Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACOUSTIC SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterising nuclear simulant suspensions in situ with an acoustic backscatter system

In situ characterisation of radio-toxic sludges and slurries is critical to numerous operations including those involving their transport and retrieval. An inexpensive, flexible acoustic backscatter system has been employed for the first time here to a 4/10. scale active storage tank comprising of a nuclear simulant suspension, to verify its application. Intricate suspension characteristics and tank operation features emerged. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks

Purpose: One of the major issues in high intensity focused ultrasound ablation of abdominal lesions is obstruction of the ultrasound beam by the thoracic cage. Beam shaping strategies have been shown by several authors to increase focal point intensity while limiting rib exposure. However, as rib obstruction leaves only part of the aperture available for energy transmission, conserving total emitted acoustic power, the intensity in the near-field tissues inherently increases after beam shaping. Despite of effective rib sparing, those tissues are therefore subjected to increased risk of thermal damage. In this study, for a number of clinically representative intercostal sonication geometries, modeling clinically available hardware, the effect of beam shaping on both the exposure of the ribs and near-field to acoustic energy was evaluated and the implications for the volumetric ablation rate were addressed. Methods: A relationship between rib temperature rise and acoustic energy density was established by means of in vivo MR thermometry and simulations of the incident acoustic energy for the corresponding anatomies. This relationship was used for interpretation of rib exposure in subsequent numerical simulations in which rib spacing, focal point placement, and the focal point trajectory were varied. The time required to heat a targeted region to 65 °C was determined without and with the application of beam shaping. The required sonication time was used to calculate the acoustic energy density at the fat–muscle interface and at the surface of the ribs. At the fat–muscle interface, exposure was compared to available literature data and rib exposure was interpreted based on the earlier obtained relation between measured temperature rise and simulated acoustic energy density. To estimate the volumetric ablation rate, the cool-down time between periods of energy exposure was estimated using a time-averaged power limit of 100 kJ/h. Results: At the level of the ribs, the temperature rise–energy density proportionality constant was estimated to be 6.0–7.6 °C/(J/mm{sup 2}). Beam shaping by the geometric shadow method typically reduces the acoustic intensity a factor of 2, considering the 1 cm{sup 2} with the highest exposure. For a 4 mm diameter circular sonication trajectory, the near-field energy limit of 2.5 J/mm{sup 2} was exceeded for all considered geometries. The estimated rib temperature was in all but one (sonication 50 mm behind the ribs, with 15 mm rib spacing and a 4 mm diameter circular sonication trajectory) of the considered scenarios within acceptable limits. For those sonication scenarios where a single sonication is considered safe both in terms of near-field as well as rib heating, volumetric ablation rates in the order of 1 ml/h are estimated. Conclusions: Intercostal sonication is associated with an increased risk of near-field overheating. This risk is strongly dependent on the considered rib spacing, the placement of the focus behind the ribs, and the selected sonication trajectory. For the hardware under simulation, obstruction by the thoracic cage renders ablations of clinically relevant volumes within a practical time-frame unfeasible in a large part of the liver. Improvements maybe expected from transducer designs with a larger active surface and/or nonlinear sonication strategies.

60 APPLIED LIFE SCIENCES↗

Particle-in-cell simulation of large amplitude ion-acoustic solitons

The propagation of large amplitude ion-acoustic solitons is studied in the laboratory frame (x, t) using a 1-D particle-in-cell code that evolves the ion dynamics by treating them as particles but assumes the electrons to follow the usual Boltzmann distribution. It is observed that for very low Mach numbers the simulation results closely match the Korteweg-de Vries soliton solutions, obtained in the wave frame, and which propagate without distortion. The collision of two such profiles is observed to exhibit the usual solitonic behaviour. As the Mach number is increased, the given profile initially evolves and then settles down to the exact solution of the full non-linear Poisson equation, which then subsequently propagates without distortion. The fractional change in amplitude is found to increase linearly with Mach number. It is further observed that initial profiles satisfying k{sup 2}λ{sub de}{sup 2}<1 break up into a series of solitons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental evidence of ion acoustic soliton chain formation and validation of nonlinear fluid theory

