Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Investigating the History of Aubrites Using X-Ray Computed Tomography and Bulk Partition Coefficients

The aubrites are a unique group of differentiated meteorites that formed on parent bodies with oxygen fugacities (ƒO2) from ~2 to ~6 log units below the iron-wustite buffer. At these highly reduced condi- tions, elements deviate from the geochemical behavior exhibited at terrestrial ƒO2, and may form FeO-poor silicates, Si-bearing metals, and exotic sulfides. Geochemical examinations of aubrites, such as mineral major-element compositions, bulk-rock compositions, O isotopes, and crystallization ages, are crucial to understand their formation and evolution at extreme ƒO2 conditions. In this study, we determine partitioning relationships of elements between bulk silicate, sulfide, and metal phases within aubrites, and compare the results to partition coefficients determined from petrologic experiments run under mercurian conditions. While previous studies have described the petrology and 2D modal abundances of aubrites, this work provides the first 3D view of aubritic mineralogies, which are com- pared to the available 2D data. Constraints of 3D modal abundances will increase the accuracy of computed bulk distribution coefficients; therefore, 3D scans of aubrite samples are imperative. We utilize X-ray computed tomogra- phy (XCT) to non-destructively analyze the distribution and abundances of mineral phases in aubrites and locate composite clasts of sulfide grains for future analysis.

Wilbur, Z. E.↗

Large-Drop Ice Accretion Test Results for a Large Scale Swept Wing Model

In-flight icing is an important consideration that affects aircraft design, performance and safety. Newer regulations combined with increasing demand to reduce fuel burn, emissions and noise are driving a need for improvements in icing simulation capability. To that end, this paper presents the results of ice accretion testing conducted in the NASA Icing Research Tunnel on a large swept wing section typical of a modern commercial transport. The model was based upon a section of the Common Research Model wing at the 64% semispan station with a streamwise chord length of 136 in. The test conditions were developed with an icing scaling analysis to generate similar conditions for a small MVD = 25 μm and a large MVD = 110 μm. A series of tests were conducted over a range of total temperature from -23.8 ˚C to -1.4 ˚C with all other conditions held constant. The results for the small MVD cloud conditions were consistent with previous work and showed the changing ice morphology from rime ice at colder temperatures to highly 3D scallop ice in the range of -8.7 ˚C to -3.8 ˚C. The results for the large MVD cloud conditions exhibited some differences in the ice accretion morphology from the small MVD conditions. Scallop-like ice features were observed at total temperature of -3.8˚C. The large MVD ice accretion at lower temperatures tended to be smoother than the corresponding ice accretion for small MVD. The thickness of the main ice shape tended to be larger for the small MVD conditions compared to the corresponding large MVD ice shape while the latter had more ice farther downstream. The measured ice mass was approximately equal between the corresponding small and large MVD ice shapes up to a freezing fraction of 0.6. For higher freezing fraction, the large MVD ice shapes weighed more. Cloud MVD variation from 50 μm to 230 μm while holding the scaling parameters constant resulted in very minor differences in the ice shapes, mostly in the upper and lower surface chordwise extents. Ice volume was computed from 3D scan data and used to calculate a ratio of ice mass to volume. The resulting values were in the range of 240 to 455 Kg/m3. While this is consistent with analogous values previously reported in the literature, more data are needed to determine a specific trend in this ratio as a function of freezing fraction and the corresponding governing physical phenomena. This work has resulted in a significant experimental database of ice accretion for small and large MVD conditions applicable to large-scale swept wings.

