Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Food web dynamics drive variation in Smallmouth Bass Micropterus dolomieu mercury contamination in protected Southern Appalachian streams

Mercury is a global pollutant that threatens otherwise protected aquatic ecosystems. Mercury food web dynamics are not well understood in streams with no point sources of contamination but have the potential to concentrate this dangerous pollutant in upper trophic level consumers. A 2016 study revealed that mercury concentrations of Smallmouth Bass Micropterus dolomieu varied between three streams in Great Smoky Mountains National Park (GSMNP), Tennessee, USA. We tested the hypothesis that food web interactions drive spatial variation in mercury concentrations of the apex predator of protected stream ecosystems. We measured carbon and nitrogen stable isotope ratios, and mercury concentrations of eight food web components of GSMNP streams including basal resources, intermediate consumers, and Smallmouth Bass, the apex predator. Mean THg concentrations of basal resources did not differ between streams, but the spatial pattern of concentrations of intermediate consumers mirrored Smallmouth Bass. Relationships between organismal contaminant concentrations and trophic level were positive in all three streams, indicating biomagnification is occurring in the protected streams of GSMNP. Furthermore, our findings indicate that mercury dynamics in intermediate trophic levels, rather than differences in basal resource concentrations, may drive differences in mercury contamination of apex predators of the protected stream ecosystems of GSMNP.

Bioaccumulation↗

Dose-Volume Differences for Computed Tomography and Magnetic Resonance Imaging Segmentation and Planning for Proton Prostate Cancer Therapy

Purpose: To determine the influence of magnetic-resonance-imaging (MRI)-vs. computed-tomography (CT)-based prostate and normal structure delineation on the dose to the target and organs at risk during proton therapy. Methods and Materials: Fourteen patients were simulated in the supine position using both CT and T2 MRI. The prostate, rectum, and bladder were delineated on both imaging modalities. The planning target volume (PTV) was generated from the delineated prostates with a 5-mm axial and 8-mm superior and inferior margin. Two plans were generated and analyzed for each patient: an MRI plan based on the MRI-delineated PTV, and a CT plan based on the CT-delineated PTV. Doses of 78 Gy equivalents (GE) were prescribed to the PTV. Results: Doses to normal structures were lower when MRI was used to delineate the rectum and bladder compared with CT: bladder V50 was 15.3% lower (p = 0.04), and rectum V50 was 23.9% lower (p = 0.003). Poor agreement on the definition of the prostate apex was seen between CT and MRI (p = 0.007). The CT-defined prostate apex was within 2 mm of the apex on MRI only 35.7% of the time. Coverage of the MRI-delineated PTV was significantly decreased with the CT-based plan: the minimum dose to the PTV was reduced by 43% (p < 0.001), and the PTV V99% was reduced by 11% (p < 0.001). Conclusions: Using MRI to delineate the prostate results in more accurate target definition and a smaller target volume compared with CT, allowing for improved target coverage and decreased doses to critical normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adiabatic Tip-Plasmon Focusing for Nano-Raman Spectroscopy

True nanoscale optical spectroscopy requires the efficient delivery of light for a spatially nanoconfined excitation. We utilize adiabatic plasmon focusing to concentrate an optical field into the apex of a scanning probe tip of {approx}10 nm in radius. The conical tips with the ability for two-stage optical mode matching of the surface plasmon polariton (SPP) grating-coupling and the adiabatic propagating SPP conversion into a localized SPP at the tip apex represent a special optical antenna concept for far-field transduction into nanoscale excitation. The resulting high nanofocusing efficiency and the spatial separation of the plasmonic grating coupling element on the tip shaft from the near-field apex probe region allows for true background-free nanospectroscopy. As an application, we demonstrate tip-enhanced Raman spectroscopy (TERS) of surface molecules with enhanced contrast and its extension into the near-IR with 800 nm excitation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Location of γ -ray emission and magnetic field strengths in OJ 287

