Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AUTOCLAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

X-33 Tank Failure During Autoclave Fabrication

During a repair cure cycle on tank #1 of the X-33 liquid hydrogen tanks, a skin to core disbond occurred. Both the inner skin and outer skin of the lobe #1 sandwich panel was noted to have been disbonded and cracked- An investigation was undertaken to determine the cause of this failure. The investigation consisted of reviewing all of the processing data and performing testing on the failed lobe #1, as well as the other lobes, which did not fail during the cure cycle. The tests consisted of residual stress measurements in one of the intact lobes and "plug-pulls" to assess skin to core strength on all of the remaining lobes. Results showed an extremely low bondline strength due to lack of proper filleting of the adhesive, in addition, tests showed a very rapid decrease in strength with increasing temperature, as well as a further decrease in strength with a larger number of cycles. Also, the honeycomb used was not vented so pressure could build up within the cells. All of these factors appeared to be contributors to the failure.

Nettles, Alan T.↗

Fiber-Reinforced Epoxy Composites and Methods of Making Same Without the Use of Oven or Autoclave

Method embodiments for producing a fiber-reinforced epoxy composite comprise providing a mold defining a shape for a composite, applying a fiber reinforcement over the mold, covering the mold and fiber reinforcement thereon in a vacuum enclosure, performing a vacuum on the vacuum enclosure to produce a pressure gradient, insulating at least a portion of the vacuum enclosure with thermal insulation, infusing the fiber reinforcement with a reactive mixture of uncured epoxy resin and curing agent under vacuum conditions, wherein the reactive mixture of uncured epoxy resin and curing agent generates exothermic heat, and producing the fiber-reinforced epoxy composite having a glass transition temperature of at least about 100.degree. C. by curing the fiber reinforcement infused with the reactive mixture of uncured epoxy resin and curing agent by utilizing the exothermically generated heat, wherein the curing is conducted inside the thermally insulated vacuum enclosure without utilization of an external heat source or an external radiation source.

Barnell, Thomas J.↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bonded performance. Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This presentation describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the elimination of the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bonded performance. Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This presentation describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the elimination of the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

In-situ Inspection of Reflowable-Interface Composite Joints During Cure in an Autoclave

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded primary-structures to alleviate the inability to certify bonded performance. To address this issue, the NASA Convergent Aeronautics Solutions (CAS): Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process. The reflow and intermixing of the matrix resin during assembly can eliminate the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion at a nearly two-dimensional boundary. AERoBOND process development has evaluated a multitude of parameters including the materials used, the stoichiometric offset of the epoxy resins, time and temperature of cure, and thickness of each ply. Without in-situ process monitoring, the condition of a test article is unknown until mechanical testing is completed. This paper describes the use of an in-situ ultrasonic inspection system to monitor the joining of two composite parts assembled using the AERoBOND technique. This work quantifies the interface by measuring the wave reflection, or lack thereof, at the joint throughout the cure cycle. In addition, the results indicate when reflow and cure of the epoxy resin at the joint occurred. By using the recently developed in-situ inspection method with a mobile ultrasonic transducer, localized results can be obtained across a large portion of the joint with high resolution.

Tyler B Hudson↗

Ultrasonic Inspection During Autoclave Cure of Reflowable-Interface Composite Joints

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making the interface susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded primary-structures due to uncertainty in bond performance. To address this issue, the NASA Convergent Aeronautics Solutions (CAS): Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process that can eliminate the material discontinuity at the interface. Implementing in-situ process monitoring enables assessing the bond quality during processing rather than waiting for post-fabrication mechanical testing to be completed. In this paper, an in-situ ultrasonic inspection system is used to monitor the joining of three composite laminates assembled using the AERoBOND technique. For each panel, the amplitude of the wave reflection at the joint was measured throughout the cure cycle. The results indicate the timing and extent of reflow and cure of the epoxy resin at the joint. Factors indicating end of cure were ascertained and a metric was developed to qualitatively predict acceptable mode-II fracture toughness based on the ultrasonic amplitude at the joint line during cure. In addition, since the inspection system scans an area of the joint, high-resolution localized results can be obtained across the joint.

Tyler B Hudson↗

Detection and Localization of a Fold, Twist, and Overlaps within Tow-Steered Composite Panels During Autoclave Cure

Because of the anisotropic properties of carbon fiber reinforced polymer (CRFP) composites, novel layup architectures, such as tow-steering, can be used to tailor mechanical properties of the composite structure to the loading condition during use. In this work, a tow-steered composite panel was de-signed, laid up using the Integrated Structural Assembly of Advanced Com-posites (ISAAC) automated fiber placement (AFP) machine located at the NASA Langley Research Center (LaRC), and cured while simultaneously be-ing inspected using an ultrasonic inspection system operating inside the auto-clave. The composite panel contained overlaps that are intrinsic to the tow-steered design and had intentionally introduced layup defects including folds, wrinkles, splices, tow twists, foreign object debris (FOD), gaps, and additional overlaps. The inspections during the cure cycle focused on the ar-ea within the laminate containing a fold, a twist, and intrinsic overlaps. The ultrasonic inspections performed during the cure cycle were analyzed and compared to post-cure ultrasonic inspections of the entire laminate.

Composites↗

Detection and Localization of a Fold, Twist, and Overlaps within Tow-Steered Composite Panels During Autoclave Cure

Because of the anisotropic properties of carbon fiber reinforced polymer (CRFP) composites, novel layup architectures, such as tow-steering, can be used to tailor mechanical properties of the composite structure to the loading condition during use. In this work, a tow-steered composite panel was de-signed, laid up using the Integrated Structural Assembly of Advanced Com-posites (ISAAC) automated fiber placement (AFP) machine located at the NASA Langley Research Center (LaRC), and cured while simultaneously be-ing inspected using an ultrasonic inspection system operating inside the auto-clave. The composite panel contained overlaps that are intrinsic to the tow-steered design and had intentionally introduced layup defects including folds, wrinkles, splices, tow twists, foreign object debris (FOD), gaps, and additional overlaps. The inspections during the cure cycle focused on the ar-ea within the laminate containing a fold, a twist, and intrinsic overlaps. The ultrasonic inspections performed during the cure cycle were analyzed and compared to post-cure ultrasonic inspections of the entire laminate.

Composites↗