Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated Stress Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Visualization, understanding, and mitigation of process-induced-membrane irregularities in gas diffusion electrode-based polymer electrolyte membrane fuel cells

Polymer electrolyte membrane fuel cells (PEMFC) show substantial promise for their application in electric vehicles. For large-scale manufacturing of PEMFCs, roll-to-roll coated gas-diffusion-electrodes (GDE) offer certain advantages over other production pathways. Procedures including hot pressing and coating an ionomer overlayer may be necessary for this manufacturing pathway to enable a suitable catalyst layer/membrane interface. The same procedures may potentially introduce membrane irregularities, especially when thin membranes are used. Limited understanding exists regarding if and to what extent such irregularities impact PEMFC performance and lifetime, and therefore be considered defects. In this study, NREL's customized fuel cell hardware that enables quasi in-situ infrared (IR) thermography studies was utilized to visualize spatial hydrogen crossover and identify membrane irregularities that originated from the GDE-based MEA fabrication process. The structure of these membrane irregularities was investigated by scanning electron microscopy (SEM) and its impact on initial H2/air performance was determined. Accelerated stress testing (AST) revealed that these irregularities develop into failure point locations. These results were validated across many MEAs with identified process-induced membrane irregularities. By selecting specific gas diffusion media properties and by fine tuning the MEA hot pressing parameters, the formation of such membrane irregularities was mitigated.

08 HYDROGEN↗

Nanochannel electrodes facilitating interfacial transport for PEM water electrolysis

Proton-exchange membrane water electrolyzers (PEMWEs) are a promising technology for green hydrogen production; however, interfacial transport behaviors are poorly understood, hindering device performance and longevity. Here, we first utilized finite-gap electrolyzer to demonstrate the possibility of proton transfer through water in PEMWEs. The measured high-frequency resistances (HFRs) exhibit a linear trend with increasing gap distance, where extrapolation shows a lower value compared with HFRs in regular zero-gap electrolyzers, indicating that ohmic resistance could be further reduced. We introduce nanochannels to facilitate mass transport, as evidenced by both liquid-fed and vapor-fed electrolysis. Nanochannel electrodes achieve a voltage reduction of 190 mV at 9 A·cm –2 compared with the Ir-PTEs without nanochannels. Furthermore, nanochannel electrodes show negligible degradation through 100,000 accelerated-stress tests and over 2,000 h of operation at 1.8 A·cm –2 with a decay rate of 11.66 μV·h –1 . These results provide new insights into localized transport dynamics for PEMWEs and highlight the significance of interfacial engineering for electrochemical devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phosphonic-Acid-Reinforced Polymer Hole Transport Layers for Deployable p-i-n Perovskite Photovoltaics

The long-term durability prospects of halide perovskite solar cells are rapidly improving; however, the interface between the hole transport layer (HTL) and the perovskite remains a source of degradation. Alone, polymer- or carbazole-based HTLs suffer from incomplete coverage of the underlying indium tin oxide glass, leading to degradation and compromised performance. Here, we show a multi-HTL approach whereby a polymer HTL is reinforced using a phosphonic acid modification leading to better protection of the buried perovskite interface and more columnar growth of perovskite film, resulting in an ~40-mV open-circuit voltage (VOC) improvement indicative of suppressed interfacial recombination across multiple p-i-n device architectures. Solar cells with this reinforced HTL show higher tolerance to several accelerated stress tests. We report, among the best durabilities for unencapsulated cells, a T90 ~3,000 h (T80 ~5,900 h) at 65 degrees C under continuous 1.2 sun AM 1.5G illumination and maximum power point tracking, representing a nearly 4-fold increase compared with [2-(9H-carbazol-9-yl)ethyl]phosphonic acid (2PACz)-only devices. Furthermore, we deployed a device with this reinforced HTL on a cube satellite, with long-duration operational space testing results exceeding T80 for the complete mission duration of ~100 days in low Earth orbit.

