Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

DSCOVR/EPIC-derived global hourly and daily downward shortwave and photosynthetically active radiation data at 0.1° × 0.1° resolution

Downward shortwave radiation (SW) and photosynthetically active radiation (PAR) play crucial roles in Earth system dynamics. Spaceborne remote sensing techniques provide a unique means for mapping accurate spatiotemporally continuous SW–PAR, globally. However, any individual polar-orbiting or geostationary satellite cannot satisfy the desired high temporal resolution (sub-daily) and global coverage simultaneously, while integrating and fusing multisource data from complementary satellites/sensors is challenging because of co-registration, intercalibration, near real-time data delivery and the effects of discrepancies in orbital geometry. The Earth Polychromatic Imaging Camera (EPIC) on board the Deep Space Climate Observatory (DSCOVR), launched in February 2015, offers an unprecedented possibility to bridge the gap between high temporal resolution and global coverage and characterize the diurnal cycles of SW–PAR globally. In this study, we adopted a suite of well-validated data-driven machine-learning models to generate the first global land products of SW–PAR, from June 2015 to June 2019, based on DSCOVR/EPIC data. The derived products have high temporal resolution (hourly) and medium spatial resolution (0.1°×0.1°), and they include estimates of the direct and diffuse components of SW–PAR. We used independently widely distributed ground station data from the Baseline Surface Radiation Network (BSRN), the Surface Radiation Budget Network (SURFRAD), NOAA's Global Monitoring Division and the U.S. Department of Energy's Atmospheric System Research (ASR) program to evaluate the performance of our products, and we further analyzed and compared the spatiotemporal characteristics of the derived products with the benchmarking Clouds and the Earth's Radiant Energy System Synoptic (CERES) data. We found both the hourly and daily products to be consistent with ground-based observations (e.g., hourly and daily total SWs have low biases of -3.96 and -0.71 W m -2 and root-mean-square errors (RMSEs) of 103.50 and 35.40 W m -2 , respectively). The developed products capture the complex spatiotemporal patterns well and accurately track substantial diurnal, monthly, and seasonal variations in SW–PAR when compared to CERES data. They provide a reliable and valuable alternative for solar photovoltaic applications worldwide and can be used to improve our understanding of the diurnal and seasonal variabilities of the terrestrial water, carbon and energy fluxes at various spatial scales.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Converter Performance Considering Static and Dynamic Device Part-to-Part Variability

This paper presents a methodology to incorporate and analyze the impact of semiconductor device part-to-part variation on power converter performance. By integrating extensive static and dynamic device characterization data with an automated compact model generation process that reflects manufacturing variability, device models with inherent variability features are utilized in converter simulations for a comprehensive assessment of performance impacts. The traditional converter performance evaluation process typically yields fixed efficiency values, often dismissing the inherent part-to-part variability caused by the manufacturing process of semiconductor devices. To address this limitation, a large population of devices was characterized to capture variations in static parameters-such as transfer, output, and capacitance characteristics-as well as dynamic behaviors, including switching losses. This data-driven approach enables the development of individual compact models, which were then integrated into converter simulations to evaluate efficiency ranges rather than single point estimated values. The converter simulation results show that part-to-part component variation can lead to significant efficiency deviations, exceeding several percentage points in high-power conversion applications. By offering a more accurate representation of converter behavior under real-world manufacturing conditions, this methodology enables designers to anticipate performance variability, improving the robustness of power converter designs.

device characterization↗

Turbulence statistical analysis of the L-H transition and RMPs in KSTAR

Here, we investigate the turbulence statistics associated with low-to-high confinement (L-H) transitions and externally applied resonant magnetic perturbations (RMPs) in KSTAR. Time-series fluctuations of electron density n e , electron temperature T e , and the time derivative of the poloidal magnetic field dB θ /dt (Mirnov coils) are analysed using information-geometric measures (information rate Γ and information length $\mathcal{L}$ = ∫ Γ dt), together with kurtosis κ and variance σ 2 . In low-density upper single-null plasmas (n e ~ 1.2 x 10 19 m -3 ), a ~80 kHz magnetic mode coupling n e , T e , dB θ /dt and emerges prior to the L-H transition and persists into the edge-localised modes H-mode. Edge-localised RMPs (ERMPs) suppress this coherent mode but enhance intermittency, producing frequent bursts that abruptly reshape the time-dependent probability density functions (PDFs) and generate large spikes in Γ (with smaller changes in κ), signalling ERMP-driven departures from quasi-stationarity. The impact of ERMPs on background fluctuation levels depends on density, radial location, and the fluctuating variable itself ($\tilde{n}$, $\tilde{T}$, $\dot{B}$ θ ), whereas $\mathcal{L}$ provides a robust, regime-agnostic measure of cumulative statistical reorganisation and spatial decorrelation. In particular, at low density we observe weaker coupling between $\tilde{n}$ and $\tilde{T}$, along with a tendency toward decreased radial correlation-most clearly for $\tilde{T}$-under ERMPs. Overall, information geometry cleanly captures intermittent events, quantifies non-equilibrium PDF evolution, and offers a compact, cross-diagnostic metric for assessing resonant magnetic perturbation effects on edge transport and correlation across densities, radial locations, and confinement states.

