Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Average Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Orbit-averaging and deposition accuracy for runaway electron beams in hybrid kinetic-MHD simulations of the runaway plateau

We develop a new procedure that combines the kinetic orbit runaway electron code (KORC) and the NIMROD extended-magnetohydrodynamic code to simulate runaway electrons (REs) in the post-disruption plateau. KORC integrates guiding-center orbits, with a barycentric-based binary search strategy providing initial guesses for the Newton–Raphson logical-to-physical coordinate inversion, ensuring reliable particle-to-mesh mapping in NIMROD, whose fields remain static for the present study. Samples are drawn in accord with experimental parallel current profiles of RE beams during the plateau phase. Deposition in NIMROD is verified through comparison with a Python-based finite-element code that ensures periodicity in the poloidal direction and continuity at the magnetic axis. Accurate representation of near-axis fields requires finer mesh resolution to prevent under- and overshoots in current density from orbit inaccuracies. Yet, at a fixed particle count, increasing mesh resolution amplifies statistical noise in the deposited fields. An orbit-averaging method accumulates partial current deposits over multiple kinetic steps and reduces the statistical noise with little added computational cost. By coupling kinetic routines from KORC directly into the NIMROD codebase, these developments lay essential groundwork for future self-consistent KORC–NIMROD coupling.

Algorithms and data structure↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Image quality and diagnostic accuracy of complex-averaged high b value images in diffusion-weighted MRI of prostate cancer

Purpose: To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI. Materials and methods: This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm{sup 2}) and one higher b value (aHBV at 2000 s/mm{sup 2}). The acquired data were postprocessed to generate two different types of trace-weighted images—using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm{sup 2}) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm{sup 2}) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores. Results: Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm{sup 2} sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time). Conclusion: Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions . The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine Learning Models for Mapping Groundwater Pollution Risk: Advancing Water Security and Sustainable Development Goals in Georgia, USA

The widespread use of pesticides, such as atrazine and malathion, in agricultural systems raises significant concerns regarding the contamination of groundwater, which serves as a critical resource for drinking water. This study applies machine learning techniques to predict the concentrations of atrazine and malathion in groundwater across Georgia, USA, using 2019 data. A Random Forest classifier was employed to integrate various environmental and demographic factors, including pesticide application rates, precipitation, lithology, and population density, to predict pesticide contamination in groundwater. The models demonstrated high training accuracies of 100% and moderate average testing accuracy of 55% for atrazine and 60% for malathion across five iterations. The low test accuracy of the model, ranging from 50% to 75%, is likely due to overfitting, which can be attributed to the small dataset size and the complex nature of pesticide-contamination patterns, making it challenging for the model to generalize to unseen data. Feature importance analysis revealed that average pesticide usage emerged as the most influential factor for atrazine, while aquifer lithology and precipitation played crucial roles in both models. These results provide valuable insights into the dynamics of pesticide contamination, highlighting areas at greater risk of contamination. The findings underscore the importance of integrating environmental, geological, and agricultural variables for more effective groundwater management and sustainable agricultural practices, contributing to the protection of water resources and public health.

54 ENVIRONMENTAL SCIENCES↗

GOLEM: GOld standard for Learning and Evaluation of Motifs

Motifs are distinctive, recurring, widely used idiom-like words or phrases, often originating from folklore, whose meaning is anchored in a narrative and have a significance as communicative devices across a wide range of media, including news, literature, and propaganda. Many motifs concisely imply a large constellation of culturally relevant information, and their broad usage suggests their cognitive importance as touchstones of cultural knowledge. As such, their detection is a step towards culturally aware natural language processing. We present GOLEM (GOld standard for Learning and Evaluation of Motifs) a dataset of English news articles, opinion pieces, and broadcast transcripts annotated for motific information. The dataset identifies 25,737 motif candidates across 34 motif types drawn from three cultural or national groups: Jewish, Irish, and Puerto Rican. The dataset contains 2,024,141 words split into 25,737 text snippets drawn from 8,073 articles. Each motif candidate is labeled according to a scheme which identifies the type of usage (motific, referential, eponymic, or unrelated), resulting in 1,743 actual motific instances in the data. Annotation was performed by individuals identifying as members of each group and achieved a Fleiss’ kappa (?) of > 0.55. In addition to the data, we demonstrate that classification of the candidate type is a challenging task for Large Language Models (LLMs) using a few-shot approach; recent models such as T5, FLAN-T5, GPT-2, and Llama 2 (7B) achieved a performance of 41% accuracy at best, where the majority class accuracy is 41% and the average chance accuracy is 27%. These data will support development of new models and approaches for detecting (and reasoning about) motific information in text.