Icing↗

Large-Drop Ice Accretion Test Results for a Large Scale Swept Wing Section

In-flight icing is an important consideration that affects aircraft design, performance and safety. Newer regulations combined with increasing demand to reduce fuel burn, emissions and noise are driving a need for improvements in icing simulation capability. To that end, this paper presents the results of ice accretion testing conducted in the NASA Icing Research Tunnel on a large swept wing typical of a modern commercial transport. The model was based upon a section of the Common Research Model wing at the 64% semispan station with a streamwise chord length of 136 in. The test conditions were developed with an icing scaling analysis to generate similar conditions for a small MVD = 25 μm and a large MVD = 110 μm. A series of tests were conducted over a range of total temperature from -23.8 ˚C to -1.4 ˚C with all other conditions held constant. The results for the small MVD cloud conditions were consistent with previous work and showed the changing ice morphology from rime ice at colder temperatures to highly 3D scallop ice in the range of -8.7 ˚C to -3.8 ˚C. The results for the large MVD cloud conditions exhibited some differences in the ice accretion morphology. Scallop-like ice features were observed at total temperature of -3.8˚C. The large MVD ice accretion at lower temperatures tended to be smoother than the corresponding ice accretion for small MVD. The thickness of the main ice shape tended to be larger for the small MVD conditions compared to the corresponding large MVD ice shape while the latter had more ice farther downstream. The measured ice mass was approximately equal between the corresponding small and large MVD ice shapes up to a freezing fraction of 0.6. For higher freezing fraction, the large MVD ice shapes weighed more. Cloud MVD variation from 50 μm to 230 μm while holding the scaling parameters constant resulted in very minor differences in the ice shapes, mostly in the upper and lower surface chordwise extents. Ice volume was computed from 3D scan data and used to calculate a ratio of ice mass to volume. The resulting values were in the range of 240 to 455 Kg/m3. While this is consistent with analogous values previously reported in the literature, more data are needed to determine a specific trend in this ratio as a function of freezing fraction and the corresponding governing physical phenomena. This work has resulted in a significant experimental database of ice accretion for small and large MVD conditions applicable to large-scale swept wings.

Icing↗

Astrobee: Five years of Completed, Current, and Future Research on the International Space Station using Free Flying Robots.

After five years on the International Space Station (ISS), the Astrobee Research Facility, has completed over 160 Test Sessions logging over 1200 hours of operations. Managed by the NASA ISS Program OZ office and supported by NASA Ames Research Center (ARC) in California, the Astrobee Team currently maintains two identical free-flying Astrobee robots and a Docking Station for research on the ISS. As a technology demonstration platform, the Astrobee Robots are available for Guest Scientists to use for a spectrum of research capabilities. Using ambient air on the ISS, propelled by battery-operated fans, Astrobee is designed to autonomously operate throughout most of the USOS (US Orbital Segment), with the objective of minimizing the need for astronaut support. Astrobee carries a suite of six cameras, a two degree-of-freedom (DOF) arm with a gripper that can grasp ISS handrails and other objects, and three payload bays that provide power and data for guest science hardware. Astrobee can autonomously execute hours-long flight plans or be tele-operated from the ground. While the Astrobee Team continues to improve mapping and autonomous flight capabilities, one of the main goals of Astrobee Robots is to provide research opportunities for Guest Scientists. The Astrobee Robot Software (ARS) makes extensive use of the open-source Robot Operating System (ROS). The ARS can be used interchangeably with an Astrobee Simulator or as Astrobee’s onboard software. ARS features include autonomous docking and perching, real-time teleoperations from the ground, plan based autonomous tasks, multi Astrobee communication, among other capabilities. Through simulation software and ground testing laboratories, the Astrobee Team is available to support Guest Scientists during development and testing and lead real-time ISS operations. The Astrobee Team and Guest Scientists have completed research including Astrobatics maneuvers, RFID and sound sensing capabilities, Gecko materials studies, student Robotics Programming Challenges, and Free Flyer formation flight investigations. Current science with the Astrobee Robots is investigating new docking capabilities through software only research as well as testing new docking hardware installed on the Astrobees. The Astrobee Team and other researchers at NASA Ames continue to explore robotics applications for future NASA missions such as Gateway and potential experiments involving human-robot interactions. Continued advanced mapping resolution capabilities, and high-resolution panoramic imagery also remains areas of research. Exciting in development research involves docking for rendezvous proximity operation (CLINGERS), multi resolution 3D scanning (MRS), space debris removal in microgravity (REACCH). This presentation will mainly focus on completed research over the past year and current science being performed on the Astrobees. This presentation will also focus on how a Guest Scientist/Researcher progresses from conception to running their science on the Astrobees on the ISS, as well as discuss the Astrobee Facility resources available for supporting ground testing and real-time ISS operations.

