Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ADIABATIC DEMAGNETIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Bolometer and photosensitive detector systems for IR

In order to achieve the full sensitivity required for future space astronomy applications, IR detector systems will have to be cooled to 0.1 K or less. The feasibility of such cryocooling has been demonstrated for the established laboratory technique of adiabatic demagnetization, and it has been shown that bolometers made from compensated silicon, with ion-implanted contacts, come close to calculated ultimate performance limits. Unlike bolometers, silicon and germanium photoconductors are highly wavelength-dependent. Useful wavelengths are presented for the most promising photodetectors based on these materials. It is noted that, as the relevant microelectronic technology advances, array detectors in the near-IR may be expected to approach the size and performance of large, intrinsic silicon CCD arrays now available for optical wavelengths.

Low, F. J.↗

Motorized Cyrogenic Valve

Remotely-controlled cryogenic valve operates over temperature range from room temperature to 2 K. Valve used in helium dilution refrigerators, cryostats and adiabatic-demagnetization refrigerators.

Salerno, L.↗

Sub-Kelvin temperatures in space

It is pointed out that the use of temperatures below 1 K in space would provide a significant improvement in several areas of research. The sensitivity of bolometers, for instance, can be improvead by as much as a factor of 50, if the operating temperature is lowered from 1.5 K to 0.3 K. A decrease in temperature to 0.1 K can provide even an improvement up to three orders of magnitude. Detectors based on the utilization of such improvements could be employed for far-infrared (100-1000 microns) photometry and spectroscopy in the low-background conditions of space. The study of critical phenomena in He-3/He-4 mixtures is also of interest, taking into account investigations at the tricritical point (0.87 K), which represents the junction of a first-order and a second-order transition. Tests in space are needed because gravity-related effects make adequate tests on earth impossible. He-3 refrigeration can be used to attain temperatures below 1 K. Adiabatic demagnetization can produuce temperatures below 0.3 K.

Kittel, P.↗

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.↗

He-3 cooling systems for space

The development of a space-compatible He(3) refrigerator would provide a significant improvement in several areas of research in the 0.3 to 1 K temperature range. There are several methods of achieving these temperatures on Earth: He(3) refrigeration, dilution refrigeration, and adiabatic demagnetization refrigeration. The progress of adapting He(3) refrigeration for use in space is described. Various cycles and possible embodiments of He(3) refrigerators are described. Also included is an analysis of the liquid confinement and liquid-vapor phase-separation system. A possible configuration is then analyzed. Finally, the results of ground-based experiments will be discussed.

Kittel, P.↗

Reciprocating Magnetic Refrigerator

Unit cools to 4 K by adiabatic demagnetization. Two porous matrices of paramagnetic material gadolinium/gallium/garnet held in long piston called displacer, machined out of Micarta (phenol formaldehyde polymer). Holes in side of displacer allow heat-exchange fluid to flow to and through matrices within. Piston seals on displacer prevent substantial mixing of fluid in two loops. Magnetic refrigerator provides continuous rather than "one-shot" cooling.

Johnson, D. L.↗

Hydride absorption refrigerator system for ten Kelvin and below

A very long-life, lightweight and efficient hydride absorption refrigerator system was built to operate at ten Kelvin and below. The system consists of four basic stages of refrigeration. The first stage is accomplished by an active refrigeration system. The second stage is operated by a hydride absorption system, wherein a heated hydride powder drives off high pressure hydrogen through a Joule-Thomson/heat exchanger expansion loop such that the hydrogen is partially liquefied. In the third stage, the vapor pressure over the collected liquid hydrogen is lowered by absorbing the hydrogen vapor onto a different low pressure, worn hydride. With a 1.7 torr partial pressure of hydrogen gas in the hydride, liquid hydrogen is solidified and sublimes at 10 K. Long-life adiabatic demagnetization refrigerators, helium desorption, or helium diaphragm compressors are used to cool to 4 K or below. It is shown that the hydride concepts provide an extremely efficient means of refrigeration to 10 K, and that an entire sorption refrigeration process can be accomplished solely by using low grade heat energy at about 150 C.

Jones, J. A.↗

MIPS - The Multiband Imaging Photometer for SIRTF

The Multiband Imaging Photometer for SIRTF (MIPS) is to be designed to reach as closely as possible the fundamental sensitivity and angular resolution limits for SIRTF over the 3 to 700 micron spectral region. It will use high performance photoconductive detectors from 3 to 200 micron with integrating JFET amplifiers. From 200 to 700 microns, the MIPS will use a bolometer cooled by an adiabatic demagnetization refrigerator. Over much of its operating range, the MIPS will make possible observations at and beyond the conventional Rayleigh diffraction limit of angular resolution.

Rieke, G. H.↗

MIPS - The Multiband Imaging Photometer for SIRTF

The Multiband Imaging Photometer System (MIPS) for SIRTF is to be designed to reach as closely as possible the fundamental sensitivity and angular resolution limits for SIRTF over the 3 to 700 microns spectral region. It will use high performance photoconductive detectors from 3 to 200 microns with integrating JFET amplifiers. From 200 to 700 microns, the MIPS will use a bolometer cooled by an adiabatic demagnetization refrigerator. Over much of its operating range, the MIPS will make possible observations at and beyond the conventional Rayleigh diffraction limit of angular resolution.

Rieke, G. H.↗

Cryogenics program overview

An overview of the cryogenics program of the Goddard Space Flight Center is given in viewgraph form. Goddard's role and the flight programs requiring cryogenics are outlined. Diagrams are given of the Cosmic Background Explorer, the Broad Band X-Ray Telescope, the Hubble Space Telescope, an adiabatic demagnetization refrigerator, a liquid cryogenic cooler for the Shuttle Glow Experiment, a liquid helium dewar, and the X-ray spectrometer on the Advanced X-Ray Astrophysics Facility.