We perform one-dimensional fluid simulation of ion acoustic (IA) solitons propagating parallel to the magnetic field in electron-ion plasmas by assuming a large system length. To model the initial density perturbations (IDP), we employ a KdV soliton type solution. Our simulation demonstrates that the generation mechanism of IA solitons depends on the wavelength of the IDP. The short wavelength IDP evolve into two oppositely propagating identical IA solitons, whereas the long wavelength IDP develop into two indistinguishable chains of multiple IA solitons through a wave breaking process. The wave breaking occurs close to the time when electrostatic energy exceeds half of the kinetic energy of the electron fluid. The wave breaking amplitude and time of its initiation are found to be dependent on characteristics of the IDP. The strength of the IDP controls the number of IA solitons in the solitary chains. The speed, width, and amplitude of IA solitons estimated during their stable propagation in the simulation are in good agreement with the nonlinear fluid theory. This fluid simulation is the first to confirm the validity of the general nonlinear fluid theory, which is widely used in the study of solitary waves in laboratory and space plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multicomponent kinetic simulation of Bernstein–Greene–Kruskal modes associated with ion acoustic and dust-ion acoustic excitations in electron-ion and dusty plasmas

A series of numerical simulations based on a recurrence-free Vlasov kinetic algorithm presented earlier [Abbasi et al., Phys. Rev. E 84, 036702 (2011)] are reported. Electron-ion plasmas and three-component (electron-ion-dust) dusty, or complex, plasmas are considered, via independent simulations. Considering all plasma components modeled through a kinetic approach, the nonlinear behavior of ionic scale acoustic excitations is investigated. The focus is on Bernstein–Greene–Kruskal (BGK) modes generated during the simulations. In particular, we aim at investigating the parametric dependence of the characteristics of BGK structures, namely of their time periodicity (τ{sub trap}) and their amplitude, on the electron-to-ion temperature ratio and on the dust concentration. In electron-ion plasma, an exponential relation between τ{sub trap} and the amplitude of BGK modes and the electron-to-ion temperature ratio is observed. It is argued that both characteristics, namely, the periodicity τ{sub trap} and amplitude, are also related to the size of the phase-space vortex which is associated with BGK mode creation. In dusty plasmas, BGK modes characteristics appear to depend on the dust particle density linearly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large eddy simulations of a transcritical round jet submitted to transverse acoustic modulation

This article reports numerical computations of a turbulent round jet of transcritical fluid (low temperature nitrogen injected under high pressure conditions) surrounded by the same fluid at rest under supercritical conditions (high temperature and high pressure) and submitted to transverse acoustic modulations. The numerical framework relies on large eddy simulation in combination with a real-gas description of thermodynamics and transport properties. A stationary acoustic field is obtained by modulating the normal acoustic velocity at the lateral boundaries of the computational domain. This study specifically focuses on the interaction of the jet with the acoustic field to investigate how the round transcritical jet changes its shape and mixes with the surrounding fluid. Different modulation amplitudes and frequencies are used to sweep a range of conditions. When the acoustic field is established in the domain, the jet length is notably reduced and the jet is flattened in the spanwise direction. Two regimes of oscillation are identified: for low Strouhal numbers a large amplitude motion is observed, while for higher Strouhal numbers the jet oscillates with a small amplitude around the injector axis. The minimum length is obtained for a Strouhal number of 0.3 and the jet length increases with increasing Strouhal numbers after reaching this minimum value. The mechanism of spanwise deformation is shown to be linked with dynamical effects resulting from reduction of the pressure in the transverse direction in relation with increased velocities on the two sides of the jet. A propagative wave is then introduced in the domain leading to similar effects on the jet, except that a bending is also observed in the acoustic propagation direction. A kinematic model, combining hydrodynamic and acoustic contributions, is derived in a second stage to represent the motion of the jet centerline. This model captures details of the numerical simulations quite well. These various results can serve to interpret observations made on more complex flow configurations such as coaxial jets or jet flames formed by coaxial injectors.