We report the γ-ray BL Lac object OJ 287 is known to exhibit inner-parsec “jet-wobbling”, high degrees of variability at all wavelengths and quasi-stationary features, including an apparent (≈100°) position-angle change in projection on the sky plane. Sub-50 micro-arcsecond resolution 86 GHz observations with the global mm-VLBI array (GMVA) supplement ongoing multi-frequency VLBI blazar monitoring at lower frequencies. Using these maps, together with cm/mm total intensity and γ-ray observations from Fermi-LAT from 2008-2014, we aim to Observations with the GMVA offer approximately double the angular resolution compared with 43 GHz VLBA observations and enable us to observe above the synchrotron self-absorption peak frequency. Fermi-LAT γ-ray data were reduced and analysed. The jet was spectrally decomposed at multiple locations along the jet. From this, we could derive estimates of the magnetic field using equipartition and synchrotron self-absorption arguments. How the field decreases down the jet provided an estimate of the distance to the jet apex and an estimate of the magnetic field strength at the jet apex and in the broad line region. Combined with accurate kinematics, we attempt to locate the site of γ-ray activity, radio flares, and spectral changes. Strong γ-ray flares appeared to originate from either the so-called core region, a downstream stationary feature, or both, with γ-ray activity significantly correlated with radio flaring in the downstream quasi-stationary feature. Magnetic field estimates were determined at multiple locations along the jet, with the magnetic field found to be ≥1.6 G in the core and ≤0.4 G in the downstream quasi-stationary feature. Finally, we therefore found upper limits on the location of the VLBI core as ≲6.0 pc from the jet apex and determined an upper limit on the magnetic field near the jet base of the order of thousands of Gauss.

79 ASTRONOMY AND ASTROPHYSICS↗

A method to determine the onset voltage of single and arrays of electrospray emitters

This paper reports on an accurate and rapid method to compute the onset voltage of a single or an array of electrospray emitters with complex geometries and on the correlation of the simulation with experimental data. This method permits the exact determination of the onset voltage based only on the surface tension of the sprayed liquid and on the emitter geometry. The approach starts by determining the voltage at which electrostatic forces and surface tension forces are equal for a sharpening conic surface at the tip of a capillary as a function of the apex radius of the liquid. By tracing the curve of this computed equilibrium voltage as a function of the apex radius, the onset voltage for a liquid surface with the Taylor half-angle of 49.3 deg. or larger can be determined. For smaller cone half-angles the method is only applicable to ionic sprays as an approximate knowledge of the critical field for ion emission is necessary. The combination of analytical models and finite element tools used to compute the necessary parameters is described. The method is validated on a complex microelectromechanical system emitter geometry as well as on a linear array of electrospray emitters. Finally an empirical model of the behavior of the electric field near the apex of a conic surface with asymptotes at a fixed half-angle is proposed, which allows establishing a simple method for onset voltage determination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of sharp tungsten-coated tip for atomic force microscopy by ion-beam sputter deposition

Tungsten (W) is significantly suitable as a tip material for atomic force microscopy (AFM) because its high mechanical stiffness enables the stable detection of tip-sample interaction forces. We have developed W sputter-coating equipment to compensate the drawbacks of conventional Si cantilever tips used in AFM measurements. By employing an ion gun commonly used for sputter cleaning of a cantilever tip, the equipment is capable of depositing conductive W films in the preparation chamber of a general ultrahigh vacuum (UHV)-AFM system without the need for an additional chamber or transfer system. This enables W coating of a cantilever tip immediately after sputter cleaning of the tip apex and just before the use in AFM observations. The W film consists of grain structures, which prevent tip dulling and provide sharpness (<3 nm in radius of curvature at the apex) comparable to that of the original Si tip apex. We demonstrate that in non-contact (NC)-AFM measurement, a W-coated Si tip can clearly resolve the atomic structures of a Ge(001) surface without any artifacts, indicating that, as a force sensor, the fabricated W-coated Si tip is superior to a bare Si tip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation characteristics of femtosecond laser-induced plasma channel Vee antenna

