Endurance testing of a 30-cm Kaufman thruster

Results of a program to demonstrate lifetime capability of a 30-cm Kaufman ion thruster with a 6000 hour endurance test are described. Included in the program are (1) thruster fabrication, (2) design and construction of a test console containing a transistorized high frequency power processor, and control circuits which provide unattended automatic operation of the thruster, and (3) modification of a vacuum facility to incorporate a frozen mercury collector and permit unattended operation. Four tests ranging in duration from 100 to 1100 hours have been completed. These tests and the resulting thruster modifications are described. The status of the endurance test is also presented.

Collett, C. R.↗

One-third selection for matrix-addressing ferroelectrics

Automatic-gain-control (AGC) circuit regulates gain of intermediate frequency and radio-frequency signals over wide dynamic range with high linearity and very low phase shift. Potential application include radio and television receivers, signal distribution systems, and test and measurement instruments.

Tannas, L. E., Jr.↗

RFID in Space: Exploring the Feasibility and Performance of Gen 2 Tags as a Means of Tracking Equipment, Supplies, and Consumable Products in Cargo Transport Bags onboard a Space Vehicle or Habitat

Current inventory management techniques for consumables and supplies aboard space vehicles are burdensome and time consuming. Inventory of food, clothing, and supplies are taken periodically by manually scanning the barcodes on each item. The inaccuracy of reading barcodes and the excessive amount of time it takes for the astronauts to perform this function would be better spent doing scientific experiments. Therefore, there is a need for an alternative method of inventory control by NASA astronauts. Radio Frequency Identification (RFID) is an automatic data capture technology that has potential to create a more effective and user-friendly inventory management system (IMS). In this paper we introduce a Design for Six Sigma Research (DFSS-R) methodology that allows for reliability testing of RFID systems. The research methodology uses a modified sequential design of experiments process to test and evaluate the quality of commercially available RFID technology. The results from the experimentation are compared to the requirements provided by NASA to evaluate the feasibility of using passive Generation 2 RFID technology to improve inventory control aboard crew exploration vehicles.

Jones, Erick C.↗

Pulse-width-modulated attenuator for AGC

Automatic-gain-control (AGC) circuit regulates gain of intermediate-frequency and radio-frequency signals over wide dynamic range with high linearity and very low phase shift. Device has potential uses in radio and television receivers, signal distribution systems, and test and measurement instruments.

Macconnell, J. W.↗

Non-linear generation of acoustic noise in the IAR spacecraft

The requirement to produce high level acoustic noise fields with increasing accuracy in environmental test facilities dictates that a more precise understanding is required of the factors controlling nonlinear noise generation. Details are given of various nonlinear effects found in acoustic performance data taken from the IAR Spacecraft Acoustic Chamber. This type of data has enabled the IAR to test large spacecraft to relatively tight acoustic tolerances over a wide frequency range using manually set controls. An analog random noise automatic control system was available and modified to provide automatic selection of the chamber's spectral sound pressure levels. The automatic control system when used to complete a typical qualification test appeared to equal the accuracy of the manual system and had the added advantage that parallel spectra could be easily achieved during preset tests.

Westley, R.↗

Paralleling of LLC Resonant Converters

The LLC resonant converter is a popular, variable switching frequency DC-DC converter that may be controlled using two methods: charge and frequency control. In this paper, the application of LLC resonant converters to input-parallel, output-parallel system is studied. In this respect, the models of output-port I-V characteristics and small-signal output impedance of the charge controlled LLC converter are proposed. In addition, a mathematical framework is developed for droop-based paralleled DC-DC systems. Here, it distinctly identifies the output DC voltage and circulating current modes of stability, even in systems comprising of non-identical converters.

42 ENGINEERING↗

Minicomputer-controlled frequency generator

Extremely-accurate and low-phase-noise frequency generator varies oscillator frequency as predetermined function of time. System could be used: (a) to automatically vary transmission frequencies in accordance with seasonal and diurnal changes in ionospheric conditions, (b) as automatic tuner for heterodyne receivers, or (c) as control element for phase-locked telemetry receivers.