Kim, Eun-jin [Coventry Univ. (United Kingdom); Seo↗

Measurement of Deformation Heterogeneity During Shale Swelling Using Digital Image Correlation

Abstract Rock-fluid interactions in shale formations are one of the main sources of wellbore instability issues and inadequate stimulation performance. For better planning of fracturing operations and optimizing production from these reservoirs, it is important to understand the mechanisms behind these interactions. These issues are especially prevalent in clay-rich shales, such as Tuscaloosa Marine Shale, which is the subject of this study. Conventional techniques to quantify these shale-fluid interactions comprise of measuring swelling in powdered rock grains or measurement of deformation in the whole pieces of the core using a linear variable differential transformer and strain gages. However, the contribution from individual laminae to overall deformation cannot be evaluated using these methods. In this study, we developed an experimental setup to evaluate the spatial deformation in shale during interaction with water using digital image correlation (DIC). Deformation of two shale samples, with 34 wt% to 51 wt% clay content, was studied. White paint was used to generate a random speckle pattern on the specimen and then immersed in deionized water. The deformation process was captured using a digital camera and images were analyzed using DIC to quantify the deformation. The implementation of the DIC technique enables the visualization and quantification of spatial deformation in the specimen during interacting with water. The results show the localization of large strains in select laminations. The results provide a better understanding of shale deformation when interacting with water in comparison to traditional measurements that can provide only an average strain value.

Energy & Fuels↗

RAVIS: Resource Forecast and Ramp Visualization for Situational Awareness of Variable Renewable Generation: Preprint

The Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS) is an innovative, open-source tool for visualizing variable renewable resource forecasts and alerts for significant up- and down-ramps in renewable generation and the consequent system net load. The modular dashboard of RAVIS contains configurable panes for viewing probabilistic time-series forecasts, ramp event alerts on the look-ahead timeline, and spatially resolved resource sites, and forecasts. For comprehensive situational awareness, the tool can add additional data layers from simulation and independent system operator (ISO) market clearing data—including electric line utilization, nodal price, and available generation flexibility—in response to continuously updated renewable forecasts. This paper introduces the RAVIS technology suite employed to provide optimum visualization and flexible design characteristics. The paper also illustrates some use cases of the tool using site-specific solar power forecast data obtained from the IBM Watt-Sun forecasting platform for the California ISO and Midcontinent ISO footprints. The source code for RAVIS is public (https://github.com/ravis-nrel/ravis), and the intended users are forecasters, utility planners, ISO operators, and researchers.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Industry Partnerships & Their Role In Reducing Natural Gas Supply Chain Greenhouse Gas Emissions – Phase 2

This analysis is the product of collaboration between Our Nation’s Energy Future (ONE Future) and the United States (U.S.) Department of Energy (DOE) National Energy Technology Laboratory (NETL). This analysis is an update to Phase 1 of the collaboration between ONE Future and NETL. Phase 1 had three objectives: 1. Calculate a greenhouse gas (GHG) emission profile representative of ONE Future’s supply chain, including methane (CH 4 ) emission rates. 2. Compare ONE Future’s emission profile to the emission profile for the U.S. natural gas supply chain. 3. Evaluate specific emission reduction opportunities. Phase 2 has two key enhancements over Phase 1: 1. The reporting year of the data is updated from 2016 to 2017. 2. The emission profiles and the specific emission reduction opportunities are regionalized for the ONE Future supply chain. The ONE Future supply chain is based on data provided by ONE Future members for all their U.S. onshore assets. ONE Future’s data are mostly representative of their participation in the Greenhouse Gas Reporting Program (GHGRP) administered by the Environmental Protection Agency (EPA) and is supplemented by ONE Future facilities that are not required to report to GHGRP. The U.S. scenario is based on NETL’s life cycle analysis (LCA) of natural gas extraction and power generation, which also uses data from the GHGRP (but does not include non-GHGRP facilities). In addition to the data from these sources, NETL accounted for uncertainty due to data variability, data limitations, and variability in liquids unloading frequency and event duration. This report is a re-issue of the 2020 study (published on July 28, 2020). It revises the device count in the mitigation strategy “pipeline pump-down before maintenance” in the Marginal Abatement Cost (MAC) Analysis section of the report (Section 7). Please see the addendum for more details on this revision and resultant changes. This revision does not change most of our conclusions and recommendations. It only changes the total methane reduced from all the mitigation opportunities (low cost and high cost) from 6.5 Bcf CH 4 /yr to 4.8 Bcf CH 4 /yr.