motif, culture, natural language, artificial intel↗

MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.

60 APPLIED LIFE SCIENCES↗

Identifying Sociomarkers of Pediatric Asthma Patients at Risk of Hospital Revisiting

ObjectiveAsthma is one of the most common chronic childhood diseases in the United States [2, 3]. In addition to its pervasiveness, pediatric asthma shows high sensitivity to the environment. Combining medical-social dataset with machine learning methods we demonstrate how socio-markers play an important role in identifying patients at risk of hospital revisits due to pediatric asthma within a year.IntroductionA socio-marker is a measurable indicator of social conditions where a patient is embedded in and exposed to, being analogous with a biomarker indicating the severity or presence of some disease state. Social factors are one of the most clinical health determinants [1], which play a critical role in explaining health outcomes. Socio-markers can help medical practitioners and researchers to reliably identify high-risk individuals in a timely manner.MethodsWe collected data from three different sources: pediatric asthma encounter records from Jan 1st, 2016 to Dec 31st, 2016 at a children’s hospital, the 2010 U.S census data and neighborhood quality survey data by Memphis Property Hub. After merging these datasets we examine the effect of social features in identifying the patients who visited the hospital more than once during the observation period. We only use the first time visit (3,678 cases) to avoid over-counting of the same patients. In addition to demographic features (age, gender, insurance type, and race (African American and White)), we incorporate the social features such as the proportion of individuals living below the federal poverty level, blight prevalence, neighborhood quality, neighborhood quality inequality, trash dumping presence, the broken window pervasiveness within the zip code area of patients’ residence are included.We then implemented a Support Vector Machine (SVM) based classification model using abovementioned 11 social features. The classification outcome is either patient visits the hospital only one-time (class 0) or revisits the hospital within a year (class 1). Among 3,678 unique patients in the dataset, only 823 pediatric patients revisited hospital with asthma. So, to overcome the class imbalance issue, we have used 823 patients’ data (randomly selected in 1,000 iterations) from each class. Further, to avoid overfitting and ensure generalizability, we divided the dataset as training, test, and validation with a proportion of 60%, 20%, and 20%, respectively. The reported test (5-folds cross-validation using training and testing data) and validation accuracy of the SVM method are averaged over 1,000 iterations to avoid sampling error and bias.ResultsThe proposed socio-marker model resulted in an average classification accuracy of 63.70% for the test set and 63.67 % for the validation set. Further, the average specificity (the total true negative cases divided by the sum of true negative and false positive) and sensitivity (the total number of true positive cases divided by the sum of positive predicted cases) is found to be 62.79% and 64.77%, respectively for the test set and 62.79% and 64.83%, respectively for the validation set. Results of this study suggest that socio-marker features that are not directly related to a patient’s medical conditions can still predict whether the patient will come back to the hospital within a year or not with approximately 64% accuracy.ConclusionsBringing the socio-marker features in the surveillance system may ease the burden of detecting the patients at risk of revisiting the hospital. The results should be interpreted with caution because we only used 12-month period of observation and the visit beyond the observation window is not considered. Also the patients may have visited different hospitals which are not captured in the data.References1. Booske BC, Athens JK, Kindig DA, Park H, Remington PL: Different perspectives for assigning weights to determinants of health. University of Wisconsin: Population Health Institute 2010.2. Subbarao P, Mandhane PJ, Sears MR: Asthma: epidemiology, etiology and risk factors. Canadian Medical Association Journal 2009, 181(9):E181-E190.3. Gold DR, Wright R: Population disparities in asthma. Annu Rev Public Health 2005, 26:89-113.