42 ENGINEERING↗

Detection, monitoring, and determination of location of changes in metallic structures using multimode acoustic signals

Acoustic transducers generate and receive acoustic signals at multiple locations along a surface of rigid structure, wherein longitudinal spacing between transducer locations define measurement zones. Acoustic signals with chosen amplitude-time-frequency characteristics excite multiple vibration modes in the structure within each zone. Small mechanical changes in inspection zones lead to scattering and attenuation of broadband acoustic signals, which are detectable as changes in received signal characteristics as part of a through-transmission technique. Additional use of short, narrowband pulse acoustic signals as part of a pulse-echo technique allows determination of the relative location of the mechanical change within each zone based on the differential delay profiles. For accurate acoustic modeling and simulation, the mesh size, time step, time delay, and time-window size are optimized. Frequency normalization of the Short-Time Fourier Transform of acoustic response output improves experiment-simulation cross-validation. Applications of the method to structures with arbitrarily complex geometries are also demonstrated.

Findikoglu, Alp Tugrul↗

Simulation of Wave Propagation for Nuclear Facility Acoustic Communications

Elastic waves are often used in non-destructive testing (NDT) to detect material defects in metal pipes. In NDT methodology, high-frequency elastic waves are launched into a pipe with an ultrasonic transducer. Material defects comparable in size to wavelength scatter ultrasonic waves, and analysis of scattered signal allows quantifying the defect and its location. As a variation of NDT technology, ultrasonic transducers placed at the ends of a pipe, and operating at wavelengths larger than typical micro-crack sizes, can act as a transmitter and receiver of information. By modulating transducer signal to send information encoded with elastic waves across a metal pipe, we attempt to create a communication channel. By taking advantage of existing piping infrastructure of thermal hydraulic systems, such communication links would allow the transmission of information across physical barriers in a nuclear facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced focus steering abilities of multi-element therapeutic arrays operating in nonlinear regimes

Steering abilities of a typical HIFU therapeutic array operated in linear and nonlinear regimes were compared using numerical simulation with the 3D Westervelt equation. The array included 256 elements of 1.2 MHz frequency and 6.6 mm diameter distributed in a quasi-random pattern over a spherical shell with a 130 mm aperture and a focal length of 120 mm. In the case of linear focusing, thermal effects are proportional to the intensity level and the criterion for safe array operation is that the intensity in the grating lobes should be less than 10% of the intensity in the main focus. In the case of nonlinear focusing, the heating effect is no longer proportional to intensity; therefore the heat deposition rate was chosen as the relevant metric, using the same 10% threshold for the secondary lobe in comparison with the focal maximum. When steering the focus, the same linearly predicted intensity level at the main focus was maintained by increasing the array power. Numerical simulations of the acoustic field were performed for nonlinear propagation both in water and in tissue. It was shown that for shock-forming conditions in the main focus, the steering range of safe electronic focusing is larger than that for linear propagation conditions. Nonlinear sonication regimes therefore can be used to enlarge tissue volumes that can be sonicated using electronic steering of the focus of HIFU arrays.

