Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM BENDING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Superbend X-Ray Microdiffraction Beamline at the Advanced Light Source

Beamline 12.3.2 at the Advanced Light Source is a newly commissioned beamline dedicated to x-ray microdiffraction. It operates in both monochromatic and polychromatic radiation mode. The facility uses a superconducting bending magnet source to deliver an X-ray spectrum ranging from 5 to 22 keV. The beam is focused down to {approx} 1 um size at the sample position using a pair of elliptically bent Kirkpatrick-Baez mirrors enclosed in a vacuum box. The sample placed on high precision stages can be raster-scanned under the microbeam while a diffraction pattern is taken at each step. The arrays of diffraction patterns are then analyzed to derive distribution maps of phases, strain/stress and/or plastic deformation inside the sample.

36 MATERIALS SCIENCE↗

Bent Bragg–Laue monochromator for high-energy X-rays

A bent Bragg–Laue monochromator (BLM) is proposed for high-energy X-ray (~25–60 keV) beamlines. The BLM has the unique feature of bi-directional focusing. A sagittally bent Laue crystal can focus the large horizontal fan of a bending magnet or wiggler source. A meridionally bent Bragg crystal focuses the beam vertically and corrects for the anticlastic bending effects of the Laue crystal. This monochromator geometry relies on the crystal orientations being optimized. We show that the focusing condition and Rowland condition can be simultaneously satisfied at a given energy. A detailed ray tracings indicate that a BLM can provide similar energy resolution and higher flux density compared to a sagittally bent double-Laue monochromator configuration. A prototype BLM with a symmetric Bragg crystal and an asymmetric Laue crystal was tested. Matching of the bend radii of the two crystals in the meridional direction was demonstrated. Generally, the horizontal acceptance of the sagittally bent Laue crystal is limited by the large curvature. This horizontal BLM acceptance could be increased by translating the Laue crystal along its sagittal bending axis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Partially coherent Wavefront Propagation Calculations for Design of Coherence-Preserving Synchrotron Radiation Beamlines

Ultra-low emittance third-generation synchrotron radiation (SR) sources, such as NSLS-II and MAX-IV, will offer excellent opportunities for further development of experimental techniques exploiting X-ray coherence. However, even in these new SR sources, the radiation produced by relativistic electrons (in undulators, wigglers and bending magnets) will remain only partially coherent in the X-ray spectral range. 'Extraction' of 'coherent portion' of the radiation flux and its transport to sample without loss of coherence must be performed by dedicated SR beamlines, optimized for particular types of experiments. Detailed quantitative prediction of partially coherent X-ray beam properties at propagation through optical elements, which is required for the optimization of such beamlines, can only be obtained from accurate and efficient physical-optics based numerical simulations. Examples of such simulations, made for NSLS-II beamlines, using 'Synchrotron Radiation Workshop' (SRW) computer code, are presented. Special attention is paid to the numerical analysis of the basic properties of partially coherent undulator radiation beam and its distinctions from the Gaussian beam. Performance characteristics of importance for particular beamlines, such as radiation spot size and flux at sample vs size of secondary source aperture for high-resolution microscopy beamlines, are predicted by the simulations.

43 PARTICLE ACCELERATORS↗

BXS Re-calibration

Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel indicated that the vacuum chamber was in fact in the proper position with respect to the magnet - not 19 mm off to one side - so the former possibility was discounted. Review of the Fiducial Report and an interview with Keith Caban convinced me that there was no error in the coordinate system used for magnet measurements. I went and interviewed Andrew Fischer who did the magnetic measurements of BXS. He had extensive records, including photographs of the setups and could quickly answer quite detailed questions about how the measurement was done. Before the interview, I had a suspicion there might have been a sign flip in the x coordinate which because of the wedge would result in the wrong path length and a miscalibration. Andrew was able to pin-point how this could have happened and later confirmed it by looking an measurement data from the BXG magnet done just after BXS and comparing photographs. It turned out that the sign of the horizontal stage travel that drives the measurement wire was opposite that of the x coordinate in the Traveler, and the sign difference wasn't applied to the data. The origin x = 0 was set up correctly, but the wire moved in the opposite direction to what was expected, just as if the arc had been flipped over about the origin. To quantitatively confirm that this was the cause of the observed difference in calibration I used the 'grid data', which was taken with a Hall probe on the BXS magnet originally to measure the FINT (focusing effect) term, and combined it with the Hall probe data taken on the flipped trajectory, and performed the field integral on a path that should give the same result as the design path. This is best illustrated in Figure 2. The integration path is coincident with the desired path from the pivot points (x = 0) outward. Between the pivot points the integration path is a mirror image of the design path, but because the magnet is fairly uniform, for this portion it gives the same result. Most of the calibration error resulted simply from the different path length between the design path and the measured path. The results of the integration on the equivalent path are given in Table 1. The corrected calibration has been used to generate a new polynomial for BXS which was implemented in the control system.

