossed the photon beam vertically at high speed to withstand the intense heat flux of the undulator pink-beam. A transient thermal analysis, which can simulate the movement of the irradiation position with time, was conducted to determine the appropriate configuration and the required moving speed of the filter to avoid accidental melting. In a demonstration experiment, the vertically separated beam profile could be successfully observed for a 0.8 × 0.8 mm{sup 2} beam shaped by an XY slit and with a fundamental energy of 18.48 keV. The vertical beam centroid could be detected with a resolution of less than 0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection system. The new Beam-Loss Monitor system allows appropriate abort logic and thresholds to be set over the full set of collider operating conditions. The system also records a history of beam-loss data prior to a beam-abort event for post-abort analysis. Installation of the Main Injector system occurred in the fall of 2006 and the Tevatron system in the summer of 2007. Both systems were fully operation by the summer of 2008. In this paper we report on the overall system design, provide a description of its normal operation, and show a number of examples of its use in both the Main Injector and Tevatron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

A Diamagnetic-Loop-Based Beam Radius Monitor (BRM)

We describe a non-interceptive beam radius monitor that employs a diamagnetic loop. In order to increase the signal strength, the diamagnetic loop radius is considerably smaller than the outer wall radius, the device is placed inside a specially built solenoid magnet to allow independent adjustment of the guide magnetic field strength, and there are two counter-wound diamagnetic loops to double the signal strength and to eliminate common mode signals. This device is calibrated and the magnitude of the electron beam offset/tilt contribution to the measured radius estimated. This device is ready to be validated on an electron induction LINAC such a DARHT-I or DARHT-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Position Monitoring System for Fermilab’s Muon Campus

A Beam Position Monitor (BPM) system has been designed for Fermilab Muon Campus. The BPM system measures Turn-by-Turn orbits as well as Closed Orbits (average of multiple turns). While in the early commissioning phase of this program, preliminary measurements have been made using these BPMs. This paper discusses the design and implementation of these BPMs.

43 PARTICLE ACCELERATORS↗

EIC ESR beam position monitors thermal and thermomechanical study preliminary design

The Electron Ion Collider (EIC) Electron Storage Ring (ESR) Beam Position Monitors (BPM) are designed to monitor the electron beam orbit position on a turn-by-turn and bunch-by-bunch basis in the vacuum chamber. Large variations in ESR fill pattern and bunch intensity imposes a large dynamic range on the BPM system design. And given the large ESR beam current - up to 2.5 A with 1160 x 20 nC bunches – the heating by synchrotron radiation (SR) and beam impedance is a significant concern. The high energy of the electrons – up to 18 GeV – leads to scat tering of the SR that produces high radiation doses and as sociated heating of structures away from the SR impact area. Because of this intense heating, and stringent position stability requirements, an in-depth engineering analysis was carried out. This paper will review the analysis made of the preliminary design and its main outcomes.

43 PARTICLE ACCELERATORS↗