A virtual reconfigurable plasma Vee antenna consisting of a set of laser plasma filaments produced by femtosecond laser pulses in air is investigated in this paper. The calculation results show that radiation pattern becomes more complex and gain shows initially rapid rise but gradually saturate as the leg length increases, but the pattern and gain are not seriously affected by the plasma conductivity; particularly, the gain of the Vee antenna with plasma conductivity σ = 100S/m can reach about 80% of that of a copper antenna. Radiation efficiency of the antenna has shown a strong dependence on radius of the antenna leg, and an efficiency of 65%, considered to have a proper performance, can be obtained with the channel radius of about 10 mm. Apex angle variation can lead to significant change of the radiation pattern and influence the gain; the best apex angle corresponding to maximal gain and good directivity for the third resonance antenna leg length is found to be at 74° at 600 MHz and σ = 100 S/m. The calculation has shown that at terawatt laser power level, the plasma channel conductivity is close to that of conventional plasma antenna, and peak gain of the Vee antenna is more than 8 dB with a good directivity. In addition, the radiation pattern of special Vee antennas with apex angle 180°-dipole antennas, for first and third resonance leg lengths, is compared and underneath physics of the difference is given. The laser-induced plasma channel antenna is especially suitable for achieving good directivity and gain, which has advantage over conventional plasma antenna with gas discharge tube or metal antenna.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

INITIATION OF CORONAL MASS EJECTION AND ASSOCIATED FLARE CAUSED BY HELICAL KINK INSTABILITY OBSERVED BY SDO/AIA

In this paper, we present multiwavelength observations of helical kink instability as a trigger of a coronal mass ejection (CME) which occurred in active region NOAA 11163 on 2011 February 24. The CME was associated with an M3.5 limb flare. High-resolution observations from the Solar Dynamics Observatory/Atmospheric Imaging Assembly suggest the development of helical kink instability in the erupting prominence, which implies a flux rope structure of the magnetic field. A brightening starts below the apex of the prominence with its slow rising motion ({approx}100 km s{sup -1}) during the activation phase. A bright structure, indicative of a helix with {approx}3-4 turns, was transiently formed at this position. The corresponding twist of {approx}6{pi}-8{pi} is sufficient to generate the helical kink instability in a flux rope according to recently developed models. A slowly rising blob structure was subsequently formed at the apex of the prominence, and a flaring loop was observed near the footpoints. Within 2 minutes, a second blob was formed in the northern prominence leg. The second blob erupts (like a plasmoid ejection) with the detachment of the northern prominence leg, and flare intensity maximizes. The first blob at the prominence apex shows rotational motion in the counterclockwise direction in the plane of sky, interpreted as the unwinding motion of a helix, and it also erupts to give the CME. RHESSI hard X-ray (HXR) sources show the two footpoint sources and a loop-top source during the flare. We found RHESSI HXR flux, soft X-ray flux derivative, and CME acceleration in the low corona correlate well, which is in agreement with the standard flare model (CSHKP). We also discuss the possible role of ballooning as well as torus instabilities in driving the CME. We conclude that the CME and flare were triggered by the helical kink instability in a flux rope and accelerated mainly by the torus instability.

79 ASTRONOMY AND ASTROPHYSICS↗

Characteristics of miniature electronic brachytherapy x-ray sources based on TG-43U1 formalism using Monte Carlo simulation techniques