14 SOLAR ENERGY↗

Proton Exchange Membrane (PEM) Water Electrolysis: Cell-Level Considerations for Gigawatt-Scale Deployment

Hydrogen produced with no greenhouse gas emissions is termed “green hydrogen” and will be essential to reaching decarbonization targets set forth by nearly every country as per the Paris Agreement. Proton exchange membrane water electrolyzers (PEMWEs) are expected to contribute substantially to the green hydrogen market. However, PEMWE market penetration is insignificant, accounting for less than a gigawatt of global capacity. Achieving substantive decarbonization via green hydrogen will require PEMWEs to reach capacities of hundreds of gigawatts by 2030. This paper serves as an overarching roadmap for cell-level improvements necessary for gigawatt-scale PEMWE deployment, with insights from three well-established hydrogen technology companies included. Analyses will be presented for economies of scale, renewable energy prices, government policies, accelerated stress tests, and component-specific improvements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverse Consequences of the SnO 2 Protection Layers on Pt/C Catalysts in Proton-Exchange Membrane Fuel Cells

Proton-exchange membrane fuel cells (PEMFCs) are promising energy-conversion systems, offering an appealing blend of high energy efficiency and low environmental impact. However, carbon corrosion of PEMFCs is known to significantly degrade their performance, remaining a critical challenge to overcome. In this study, we applied a Nb-doped SnO 2 (Nb-SnO 2 ) nanoparticle coating on Pt/C catalysts as a protective layer, with the Sn/C ratio in the precursors varying from 0.25:1 to 2.0:1. Contradictory behaviors of the coated Pt/C catalysts were observed at different Sn/C ratios. The Sn/C = 1.0 sample exhibited improved electrochemically active surface area retention after 500 cycles of accelerated stress testing (AST) but with more significant polarization and resistance increase observed in the polarization curves. In addition, agglomeration of Nb-SnO 2 particles was observed at a higher Sn/C ratio in the AST of a membrane electrode assembly, with less shrinkage of the total thickness of the Nb-SnO 2 -coated Pt/C electrode. We speculate that formation of Nb-SnO 2 agglomerates occurs once the protective layer is broken down or the unprotected carbon surface is corroded and that these Nb-SnO 2 agglomerates increase the tortuosity of the electron pathways and significantly increase the cell polarization.

30 DIRECT ENERGY CONVERSION↗

Electrochemical Evolution of Fuel Cell Platinum Nanocatalysts on Carbon Nanotubes at the Atomic Scale

The evolution of Pt nanoparticles supported on carbon nanotubes is analyzed before and after electrochemical potential cycling, using identical location aberration-corrected transmission electron microscopy, for applications in proton exchange membrane fuel cells. The work is focused on the half-cell accelerated stress test protocol of potential cycles ranging between 1.0 and 1.5 V RHE to represent the start-up/shutdown settings of a fuel cell vehicle. The research work reveals that particle migration and coalescence are key mechanisms for a reduction in the Pt nanoparticle surface area at the early stages of potential cycling. Further, the mechanism for particle movement and coalescence is attributed to carbon corrosion, catalyzed either by Pt or by bulk corrosion of the carbon nanotubes. Carbon corrosion results in the appearance of carbon vacancies at the carbon nanotube/Pt nanoparticle interface during cycling, as well as the formation of edge and surface defects. During cycling, the concentration of the dissoluble Pt increases. As soon as a significant amount is reached, subnanometer/atomic clusters emerge on the carbon nanotube support, which can move and coalesce, or redeposit on the surface of larger particles through Ostwald ripening.