03 NATURAL GAS↗

Representing surface heterogeneity in land–atmosphere coupling in E3SMv1 single-column model over ARM SGP during summertime

Abstract. The Earth's land surface features spatial and temporal heterogeneity over a wide range of scales below those resolved by current Earth system models (ESMs). State-of-the-art land and atmosphere models employ parameterizations to represent their subgrid heterogeneity, but the land–atmosphere coupling in ESMs typically operates on the grid scale. Communicating the information on the land surface heterogeneity with the overlying atmospheric boundary layer (ABL) remains a challenge in modeling land–atmosphere interactions. In order to account for the subgrid-scale heterogeneity in land–atmosphere coupling, we implement a new coupling scheme in the Energy Exascale Earth system model version 1 (E3SMv1) that uses adjusted surface variances and covariance of potential temperature and specific water content as the lower boundary condition for the atmosphere model. The new lower boundary condition accounts for both the variability of individual subgrid land surface patches and the inter-patch variability. The E3SMv1 single-column model (SCM) simulations over the Atmospheric Radiation Measurement (ARM) Southern Great Plain (SGP) site were performed to assess the impacts. We find that the new coupling parameterization increases the magnitude and diurnal cycle of the temperature variance and humidity variance in the lower ABL on non-precipitating days. The impacts are primarily attributed to subgrid inter-patch variability rather than the variability of individual patches. These effects extend vertically from the surface to several levels in the lower ABL on clear days. We also find that accounting for surface heterogeneity increases low cloud cover and liquid water path (LWP). These cloud changes are associated with the change in cloud regime indicated by the skewness of the probability density function (PDF) of the subgrid vertical velocity. In precipitating days, the inter-patch variability reduces significantly so that the impact of accounting for surface heterogeneity vanishes. These results highlight the importance of accounting for subgrid heterogeneity in land–atmosphere coupling in next-generation ESMs.

54 ENVIRONMENTAL SCIENCES↗

Bi-Level Linear Programming Model for Automatic Load Shedding: A Distributed Wide-Area Measurement System-based Solution

Load shedding is currently implemented as a two-step based approach. In the first step, manual load shedding is taken place, were system operators, using estimates, inform distribution utilities of predicted stressful conditions. Information provided include the potential use of energy reserves, as well as load shedding amount. In a second step, automatic load shedding is done. The latter is realized using protection relays. While considering frequency variation, pre-defined values of load to be shed and correspondent number of stages for such to be realized are transformed into relay settings. Under-frequency protection relays use only local measurements towards decision making, thus operate in a decentralized architecture. Decision making is done in milliseconds plus breaker time. While this approach has provided much system reliability, considering the new smart grid paradigm, where system dynamics are much faster due to increasing renewable resources penetration, in some operating conditions it will generate sub-optimal solutions, such as islanding. Phasor measurement units provide a source of information which can be useful for this problem. Centralized architecture-based solutions for automatic load shedding, as present in the state-of-the-art, require though total processing times which are not acceptable for real-life implementation. In this work, considering the above, a bi-level linear programming model is presented. The model is implemented considering a distributed architecture while leveraging phasor measurement units data. The upper-level model estimates the current system state. Results of this model are embedded in a lower-level model, which decision variables are the location and load value to be shed. Easy-to-implement model, built-on the classic weighted least squares solution, highlight potential aspects towards real-life applications.

Bretas, Arturo Suman↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Landscape-scale Characterization of Arctic Tundra Vegetation Composition, Structure, and Function with a Multi-sensor Unoccupied Aerial System: Supporting Data.

