Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

An electroviscous damper

A new type of vibration damper for rotor systems was developed and tested. The damper contains electroviscous fluid which solidifies and provides Coulomb damping when an electric voltage is imposed across the fluid. The damping capacity is controlled by the voltage. The damper was incorporated in a flexible rotor system and found to be able to damp out high levels of unbalanced excitation. Other proven advantages include controllability, simplicity, and no requirement for oil supply. Still unconfirmed are the capabilities to eliminate critical speeds and to suppress rotor instabilities.

Nikolajsen, Jorgen L.↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Impedance Modeling and Stability Analysis for the PLL-less and Voltage Sensor-less Grid-tied Converters

The newly developed control methodology, which omits the phase-locked loop (PLL) and voltage sensor, has garnered considerable attention for its rapid dynamic response and reduced hardware expenses. Nonetheless, its stability concerns have not yet been thoroughly scrutinized. In this paper, the impedance modeling of the PLL-less and voltage sensorless control strategy has been established. The impedance model has been contrasted with the traditional PLL-based control scheme. Our findings demonstrate that the PLL-less and voltage sensorless control approach lacks the negative resistance behavior that is frequently observed in the traditional scheme, which results in unstable operations. Furthermore, the role of virtual resistance has been examined. To substantiate the aforementioned findings, simulation results are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of fault related voltage swell on distribution feeders using DER-based advanced inverter controls

Unbalanced faults in distribution feeders can impact voltages on the non-faulted phases. This paper models a real-life feeder with a high penetration level of solar photovoltaic (PV) units in detail including the secondary circuits, and shows a large voltage swell in one of the non-faulted phases of the feeder during a single line to ground fault. The voltages seen during this swell are more than 1.2 p.u., which can have detrimental impacts on the connected equipment and can also lead to loss of connected generation. The reason for this voltage swell is found to be the equivalent impedance at the fault location resulting from the ratio of zero and positive sequence cable impedances. It is seen that the connected solar PV units with appropriate control are able to reduce the severity of the voltage swell, especially for higher penetration levels of solar PV considered, but not entirely eliminate it.

14 SOLAR ENERGY↗

Harmonic control using matrix converter of unbalanced input voltage supplied from solar power system

Most of the renewable energy sources are not distributed directly to consumer. It gone through several section to get optimum output voltage and current with the almost zero distortion. Direct Matrix converters are well known of its better power quality and low power distortion to the reactive loads. Conversely, multilevel H bridge inverters are broadly used to attain a sinusoidal output voltage in solar photovoltaic application. Reactive power is subject to high importance for the operation of alternating current (AC) power systems. Moreover there is always a challenge to obtain the balance current control from an unbalanced supply voltage with minimum harmonic distortion for reactive load application from solar power system. The main objective of the proposed system is to maximize the power usage by maintaining the current and power factor nearby unity. There are many different optimization techniques are used so far in matrix converter, a novel method of optimization BAT algorithm is proposed for the power quality to get the best result. This work mainly deals with the compensation of reactive power used in Solar Photovoltaic Power System. Bidirectional energy flow is possible with matrix converter for battery charging. Simulation results are presented to confirm the appropriate operation of the system under different of operating conditions. Also, in the proposed method the percentage of the higher order harmonics can reduced less than 9% of matrix converter for solar photovoltaic application.

14 SOLAR ENERGY↗

Switching-cycle-based Startup for Grid-connected Inverters

Conventional inverter startups, or grid synchronization, are hindered by slow dynamics and inrush current issues, which impede the integration of more renewable energy resources into the power grid. This paper overcomes the barriers by introducing a novel switching cycle-based startup approach for grid-connected inverters, eliminating the need for voltage sensors and phase-locked loops (PLLs). The proposed method surpasses the bandwidth constraints of traditional PLL-based techniques and achieves grid synchronization in just two switching cycles. Relying solely on sensed three-phase currents, synchronization is accomplished without inrush currents or the need for additional hardware or increased software complexity, resulting in a faster inverter startup. The paper also presents a sensitivity analysis to discuss the impact of critical parameters on the method's accuracy. As a result, the effectiveness of the proposed technique is demonstrated through simulation and experimental results.