43 PARTICLE ACCELERATORS↗

The GlueX Start Counter and Beam Asymmetry$\Sigma$ in Single $\pi^{0}$ Photoproduction

The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H 2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 10 8 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\vec{p}$→ π 0 p, where π 0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A modular optics design for the LBNE beamline

Protons extracted from the Main Injector (MI) in the MI-60 straight section are transported 84 m through quadrupole Q106 in the NuMI stub, at which point two 6-3-120 vertical switching magnets, followed by three EPB vertical dipoles, steer the beam into the main body of the LBNE beamline. From Q106 in NuMI the LBNE beamline transports these protons 722.0 m to the LBNE target, located 41.77 m (137.0 ft) below the MI beamline center (BLC) elevation, on a trajectory aimed towards DUSEL. Bending is provided (predominantly) by 34 long (6 m) MI-style IDA/IDB and 8 short (4 m) IDC/IDD dipoles [through 48.36{sup o} horizontally and -5.844{sup o} (net) vertically]. Optical properties are defined by 49 quadrupoles (grouped functionally into 44 focusing centers) of the proven MI beamline-style 3Q60/3Q120 series. All focusing centers are equipped with redesigned MI-style IDS orbit correctors and dual-plane beam position monitors (BPM's). Ample space is available in each arc cell to accommodate ion pumps and diagnostic instrumentation. Parameters of the main magnets are listed in a table.

43 PARTICLE ACCELERATORS↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

Monochromatic short pulse laser produced ion beam using a compact passive magnetic device

High-intensity laser accelerated protons and ions are emerging sources with complementary characteristics to those of conventional sources, namely high charge, high current, and short bunch duration, and therefore can be useful for dedicated applications. However, these beams exhibit a broadband energy spectrum when, for some experiments, monoenergetic beams are required. We present here an adaptation of conventional chicane devices in a compact form (10 cm × 20 cm) which enables selection of a specific energy interval from the broadband spectrum. This is achieved by employing magnetic fields to bend the trajectory of the laser produced proton beam through two slits in order to select the minimum and maximum beam energy. The device enables a production of a high current, short duration source with a reproducible output spectrum from short pulse laser produced charged particle beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coherent Photoproduction of proton anti-proton pair on deiterium with CLAS

In this project coherent production of proton anti-proton pairs on deuterium with a high energy bremsstrahlung photon beam is studied. The main objective is to study claims of several groups on existence of two meson states, masses ~2.02 GeV and ~2.2 GeV. Coherent production on deuterium has an advantage compared to the production on hydrogen. It will eliminate ambiguities in the production mechanism, since only t-channel production of (p$\bar{p}$) is allowed. Data from the CLAS detector at Jefferson Lab (TJNAF) has been analyzed. The experiment run in 2004-2005 with tagged bremsstrahlung photon beam of up to 5.5 GeV and a 40 cm long liquid deuterium target. During the experiment the CLAS torus magnet polarity was set to bend negatively charged particles outwards from the beam line. During the run the main trigger was tagger hodoscopes in relevant energy region in coincidence with three prong event in CLAS. The reactions γd→p$\bar{p}$-d, γd→π + π - d, and γd→K + K - d in fully exclusive final states has been analyzed, and the cross sections have been extracted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status and new features of the topography beamline 1-BM after the Advanced Photon Source upgrade

The beamline 1-BM of the Advanced Photon Source (APS), a bending-magnet beamline with an effective X-ray beam size of ~100×4 mm2, has relatively comprehensive synchrotron topography and rocking curve imaging capabilities for characterization of crystals (particularly wide-bandgap semiconductors SiC, AlN, GaN, Ga2O3 etc). It is equipped with a white-beam topography stage for imaging large wafers up to 8 inches. It also has a double-crystal setup, of which the second stage can be used for monochromatic-beam topography. The first stage has different beam conditioners in the grazing-incidence geometry that can expand the vertical beam size from 4 to ~100 mm for double-crystal rocking curve imaging when it is combined with the second stage. Recently APS has been upgraded to a modern 4th-generation light source, and 1-BM has been recommissioned to its normal operation for general users with better performance. The upgraded APS leads to new features at 1-BM. The much smaller source size and higher X-ray coherence significantly improve the image resolution and contrast. The higher flux and brightness of the new source reduce exposure time, which mitigates the mechanical drifting and vibration issues. Here the main capabilities and status of 1-BM together with these new features are introduced.