42 ENGINEERING↗

Trapped electron damping of geodesic acoustic mode

Global gyrokinetic particle simulation finds that the collisionless damping rate of the geodesic acoustic mode (GAM) in tokamak is greatly enhanced by trapped electrons in the high-q region of tokamak (q is the safety factor). The electron damping has been identified to arise from the resonance of the GAM oscillation with the trapped electron bounce motion. The contribution of passing electrons to the GAM collisionless damping is much smaller than the trapped electrons. The residual level of the zonal flow is not sensitive to the trapped electron resonance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simulation technique for 3D MR-guided acoustic radiation force imaging

Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) therapies, the in situ characterization of the focal spot location and quality is critical. MR acoustic radiation force imaging (MR-ARFI) is a technique that measures the tissue displacement caused by the radiation force exerted by the ultrasound beam. This work presents a new technique to model the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model. Methods: When a steady-state point-source force acts internally in an infinite homogeneous medium, the displacement of the material in all directions is given by the Somigliana elastostatic tensor. The radiation force field, which is caused by absorption and reflection of the incident ultrasound intensity pattern, will be spatially distributed, and the tensor formulation takes the form of a convolution of a 3D Green’s function with the force field. The dynamic accumulation of MR phase during the ultrasound pulse can be theoretically accounted for through a time-of-arrival weighting of the Green’s function. This theoretical model was evaluated experimentally in gelatin phantoms of varied stiffness (125-, 175-, and 250-bloom). The acoustic and mechanical properties of the phantoms used as parameters of the model were measured using independent techniques. Displacements at focal depths of 30- and 45-mm in the phantoms were measured by a 3D spin echo MR-ARFI segmented-EPI sequence. Results: The simulated displacements agreed with the MR-ARFI measured displacements for all bloom values and focal depths with a normalized RMS difference of 0.055 (range 0.028–0.12). The displacement magnitude decreased and the displacement pattern broadened with increased bloom value for both focal depths, as predicted by the theory. Conclusions: A new technique that models the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model theory has been rigorously validated through comparison with experimentally obtained 3D displacement data in homogeneous gelatin phantoms using a 3D MR-ARFI sequence. The agreement of the experimentally measured and simulated results demonstrates the potential to use MR-ARFI displacement data in MRgFUS therapies.

60 APPLIED LIFE SCIENCES↗

Paracousti User Guide

Paracousti is a parallelized acoustic wave propagation simulation package developed at Sandia National Laboratories. It solves the linearized coupled set of acousto-dynamic partial differential equations using finite-difference approximations that are second order accurate in time and fourth order accurate in space. Paracousti simulates sound wave propagation within realistic 3-D earth, static atmosphere and hydroacoustic models, including 3-D variations in medium densities and acoustic sound speeds and topography or bathymetry. It can also incorporate attenuative media such as would be expected from physical mechanisms such as molecular dissipation. This report explains the usage of the Paracousti algorithm.

47 OTHER INSTRUMENTATION↗

MO-A-BRD-07: Feasibility of X-Ray Acoustic Computed Tomography as a Tool for Calibration and In Vivo Dosimetry of Radiotherapy Electron and Photon Beams

Purpose: This work simulates radiation-induced acoustic waves to assess the feasibility of x-ray acoustic computed tomography (XACT) as a dosimeter. XACT exploits the phenomenon that acoustic waves with amplitude proportional to the dose deposited are induced following a radiation pulse. After detecting these acoustic waves with an ultrasound transducer, an image of the dose distribution can be reconstructed in realtime. Methods: Monte Carlo was used to simulate the dose distribution for monoenergetic 6 MeV photon and 9 MeV electron beams incident on a water tank. The dose distribution for a prostate patient planned with a photon 4-field box technique was calculated using clinical treatment planning software. All three dose distributions were converted into initial pressure distributions, and transportation of the induced acoustic waves was simulated using an open-source toolkit. Ideal transducers were placed around the circumference of the target to detect the acoustic waves, and a time reversal reconstruction algorithm was used to obtain an XACT image of the dose for each radiation pulse. Results: For the photon water tank relative dosimetry case, it was found that the normalized acoustic signal amplitude agreed with the normalized dose at depths from 0 cm to 10 cm, with an average percent difference of 0.5%. For the reconstructed in-plane dose distribution of an electron water tank irradiation, all pixels passed a 3%–3 mm 2D gamma test. The reconstructed prostate dose distribution closely resembled the plan, with 89% of pixels passing a 3%–3 mm 2D gamma test. For all situations, the amplitude of the induced acoustic waves ranged from 0.01 Pa to 1 Pa. Conclusion: Based on the amplitude of the radiation-induced acoustic waves and accuracy of the reconstructed dose distributions, XACT is a feasible technique for dosimetry in both calibration and in vivo environments for photon and electron beams and merits further investigation. Funding from NSERC, CIHR and McGill University. SH acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Mechanochemically responsive polymer enables shockwave visualization