Shin, Eun Kyong↗

First Principles Modeling of RFQ Cooling System and Resonant Frequency Responses for Fermilab’s PIP-II Injector Test

In this study we develop an a priori method for simulating dynamic resonant frequency and temperature responses in a radio frequency quadrupole (RFQ) and its associated water-based cooling system respectively. Our model provides a computationally efficient means to evaluate the transient response of the RFQ over a large range of system parameters. The model was constructed prior to the delivery of the PIP-II Injector Test RFQ and was used to aid in the design of the water-based cooling system, data acquisition system, and resonance control system. Now that the model has been validated with experimental data, it can confidently be used to aid in the design of future RFQ resonance controllers and their associated water-based cooling systems. Finally, without any empirical fitting, it has demonstrated the ability to predict absolute temperature and frequency changes to 11% accuracy on average, and relative changes to 7% accuracy.

43 PARTICLE ACCELERATORS↗

SU-E-J-137: Image Registration Tool for Patient Setup in Korea Heavy Ion Medical Accelerator Center

Purpose: A potential validation tool for compensating patient positioning error was developed using 2D/3D and 3D/3D image registration. Methods: For 2D/3D registration, digitally reconstructed radiography (DRR) and three-dimensional computed tomography (3D-CT) images were applied. The ray-casting algorithm is the most straightforward method for generating DRR. We adopted the traditional ray-casting method, which finds the intersections of a ray with all objects, voxels of the 3D-CT volume in the scene. The similarity between the extracted DRR and orthogonal image was measured by using a normalized mutual information method. Two orthogonal images were acquired from a Cyber-Knife system from the anterior-posterior (AP) and right lateral (RL) views. The 3D-CT and two orthogonal images of an anthropomorphic phantom and head and neck cancer patient were used in this study. For 3D/3D registration, planning CT and in-room CT image were applied. After registration, the translation and rotation factors were calculated to position a couch to be movable in six dimensions. Results: Registration accuracies and average errors of 2.12 mm ± 0.50 mm for transformations and 1.23° ± 0.40° for rotations were acquired by 2D/3D registration using an anthropomorphic Alderson-Rando phantom. In addition, registration accuracies and average errors of 0.90 mm ± 0.30 mm for transformations and 1.00° ± 0.2° for rotations were acquired using CT image sets. Conclusion: We demonstrated that this validation tool could compensate for patient positioning error. In addition, this research could be the fundamental step for compensating patient positioning error at the first Korea heavy-ion medical accelerator treatment center.

60 APPLIED LIFE SCIENCES↗

HPC Usage Behavior Analysis and Performance Estimation with Machine Learning Techniques

Most researchers with little high performance computing (HPC) experience have difficulties productively using the supercomputing resources. To address this issue, we investigated usage behaviors of the world s fastest academic Kraken supercomputer, and built a knowledge-based recommendation system to improve user productivity. Six clustering techniques, along with three cluster validation measures, were implemented to investigate the underlying patterns of usage behaviors. Besides manually defining a category for very large job submissions, six behavior categories were identified, which cleanly separated the data intensive jobs and computational intensive jobs. Then, job statistics of each behavior category were used to develop a knowledge-based recommendation system that can provide users with instructions about choosing appropriate software packages, setting job parameter values, and estimating job queuing time and runtime. Experiments were conducted to evaluate the performance of the proposed recommendation system, which included 127 job submissions by users from different research fields. Great feedback indicated the usefulness of the provided information. The average runtime estimation accuracy of 64.2%, with 28.9% job termination rate, was achieved in the experiments, which almost doubled the average accuracy in the Kraken dataset.