Purpose: The goal of this study is to determine a method for Monte Carlo (MC) characterization of the miniature electronic brachytherapy x-ray sources (MEBXS) and to set dosimetric parameters according to TG-43U1 formalism. TG-43U1 parameters were used to get optimal designs of MEBXS. Parameters that affect the dose distribution such as anode shapes, target thickness, target angles, and electron beam source characteristics were evaluated. Optimized MEBXS designs were obtained and used to determine radial dose functions and 2D anisotropy functions in the electron energy range of 25-80 keV. Methods: Tungsten anode material was considered in two different geometries, hemispherical and conical-hemisphere. These configurations were analyzed by the 4C MC code with several different optimization techniques. The first optimization compared target thickness layers versus electron energy. These optimized thicknesses were compared with published results by Ihsan et al.[Nucl. Instrum. Methods Phys. Res. B 264, 371-377 (2007)]. The second optimization evaluated electron source characteristics by changing the cathode shapes and electron energies. Electron sources studied included; (1) point sources, (2) uniform cylinders, and (3) nonuniform cylindrical shell geometries. The third optimization was used to assess the apex angle of the conical-hemisphere target. The goal of these optimizations was to produce 2D-dose anisotropy functions closer to unity. An overall optimized MEBXS was developed from this analysis. The results obtained from this model were compared to known characteristics of HDR {sup 125}I, LDR {sup 103}Pd, and Xoft Axxent electronic brachytherapy source (XAEBS) [Med. Phys. 33, 4020-4032 (2006)]. Results: The optimized anode thicknesses as a function of electron energy is fitted by the linear equation Y ({mu}m) = 0.0459X (keV)-0.7342. The optimized electron source geometry is obtained for a disk-shaped parallel beam (uniform cylinder) with 0.9 mm radius. The TG-43 distribution is less sensitive to the shape of the conical-hemisphere anode than the hemispherical anode. However, the optimized apex angle of conical-hemisphere anode was determined to be 60 deg. For the hemispherical targets, calculated radial dose function values at a distance of 5 cm were 0.137, 0.191, 0.247, and 0.331 for 40, 50, 60, and 80 keV electrons, respectively. These values for the conical-hemisphere targets are 0.165, 0.239, 0.305, and 0.412, respectively. Calculated 2D anisotropy functions values for the hemispherical target shape were F(1 cm, 0 deg.) = 1.438 and F(1 cm, 0 deg.) = 1.465 for 30 and 80 keV electrons, respectively. The corresponding values for conical-hemisphere targets are 1.091 and 1.241, respectively. Conclusions: A method for the characterizations of MEBXS using TG-43U1 dosimetric data using the MC MCNP4C has been presented. The effects of target geometry, thicknesses, and electron source geometry have been investigated. The final choices of MEBXS design are conical-hemisphere target shapes having an apex angle of 60 deg. Tungsten material having an optimized thickness versus electron energy and a 0.9 mm radius of uniform cylinder as a cathode produces optimal electron source characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional quadratic modeling and quantitative evaluation of the diaphragm on a volumetric CT scan in patients with chronic obstructive pulmonary disease

Purpose: In patients with chronic obstructive pulmonary disease (COPD), diaphragm function may deteriorate due to reduced muscle fiber length. Quantitative analysis of the morphology of the diaphragm is therefore important. In the authors current study, they propose a diaphragm segmentation method for COPD patients that uses volumetric chest computed tomography (CT) data, and they provide a quantitative analysis of the diaphragmatic dimensions. Methods: Volumetric CT data were obtained from 30 COPD patients and 10 normal control patients using a 16-row multidetector CT scanner (Siemens Sensation 16) with 0.75-mm collimation. Diaphragm segmentation using 3D ray projections on the lower surface of the lungs was performed to identify the draft diaphragmatic lung surface, which was modeled using quadratic 3D surface fitting and robust regression in order to minimize the effects of segmentation error and parameterize diaphragm morphology. This result was visually evaluated by an expert thoracic radiologist. To take into consideration the shape features of the diaphragm, several quantification parameters—including the shape index on the apex (SIA) (which was computed using gradient set to 0), principal curvatures on the apex on the fitted diaphragm surface (CA), the height between the apex and the base plane (H), the diaphragm lengths along the x-, y-, and z-axes (XL, YL, ZL), quadratic-fitted diaphragm lengths on the z-axis (FZL), average curvature (C), and surface area (SA)—were measured using in-house software and compared with the pulmonary function test (PFT) results. Results: The overall accuracy of the combined segmentation method was 97.22% ± 4.44% while the visual accuracy of the models for the segmented diaphragms was 95.28% ± 2.52% (mean ± SD). The quantitative parameters, including SIA, CA, H, XL, YL, ZL, FZL, C, and SA were 0.85 ± 0.05 (mm{sup −1}), 0.01 ± 0.00 (mm{sup −1}), 17.93 ± 10.78 (mm), 129.80 ± 11.66 (mm), 163.19 ± 13.45 (mm), 71.27 ± 17.52 (mm), 61.59 ± 16.98 (mm), 0.01 ± 0.00 (mm{sup −1}), and 34 380.75 ± 6680.06 (mm{sup 2}), respectively. Several parameters were correlated with the PFT parameters. Conclusions: The authors propose an automatic method for quantitatively evaluating the morphological parameters of the diaphragm on volumetric chest CT in COPD patients. By measuring not only the conventional length and surface area but also the shape features of the diaphragm using quadratic 3D surface modeling, the proposed method is especially useful for quantifying diaphragm characteristics. Their method may be useful for assessing morphological diaphragmatic changes in COPD patients.