Astrobee↗

Physics-based Simulation of Human Posture Using 3D Whole Body Scanning Technology for Astronaut Space Suit Evaluation

Over the past few years high precision three-dimensional (3D) full body laser scanners have been developed to be used as a powerful anthropometry tool for quantification of the morphology of the human body. The full body scanner can quickly extract body characteristics in non-contact fashion. It is required for the Anthropometry and Biomechanics Facility (ABF) to have capabilities for kinematics simulation of a digital human at various postures whereas the laser scanner only allows capturing a single static posture at each time. During this summer fellowship period a theoretical study has been conducted to estimate an arbitrary posture with a series of example postures through finite element (FE) approximation and found that four-point isoparametric FE approximation would result in reasonable maximum position errors less than 5%. Subsequent pilot scan experiments demonstrated that a bead marker with a nominal size of 6 mm could be used as a marker for digitizing 3-D coordinates of anatomical landmarks for further kinematic analysis. Two sessions of human subject testing were conducted for reconstruction of an arbitrary postures from a set of example postures for each joint motion for the forearm/hand complex and the whole upper extremity.

Kim, Kyu-Jung↗

Final Report – Study of Shortwave Spectra in Fully 3D Environment. Synergy Between Scanning Radars and Spectral Radiation Measurements

ARM set out 20 years ago to “close” the radiation problem, that is, to improve radiation models to the point where they could routinely predict the observed spectral radiation fluxes knowing the optical properties of the surface and of gases, clouds and aerosols in the atmosphere. Only then could such radiation models form a proper springboard for global climate model (GCM) parameterizations of spectral radiation. Sustained efforts have more or less achieved that goal with regard to longwave radiation; ASR models now routinely predict ARM spectral longwave radiances to 1–2%. Similar efforts in the shortwave have achieved far less; the successes are mainly for carefully selected 1D stratiform cloud cases. Such cases amount, even with the most optimistic interpretation, to no more than 30% of all cases at SGP. The problem has not been lack of effort but lack of appropriate instruments.The new ARM stimulus-funded instruments, with their new capabilities, will dramatically improve this situation and once again make progress possible on the shortwave problem. The new shortwave spectrometers will provide a reliable, calibrated record including the near infrared – and for other climatic regimes than SGP. The new scanning radars will provide the 3D cloud view, making it possible to tackle fully 3D situations. Thus, our main theme for the project is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars and shortwave spectrometers with the arsenal of radiative transfer tools.

54 ENVIRONMENTAL SCIENCES↗

Focused Electron Beam-Based 3D Nanoprinting for Scanning Probe Microscopy: A Review

Scanning probe microscopy (SPM) has become an essential surface characterization technique in research and development. By concept, SPM performance crucially depends on the quality of the nano-probe element, in particular, the apex radius. Now, with the development of advanced SPM modes beyond morphology mapping, new challenges have emerged regarding the design, morphology, function, and reliability of nano-probes. To tackle these challenges, versatile fabrication methods for precise nano-fabrication are needed. Aside from well-established technologies for SPM nano-probe fabrication, focused electron beam-induced deposition (FEBID) has become increasingly relevant in recent years, with the demonstration of controlled 3D nanoscale deposition and tailored deposit chemistry. Moreover, FEBID is compatible with practically any given surface morphology. In this review article, we introduce the technology, with a focus on the most relevant demands (shapes, feature size, materials and functionalities, substrate demands, and scalability), discuss the opportunities and challenges, and rationalize how those can be useful for advanced SPM applications. As will be shown, FEBID is an ideal tool for fabrication/modification and rapid prototyping of SPM-tipswith the potential to scale up industrially relevant manufacturing.

36 MATERIALS SCIENCE↗

SU-E-J-164: An Investigation of a Low-Cost ‘dry’ Optical-CT Scanning System for 3D Dosimetry