X-ray topography↗

The GlueX Start Counter Detector

The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic reconnection and kinetic waves generated in the Earth's quasi-parallel bow shock

Magnetic reconnection in quasi-parallel shocks, relevant to the Earth’s bow shock, is studied by means of two-dimensional full particle-in-cell simulations. As the Alfvénic Mach number increases, the propagation direction of the waves excited in the transition region changes, and the shock becomes more turbulent with more reconnection sites. In the higher Mach number shock, abundant electron-only reconnection sites are generated with scales on the order of the ion skin depth or less. Non-reconnecting current sheets can also generate electron jets and energy dissipation can occur there as well. However, non-reconnecting current sheets with the magnetic field reversal typically show a smaller energy dissipation rate than reconnecting current sheets. In the shock transition region, two types of waves are responsible for driving reconnection: one has a wavelength around three ion skin depths (d i ), and the other has a wavelength less than 1 d i . Here, electron and ion distribution functions show that in regions where the former type of waves is excited, there are two ion beams and a single-peaked electron distribution. In contrast, in regions where the latter type of waves is excited, there are multiple electron and ion beams. The waves propagating obliquely to the magnetic field bend the magnetic field lines, and magnetic reconnection occurs where oppositely directed field lines come into contact.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Further Progress on a Design for a Super-B Interaction Region

We present an improved design for a SuperB interaction region. The new design minimizes local bending of the two colliding beams by separating all beam magnetic elements near the Interaction Point (IP). The total crossing angle at the IP is increased from 48 mrad to 60 mrad. The first magnetic element is a six slice Permanent Magnet (PM) quadrupole with an elliptical aperture allowing us to increase the vertical space for the beam. This magnet starts 36 cm from the Interaction Point (IP). This magnet is only seen by the Low-Energy Beam (LEB), the High-Energy Beam (HEB) has a drift space at this location. This allows the preliminary focusing of the LEB which has a smaller beta y* at the IP than the HEB. The rest of the final focusing for both beams is achieved by two super-conducting side-by-side quadrupoles (QD0 and QF1). These sets of magnets are enclosed in a warm bore cryostat located behind the PM quadrupole for the LEB. We describe this design for the interaction region.

43 PARTICLE ACCELERATORS↗

XAFS Study of Epitaxial Co[subscript x]Ti[subscript 1-x]O[subscript 2-x] Anatase

Co doped TiO{sub 2}-anatase is a promising candidate for a room-temperature ferromagnetic semiconductor. XAFS measurements have been used to investigate the local Co environment and Co valence for several Co-anatase films. The samples were grown on LaAlO{sub 3} (001) by oxygen plasma assisted molecular beam epitaxy and on SrTiO{sub 3} by atomic oxygen assisted MBE. Co concentrations were about 5%. The measurements were made at the PNC-CAT bending magnet and undulator beamlines at the Advanced Photon Source. For the films on LaAlO{sub 3}, the near edge clearly shows the presence of only Co(2+), and no evidence for metallic Co, while the films on SrTiO{sub 3} showed significant metallic Co. Analysis of the extended fine structure for the LaAlO{sub 3} films finds that the Co substitutes for Ti with some distortion of the lattice. Both in-plane and out-of-plane Co-O bonds are expanded from the Ti-O bonds in anatase. The in-plane bonds are expanded approximately twice as much. A deficit in the oxygen coordination number suggests a correlation of oxygen vacancies with Co sites.

36 MATERIALS SCIENCE↗

Calculation of the transverse kicks generated by the bends of a hollow electron lens

Electron lenses are pulsed, magnetically confined electron beams whose current-density profile is shaped to obtain the desired effect on the circulating beam in high-energy accelerators. They were used in the Fermilab Tevatron collider for abort-gap clearing, beam-beam compensation, and halo scraping. A beam-beam compensation scheme based upon electron lenses is currently being implemented in the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. This work is in support of a conceptual design of hollow electron beam scraper for the Large Hadron Collider. It also applies to the implementation of nonlinear integrable optics with electron lenses in the Integrable Optics Test Accelerator at Fermilab. We consider the axial asymmetries of the electron beam caused by the bends that are used to inject electrons into the interaction region and to extract them. A distribution of electron macroparticles is deposited on a discrete grid enclosed in a conducting pipe. The electrostatic potential and electric fields are calculated using numerical Poisson solvers. The kicks experienced by the circulating beam are estimated by integrating the electric fields over straight trajectories. These kicks are also provided in the form of interpolated analytical symplectic maps for numerical tracking simulations, which are needed to estimate the effects of the electron lens imperfections on proton lifetimes, emittance growth, and dynamic aperture. We outline a general procedure to calculate the magnitude of the transverse proton kicks, which can then be generalized, if needed, to include further refinements such as the space-charge evolution of the electron beam, magnetic fields generated by the electron current, and longitudinal proton dynamics.