25 ENERGY STORAGE↗

Recreating Fuel Cell Catalyst Degradation in Aqueous Environments for Identical-Location Scanning Transmission Electron Microscopy Studies

The recent surge in interest of proton exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles increases the demand on the durability of oxygen reduction reaction electrocatalysts used in the fuel cell cathode. This prioritizes efforts aimed at understanding and subsequently controlling catalyst degradation. Identical-location scanning transmission electron microscopy (IL-STEM) is a powerful method that enables precise characterization of degradation processes in individual catalyst nanoparticles across various stages of cycling. Recreating the degradation processes that occur in PEMFC membrane electrode assemblies (MEAs) within the aqueous cell used for IL-STEM experiments is vital for generating an accurate understanding of these processes. In this work, we investigate the type and degree of catalyst degradation achieved by cycling in an aqueous cell compared to a PEMFC MEA. While significant degradation is observed in IL-STEM experiments performed on a traditional Pt catalyst using the standard accelerated stress test potential window (0.6-0.95 VRHE), degradation of a PtCo catalyst designed for heavy-duty vehicle use is very limited compared to that observed in MEAs. We therefore explore various experimental parameters such as temperature, acid type, acid concentration, ionomer content, and potential window to identify conditions that reproduce the degradation observed in MEAs. We find that by extending the cycling potential window to 0.4-1.0 V RHE in an electrolyte containing Pt ions, the degraded particle size distribution and alloy composition better match that observed in MEAs. In particular, these conditions increase the relative contribution of Ostwald ripening, which appears to play a more significant role in the degradation of larger alloy particles supported on high-surface-area carbons than coalescence. Results from this work highlight the potential for discrepancies between ex situ aqueous experiments and MEA tests. While different catalysts may require a unique modification to the AST protocol, strategies provided in this work enable future in situ and identical-location experiments that will play an important role in the development of robust catalysts for heavy-duty vehicle applications.

30 DIRECT ENERGY CONVERSION↗

Pt Nanoparticles on Atomic-Metal-Rich Carbon for Heavy-Duty Fuel Cell Catalysts: Durability Enhancement and Degradation Behavior in Membrane Electrode Assemblies

Proton exchange membrane fuel cells (PEMFCs) are a promising zero-emission power source for heavy-duty vehicles (HDVs). However, long-term durability of up to 25,000 h is challenging because current carbon support, catalyst, membrane, and ionomer developed for traditional light-duty vehicles cannot meet the stringent requirement. Therefore, understanding catalyst degradation mechanisms under the HDV condition is crucial for rationally designing highly active and durable platinum group metal (PGM) catalysts for high-performance membrane electrode assemblies (MEAs). Herein, we report a PGM catalyst consisting of platinum nanoparticles with a high content (40 wt %) on atomic-metal-site (e.g., MnN 4 )-rich carbon support. MEAs with the Pt (40 wt %)/Mn–N–C cathode catalyst achieved significantly enhanced performance and durability, generating 1.41 A cm –2 at 0.7 V under HDV conditions (0.25 mgPt cm –2 and 250 kPa abs pressure) and retaining 1.20 A cm –2 after an extended and accelerated stress test up to 150,000 voltage cycles. Electron microscopy studies indicate that most fine Pt nanoparticles are retained on or/and in the carbon support covered with the ionomer throughout the catalyst layer at the end of life. During the long-term stability test, the observed electrochemical active surface area reduction and performance loss primarily result from Pt depletion in the catalyst layer due to Pt dissolution and redeposition at the interface of the cathode and membrane. Importantly, the first-principle density functional theory calculations further reveal a support entrapment effect of the Mn–N–C, in which the MnN 4 site can specifically adsorb the Pt atom and further retard the Pt dissolution and migration, therefore enhancing long-term MEA durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the Stability of Manganese Chromium Antimonate Electrocatalysts through Multimodal In Situ and Operando Measurements