Purpose: To characterize and explore the efficacy of a novel low-cost, lowfluid, broad-beam optical-CT system for 3D-dosimetry in radiochromic Presage dosimeters. Leading current optical-CT systems incorporate expensive glass-based telecentric lens technology, and a fluid bath with substantial amounts of fluid (which introduces an inconvenience factor) to minimize refraction artifacts. Here we introduce a novel system which addresses both these limitations by: (1) the use of Fresnel lenses in a telecentric arrangement, and (2) a ‘solid’ fluid bath which dramatically reduces the amount of fluid required for refractive-index (RI) matching. Materials Methods: A fresnel based telecentric optical-CT system was constructed which expands light from a single red LED source into a nominally parallel beam into which a cubic ‘dry-tank’ is placed. The drytank consists of a solid polyurethane cube (with the same RI as Presage) but containing a cylindrical cavity (11.5cm diameter × 11cm ) into which the dosimeter is placed for imaging. A narrow (1-3mm) gap between the walls of the dosimeter and dry-tank is filled with a fluid of similar RI. This arrangement reduces the amount of RI fluid from about 1000cc to 75cc, yielding substantial practical benefit in convenience and cost. The new system was evaluated in direct comparison against Eclipse planning system from a 4-field parallel-opposed treatmen Results: Gamma calculations of dose from DFOS-dry system versus Eclipse showed 92% and 97% agreement with 4mm/4% and 5mm/5% criteria, respectively, in the central 80% of dose distribution. Reconstructions showed some edge artifacts, as well as some dose underestimation towards the dosimeter edge. Conclusion: The implementation of Fresnel based ‘dry’ optical-CT for 3Ddosimetry would represent an important advance enhancing costeffectiveness and practical viability. The performance of the prototype presented here is not yet comparable to the state-of-the-art, but shows sufficient promise for further investigation to elevate image quality to match gold-standard optical-CT systems. This work was supported by NIH R01CA100835.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a 3D optical scanning-based automatic quality assurance system for proton range compensators

Purpose: A new automatic quality assurance (AutoRCQA) system using a three-dimensional scanner (3DS) with system automation was developed to improve the accuracy and efficiency of the quality assurance (QA) procedure for proton range compensators (RCs). The system performance was evaluated for clinical implementation. Methods: The AutoRCQA system consists of a three-dimensional measurement system (3DMS) based on 3DS and in-house developed verification software (3DVS). To verify the geometrical accuracy, the planned RC data (PRC), calculated with the treatment planning system (TPS), were reconstructed and coregistered with the measured RC data (MRC) based on the beam isocenter. The PRC and MRC inner surfaces were compared with composite analysis (CA) using 3DVS, using the CA pass rate for quantitative analysis. To evaluate the detection accuracy of the system, the authors designed a fake PRC by artificially adding small cubic islands with side lengths of 1.5, 2.5, and 3.5 mm on the inner surface of the PRC and performed CA with the depth difference and distance-to-agreement tolerances of [1 mm, 1 mm], [2 mm, 2 mm], and [3 mm, 3 mm]. In addition, the authors performed clinical tests using seven RCs [computerized milling machine (CMM)-RCs] manufactured by CMM, which were designed for treating various disease sites. The systematic offsets of the seven CMM-RCs were evaluated through the automatic registration function of AutoRCQA. For comparison with conventional technique, the authors measured the thickness at three points in each of the seven CMM-RCs using a manual depth measurement device and calculated thickness difference based on the TPS data (TPS-manual measurement). These results were compared with data obtained from 3DVS. The geometrical accuracy of each CMM-RC inner surface was investigated using the TPS data by performing CA with the same criteria. The authors also measured the net processing time, including the scan and analysis time. Results: The AutoRCQA system accurately detected all fake objects in accordance with the given criteria. The median systematic offset of the seven CMM-RCs was 0.08 mm (interquartile range: −0.25 to 0.37 mm) and −0.08 mm (−0.58 to 0.01 mm) in the X- and Y-directions, respectively, while the median distance difference was 0.37 mm (0.23–0.94 mm). The median thickness difference of the TPS-manual measurement at points 1, 2, and 3 was −0.4 mm (−0.4 to −0.2 mm), −0.2 mm (−0.3 to 0.0 mm), and −0.3 mm (−0.6 to −0.1 mm), respectively, while the median difference of 3DMS was 0.0 mm (−0.1 to 0.2 mm), 0.0 mm (−0.1 to 0.3 mm), and 0.1 mm (−0.1 to 0.2 mm), respectively. Thus, 3DMS showed slightly better values compared to the manual measurements for points 1 and 3 in statistical analysis (p < 0.05). The average pass rate of the seven CMM-RCs was 97.97% ± 1.68% for 1-mm CA conditions, increasing to 99.98% ± 0.03% and 100% ± 0.00% for 2- and 3-mm CA conditions, respectively. The average net analysis time was 18.01 ± 1.65 min. Conclusions: The authors have developed an automated 3DS-based proton RC QA system and verified its performance. The AutoRCQA system may improve the accuracy and efficiency of QA for RCs.