Zhang, Hao↗

Computer-aided Veress needle guidance using endoscopic optical coherence tomography and convolutional neural networks

During laparoscopic surgery, the Veress needle is commonly used in pneumoperitoneum establishment. Precise placement of the Veress needle is still a challenge for the surgeon. In this study, a computer-aided endoscopic optical coherence tomography (OCT) system was developed to effectively and safely guide Veress needle insertion. This endoscopic system was tested by imaging subcutaneous fat, muscle, abdominal space, and the small intestine from swine samples to simulate the surgical process, including the situation with small intestine injury. Each tissue layer was visualized in OCT images with unique features and subsequently used to develop a system for automatic localization of the Veress needle tip by identifying tissue layers (or spaces) and estimating the needle-to-tissue distance. We used convolutional neural networks (CNNs) in automatic tissue classification and distance estimation. In conclusion, the average testing accuracy in tissue classification was 98.53 ± 0.39%, and the average testing relative error in distance estimation reached 4.42 ± 0.56% (36.09 ± 4.92 μm).

59 BASIC BIOLOGICAL SCIENCES↗

Multisensor classification of sedimentary rocks

A comparison is made between linear discriminant analysis and supervised classification results based on signatures from the Landsat TM, the Thermal Infrared Multispectral Scanner (TIMS), and airborne SAR, alone and combined into extended spectral signatures for seven sedimentary rock units exposed on the margin of the Wind River Basin, Wyoming. Results from a linear discriminant analysis showed that training-area classification accuracies based on the multisensor data were improved an average of 15 percent over TM alone, 24 percent over TIMS alone, and 46 percent over SAR alone, with similar improvement resulting when supervised multisensor classification maps were compared to supervised, individual sensor classification maps. When training area signatures were used to map spectrally similar materials in an adjacent area, the average classification accuracy improved 19 percent using the multisensor data over TM alone, 2 percent over TIMS alone, and 11 percent over SAR alone. It is concluded that certain sedimentary lithologies may be accurately mapped using a single sensor, but classification of a variety of rock types can be improved using multisensor data sets that are sensitive to different characteristics such as mineralogy and surface roughness.

Evans, Diane↗

SU-E-J-241: Wavelet-Based Temporal Feature Extraction From DCE-MRI to Identify Sub-Volumes of Low Blood Volume in Head-And-Neck Cancer

Purpose: A previous study showed that large sub-volumes of tumor with low blood volume (BV) (poorly perfused) in head-and-neck (HN) cancers are significantly associated with local-regional failure (LRF) after chemoradiation therapy, and could be targeted with intensified radiation doses. This study aimed to develop an automated and scalable model to extract voxel-wise contrast-enhanced temporal features of dynamic contrastenhanced (DCE) MRI in HN cancers for predicting LRF. Methods: Our model development consists of training and testing stages. The training stage includes preprocessing of individual-voxel DCE curves from tumors for intensity normalization and temporal alignment, temporal feature extraction from the curves, feature selection, and training classifiers. For feature extraction, multiresolution Haar discrete wavelet transformation is applied to each DCE curve to capture temporal contrast-enhanced features. The wavelet coefficients as feature vectors are selected. Support vector machine classifiers are trained to classify tumor voxels having either low or high BV, for which a BV threshold of 7.6% is previously established and used as ground truth. The model is tested by a new dataset. The voxel-wise DCE curves for training and testing were from 14 and 8 patients, respectively. A posterior probability map of the low BV class was created to examine the tumor sub-volume classification. Voxel-wise classification accuracy was computed to evaluate performance of the model. Results: Average classification accuracies were 87.2% for training (10-fold crossvalidation) and 82.5% for testing. The lowest and highest accuracies (patient-wise) were 68.7% and 96.4%, respectively. Posterior probability maps of the low BV class showed the sub-volumes extracted by our model similar to ones defined by the BV maps with most misclassifications occurred near the sub-volume boundaries. Conclusion: This model could be valuable to support adaptive clinical trials with further validation. The framework could be extendable and scalable to extract temporal contrastenhanced features of DCE-MRI in other tumors. We would like to acknowledge NIH for funding support: UO1 CA183848.