Abstract Understanding the physical and chemical response of materials to impulsive deformation is crucial for applications ranging from soft robotic locomotion to space exploration to seismology. However, investigating material properties at extreme strain rates remains challenging due to temporal and spatial resolution limitations. Combining high-strain-rate testing with mechanochemistry encodes the molecular-level deformation within the material itself, thus enabling the direct quantification of the material response. Here, we demonstrate a mechanophore-functionalized block copolymer that self-reports energy dissipation mechanisms, such as bond rupture and acoustic wave dissipation, in response to high-strain-rate impacts. A microprojectile accelerated towards the polymer permanently deforms the material at a shallow depth. At intersonic velocities, the polymer reports significant subsurface energy absorption due to shockwave attenuation, a mechanism traditionally considered negligible compared to plasticity and not well explored in polymers. The acoustic wave velocity of the material is directly recovered from the mechanochemically-activated subsurface volume recorded in the material, which is validated by simulations, theory, and acoustic measurements. This integration of mechanochemistry with microballistic testing enables characterization of high-strain-rate mechanical properties and elucidates important insights applicable to nanomaterials, particle-reinforced composites, and biocompatible polymers.

Science & Technology - Other Topics↗

Localization and implication of oblique whistler wave in the magnetopause region

Nonlinear interaction between highly oblique whistler wave and ion acoustic wave pertinent to magnetopause has been investigated. The density perturbation in whistler wave is supposed to be originated due to the presence of ion acoustic wave in the background. The ponderomotive force components arising due to the high amplitude pump wave, viz., whistler wave are constituted in the nonlinear dynamics of low frequency ion acoustic wave. The coupled nonlinear dynamical equations are then modelled in the form of modified nonlinear Schrödinger equation by considering adiabatic response of low frequency ion acoustic wave. The numerical simulation of this coupled nonlinear equation is performed to study the temporal evolution of nonlinear whistler wave. The obtained simulation results show that the temporal evolution also leads to the cascade of broadband turbulence spectrum at smaller wavelengths. The relevance of the obtained results with the observations of THEMIS spacecraft in the magnetopause region has been pointed out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron and ion kinetic effects on non-linearly driven electron plasma and ion acoustic waves

Fully non-linear kinetic simulations of electron plasma and ion acoustic waves (IAWs) have been carried out with a new multi-species, parallelized Vlasov code. The numerical implementation of the Vlasov model and the methods used to compute the wave frequency are described in detail. For the first time, the nonlinear frequency of IAWs, combining the contributions from electron and ion kinetic effects and from harmonic generation, has been calculated and compared to Vlasov results. Excellent agreement of theory with simulation results is shown at all amplitudes, harmonic generation being an essential component at large amplitudes. For IAWs, the positive frequency shift from trapped electrons is confirmed and is dominant for the effective electron-to-ion temperature ratio, Z T{sub e}/T{sub i} Greater-Than-Or-Equivalent-To 10 with Z as the charge state. Furthermore, numerical results demonstrate unambiguously the dependence [R. L. Dewar, Phys. Fluids 15, 712 (1972)] of the kinetic shifts on details of the distribution of the trapped particles, which depends in turn on the conditions under which the waves were generated. The trapped particle fractions and energy distributions are derived and, upon inclusion of harmonic effects, shown to agree with the simulation results, completing a consistent picture. Fluid models of the wave evolution are considered but prove unable to capture essential details of the kinetic simulations. Detrapping by collisions and sideloss is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