07 ISOTOPE AND RADIATION SOURCES↗

How to Create a 3D Model from Scanned Data in 5 Easy Steps

Additive manufacturing is a cost effective way to generate copies of damaged parts for demonstrations. Integrating scanned data of a damaged area into an existing model may be challenging. However, using the relatively inexpensive Nettfab software (from one can generate a "watertight" model that is easy to print.

Hagen, Richard↗

Template-based CTA to x-ray angio rigid registration of coronary arteries in frequency domain with automatic x-ray segmentation

Purpose: A key challenge for image guided coronary interventions is accurate and absolutely robust image registration bringing together preinterventional information extracted from a three-dimensional (3D) patient scan and live interventional image information. In this paper, the authors present a novel scheme for 3D to two-dimensional (2D) rigid registration of coronary arteries extracted from preoperative image scan (3D) and a single segmented intraoperative x-ray angio frame in frequency and spatial domains for real-time angiography interventions by C-arm fluoroscopy.Methods: Most existing rigid registration approaches require a close initialization due to the abundance of local minima and high complexity of search algorithms. The authors' method eliminates this requirement by transforming the projections into translation-invariant Fourier domain for estimating the 3D pose. For 3D rotation recovery, template Digitally Reconstructed Radiographs (DRR) as candidate poses of 3D vessels of segmented computed tomography angiography are produced by rotating the camera (image intensifier) around the DICOM angle values with a specific range as in C-arm setup. The authors have compared the 3D poses of template DRRs with the segmented x-ray after equalizing the scales in three domains, namely, Fourier magnitude, Fourier phase, and Fourier polar. The best rotation pose candidate was chosen by one of the highest similarity measures returned by the methods in these domains. It has been noted in literature that frequency domain methods are robust against noise and occlusion which was also validated by the authors' results. 3D translation of the volume was then recovered by distance-map based BFGS optimization well suited to convex structure of the authors' objective function without local minima due to distance maps. A novel automatic x-ray vessel segmentation was also performed in this study.Results: Final results were evaluated in 2D projection space for patient data; and with ground truth values and landmark distances for the images acquired with a solid phantom vessel. Results validate that rotation recovery in frequency domain is robust against differences in segmentations in two modalities. Distance-map translation is successful in aligning coronary trees with highest possible overlap.Conclusions: Numerical and qualitative results show that single view rigid alignment in projection space is successful. This work can be extended with multiple views to resolve depth ambiguity and with deformable registration to account for nonrigid motion in patient data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual Fit Assessment: Validation using Historical Spacesuit Fit Data

Virtual fit tests using 3D body scans have provided a cost-effective means to predictively assess spacesuit fit for the current and future astronaut population. However, fit is a complex issue influenced by physical interferences, subjective preference, and many other factors. Fit can substantially differ between the type of hardware, environmental conditions, and tasks being performed. Namely, fit changes across different contexts, such as 3D printed mockup evaluations, pressurized one-g suited test events, neutral buoyancy and other training events, and flight extravehicular activities (EVA). These challenges make it difficult to validate virtual fit frameworks to physical suit sizing. This study proposes a new method of validation using the wealth of historically archived suit fit data. Physically Assessed Fit (PAF) data was assessed from astronauts and test volunteers who wore the legacy Extravehicular Mobility Unit (EMU). The data was collected during the past decades at NASA and considered to be most reliable and dependable. Each participant was 3D scanned for body shape and spacesuit-critical dimensions were measured per NASA guidelines. The participants’ size preference for hard upper torso (HUT) assembly was retrieved from their pressurized suit fit check records. Fit assessments were also updated after one-g EVA training, neutral buoyancy training, and EVA flights. Virtually Assessed Fit (VAF) was done by overlaying the CAD model of a HUT with the 3D body scans of the PAF participants. Each body scan was iteratively adjusted for the position inside the HUT to minimize the suit-to-body contact interference while satisfying a set of prescribed requirements. Then the residual contact area, depth, and volume were quantified as VAF metrics. This process was repeated for the different HUT sizes, including medium, large, and extra-large. Statistical modeling is currently in progress and will be presented at the conference. A statistical classifier will be developed to predict a fit probability for different HUT sizes as a function of the corresponding person’s VAF metrics. The HUT size with the highest fit probability will constitute the most likely size selection for the person, and the prediction will be compared against the corresponding PAF data. The participant data will be randomly pre-grouped into either a model development or validation subset. While the model development subset will be used to build the probability model, the validation subset will be used to assess the model accuracy. Also, the locations and magnitudes of suit-body-contacts will be estimated from VAF. This information can identify the critical suit geometry and body shape features that influence suit fit. The variations found in PAF size selections by subjects with similar VAF metrics will allow for investigations into subjective preferences, for example, tight versus loose fit. Overall, this study is expected to provide a structured validation of a virtual suit fit framework, which has not been possible in the past. The outcome can also provide useful insights and potential limitations for interpreting virtual fit tests for future spacesuit designs and population accommodation.