60 APPLIED LIFE SCIENCES↗

Transition radiation emitted by a particle moving along the axis of a perfectly conducting conical surface

The spatial field distribution is determined for the transition radiation emitted by a relativistic particle moving along the axis of a perfectly conducting circular conical surface with a fixed apex. Emission from particles moving away from and towards the apex is examined. Expressions are obtained that can be used to calculate the angular distribution of radiation intensity for various apex angles between 0 and {pi}. Significant differences are demonstrated between the spatial distributions of radiation generated by outgoing and incoming particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CONSTRAINTS ON THE PRESENCE OF SiO GAS IN THE DEBRIS DISK OF HD 172555

We have carried out two sets of observations to quantify the properties of SiO gas in the unusual HD 172555 debris disk: (1) a search for the J = 8–7 rotational transition from the vibrational ground state, carried out with the Atacama Pathfinder EXperiment (APEX) submillimeter telescope and heterodyne receiver at 863 μ m and (2) a search at 8.3 μ m for the P(17) ro-vibrational transition of gas phase SiO, carried out with the Very Large Telescope (VLT)/VISIR with a resolution, λ /Δ λ , of 30,000. The APEX measurement resulted in a 3.3 σ detection of an interstellar feature, but only an upper limit to emission at the radial velocity and line width expected from HD 172555. The VLT/VISIR result was also an upper limit. These were used to provide limits for the abundance of gas phase SiO for a range of temperatures. The upper limit from our APEX detection, assuming an 8000 K primary star photospheric excitation, falls more than an order of magnitude below the self-shielding stability threshold derived by Johnson et al. (2012). Our results thus favor a solid-state origin for the 8.3 μ m feature seen in the Spitzer IRS spectrum of the circumstellar excess emission and the production of circumstellar O i and Si i by SiO UV photolysis. The implications of these estimates are explored in the framework of models of the HD 172555 circumstellar disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Pyramidal space frame and associated methods

A space frame having a high torsional strength comprising a first square bipyramid and two planar structures extending outward from an apex of the first square bipyramid to form a "V" shape is disclosed. Some embodiments comprise a plurality of edge-sharing square bipyramids configured linearly, where the two planar structures contact apexes of all the square bipyramids. A plurality of bridging struts, apex struts, corner struts and optional internal bracing struts increase the strength and rigidity of the space frame. In an embodiment, the space frame supports a solar reflector, such as a parabolic solar reflector. Methods of fabricating and using the space frames are also disclosed.

14 SOLAR ENERGY↗

M3 Wave DMP/APEX WEC Laboratory Testing Content Model

Laboratory Testing Content Model of Hinsdale 1:5 testing of thirteen different APEX I and APEX II configurations in the Long Wave Flume with a 0.5m deep sediment bed and under 4 different wave conditions.