Herein, we utilize an on-line electrochemical flow cell coupled with an inductively coupled plasma-mass spectrometer (ICP-MS) to characterize the impact of composition and reactant gas on the multielement dissolution of Mn(-Cr)-Sb-O electrocatalysts. Compared to Mn 2 O 3 and Cr 2 O 3 oxides, we find that the antimonate framework stabilizes Mn at OER potentials and Cr at both ORR and OER potentials. Furthermore, dissolution of Mn and Cr from Mn(-Cr)-Sb-O is found to be driven by ORR reaction rate, with minimal dissolution under N 2 . We observe preferential dissolution of Cr totaling 13% over 10 minutes at 0.3, 0.6, and 0.9 V vs RHE, with only 1.5% loss of Mn, indicating an enrichment of Mn at the surface of the particles. Despite this asymmetric dissolution, in situ X-ray absorption spectroscopy (XAS) showed no measurable changes in the Mn K-edge at comparable potentials. This lack of change could suggest that modification to the Mn oxidation state in the surface layer is too small or that layer is too thin to be measured with the bulk XAS measurement. Lastly, on-line ICP-MS was used to assess the effects of applied potential, scan rate, and current of Mn-Cr-Sb-O during cyclic voltammetry and accelerated stress tests. With this deeper understanding of the interplay between oxygen reduction and dissolution, testing procedures were identified to maximize both activity and stability. This work highlights the use of multi-modal in situ characterization techniques in tandem to build a more complete model of stability and develop protocols for optimizing catalyst performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regulating Catalytic Properties and Thermal Stability of Pt and PtCo Intermetallic Fuel-Cell Catalysts via Strong Coupling Effects between Single-Metal Site-Rich Carbon and Pt

Developing low platinum-group-metal (PGM) catalysts for the oxygen reduction reaction (ORR) in proton-exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles (HDVs) remains a great challenge due to the highly demanded power density and long-term durability. Here, this work explores the possible synergistic effect between single Mn site-rich carbon (Mn SA -NC) and Pt nanoparticles, aiming to improve intrinsic activity and stability of PGM catalysts. Density functional theory (DFT) calculations predicted a strong coupling effect between Pt and MnN 4 sites in the carbon support, strengthening their interactions to immobilize Pt nanoparticles during the ORR. The adjacent MnN 4 sites weaken oxygen adsorption at Pt to enhance intrinsic activity. Well-dispersed Pt (2.1 nm) and ordered L1 2 -Pt 3 Co nanoparticles (3.3 nm) were retained on the Mn SA -NC support after indispensable high-temperature annealing up to 800 °C, suggesting enhanced thermal stability. Both PGM catalysts were thoroughly studied in membrane electrode assemblies (MEAs), showing compelling performance and durability. The Pt@Mn SA -NC catalyst achieved a mass activity (MA) of 0.63 A mg Pt –1 at 0.9 V iR-free and maintained 78% of its initial performance after a 30,000-cycle accelerated stress test (AST). The L1 2 -Pt 3 Co@Mn SA -NC catalyst accomplished a much higher MA of 0.91 A mg Pt –1 and a current density of 1.63 A cm –2 at 0.7 V under traditional light-duty vehicle (LDV) H 2 –air conditions (150 kPa abs and 0.10 mg Pt cm –2 ). Furthermore, the same catalyst in an HDV MEA (250 kPa abs and 0.20 mg Pt cm –2 ) delivered 1.75 A cm –2 at 0.7 V, only losing 18% performance after 90,000 cycles of the AST, demonstrating great potential to meet the DOE targets.

25 ENERGY STORAGE↗

Electrospun Ti–Zr Oxide Heterostructures Enable Strongly Anchored Ultralow-Ir Anodes for Durable Acidic Oxygen Evolution