Han Kim↗

SU-C-213-01: 3D Printed Patient Specific Phantom Composed of Bone and Soft Tissue Substitute Plastics for Radiation Therapy

Purpose: 3D printed phantoms constructed of multiple tissue approximating materials could be useful in both clinical and research aspects of radiotherapy. This work describes a 3D printed phantom constructed with tissue substitute plastics for both bone and soft tissue; air cavities were included as well. Methods: 3D models of an anonymized nasopharynx patient were generated for air cavities, soft tissues, and bone, which were segmented by Hounsfield Unit (HU) thresholds. HU thresholds were chosen to define air-to-soft tissue boundaries of 0.65 g/cc and soft tissue-to-bone boundaries of 1.18 g/cc based on clinical HU to density tables. After evaluation of several composite plastics, a bone tissue substitute was identified as an acceptable material for typical radiotherapy x-ray energies, composed of iron and PLA plastic. PET plastic was determined to be an acceptable soft tissue substitute. 3D printing was performed on a consumer grade dual extrusion fused deposition model 3D printer. Results: MVCT scans of the 3D printed heterogeneous phantom were acquired. Rigid image registration of the patient and the 3D printed phantom scans was performed. The average physical density of the soft tissue and bone regions was 1.02 ± 0.08 g/cc and 1.39 ± 0.14 g/cc, respectively, for the patient kVCT scan. In the 3D printed phantom MVCT scan, the average density of the soft tissue and bone was 1.01 ± 0.09 g/cc and 1.44 ± 0.12 g/cc, respectively. Conclusion: A patient specific phantom, constructed of heterogeneous tissue substitute materials was constructed by 3D printing. MVCT of the 3D printed phantom showed realistic tissue densities were recreated by the 3D printing materials. Funding provided by intra-department grant by University of Minnesota Department of Radiation Oncology.

60 APPLIED LIFE SCIENCES↗

SU-D-201-07: Exploring the Utility of 4D FDG-PET/CT Scans in Design of Radiation Therapy Planning Compared with 3D PET/CT: A Prospective Study

Purpose: A method using four-dimensional(4D) PET/CT in design of radiation treatment planning was proposed and the target volume and radiation dose distribution changes relative to standard three-dimensional (3D) PET/CT were examined. Methods: A target deformable registration method was used by which the whole patient’s respiration process was considered and the effect of respiration motion was minimized when designing radiotherapy planning. The gross tumor volume of a non-small-cell lung cancer was contoured on the 4D FDG-PET/CT and 3D PET/CT scans by use of two different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; another technique using a constant threshold of standardized uptake value (SUV) greater than 2.5. The target volume and radiotherapy dose distribution between VOL3D and VOL4D were analyzed. Results: For all phases, the average automatic and manually GTV volume was 18.61 cm3 (range, 16.39–22.03 cm3) and 31.29 cm3 (range, 30.11–35.55 cm3), respectively. The automatic and manually volume of merged IGTV were 27.82 cm3 and 49.37 cm3, respectively. For the manual contour, compared to 3D plan the mean dose for the left, right, and total lung of 4D plan have an average decrease 21.55%, 15.17% and 15.86%, respectively. The maximum dose of spinal cord has an average decrease 2.35%. For the automatic contour, the mean dose for the left, right, and total lung have an average decrease 23.48%, 16.84% and 17.44%, respectively. The maximum dose of spinal cord has an average decrease 1.68%. Conclusion: In comparison to 3D PET/CT, 4D PET/CT may better define the extent of moving tumors and reduce the contouring tumor volume thereby optimize radiation treatment planning for lung tumors.