60 APPLIED LIFE SCIENCES↗

An Eulerian–Lagrangian Weighted Essentially Nonoscillatory scheme for nonlinear conservation laws

Here, we develop a formally high order Eulerian–Lagrangian Weighted Essentially Nonoscillatory (EL-WENO) finite volume scheme for nonlinear scalar conservation laws that combines ideas of Lagrangian traceline methods with WENO reconstructions. The particles within a grid element are transported in the manner of a standard Eulerian–Lagrangian (or semi-Lagrangian) scheme using a fixed velocity v. A flux correction computation accounts for particles that cross the v-traceline during the time step. If v = 0, the scheme reduces to an almost standard WENO5 scheme. The CFL condition is relaxed when v is chosen to approximate either the characteristic or particle velocity. Excellent numerical results are obtained using relatively long time steps. The v-traceback points can fall arbitrarily within the computational grid, and linear WENO weights may not exist for the point. A general WENO technique is described to reconstruct to any order the integral of a smooth function using averages defined over a general, nonuniform computational grid. Moreover, to high accuracy, local averages can also be reconstructed. By re-averaging the function to a uniform reconstruction grid that includes a point of interest, one can apply a standard WENO reconstruction to obtain a high order point value of the function.

97 MATHEMATICS AND COMPUTING↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

Accurate spatiotemporal predictions of daily stream temperature from statistical models accounting for interactions between climate and landscape

Spatial and temporal patterns in stream temperature are primary factors determining species composition, diversity and productivity in stream ecosystems. The availability of spatially and temporally continuous estimates of stream temperature would improve the ability of biologists to fully explore the effects of stream temperature on biota. Most statistical stream temperature modeling techniques are limited in their ability to account for the influence of variables changing across spatial and temporal gradients. We identified and described important interactions between climate and spatial variables that approximate mechanistic controls on spatiotemporal patterns in stream temperature. With identified relationships we formed models to generate reach-scale basin-wide spatially and temporally continuous predictions of daily mean stream temperature in four Columbia River tributaries watersheds of the Pacific Northwest, USA. Models were validated with a testing dataset composed of completely distinct sites and measurements from different years. While some patterns in residuals remained, testing dataset predictions of selected models demonstrated high accuracy and precision (averaged RMSE for each watershed ranged from 0.85–1.54 °C) and was only 17% higher on average than training dataset prediction error. Aggregating daily predictions to monthly predictions of mean stream temperature reduced prediction error by an average of 23%. The accuracy of predictions was largely consistent across diverse climate years, demonstrating the ability of the models to capture the influences of interannual climatic variability and extend predictions to timeframes with limited temperature logger data. Results suggest that the inclusion of a range of interactions between spatial and climatic variables can approximate dynamic mechanistic controls on stream temperatures.