Proton-exchange-membrane water electrolysis (PEMWE) requires acidic oxygen-evolution-reaction (OER) anodes that combine high activity, high durability, and low Ir loading. Here, we report a Ti-Zr composite electrospun oxide (ESO) nanorod support that enables ultralow-Ir anodes for high-performance PEMWE. Zr-containing Ti oxide heterostructures stabilize anatase-rich TiO2, tune the local oxygen-coordination environment, and strengthen interfacial anchoring of IrOx under acidic anodic conditions. The electrospun nanorod network further creates an open, mechanically coherent catalyst layer that improves Ir utilization, ionomer penetration, and mass transport. At an anode loading of 0.2 mgIr cm-2, the optimized Ir/TiZr20-ESO anode delivers a PEMWE mass activity of 0.99 A mgIr-1 at 1.45 V, 28.3 and 43.0 times higher than commercial Ir black and commercial IrO2/TiO2, respectively. The same anode reaches 3.0 and 4.0 A cm-2 at 1.75 and 1.83 V, respectively, and sustains 2000 h operation at 2.0 A cm-2. Also, accelerated stress tests up to 525 hours over 31,500 cycles confirm promising long-term durability, with an insignificant performance decay of 0.4 μV per cycle. Density functional theory indicates that the Ti-Zr oxide heterostructure suppresses Ti demetallation and strengthens IrO2 interfacial binding, rationalizing the improved high-current-density stability.

25 ENERGY STORAGE↗

Ionomer-free and recyclable porous-transport electrode for high-performing proton-exchange-membrane water electrolysis

Abstract Clean hydrogen production requires large-scale deployment of water-electrolysis technologies, particularly proton-exchange-membrane water electrolyzers (PEMWEs). However, as iridium-based electrocatalysts remain the only practical option for PEMWEs, their low abundance will become a bottleneck for a sustainable hydrogen economy. Herein, we propose high-performing and durable ionomer-free porous transport electrodes (PTEs) with facile recycling features enabling Ir thrifting and reclamation. The ionomer-free porous transport electrodes offer a practical pathway to investigate the role of ionomer in the catalyst layer and, from microelectrode measurements, point to an ionomer poisoning effect for the oxygen evolution reaction. The ionomer-free porous transport electrodes demonstrate a voltage reduction of > 600 mV compared to conventional ionomer-coated porous transport electrodes at 1.8 A cm −2 and <0.1 mg Ir cm −2 , and a voltage degradation of 29 mV at average rate of 0.58 mV per 1000-cycles after 50k cycles of accelerated-stress tests at 4 A cm −2 . Moreover, the ionomer-free feature enables facile recycling of multiple components of PEMWEs, which is critical to a circular clean hydrogen economy.

08 HYDROGEN↗

Atomically dispersed iron sites with a nitrogen–carbon coating as highly active and durable oxygen reduction catalysts for fuel cells

Nitrogen-coordinated single atom iron sites (FeN 4 ) embedded in carbon (Fe–N–C) are the most active platinum group metal-free oxygen reduction catalysts for proton-exchange membrane fuel cells. Still, current Fe–N–C catalysts lack sufficient long-term durability and are not yet viable for practical applications. Here we report a highly durable and active Fe–N–C catalyst synthesized using heat treatment with ammonia chloride followed by high-temperature deposition of a thin layer of nitrogen-doped carbon on the catalyst surface. We propose that catalyst stability is improved by converting defect-rich pyrrolic N-coordinated FeN 4 sites into highly stable pyridinic N-coordinated FeN 4 sites. The stability enhancement is demonstrated in membrane electrode assemblies using accelerated stress testing and a long-term steady-state test (>300 h at 0.67 V), approaching a typical Pt/C cathode (0.1 mg Pt cm -2 ). The encouraging stability improvement represents a critical step in developing viable Fe–N–C catalysts to overcome the cost barriers of hydrogen fuel cells for numerous applications.

08 HYDROGEN↗

Regulating in situ gaseous deposition to construct highly durable Fe–N–C oxygen-reduction fuel cell catalysts

The activity–stability trade-off challenges the design of high-performance atomically dispersed iron–nitrogen–carbon (Fe–N–C) catalysts for the acidic oxygen reduction reaction in polymer electrolyte fuel cells. Here we develop an in situ chemical vapour deposition approach during catalyst synthesis to break the trade-off, producing highly stable Fe–N–C catalysts while maintaining adequate oxygen reduction reaction activity. The optimal catalyst exhibits a half-wave potential of 0.867 V, remaining unchanged after an accelerated stress test (AST) of 100,000 potential cycles in rotating disk electrode tests. In membrane electrode assemblies under H 2 –air conditions, it delivers 93 mA cm −2 at 0.8 V after a standard AST of 30,000 voltage cycles, and shows minimal current density losses (2.9% at 0.6 V; 14.2% at 0.7 V) after an extended AST up to 120,000 cycles. Furthermore, the catalyst’s durability improvement is primarily due to the in situ chemical vapour deposition, which strengthens Fe–N bonds, increases active-site density, mitigates iron aggregates and reduces surface porosity.