60 APPLIED LIFE SCIENCES↗

Three-dimensional liver motion tracking using real-time two-dimensional MRI

Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of shortwave spectra in fully 3D environment: synergy between scanning radars and spectral radiation measurements (final Report)

Overview of 3D atmospheric radiative transfer in cloudy atmosphere for Reports on Progress in Physics. We surveyed the 3D atmospheric radiative transfer literature over the past 50 years and identify three concurrent and intertwining themes: first, how to assess the damage (bias) caused by 3D effects in the operational 1D radiative transfer models? Second, how to mitigate this damage? Third, can we exploit 3D radiative transfer phenomena to invent new observation methods and technologies? Two equally important application areas for atmospheric radiative transfer in general, and 3D in particular, were identified: broadband radiative energy budget estimation and wavelength-specific optical remote sensing signal modeling. As illustrations, both satellite and ARM observations were highly used.

54 ENVIRONMENTAL SCIENCES↗

Angle resolved x-ray photoelectron spectroscopy (ARXPS) analysis of lanthanum oxide for micro-flexography printing

Micro-flexography printing was developed in patterning technique from micron to nano scale range to be used for graphic, electronic and bio-medical device on variable substrates. In this work, lanthanum oxide (La{sub 2}O{sub 3}) has been used as a rare earth metal candidate as depositing agent. This metal deposit was embedded on Carbon (C) and Silica (Si) wafer substrate using Magnetron Sputtering technique. The choose of Lanthanum as a target is due to its wide application in producing electronic devices such as thin film battery and printed circuit board. The La{sub 2}O{sub 3} deposited on the surface of Si wafer substrate was then analyzed using Angle Resolve X-Ray Photoelectron Spectroscopy (ARXPS). The position for each synthetic component in the narrow scan of Lanthanum (La) 3d and O 1s are referred to the electron binding energy (eV). The La 3d narrow scan revealed that the oxide species of this particular metal is mainly contributed by La{sub 2}O{sub 3} and La(OH){sub 3}. The information of oxygen species, O{sup 2-} component from O 1s narrow scan indicated that there are four types of species which are contributed from the bulk (O{sup 2−}), two chemisorb component (La{sub 2}O{sub 3}) and La(OH){sub 3} and physisorp component (OH). Here, it is proposed that from the adhesive and surface chemical properties of La, it is suitable as an alternative medium for micro-flexography printing technique in printing multiple fine solid lines at nano scale. Hence, this paper will describe the capability of this particular metal as rare earth metal for use in of micro-flexography printing practice. The review of other parameters contributing to print fine lines will also be described later.

36 MATERIALS SCIENCE↗

SU-F-T-215: An Investigation Of Multi-Scanner CT Hounsfield Unit Calibration for Pencil Beam Scanning Proton Therapy Using 3D Gamma Analysis

Purpose: We compare and investigate the dosimetric impacts on pencil beam scanning (PBS) proton treatment plans generated with CT calibration curves from four different CT scanners and one averaged ‘global’ CT calibration curve. Methods: The four CT scanners are located at three different hospital locations within the same health system. CT density calibration curves were collected from these scanners using the same CT calibration phantom and acquisition parameters. Mass density to HU value tables were then commissioned in a commercial treatment planning system. Five disease sites were chosen for dosimetric comparisons at brain, lung, head and neck, adrenal, and prostate. Three types of PBS plans were generated at each treatment site using SFUD, IMPT, and robustness optimized IMPT techniques. 3D dose differences were investigated using 3D Gamma analysis. Results: The CT calibration curves for all four scanners display very similar shapes. Large HU differences were observed at both the high HU and low HU regions of the curves. Large dose differences were generally observed at the distal edges of the beams and they are beam angle dependent. Out of the five treatment sites, lung plans exhibits the most overall range uncertainties and prostate plans have the greatest dose discrepancy. There are no significant differences between the SFUD, IMPT, and the RO-IMPT methods. 3D gamma analysis with 3%, 3 mm criteria showed all plans with greater than 95% passing rate. Two of the scanners with close HU values have negligible dose difference except for lung. Conclusion: Our study shows that there are more than 5% dosimetric differences between different CT calibration curves. PBS treatment plans generated with SFUD, IMPT, and the robustness optimized IMPT has similar sensitivity to the CT density uncertainty. More patient data and tighter gamma criteria based on structure location and size will be used for further investigation.

60 APPLIED LIFE SCIENCES↗