Siegel, Jared E.↗

Land-Use and Land-Cover Change around Mobile Bay, Alabama from 1974-2008

This document summarizes the major findings of a Gulf of Mexico Application Pilot project led by NASA Stennis Space Center (SSC) in conjunction with a regional collaboration network of the Gulf of Mexico Alliance (GOMA). NASA researchers processed and analyzed multi-temporal Landsat data to assess land-use and land-cover (LULC) changes in the coastal counties of Mobile and Baldwin, AL between 1974 and 2008. Our goal was to create satellite-based LULC data products using methods that could be transferable to other coastal areas of concern within the Gulf of Mexico. The Mobile Bay National Estuary Program (MBNEP) is the primary end-user, however, several other state and local groups may benefit from the project s data products that will be available through NOAA-NCDDC s Regional Ecosystem Data Management program. Mobile Bay is a critical ecologic and economic region in the Gulf of Mexico and to the entire country. Mobile Bay was designated as an estuary of national significance in 1996. This estuary receives the fourth largest freshwater inflow in the United States. It provides vital nursery habitat for commercially and recreationally important fish species. It has exceptional aquatic and terrestrial bio-diversity, however, its estuary health is influenced by changing LULC patterns, such as urbanization. Mobile and Baldwin counties have experienced a population growth of 1.1% and 20.5% from 2000-2006. Urban expansion and population growth are likely to accelerate with the construction and operation of the ThyssenKrupp steel mill in the northeast portion of Mobile County. Land-use and land-cover change can negatively impact Gulf coast water quality and ecological resources. The conversion of forest to urban cover types impacts the carbon cycle and increases the freshwater and sediment in coastal waters. Increased freshwater runoff decreases salinity and increases the turbidity of coastal waters, thus impacting the growth potential of submerged aquatic vegetation (SAV), which is critical nursing ground for many Gulf fish species. A survey of Mobile Bay SAV showed widespread decreases since the 1940s. Prior to our project, coastal environmental managers in Baldwin and Mobile counties needed more understanding of the historical LULC for properly assessing the impacts of urbanization. In particular, more information on the location and extent of changing urbanization LULC patterns was needed to aid LULC planning and to assess predictions of future LULC patterns. Our products will assist the coastal environmental managers and land-use planners in making better community growth planning decisions. Our project also will help to establish a historical baseline of LULC distributions, which is a fundamental need in any stewardship plan. The primary research objective of our project was to produce historic and current geospatial LULC change products across a 34-year time frame. A multi-decadal coastal LULC change product was the major project deliverable. The geographic extent and nature of change was quantified and assessed for the upland herbaceous, barren, open water, urban, upland forest, woody wetland, and non-woody wetlanddominated land cover types. We focused on regional analyses of decadal-scale urban expansion and watershed-scaled analyses of LULC change for multiple areas of concern to the Mobile Bay NEP (Figure A). We used the following dates to derive LULC classification products from Landsat data: 1974, 1979, 1984, 1988, 1991, 1996, 2001, 2005, and 2008. We assessed the accuracy of our products using randomly sampled locations and digital geospatial reference data including field survey data, high resolution orthorectified aerial photography, high resolution multispectral and panchromatic satellite data displays (from QuickBird and Corona sensors), digital elevation model data, and National Wetlands Inventory wetland cover type data. NOAA s Coastal Change Assessment Program s (C-CAP) and National Land Cover Database (NLCD) procts were used for qualitative comparison in assessing map accuracy. We calculated an average overall classification accuracy of 87% with similar overall accuracies for the older (MSS) and newer (TM and ETM) Landsat LULC products.

Ellis, Jean↗

Optimized Hybrid Megavoltage-Kilovoltage Imaging Protocol for Volumetric Prostate Arc Therapy

Purpose: To develop a real-time prostate position monitoring technique for modern arc radiotherapy through novel use of cine-megavoltage (MV) imaging, together with as-needed kilovoltage (kV) imaging. Methods and Materials: We divided the task of monitoring the intrafraction prostate motion into two steps for rotational deliveries: to detect potential target motion beyond a predefined threshold using MV images from different viewing angles by taking advantage of gantry rotation during arc therapy and to verify the displacement and determine whether intervention is needed using fiducial/tumor position information acquired from combined MV-kV imaging (by turning on the kV imager). A Varian Trilogy linear accelerator with an onboard kV imager was used to examine selected typical trajectories using a four-dimensional motion phantom. The performance of the algorithm was evaluated using phantom measurements and computer simulation for 536 Calypso-measured tracks from 17 patients. Results: Fiducial displacement relative to the MV beam was limited to within a range of 3 mm 99.9% of the time with <1 mm accuracy. On average, only {approx}0.5 intervention per arc delivery was needed to achieve this level of accuracy. Compared with other fluoroscopy-based tracking techniques, kV use was significantly reduced to an average of <15 times per arc delivery. Conclusion: By focusing the attention on detecting predefined abnormal motion (i.e., 'failure' detection) and using the inherent mechanism of gantry rotation during arc radiotherapy, the current approach provides high confidence regarding the prostate position in real time without the unwanted overhead of continuous or periodic kV imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