Winkelstein, R. A.↗

Advanced figure sensor operations and maintenance manual

This manual contains procedures for installing, operating, and maintaining the optical figure sensor and its associated electronic controls. The optical figure sensor, a system of integrated components, comprises: (1) a phase measuring modified interferometer employing a single frequency 6328 A laser, and a Vidissector; (2) a two-axis automatic thermal compensation control mount; (3) a five degree of freedom manual adjustment stand; and (4) a control console. This instrument provides real time output data of optical figure errors for spherical mirrors, and is also capable of measuring aspherical mirrors if a null corrector is added.

Robertson, H. J.↗

High-Frequency ac Power-Distribution System

Loads managed automatically under cycle-by-cycle control. 440-V rms, 20-kHz ac power system developed. System flexible, versatile, and "transparent" to user equipment, while maintaining high efficiency and low weight. Electrical source, from dc to 2,200-Hz ac converted to 440-V rms, 20-kHz, single-phase ac. Power distributed through low-inductance cables. Output power either dc or variable ac. Energy transferred per cycle reduced by factor of 50. Number of parts reduced by factor of about 5 and power loss reduced by two-thirds. Factors result in increased reliability and reduced costs. Used in any power-distribution system requiring high efficiency, high reliability, low weight, and flexibility to handle variety of sources and loads.

Hansen, Irving G.↗

RF processing

The Loran-C radio frequency processing is discussed. A diagram which generally illustrates the automatic gain control is presented. The augmented differentiator for pulse envelopes adapts conventional communications receiver with wideband AM capability to detect pulse signals such as Loran-C. The circuit enhances reception for surveillance and observation of HF over-the-horizon radar signals or others where time difference estimates between pulse returns are of interest. The high resolution VLF spectrum which receives weak VLF signals by using an HP 3581A wave analyzer detecting signals with a very narrow bandwidth of only 3 Hz is also presented.

Burhans, R. W.↗

Power Sharing-Based Framework for Allocating Automatic Generation Control in Distributed Energy Resources: Preprint

The recent proliferation of distributed energy resources (DERs) in the power network along with the retirement of conventional generators has made it challenging to regulate system frequency. In this paper, we present a centralized control framework to leverage the potential of DERs in the distribution network in provisioning secondary frequency control services to the grid. The proposed framework is based on network volt-watt sensitivity analysis and takes into account DER operational and network-imposed constraints to allocate the automatic generation control (AGC) request among the aggregated units. The proposed framework was implemented on the IEEE 8500-node test feeder and results were validated against a standard linear programming-based scheme. Numerical results indicate that the proposed framework can successfully utilize the available power production headroom of the network to meet the AGC request while maintaining nodal voltages within acceptable limits.

distributed energy resources↗

Mitigation of pulsed RFI via automatic gain control

Three automatic gain control (AGC) strategies and their potential capabilities for mitigation of pulsed radio frequency interference (RFI) over a coded, nonlinear channel are examined. The first updates the AGC control voltage once each symbol interval in accordance with a prespecified criterion. The second implementation is designed to first detect high level RFI and then appropriately update its gain. The final implementation is a wideband device which updates its gain once each symbol interval by reducing the gain in direct proportion to a suitable power measurement. Computed results treat pulsed noise and pulsed CW RFI and compare performances in terms of bit error rate (BER) at the output of a Viterbi decoder.

Chang, R. W.-S.↗

Design concepts using ring lasers for frequency stabilization

Laser frequency stabilization methods are based on a frequency discriminant which generates an unambiguous deviation signal used for automatic stabilization. Closed-loop control stabilizes cavity length at a null point. Some systems have a stabilized ring laser using a piezoelectric dither and others use a Doppler gain tube.

Mocker, H.↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automatic Locking of Laser Frequency to an Absorption Peak

An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that constantly adjusts the frequency in an effort to drive the error to zero. When the laser frequency deviates from the midpeak value but remains within the locking range, the magnitude and sign of the error signal indicate the amount of detuning and the control circuitry adjusts the frequency by what it estimates to be the negative of this amount in an effort to bring the error to zero.

Koch, Grady J.↗