Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Active Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Geomagnetic Storm Effects on Ionospheric Irregularities: Insights from SuperDARN, Madrigal GPS TEC, and ISR Data [Slides]

Geomagnetic disturbances trigger an influx of electrons from the magnetosphere, leading to an increase electron density (even in lower altitudes), amplified ionospheric currents, and subsequently, increased conductance. A surge in the AE index, indicating heightened auroral currents, correlates with a rise in precipitated charged particles, including electrons, into the polar ionosphere. This correlation is detectable through increased parameter values measured by SuperDARN. The downward flow of electron density towards lower altitudes, as observed in PFISR data, potentially obstructs the transmission frequency from radar stations passing through the PFISR location (just like we saw in the KOD station). During the geomagnetic storm, there is increased backscatter power (increased amount of ionospheric irregularities), and the plasma flow draws closer to the radar, suggesting a possible southward shift in the auroral oval as a result of the heightened auroral activity. Increased geomagnetic activity correlates with an elevation in average TEC and induces the occurrence of SED (Storm Enhanced Density).

58 GEOSCIENCES↗

A Voltage Inference Framework for Real-Time Observability in Active Distribution Grids

Active distribution grids are gaining traction to meet the growing environmental, socio-economic, and sustainability targets. Various advanced smart grid technologies facilitate the integration of Distributed Energy Resources (DERs) by supporting the bi-directional power flow. The limited observability of distribution grids, primarily related to their location at the very edge of power system infrastructure, brings challenges to optimal grid management. Moreover, only a limited number of measurements at regular intervals are usually available. This paper presents a novel inference framework, referred to as “Voltage Inference”, to overcome the observability issues. The proposed framework employs a prediction step based on the Multivariate Taylor series approximation, followed by a corrector step that minimizes the estimation error to infer the otherwise unknown voltages from the available measurements. Furthermore, numerical results on the IEEE 13-bus test feeder validate the accuracy and computational performance of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probabilistic Physics-Informed Graph Convolutional Network for Active Distribution System Voltage Prediction

Here this letter proposes a novel data-driven probabilistic physics-informed graph convolutional network (GCN) for active distribution system voltage prediction with PVs and EVs. It leverages both measurements and network topology to accurately and efficiently predict node voltages without the need for an accurate distribution system power flow model. The dropout-enabled Bayesian inference is developed to achieve uncertainty quantification of the voltage prediction. Thanks to the network model embedding, it also has robustness against topology changes, a key difference with existing machine learning-based approaches. Comparison results with other state-of-the-art machine learning methods on a realistic 759-node distribution system demonstrate that the proposed method can achieve better accuracy and robustness under different scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Design Evaluation of a Next-Generation High-Temperature Particle Receiver for Concentrating Solar Thermal Applications

High-temperature particle receivers are being developed to achieve temperatures in excess of 700 °C for advanced power cycles and solar thermochemical processes. This paper describes designs and features of a falling particle receiver system that has been evaluated and tested at the National Solar Thermal Test Facility at Sandia National Laboratories. These advanced designs are intended to reduce heat losses and increase the thermal efficiency. Novel features include aperture covers, active air flow, particle flow obstructions, and optimized receiver shapes that minimize advective heat losses, increase particle curtain opacity and uniformity, and reduce cavity wall temperatures. Control systems are implemented in recent on-sun tests to maintain a desired particle outlet temperature using an automated closed-loop proportional–integral–derivative controller. These tests demonstrate the ability to achieve and maintain particle outlet temperatures approaching 800 °C with efficiencies between 60 and 90%, depending on incident power, mass flow, and environmental conditions. Lessons learned regarding the testing of design features and overall receiver operation are also presented.