14 SOLAR ENERGY↗

Improving Distribution System Operations Using Fleet Control of Electrolyzers

The proliferation of electrolyzers presents an opportunity for grid operators. Fast response times and the use of hydrogen as storage can be leveraged in a symbiotic way to support increasing penetration levels of photovoltaics (PV) in the distribution grid. This work presents the grid integration of an electrolyzer fleet and its control applications to minimize the impact of increasing solar PV penetration in the distribution network. The study involves a feeder model of a real utility circuit from a utility partner with an operational model of a fleet of electrolyzers. The operational improvements are quantified with performance metrics. The metrics show that the fleet control application of the electrolyzers can aid in reducing overvoltages, voltage fluctuations, and control device operations induced by intermittent solar generation. The locational dependence of electrolyzers are also discussed in terms of performance metrics.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Control and Service Life Extension of Accelerator's Anode Voltage Regulator

Accelerator's beam quality is highly affected by the anode voltage's stability. The accelerator examined in this study is an ion implantation accelerator which anode voltage is regulated by an electromechanical system shown in Fig 1. The system works by stepping down the input grid voltage to generate a high anode voltage of up to 2.5 kV through a motor generator. It was desired that the system be able to correct for disturbances and instabilities in the input voltage swiftly while minimizing overshoots and steady state errors. Moreover, it should maintain such capability satisfactorily despite of degradations. It was predicted that this adaptive capability would be limited to a certain extent where if degradations become too severe, system's performance would deteriorate considerably such that maintenance actions or component replacements are required. The mechanism to control anode voltage, estimate and extend the system's Remaining Useful Life (RUL) in an integrated manner is explored in this paper. (authors)

43 PARTICLE ACCELERATORS↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A MAGNETIC CORE VOLTAGE-TO-FREQUENCY CONVERTER

Controlling the frequency of a square-loop magnetic core oscillator using a dc voltage to give a voltage-to-frequency conversion for use in pulse frequency modulated telemetry systems

PFM TELEMETRY↗

Power Hardware-in-the-Loop Evaluation of PV Inverter Grid Support on Hawaiian Electric Feeders

As more grid-connected photovoltaic (PV) inverters become compliant with evolving interconnections requirements, there is increased interest from utilities in understanding how to best deploy advanced grid-support functions (GSF) in the field. One efficient and cost-effective method to examine such deployment options is to leverage power hardware-in-the-loop (PHIL) testing methods, which combine the fidelity of hardware tests with the flexibility of computer simulation. This paper summarizes a study wherein two Hawaiian Electric feeder models were converted to real-time models using an OPAL-RT real-time digital testing platform, and integrated with models of GSF capable PV inverters based on characterization test data. The integrated model was subsequently used in PHIL testing to evaluate the effects of different fixed power factor and volt-watt control settings on voltage regulation of the selected feeders using physical inverters. Selected results are presented in this paper, and complete results of this study were provided as inputs for field deployment and technical interconnection requirements for grid-connected PV inverters on the Hawaiian Islands.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control of excitons in multi-layer van der Waals heterostructures

We report an experimental study of excitons in a double quantum well van der Waals heterostructure made of atomically thin layers of MoS{sub 2} and hexagonal boron nitride. The emission of neutral and charged excitons is controlled by gate voltage, temperature, and both the helicity and the power of optical excitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A New Linearization Method of Unbalanced Electrical Distribution Networks

Abstract--- With increasing penetration of distributed generation in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. As DN control and operation strategies are mostly based on the linearized sensitivity coefficients between controlled variables (e.g., node voltages, line currents, power loss) and control variables (e.g., power injections, transformer tap positions), efficient and precise calculation of these sensitivity coefficients, i.e. linearization of DN, is of fundamental importance. In this paper, the derivation of the node voltages and power loss as functions of the nodal power injections and transformers' tap-changers positions is presented, and then solved by a Gauss-Seidel method. Compared to other approaches presented in the literature, the proposed method takes into account different load characteristics (e.g., constant PQ, constant impedance, constant current and any combination of above) of a generic multi-phase unbalanced DN and improves the accuracy of linearization. Numerical simulations on both IEEE 13 and 34 nodes test feeders show the efficiency and accuracy of the proposed method.

linearization↗