Chemical engineering↗

A low temperature unitized regenerative fuel cell realizing 60% round trip efficiency and 10 000 cycles of durability for energy storage applications

Unitized regenerative fuel cells (URFC) convert electrical energy to and from chemical bonds in hydrogen. URFCs have the potential to provide economical means for efficient long-term, seasonal, energy storage and on-demand conversion back to electrical energy. We first optimize the catalyst layer for discrete electrolyzer and fuel cell and then configure the URFC. The goal is to identify a cost competitive configuration for URFCs, and demonstrate it in terms of upper limit of round trip efficiencies (RTEs). Two possible configurations of URFCs are compared via experiments and techno-economic analysis (TEA), which emphasize the advantages of the unconventional constant-electrode (CE) URFC over the traditional constant-gas (CG) configuration. We also study the stability via accelerated stress tests (ASTs) and demonstrate steady state operation in a daily cycle for day to night energy shifting. From the investigations, the optimum composition of the URFC anode catalyst layer is 90 at% Ir-black balanced by Pt-black for both CE and CG configurations. At 80 °C and 1 A cm -2 , the optimized CE URFC achieves 57% and 60% RTE with air and O 2 as the reductant gases, respectively. We then evaluated the differences in durability using an AST over 10k charge–discharge cycles; the results reveal that the wider potential window at the anode in CE (0.05–1.55 V) has minimal effect on catalyst layer stability compared to CG (0.55–1.55 V). Furthermore, there was no degradation up to the range of 2k–5k cycles; beyond that the fuel cell (discharge) performance degraded while the electrolyzer (charge) performance was still stable. Finally, the observations here indicate substantial potential to employ URFCs as efficient and cost-effective bidirectional energy-conversion devices within energy storage and utilization systems after appropriate technological and operational optimizations.

25 ENERGY STORAGE↗

Correlating the Morphological Changes to Electrochemical Performance During Carbon Corrosion in Polymer Electrolyte Fuel Cells

A mechanistic understanding of carbon corrosion in polymer electrolyte fuel cells (PEFCs) is required to design durable catalyst layers. Uncontrolled startup and shutdown of PEFCs cause electrochemical oxidation of carbon, which leads to several degradation phenomena, such as loss in electrochemical surface area (ECSA), pore structure collapse or increase in mass transport resistance. In this study, the chronology of morphological changes in the cathode catalyst layer due to carbon corrosion was identified and correlated with electrochemical performance degradation. PEFCs were subjected to the Department of Energy carbon corrosion accelerated stress test (AST) protocol. The study revealed two phases: in the initial phase (~500 AST cycles), amorphous carbon in contact with Pt nanoparticles oxidized fast. Rapid carbon loss and catalyst layer thinning occurred, but pore structure did not change significantly. Pt nanoparticles detached from the support and ECSA decreased drastically. In the second phase (~1500 AST cycles), carbon corrosion slowed down, but severe pore structure collapse was observed. Porosity and pore connectivity within the cathode catalyst layer decreased considerably. Electrochemical diagnostics corroborated this finding by showing significantly higher O2 mass transport resistance. Lastly, no significant change was observed in the concentration of oxides on the carbon surface after AST. But overall water management in the cathode catalyst layer deteriorated as the pore structure collapsed. This study provides an in-depth understanding of morphological changes during PEFC carbon corrosion AST protocol and motivates novel material design strategies to enable durable PEFCs.

catalyst layers↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