Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARC CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Gas arc constriction for plasma arc welding

A welding torch for plasma arc welding apparatus has an inert gas applied circumferentially about the arc column externally of the constricting nozzle so as to apply a constricting force on the arc after it has exited the nozzle orifice and downstream of the auxiliary shielding gas. The constricting inert gas is supplied to a plenum chamber about the body of the torch and exits through a series of circumferentially disposed orifices in an annular wall forming a closure at the forward end of the constricting gas plenum chamber. The constricting force of the circumferential gas flow about the arc concentrates and focuses the arc column into a more narrow and dense column of energy after exiting the nozzle orifice so that the arc better retains its energy density prior to contacting the workpiece.

McGee, William F.↗

ARC Stray Light Mitigation

The National Ignition Facility (NIF) is the world’s largest and most energetic laser system, located at Lawrence Livermore National Laboratory (LLNL). It is designed to study inertial confinement fusion and to conduct numerous other experiments. NIF has 192 laser beams that are directed at a small targets located at the center of a 5-m radius spherical vacuum chamber. Currently, four of these 192 beamlines (“one quad”) are undergoing modification to achieve peak power exceeding 10 15 Watts. Though the beams will have about the same energy as other NIF beams, the pulses will be compressed in time to achieve such high peak powers. This new petawatt-class laser, called Advanced Radiographic Capability (ARC), will be the world’s highest-energy, ultra-short-pulse laser and will be used to produce x-rays for backlighting NIF experiments. The 192 laser beams travel about 1.5 km in optical path length down the NIF beamline to the target chamber. It is only in the last few dozen meters, just before entering the target chamber, where the ARC quad is picked-off from the main beamline to enter a compressor vessel to decrease the pulse length and then the parabola vessel to point and focus the light onto the backlighter target.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Next Gen High Efficiency Boosted Engine Development

This work represents an advanced engineering research project partially funded by the U.S. Department of Energy (DOE). Ford Motor Company, FEV North America, and Oak Ridge National Laboratory collaborated to develop a next generation boosted spark ignited engine concept. The project goals, specified by the DOE, were 23% improved fuel economy and 15% reduced weight relative to a 2015 or newer light-duty vehicle. The fuel economy goal was achieved by designing an engine incorporating high geometric compression ratio, high dilution tolerance, low pumping work, and low friction. The increased tendency for knock with high compression ratio was addressed using early intake valve closing (EIVC), cooled exhaust gas recirculation (EGR), an active pre-chamber ignition system, and careful management of the fresh charge temperature. Engine weight reduction measures were implemented throughout the engine system making use of composite materials, advanced manufacturing techniques, and architectural choices. This report outlines the analytical, design, fabrication, and test work conducted for the duration of the project. The combustion system stability, EGR tolerance, and knock resistance were validated on a single cylinder engine. An inline six-cylinder engine was then designed targeting application in the Ford F150. Multi-cylinder engines were produced and tested achieving the target vehicle fuel economy improvement of 23% assessed using measured engine fuel consumption combined with a vehicle drive cycle simulation. Actions were identified and designs were demonstrated to achieve the 15% weight reduction target. This project included items covering a range of technology readiness levels. Some of the technologies explored are production ready, while others were investigated to understand the limitations for what can be achieved in a stoichiometric, gasoline-fueled, spark-ignited internal combustion engine.

42 ENGINEERING↗

Heat dissipation in controlled environment enclosures through the application of water screens

The use of plate glass-water thermal barriers in controlled environment facilities effectively reduces the thermal load within the plant growth chamber. This allows high PPFs to be provided for plant growth and development studies, adequate simulation of daily light integrals, and simulation of peak PPF's. Further, substantial amounts of incandescent lamp supplementation can be used to achieve simulation of daylight R:FR ratios which are needed to ensure adequate stem development in some species. While the focus in this paper is on the use of entire thermal barriers which separate the lighting enclosure from the plant growth chamber, the same principles apply to the use of water jackets for cooling individual lamps (such as can occur with xenon-arc lamps). In this instance, the barrier separating the lamps from the plant chamber can be much simpler (e.g., plexiglass) as the main function of the barrier is to separate the air ventilation of the lamp enclosure from the air system within the plant growth chamber. The main advantage of water as a thermal barrier is the negligible absorption of radiation in the photosynthetically-active and near infrared wavebands. Consequently, plate glass-water barriers typically allow transmission of approximately 90% of radiation in these regions. While ventilated double and triple glazing systems appear to be attractive alternative to water barriers from an operating standpoint, their significant absorption in the biologically-important wavebands (7 - 12%) with each glass layer and longer-wave cut-offs (typically 2500 - 4000 nm) makes them a much less attractive alternative. The data presented here demonstrate clearly that measurement of PPF alone is not an adequate representation of the radiation environment being used in a controlled environment study. The amounts and proportions of long-wave and short-wave radiation in a plant growth chamber are dependent on lamp type, lamp combination, presence of a thermal barrier, the type of thermal barrier between the lamps and the plant growing area and the overall construction and design of the chamber. It is important, therefore, in reporting results of controlled environment studies, to adequately describe both the details of the lighting system used and the characteristics of the radiation produced by that system, so results of different studies can be adequately evaluated and compared.