Mills, Brantley H.↗

Code Benchmark of the HTTF Pressurized Conduction Cooldown Test Using SAM

The High Temperature Test Facility (HTTF) at Oregon State University is an integral system test facility to simulate postulated reactor transients of prismatic high-temperature gas-cooled reactors(HTGRs). A series of test campaigns was launched, providing abundant test data that could be used to benchmark reactor system analysis codes like the System Analysis Module (SAM). In this study, a SAM model of the facility is developed based on the two-dimensional (2D) ring model approach. All components including the ceramic matrix, graphite heaters, helium coolant channels, core barrel, upcomer, pressure vessel, and reactor cavity cooling system are modeled as concentric cylindrical rings. The model is used to simulate one of the benchmark problems-Pressurized Conduction Cooldown (PCC)-within the scope of the Organisation for Economic Co-operation and Development Nuclear Energy Agency International HTTF Benchmark. The simulations consist of two parts. In the first part, operating and boundary conditions as well as thermophysical properties of materials are specified for the benchmark problem. In this work, results from the first part will be used in code-to-code comparison. In the second part, the SAM model is used to simulate Test PG-27, which is the first PCC test carried out in the HTTF, with only two of the ten heater banks activated. The results in the second part are used for code-to-data comparison. Because the helium coolant flow rate is not measured in this facility, it is estimated using the input power and inlet/outlet coolant temperatures. Additionally, radial heat flow in the ceramic blocks is complicated by hundreds of cylindrical coolant channels and heater rods embedded in them. As such, it is necessary to deduce an effective thermal conductivity for the ceramic to analyze the core thermal behavior. SAM predictions of the helium coolant and ceramic temperatures are compared with test data measured in three equivalent sectors. Overall, the SAM results agree reasonably well with test data within the variation of data among the three sectors, which demonstrates SAM's capability in capturing transient effects in HTGR using the simplified 2D ring model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Congestion Management Solutions for Enhanced Distribution System Operations with Aggregated Distribution Grid Resources Providing Grid Services and Market Participation

Microgrids and other aggregations of distribution grid resources (DGRs) are poised to actively participate in electricity markets and provide essential grid services in the coming years. In fact, DGRs already play such a role through behind-the-meter (BTM) demand response programs and small-scale BTM dispatchable generation initiatives. At the same time, the rapid growth of artificial intelligence (AI) and cryptocurrency datacenters imposes significant, often unpredictable, demands on the power distribution system. Aggregated DGRs can serve as flexible resources that help mitigate these pressures by using available transmission and distribution capacity more efficiently, supporting resource adequacy and other reliability services, and providing bridge strategies while long-term transmission infrastructure is being developed. The impacts this activity will have on distribution networks are not fully understood and could present significant challenges for distribution utilities due to capacity constraints and the need for congestion management. Technical issues include reverse power flow, variability and possible degradation of equipment integrity, voltage violations, and customer power quality concerns. These issues will likely intensify as electricity market operators across the United States implement Federal Energy Regulatory Commission Order 2222 over the next few years.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Methodology for Robust Load Reduction in Wind Turbine Blades Using Flow Control Devices

Decades of wind turbine research, development and installation have demonstrated reductions in levelized cost of energy (LCOE) resulting from turbines with larger rotor diameters and increased hub heights. Further reductions in LCOE by up-scaling turbine size can be challenged by practical limitations such as the square-cube law: where the power scales with the square of the blade length and the added mass scales with the volume (the cube). Active blade load control can disrupt this trend, allowing longer blades with less mass. This paper presents the details of the development of a robust load control system to reduce blade fatigue loads. The control system, which we coined sectional lift control or SLC, uses a lift actuator model to emulate an active flow control device. The main contributions of this paper are: (1) Methodology for SLC design to reduce dynamic blade root moments in a neighborhood of the rotor angular frequency (1P). (2) Analysis and numerical evidence supporting the use of a single robust SLC for all wind speeds, without the need for scheduling on wind speed or readily available measurements such as collective pitch or generator angular speed. (3) Intuition and numerical evidence to demonstrate that the SLC and the turbine controller do not interact. (4) Evaluation of the SLC using a full suite of fatigue and turbine performance metrics.

17 WIND ENERGY↗

Stabilization and control of persistent current magnets using variable inductance

Ultra-stable, tunable magnetic fields are desirable for a wide range of applications in medical imaging, electron microscopy, quantum science, and atomic physics. Superconducting magnets operated in persistent current mode, with device current flowing in a closed superconducting loop disconnected from a power source, are a common approach for applications with the most stringent requirements on temporal field stability. In this work, we present a method for active control of this persistent current by means of dynamic inductance change within the superconducting circuit. For a first realization of this general technique, we consider a variable superconducting inductor placed in series with the main magnet. The inductor acts as a dynamic flux storage device capable of transferring flux to or from the main magnet through inductance change. This allows for fine and fast adjustments of the persistent current without the use of thermal switches that limit the speed and accuracy of many present-day methods. With first experiments employing this technique, we demonstrate stabilization of a 1.95 T Nb–Ti round lens for electron microscopy against decay resulting from residual losses in the superconducting circuit, and more generally show flexibility for precise control over the magnitude and waveform of the persistent current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling the effects of active wake mixing on wake behavior through large-scale coherent structures