16 TIDAL AND WAVE POWER↗

XPRESS: eXascale PRogramming Environment and System Software, Final Report

The University of Oregon (UO) was a partner in the XPRESS project together with Sandia National Laboratories (SNL), Indiana University (IU), Lawrence Berkeley National Laboratory (LBL), Louisiana State University (LSU), Oak Ridge National Laboratory (ORNL), University of Houston (UH), and University of North Carolina (RENCI). UO's objective in the project was to develop "APEX (Asynchronous Performance Environment for eXascale)": performance measurement, analysis, feedback and control infrastructure to asynchronous tasking runtimes, specifically HPX (LSU) and HPX-5 (IU). During the project period, our efforts focused on the need to measure complex tasking models where the traditional instrumentation methods would not work due to an absent/meaningless call-path context and runtime control of task pre-emption and resumption, usually on a different operating system thread. In addition to the challenges of performance measurement, we developed a framework to provide information from all levels of the stack (hardware, operating system, runtime, application) to a feedback & control mechanism for controlling concurrency, task granularity, networking parameters, and other aspects of execution in order to improve execution performance, throughput and/or efficiency. UO demonstrated these developments on leading edge HPC machines at large scale, including a 2017 Gordon Bell submission in which APEX was used to optimize key bottlenecks in an astrophysics application. The following final report summarizes our accomplishments during the XPRESS project.

99 GENERAL AND MISCELLANEOUS↗

Preserved and variable spatial‐chemical changes of lipids across tomato leaves in response to central vein wounding reveals potential origin of linolenic acid in signal transduction cascade

Abstract Membrane lipids serve as substrates for the generation of numerous signaling lipids when plants are exposed to environmental stresses, and jasmonic acid, an oxidized product of 18‐carbon unsaturated fatty acids (e.g., linolenic acid), has been recognized as the essential signal in wound‐induced gene expression. Yet, the contribution of individual membrane lipids in linolenic acid generation is ill‐defined. In this work, we performed spatial lipidomic experiments to track lipid changes that occur locally at the sight of leaf injury to better understand the potential origin of linolenic and linoleic acids from individual membrane lipids. The central veins of tomato leaflets were crushed using surgical forceps, leaves were cryosectioned and analyzed by two orthogonal matrix‐assisted laser desorption/ionization mass spectrometry imaging platforms for insight into lipid spatial distribution. Significant changes in lipid composition are only observed 30 min after wounding, while after 60 min lipidome homeostasis has been re‐established. Phosphatidylcholines exhibit a variable pattern of spatial behavior in individual plants. Among lysolipids, lysophosphatidylcholines strongly co‐localize with the injured zone of wounded leaflets, while, for example, lysophosphatidylglycerol (LPG) (16:1) accumulated preferentially toward the apex in the injured zone of wounded leaflets. In contrast, two other LPGs (LPG [18:3] and LPG [18:2]) are depleted in the injured zone. Our high‐resolution co‐localization imaging analyses suggest that linolenic acids are predominantly released from PCs with 16_18 fatty acid composition along the entire leaf, while it seems that in the apex zone PG (16:1_18:3) significantly contributes to the linolenic acid pool. These results also indicate distinct localization and/or substrate preferences of phospholipase isoforms in leaf tissue.

59 BASIC BIOLOGICAL SCIENCES↗

An electron fixed target experiment to search for a new vector boson A' decaying to e + e -

We describe an experiment to search for a new vector boson A' with weak coupling alpha' > 6 x 10 –8 α to electrons (α' = e 2 /4π) in the mass range 65 MeV < m A' < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the "dark photon" A' with the photon -- one of the very few ways in which new forces can couple to the Standard Model -- and have received considerable attention as an explanation of various dark matter related anomalies. A' bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e + e - spectrum. We summarize the experimental approach described in a proposal submitted to Jefferson Laboratory's PAC35, PR-10-009. This experiment, the A' Experiment (APEX), uses the electron beam of the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory (CEBAF) at energies of ~1-4 GeV incident on 0.5-10% radiation length Tungsten wire mesh targets, and measures the resulting e+e- pairs to search for the A' using the High Resolution Spectrometer and the septum magnet in Hall A. With a ~1 month run, APEX will achieve very good sensitivity because the statistics of e+e- pairs will be ~10,000 times larger in the explored mass range than any previous search for the A' boson. These statistics and the excellent mass resolution of the spectrometers allow sensitivity to α'/α one to three orders of magnitude below current limits, in a region of parameter space of great theoretical and phenomenological interest. Similar experiments could also be performed at other facilities, such as the Mainz Microtron.

43 PARTICLE ACCELERATORS↗