Warrington, I. J.↗

Emission Spectroscopic Measurements in the Plenum Region of the NASA IHF Arc Jet Facility

A newly designed segment with optical access was installed in the plenum chamber of the 60 MW Interaction Heating arcjet Facility at NASA Ames Research Center. This special segment has ports located off axis, and the optical fibers can be inserted into these ports. The special segment allows for optical examination of the arc-heated flow as it enters the plenum, and thus assists in determining estimates of the thermodynamic state of the inflow to the convergent section of the nozzle. In the present work, optical emission measurements have been made in VIS-NIR region (wavelengths between 500 nm to 900 nm) for two settings of the arc heater - a 6000 A condition (high condition) with the minimum amount of radial injection of cold air in the plenum, and a 3300 A condition (low condition) with significant amount of cold air injection to reduce the enthalpy of the arc-heated stream. The results presented here were obtained using an Acton SP300i spectrometer coupled to a Princeton Instruments PI-max intensified camera. In addition to the optical emission measurements, computations were performed for the flow in the plenum and radiation along lines of sight corresponding to the optical ports. Along the centerline, i.e., the longest line of sight across the plenum cross-section, there is good agreement between computations and measurements for the high enthalpy condition, although the off-axis radial profiles show some differences. For the low enthalpy condition, there are significant differences between computations and measurements. The current working hypothesis is that the computational model does not capture details of the mixing process in the plenum.

Winter, Michael W.↗

SU-E-T-536: LINAC-Based Single Isocenter Frameless SRT for Brain Metastases

Purpose: Single-isocenter Stereotactic Radiotherapy of multiple brain metastases with Varian 21 IX LINAC, using Aktina Pinpoint system for patient setup. Methods: In 2014, five single-isocenter RapidArc SRT plans were delivered to five patients with 2 to 8 brain metastases using Varian 21 IX. Aktina Pinpoint system was used for setup and 2mm PTV margin were used. CBCT was acquired before and after the beam delivery. The prescription is 2100 cGy in 3 fractions. Eclipse planning system was used for treatment planning. Depending on the number of metastases and their locations, 1 to 5 coplanar or non coplanar arcs were used. Typically, 2 or 3 arcs are used. IMRT QAs were performed by comparing an A1SL ion chamber point dose measurement in solid water phantom to point dose of the plan; also, based on EPID measurement, 3D spatial dose was calculated using DosimetryCheck software package from MathResolutions Inc. The EPID system has an active area of 40cm by 30cm with 1024 by 768 photodiodes, which corresponds to a resolution of 0.4mm by 0.4mm pixel dimension. Results: for all the plans, at least 95% PTV coverage was achieved for full prescription dose, with plan normalization > 75%. RTOG conformity indices are less than 1.1 and Paddick gradient indices are less than 4.5. The distance from prescription IDL to 50% IDL increases as the number of metastases increases, and it ranges from 0.6mm to 0.8mm. Treatment time varies from 10mins to 30mins, depending on the number of arcs and if the arcs are coplanar. IMRT QA shows that the ion chamber measurement agree with the eclipse calculation within 3%, and 95% of the points passed Gamma, using 3% dose difference and 3mm DTA Conclusion: High quality single isocenter RapidArc SRT plan can be optimized and accurately delivered using Eclipse and Varian 21IX.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA GRC and MSFC Space-Plasma Arc Testing Procedures

Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. Discussed herein are neutral gas conditions, plasma densities and uniformity, vacuum chamber sizes, sample sizes and Debye lengths, biasing samples versus self-generated voltages, floating samples versus grounded samples, test electrical conditions, arc detection, preventing sustained discharges during testing, real samples versus idealized samples, validity of LEO tests for GEO samples, extracting arc threshold information from arc rate versus voltage tests, snapover, current collection, and glows at positive sample bias, Kapton pyrolysis, thresholds for trigger arcs, sustained arcs, dielectric breakdown and Paschen discharge, tether arcing and testing in very dense plasmas (i.e. thruster plumes), arc mitigation strategies, charging mitigation strategies, models, and analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

Ferguson, Dale C.↗

A low cost versatile arc melter

Arc melter using Pyrex pipe cross for controlled atmosphere chamber, incorporating Ar jet into electrode holder for dynamic flushing and rapid quenching

Cadieu, F. J.↗

Laboratory simulation of field-aligned currents

A summary of progress during the period Apr. 1992 to Mar. 1993 is provided. Objectives of the research are (1) to simulate, via laboratory experiments, the three terms of the field-aligned current equation; (2) to simulate auroral-arc formation processes by configuring the boundary conditions of the experimental chamber and plasma parameters to produce highly localized return currents at the end of a field-aligned current system; and (3) to extrapolate these results, using theoretical and computational techniques, to the problem of magnetospheric-ionospheric coupling and to compare them with published literature signatures of auroral-arc phenomena.