The use of active wake mixing (AWM) to mitigate downstream turbine wakes has created new opportunities for reducing power losses in wind farms. However, many current analytical or semi-empirical wake models do not capture the flow instabilities that are excited through the blade pitch actuation. In this work, we develop a framework, which accounts for the impacts of the large-scale coherent structures and turbulence on the mean flow, for modeling AWM. The framework uses a triple-decomposition approach for the unsteady flow field and models the mean flow and fine-scale turbulence with a parabolized Reynolds-averaged Navier–Stokes (RANS) system. The wave components are modeled using a simplified spatial linear stability formulation that captures the growth and evolution of the coherent structures. Comparisons with high-fidelity large eddy simulations (LESs) of the turbine wakes showed that this framework was able to capture the additional wake mixing and faster wake recovery in the far-wake regions for both the pulse and helix AWM strategies with minimal computational expense. In the near-wake region, some differences are observed in both the RANS velocity profiles and initial growth of the large-scale structures, which may be due to some simplifying assumptions used in the model.

17 WIND ENERGY↗

High Performance Flow Battery with Inexpensive Inorganic Reactants: DAYS Program (Final Technical Report)

RTRC’s DAYS projects focused on new flow battery (FB) chemistries for long duration energy storage: one that pairs aqueous polysulfide and manganese active materials in strongly alkaline electrolytes (S/Mn); another explores ligand-modified metal (LMM) chemistries in moderate pH electrolyte conditions. The S/Mn chemistry met durability targets by running for over 500 cycles and 1000 hours. Combined with this durability, power densities of up to 60 mW/cm2 at 80% round-trip efficiency, and exceptionally low-cost S and Mn active materials, the S/Mn FB offers a pathway to meeting the <5¢/kW-hr levelized cost of storage (LCOS) target first proposed by the DAYS Program and accepted by the DOE Energy Storage Grand Challenge. The LMM chemistry made impressive progress as well, including durability tests that retained performance over 600 hours of cycling. Cell optimization allowed this chemistry to operate as high as 500 mW/cm2 at 80% round-trip efficiency, nearly 10x the power density of S/Mn and comparable to the power density achieved in RTRC’s flow battery stacks using acidic vanadium battery solutions. This enabled the LMM chemistry to also offer a pathway to the <5¢/kW-hr LCOS DAYS and DOE targets. The promising results from the LMM chemistry have led to a recent DOE AMO award to advance the technology to a 5 kW, 20 kW-hr prototype.

25 ENERGY STORAGE↗

Hubble Space Telescope Observations within the Sphere of Influence of the Powerful Supermassive Black Hole in PKS 0745-191

We present Space Telescope Imaging Spectrograph observations from the Hubble Space Telescope of the supermassive black hole (SMBH) at the center of PKS 0745-191, a brightest cluster galaxy (BCG) undergoing powerful radio-mode active galactic nucleus (AGN) feedback (P cav ~ 5 × 10 45 erg s -1 ). These high-resolution data offer the first spatially resolved map of gas dynamics within an SMBH's sphere of influence under such powerful feedback. Our results reveal the presence of highly chaotic, nondrotational ionized gas flows on subkiloparsec scales, in contrast to the more coherent flows observed on larger scales. While radio-mode feedback effectively thermalizes hot gas in galaxy clusters on kiloparsec scales, within the core, the hot gas flow may decouple, leading to a reduction in angular momentum and supplying ionized gas through cooling, which could enhance accretion onto the SMBH. This process could, in turn, lead to a self-regulating feedback loop. Compared to other BCGs with weaker radio-mode feedback, where rotation is more stable, intense feedback may lead to more chaotic flows, indicating a stronger coupling between jet activity and gas dynamics. Additionally, we observe a sharp increase in velocity dispersion near the nucleus, consistent with a very massive M BH ~ 1.5 × 10 10 M ⊙ SMBH. The density profile of the ionized gas is also notably flat, paralleling the profiles observed in X-ray gas around galaxies where the Bondi radius is resolved. These results provide valuable insights into the complex mechanisms driving galaxy evolution, highlighting the intricate relationship between SMBH fueling and AGN feedback within the host galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