Stancari, Giulio↗

Effects of Potential Energy Spread on Particle Dynamics in Magnetic Bending Systems

Understanding CSR effects for the generation and transport of high brightness electron beams is crucial for designs of modern FELs. Most studies of CSR effects focus on the impacts of the longitudinal CSR wakefield. In this study, we investigate the impact of the initial retarded potential energy of particles, due to bunch collective interaction, on the transverse dynamics of particles on a curved orbit. It is shown that as part of the remnants of the CSR cancellation effect when both the longitudinal and transverse CSR fores are taken into account, this initial potential energy at the entrance of a bending system acts as a pseudo kinetic energy, or pseudo energy in short, because its effect on particle optics through dispersion and momentum compaction is indistinguishable from effect of the usual kinetic energy offset from the design energy. Our estimation indicates that the resulting effect of pseudo energy spread can be measurable only when the peak current of the bunch is high enough such that the slice pseudo energy spread is appreciable compared to the slice kinetic energy spread. The implication of this study on simulations and experiments of CSR effects will be discussed.

Li, R.↗

SU-F-T-279: Impact of Beam Energy Drifts On IMRT Delivery Accuracy

Purpose: According to TG-40 percent-depth-dose (PDD) tolerance is ±2% but TG-142 is ±1%. Now the question is, which one is relevant in IMRT era? The primary objective of this study is to evaluate dosimetric impact of beam-energy-drifts on IMRT-delivery. Methods: Beam-energy drifts were simulated by adjusting Linac’s bending-magnet-current (BMC) followed by tuning the pulse-forming network and adjusting gun-current. PDD change of −0.6% and +1.2% were tested. Planar-dosimetry measurements were performed using an ionization-chamber-array in solid-water phantoms. Study includes 10-head-and-neck and 3-breast cancer patients. en-face beam-deliveries were also tested at 1.3cm and 5.3cm depths. Composite and single-field dose-distributions were compared against the plans to determine %Gamma pass-rates (%GPRs). For plan dose comparisons, changes in %Gamma pass-rates (cPGPRs) were computed/reported to exclude the differences between dose-computation and delivery. Dose distributions of the drifted-energies were compared against their baseline measurements to determine the% GPRs. A Gamma criteria of 3%/3mm was considered for plan-dose comparisons while 3%/1mm used for measured dose intercomparisons. Results: For composite-dose delivery, average cPGPRs were 0.41%±2.48% and −2.54%±3.65% for low-energy (LE) and high-energy (HE) drifts, respectively. For measured dose inter-comparisons, the average%GPRs were 98.4%±2.2% (LE-drift) and 95.8%±4.0 (HE-drift). The average %GPR of 92.6%±4.3% was noted for the worst-case scenario comparing LE-drift to HE-drift. All en-face beams at 5.3 cm depth have cPGPRs within ±4% of the baseline-energy measurements. However, greater variations were noted for 1.3cm depth. Average %GPRs for drifted energies were >99% at 5.3cm and >97% at 1.3cm depths. However, for the worst-case scenario (LE-drift to HE-drift) these numbers dropped to 95.2% at 5.3cm and 93.1% at 1.3cm depths. Conclusion: The dosimetric impact of beam-energy drifts was found to be within clinically acceptable tolerance. However, this study includes a single energy with limited range of PDD change. Further studies are on going and the results will be presented. Received funding from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-E-T-359: Measurement of Various Metrics to Determine Changes in Megavoltage Photon Beam Energy

Purpose: To examine the relationship between photon beam energy and various metrics for energy on the flattened and flattening filter free (FFF) beams generated by the Varian TrueBeam. Methods: Energy changes were accomplished by adjusting the bending magnet current ±10% from the nominal value for the 4, 6, 8, and 10 MV flattened and 6 and 10 MV FFF beams. Profiles were measured for a 30×30 cm{sup 2} field using a 2D ionization chamber array and a 3D water Scanner which was also used to measure PDDs. For flattened beams we compared several energy metrics; PDD at 10 cm depth in water (PDD(10)); the variation over the central 80% of the field (Flat); and the average of the highest reading along each diagonal divided by the CAX value, diagonal normalized flatness (FDN). For FFF beams we examined PDD(10), FDN, and the width of a chosen isodose level in a 30×30 cm{sup 2} field (W(d%)). Results: Changes in PDD(10) were nearly linear with changes in energy for both flattened and FFF beams as were changes in FDN. Changes in W(d%) were also nearly linear with energy for the FFF beams. PDD(10) was not as sensitive to changes in energy compared to the other metrics for either flattened or FFF beams. Flat was not as sensitive to changes in energy compared to FDN for flattened beams and its behavior depends on depth. FDN was the metric that had the highest sensitivity to the changes in energy for flattened beams while W(d%) was the metric that had highest sensitivity to the changes in energy for FFF beams. Conclusions: The metric FDN was found to be most sensitive to energy changes for flattened beams, while the W(d%) was most sensitive to energy changes for FFF beams.

07 ISOTOPE AND RADIATION SOURCES↗