Wessel, Frank J.↗

Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experimental study of waveguide coupled microwave heating with conventional multicusp negative ion sources

Negative ion production with conventional multicusp plasma chambers utilizing 2.45 GHz microwave heating is demonstrated. The experimental results were obtained with the multicusp plasma chambers and extraction systems of the RF-driven RADIS ion source and the filament driven arc discharge ion source LIISA. A waveguide microwave coupling system, which is almost similar to the one used with the SILHI ion source, was used. The results demonstrate that at least one third of negative ion beam obtained with inductive RF-coupling (RADIS) or arc discharge (LIISA) can be achieved with 1 kW of 2.45 GHz microwave power in CW mode without any modification of the plasma chamber. The co-extracted electron to H{sup −} ratio and the optimum pressure range were observed to be similar for both heating methods. The behaviour of the plasma implies that the energy transfer from the microwaves to the plasma electrons is mainly an off-resonance process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of throttling on forward radiated fan noise

A study was undertaken to evaluate the effect of operating line throttling on inlet-arc noise from high speed fans. Experimental measurements on a 1/4-scale fan stage tested in an anechoic chamber, with and without inlet turbulence control devices, were utilized to assess the effect of constant speed throttling on the forward arc radiated noise characteristics. Different effects were observed in different speed ranges with different types of inflow turbulence control. These effects were correlated with some of the current theories on fan noise generation mechanisms, and partial success was achieved in attempting to relate the various theoretical models to the observed trends. The results of this study have an important bearing on estimating the noise characteristics of new fan designs from scaling the measured characteristics of previously tested fans.

Gliebe, P. R.↗

Megavoltage Cone Beam Computed Tomography Dose and the Necessity of Reoptimization for Imaging Dose-Integrated Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: Megavoltage cone beam computed tomography (MV-CBCT) dose can be integrated with the patient's prescription. Here, we investigated the effects of imaging dose and the necessity for additional optimization when using intensity-modulated radiotherapy (IMRT) to treat prostate cancer. Methods and Materials: An arc beam mimicking MV-CBCT was generated using XiO (version 4.50; Elekta, Stockholm, Sweden). The monitor units (MU) for dose calculation were determined by conforming the calculated dose to the dose measured using an ionization chamber. IMRT treatment plans of 22 patients with prostate cancer were retrospectively analyzed. Arc beams of 3, 5, 8, and 15 MU were added to the IMRT plans, and the dose covering 95% of the planning target volume (PTV) was normalized to the prescribed dose with (reoptimization) or without optimization (compensation). Results: PTV homogeneity and conformality changed negligibly with MV-CBCT integration. For critical organs, an imaging dose-dependent increase was observed for the mean rectal/bladder dose (D{sub mean}), and reoptimization effectively suppressed the D{sub mean} elevations. The bladder generalized equivalent uniform dose (gEUD) increased with imaging dose, and reoptimization suppressed the gEUD elevation when 5- to 15-MU CBCT were added, although rectal gEUD changed negligibly with any imaging dose. Whereas the dose elevation from the simple addition of the imaging dose uniformly increased rectal and bladder dose, the rectal D{sub mean} increase of compensation plans was due mainly to low-dose volumes. In contrast, bladder high-dose volumes were increased by integrating the CBCT dose, and reoptimization reduced them when 5- to 15-MU CBCT were added. Conclusion: Reoptimization is clearly beneficial for reducing dose to critical organs, elevated by addition of high-MU CBCT, especially for the bladder. For low-MU CBCT aimed at bony structure visualization, compensation is sufficient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA GRC and MSFC Space-Plasma Arc Testing Procedures