The role of collective elasticity on activated structural relaxation, yielding, and steady state flow in hard sphere fluids and colloidal suspensions under strong deformation

In this work, we theoretically study the effect of external deformation on activated structural relaxation and aspects of the nonlinear mechanical response of glassy hard sphere fluids in the context of elastically collective nonlinear Langevin equation theory. This microscopic force-based approach describes activated relaxation as a coupled local–nonlocal event involving caging and longer range collective elasticity, with the latter becoming more important and ultimately dominant with increasing packing fraction under equilibrium conditions. The central new question we address is how this physical picture of activated relaxation, and the relative importance of local caging vs collective elasticity physics, depends on external deformation. Theoretical predictions are presented for deformation-induced enhancement of mobility, the onset of relaxation speed up at remarkably low values of stress, strain, or shear rate, apparent power law thinning of the steady state structural relaxation time and viscosity, a non-vanishing activation barrier in the shear thinning regime, an apparent Herschel–Bulkley form of the rate dependence of the steady state shear stress, exponential growth of different measures of a dynamic yield or flow stress with the packing fraction, and reduced fragility and dynamic heterogeneity under deformation. The results are contrasted with experiments and simulations, and qualitative or better agreement is found. An overarching conclusion is that deformation strongly reduces the importance of longer range collective elastic effects relative to the local caging aspect for most, but not all, physical questions, with deformation-dependent fragility and dynamic heterogeneity phenomena being qualitatively sensitive to collective elasticity. Overall, nonlinear rheology is predicted to be a more local problem than quiescent structural relaxation, albeit with deformation-modified activated processes still important.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Catalight─An Open-Source Automated Photocatalytic Reactor Package Illustrated through Plasmonic Acetylene Hydrogenation

An open-source and modular Python package, Catalight, is developed and demonstrated to automate (photo)catalysis measurements. (Photo)catalysis experiments require studying several parameters to evaluate performance, including the temperature, gas flow rate and composition, illumination power, and spectral profile. Catalight orchestrates measurements over this complicated parameter space and systematically stores, analyzes, and visualizes the results. To showcase the capabilities of Catalight, we perform an automated apparent activation barrier measurement of acetylene hydrogenation over a plasmonic AuPd catalyst on an Al 2 O 3 support, simultaneously varying laser power, wavelength, and temperature in a multiday experiment controlled by a simple Python script. Our chemical results unexpectedly show an increased activation barrier upon light excitation, contrary to previous findings for other plasmonic reactions and catalysts. We show that the reaction rate order with respect to both acetylene and hydrogen remains unchanged upon illumination, suggesting that molecular surface coverage is not changed by light. By analyzing the inhomogeneity of the laser-induced heating, we attribute these results to a partial photothermal effect combined with a photochemical/hot electron-driven mechanism. In conclusion, our findings highlight the capabilities of a new experiment automation tool; explore the photocatalytic mechanism for an industrially relevant reaction; and identify systematic sources of error in canonical photocatalysis experimental procedures.

Catalysts↗

Solidification cracking of laser melted commercial-purity tungsten

The high melting temperature of tungsten (W) makes it an attractive candidate for energy generation applications; however, its use is limited by its poor ductility at low temperatures. This limitation affects even melt-based additive manufacturing (AM) processes such as laser powder bed fusion (PBF-LB), with as-fabricated pure W exhibiting both longitudinal and transverse cracks. Metallurgical and processing factors that affect these cracks are still being explored. This work utilizes powderless single-tracks on pure W plates made over a range of power and velocity combinations in three unique PBF-LB setups: one with flowing argon, one with continuous vacuum, and an in situ high-speed synchrotron X-ray radiography setup. Each had different oxygen activities in their build environments. Longitudinal cracks with oxides appearing to exude from the crack were found for tracks deposited in a build environment with argon shield gas, while no such cracks were observed for builds conducted in vacuum. A calculation showed that direct oxygen ingress into the melt pool from the build environment is negligible when argon shield gas is present. Thus, incorporation of spatter is a likely mechanism for oxygen ingress into the melt pool. Radiography showed extensive keyholing, spatter generation, and crack formation at keyhole porosity. A heat transfer calculation showed the crack formation time was consistent with cooling below its ductile-to-brittle transition (DBT) temperature. This work identifies solidification cracking as a feasible mechanism in pure W beyond the well-known DBT related cracking.

Materials science↗