Castles, Stephen H.↗

Ames Research Center cryogenics program

Viewgraphs describe the Ames Research Center's cryogenics program. Diagrams are given of a fluid management system, a centrifugal pump, a flow meter, a liquid helium test facility, an extra-vehicular activity coupler concept, a dewar support with passive orbital disconnect, a pulse tube refrigerator, a dilution refrigerator, and an adiabatic demagnetization cooler.

Kittel, Peter↗

Current developments in NASA cryogenic cooler technology

Cooler technologies that are being developed by NASA to meet the varying temperature and cooling power requirements of NASA instruments are described. In addition to providing the desired operating temperature and cooling power by stabilizing temperatures from room temperature down to 0.1 K or less, these coolers will have working lifetimes commensurate with the 10 to 15 year lifetime expected for major future NASA facilities. The types of coolers currently under development are discussed, including radiative coolers, solid cryogen coolers, surface tension confined liquid cryogen coolers, mechanical coolers, liquid helium dewars, He3 adsorption coolers, adiabatic demagnetization refrigerators, and dilution refrigerators.

Castles, Stephen H.↗

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.↗

A 100 micro Kelvin bolometer system for SIRTF

Progress toward a prototype of 100 mK bolometric detection system for the Space Infrared Telescope Facility (SIRTF) is described. Two adiabatic demagnetization refrigerators (ADR's) were constructed and used to investigate the capabilities necessary for orbital operation. The first, a laboratory ADR, demonstrated a hold time at 0.1 K of over 12 hours, with temperature stability approx. 3 micro-K RMS achieved by controlling the magnetic field. A durable salt pill and an efficient support system have been demonstrated. A second ADR, the SIRTF flight prototype, has been built and will be flown on a balloon. Techniques for magnetic shielding, low heat leak current leads, and a mechanical heat switch are being developed in this ADR. Plans for construction of 100 mK bolometers are discussed. Three important cosmological investigations which will be carried out by these longest wavelength SIRTF detectors are described.

Bernstein, G. M.↗

The cryogenic subsystem for the X-ray spectrometer on the Advanced X-Ray Astrophysics Facility (AXAF)

The X-ray Spectrometer (XRS) instrument on the Advanced X-ray Astrophysics Facility (AXAF) will use X-ray detectors that operate at 0.1 K. The detectors will be maintained at 0.1 K by an Adiabatic Demagnetization Refrigerator (ADR) that operates inside a liquid helium dewar. The ADR rejects approximately 2 mW of heat to the stored liquid helium. With this low instrument heat load, the liquid helium dewar will have a long lifetime if the parasitic heat load on the helium from the surrounding warm facility is minimized. Spaceborne helium dewars typically use up to 3 vapor cooled shields to intercept the parasitic heat load. The XRS will add mechanical coolers to provide additional cooling to the outer vapor cooled shield. The cryogenic system consists of an ADR, a liquid helium dewar, mechanical coolers, and a thermal strap to connect the coolers to the dewar. The lifetime of the stored cryogen is calculated to be up to 5 years. This cryogenic system is described, with particular attention given to the dewar, mechanical cooler, and ADR design, testing, and trade studies. A breadboard ADR is presently being fabricated and tested. The status of the construction and testing of this breadboard will be described.

Castles, Stephen H.↗

Space Cryogenic Workshop, 8th, California Institute of Technology, Pasadena, July 31, Aug. 1, 1989, Proceedings

Recent advances in cryogenic technology for space applications are examined in reviews and reports. Topics addressed include very-low-force cooling contacts for the ISO cryostat cover, convective heat flow in space cryogenics plugs, liquid-acquisition devices for superfluid He transfer, and pressure drop in the SHOOT superfluid-He acquisition system. Consideration is given to a liquid-He vibration cryostat for space qualification tests, closed-cycle coolers for temperatures below 30 K, stress analysis down to liquid-He temperature, a cryogenic valve actuator, and a spaceborne He-3 refrigerator. Also discussed are an adiabatic-demagnetization refrigerator for SIRTF, rejection of waste heat from O liquefaction operations at a lunar O production plant, SHOOT flowmeter and pressure transducers, and space qualification of the ISO cryogenic rupture disks.

Source record↗

Helium 3/Helium 4 dilution cryocooler for space

Prototype dilution cryocoolers based on dilution refrigeration and adiabatic demagnetization refrigeration (ADR) cycles were designed, constructed, and tested. Although devices the devices did not operate as fully functional dilution cryocoolers, important information was gathered. The porous metal phase separator was demonstrated to operate in the -1-g configuration; this phase separation is the critical element in the He-3 circulation dilution cryocooler. Improvements in instrumentation needed for additional tests and development were identified.

Hendricks, John B.↗

Physicists make a difference in space cryogenics

An evaluation is made of space cryogenics technology development challenges in whose treatment the unique abilities of physicists have been notably valuable. In addition to such broad concerns as the quantum properties of superfluid He, the basic laws of thermodynamics and entropy, and quantization of such fields as those of phonons and magnons, productive efforts have been made by physicists in the basic principles of SQUIDs, magnetic shielding due to the Meissner effect in superconductors, adiabatic demagnetization, and dilution cooling of He-3 and He-4. These contributions will be of fundamental importance to the IR Telescope for Space and Advanced X-ray Astronomical Facility, which are currently under development.

Petrac, D.↗