Tests of arcing and current collection in simulated space plasma conditions have been performed at the NASA Glenn Research Center (GRC) in Cleveland, Ohio, for over 30 years and at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, for almost as long. During this period, proper test conditions for accurate and meaningful space simulation have been worked out, comparisons with actual space performance in spaceflight tests and with real operational satellites have been made, and NASA has achieved our own internal standards for test protocols. It is the purpose of this paper to communicate the test conditions, test procedures, and types of analysis used at NASA GRC and MSFC to the space environmental testing community at large, to help with international space-plasma arcing-testing standardization. To be discussed are: 1.Neutral pressures, neutral gases, and vacuum chamber sizes. 2. Electron and ion densities, plasma uniformity, sample sizes, and Debuy lengths. 3. Biasing samples versus self-generated voltages. Floating samples versus grounded. 4. Power supplies and current limits. Isolation of samples from power supplies during arcs. 5. Arc circuits. Capacitance during biased arc-threshold tests. Capacitance during sustained arcing and damage tests. Arc detection. Prevention sustained discharges during testing. 6. Real array or structure samples versus idealized samples. 7. Validity of LEO tests for GEO samples. 8. Extracting arc threshold information from arc rate versus voltage tests. 9. Snapover and current collection at positive sample bias. Glows at positive bias. Kapon (R) pyrolisis. 10. Trigger arc thresholds. Sustained arc thresholds. Paschen discharge during sustained arcing. 11. Testing for Paschen discharge threshold. Testing for dielectric breakdown thresholds. Testing for tether arcing. 12. Testing in very dense plasmas (ie thruster plumes). 13. Arc mitigation strategies. Charging mitigation strategies. Models. 14. Analysis of test results. Finally, the necessity of testing will be emphasized, not to the exclusion of modeling, but as part of a complete strategy for determining when and if arcs will occur, and preventing them from occurring in space.

Ferguson, Dale C.↗

Arcing of negatively biased solar cells in low earth orbit

A set of experiments is described in which the arcing of negatively biased solar cells is examined and characterized in terms of the primary factors that cause such behavior. The experiments are conducted in an ultrahigh vacuum chamber, and an image-intensified CCD camera is employed to monitor UV emission from arc events at the interfacial edge between the cover slip and the solar cell. A bead of encapsulant along the interfacial edge is noted which can be removed to reduce arc frequency, and water contamination is found to further enhance arcing. Frequency of arcing is found to vary indirectly with temperature and directly with exposure to H2O, but no other significant correlations are noted. The sensitivity to H2O vapor is eliminated by simply removing the adhesive/encapsulant, and the corresponding arc-rate performance is low.

Upschulte, B. L.↗

ArCS: A Magnetized LArTPC in a Test Beam

Over the past few decades, Liquid Argon Time Projection Chambers (LArTPCs) have emerged as a central technology for rare-event detection, due to their calorimetric and imaging capabilities. Adding a magnetic field to LArTPCs would enable charge identification and momentum measurements via curvature. For neutrino experiments, this is crucial for wrong-sign neutrino rejection, electron/positron and electron/photon discrimination, and improved momentum reconstruction. The ArCS (Argon detector with Charge Separation) experiment at Fermilab's Test Beam Facility will place a 47 40 90 cm LArTPC inside a 0.7 T magnet to: (i) establish charge sign discrimination for electrons and positrons, (ii) reconstruct particle momenta via curvature, and (iii) determine the minimal magnetic field needed for these measurements. This poster will present the project status, with updates on installation and simulations of expected performance.

Cicogna, Giulia [Bologna U.]↗

EGRET - The high energy gamma ray telescope for NASA's Gamma Ray Observatory

The EGRET high energy gamma-ray telescope under development for NASA's Gamma Ray Observatory will have an energy range of approximately 12 to 30,000 MeV, energy resolution of about 15 percent FWHM over most of that range, an effective area of about 2000 sq cm at high energies, and single photon angular accuracy of approximately 2 deg at 100 MeV, less than 0.1 deg above 5 GeV. This instrument can locate strong sources to an accuracy of about 5 arc min. The instrument utilizes a set of digital spark chambers interleaved with tantalum foils for detection and identification of gamma-ray events, and a large NaI(Tl) scintillator for energy determination. The system is triggered by a coincidence matrix using two arrays of plastic scintillation counters and a large plastic scintillator anticoincidence dome that rejects incident charged particles.

Fichtel, C. E.↗

Induction Heating of Hypervelocity Impact Samples to 2500 Degrees Centigrade

The Remote Hypervelocity Test Laboratory (RHTL) at White Sands Test Facility (WSTF) was asked to heat samples up to 2500 degrees Centigrade (4532 degrees Fahrenheit) to simulate reentry scenarios of crafts where heated shields are impacted with single small particles ranging from 0.2 to 1.0 millimeters (.008 to.039 inches) of various materials. The team decided an electromagnetic induction (induction heater) was the best method to achieve and control the temperatures in a rapid manner. The samples consisted of three-dimensional carbon-carbon and two-dimensional carbon-phenolic, which are both electrically conductive. After several attempts the team was able to achieve over 2500 degrees Centigrade (4532 degrees Fahrenheit) in ambient atmosphere. When the system was moved to the target chamber and the vacuum system evacuated down to 250 millitorr, arcing occurred between the bus bars and tank, the feedthrough fittings that carried the coolant and current, and between the target sample and coil. To overcome this arcing, conformal coatings, room temperature vulcanization (RTV) silicone, and other non-conductive materials were used to isolate the electromagnetic fields.

Simmons, Joshua↗