Airborne remote sensing data collected using the Brookhaven National Laboratory's (BNL) heavy-lift unoccupied aerial system (UAS) octocopter platform, the Osprey, operated by the Terrestrial Ecosystem Science and Technology (TEST) group (https://www.bnl.gov/testgroup). This package includes data from three flights flown over the NGEE-Arctic Council, Kougarok and Teller sites in July, 2018. The Osprey is a multi-sensor UAS platform that simultaneously measures very high spatial resolution optical red/green/blue (RGB) and thermal infrared (TIR) surface 'skin' temperature imagery, as well as surface reflectance at 1 nm intervals in the visible to near-infrared spectral range 350 - 1000 nm measured at regular intervals along each flight path. Derived image products include ortho-mosaiced RGB and TIR images, an RGB-based digital surface model (DSM) using the structure from motion (SfM) technique, digital terrain model (DTM), and a canopy height model (CHM). In addition, a VNIR surface reflectance file is provided for the trigger locations collected during each flight campaign. Ancillary aircraft data, flight mission parameters, and general flight conditions provided by the onboard flight and data collection computers are also included. Unprocessed and processed data products are included in this package (processing levels 0-3). Data and metadata are provided as text (*.txt, *.json, *.kml, *hdr, *.enp), tabular (*.dat, *.csv, *.waypoint, ENVI format (no extension)), point cloud (*.laz) and image (*.jpg, *.tif, *png) formats. This metadata document contains flight campaign, instrument and file metadata, along with a description of data processing levels, data products and file naming scheme.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy?s Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Ordovician-Cambrian Units: Hierarchical Evaluation of Geologic Carbon Storage Resource Estimates

The Indiana Geological and Water Survey (IGWS) led subtask 1.1 to assess the regional distribution and estimate the storage capacity of Ordovician-Cambrian stratigraphic units located within the partnership region. A comprehensive data set of wireline logs and petrophysical information was used to generate these interpretations. These data include core analysis for porosity and permeability, mercury injection capillary pressure (MICP), and existing well data including location and stratigraphic information. This report includes storage resource estimates (SREs) for three potential storage reservoirs(limestone and dolostone from the Upper Ordovician Trenton Limestone/Black River Group and equivalent units, the Middle Ordovician St. Peter Sandstone, and primary target reservoir rocks of the Lower Ordovician and Upper Cambrian Knox Supergroup and equivalent units) calculated using six methodologies: (1) a fixed value of porosity of 10 percent in all units evaluated; (2) a unique average porosity (per well) from wireline-derived porosity (neutron, sonic, and/or density porosity for each unit); (3) porosity values from core analysis; (4) a depth-dependent porosity model (Knox Supergroup only); (5) porosity based on a model based on petrophysical facies; and (6) SREs using National Energy Technology Laboratory’s CO2 Storage prospeCtive Resource Estimation Excel aNalysis (CO2-SCREEN beta V2). All methods used the same values for thickness for each unit. However, the areal extent of each assessment was limited by the data available for each method. Estimated volumes were calculated in 1-by-1 kilometer grid cells and summarized as county and total stratigraphic unit volumes. The resultant SREs mass are displayed using boxplots, which allow for comparing data statistics (mean values and variability) between methods. Differences observed in SRE results from the six methods are mainly attributable to differences in the data and conceptual models used to interpret or estimate porosity in each method. Based on this systematic variability between methods, it is inferred that methods 1, 4, and 6 are best used for regional-scale reconnaissance estimates of storage capacity while methods 2, 3, and 5 are more appropriate for local scales where more data is required. All estimates are data-density dependent and different methods require different amounts of data for reasonable assessments. ArcMap 10.5.1 software was used to portray SREs to help visualize spatial variance of estimates for each methodology, and more importantly, to highlight those areas having the greatest total storage potential estimates.

01 COAL, LIGNITE, AND PEAT↗

Impacts of Regional Coordination on Transmission Needs for Power System Resource Adequacy [Slides]

Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2023 Edition [Slides]

Improving battery technology and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes “co-located hybrids” that pair two or more resources (e.g., multiple types of generation and/or generation with storage) that are operated largely independently behind a single point of interconnection, and “full hybrids” that also feature coordinated operations of the co-located resources. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis. Key findings from the latest briefing include: -At the end of 2022, there were 374 hybrid plants (>1 MW) operating across the United States (+25% compared to the end of 2021), totaling nearly 41 GW of generating capacity (+15%) and 5.4 GW/15.2 GWh of energy storage (+69%/+88%). PV+storage plants are by far the most common, dominating in terms of plant number (213), storage capacity (4.0 GW/12.5 GWh), storage:generator capacity ratio (49%), and storage duration (3.1 hours). But there are nearly twenty other hybrid plant configurations as well, including several different fossil hybrid categories (each dominated by the fossil component) as well as wind+storage, wind+PV, wind+PV+storage, geothermal+PV, and others. -Last year was another strong year for PV+storage hybrids in particular: 59 of the 62 hybrids added in 2022 were PV+storage. As of the end of 2022, there was roughly as much storage capacity operating within PV+storage hybrid plants as in standalone storage plants (~4 GW each). In storage energy terms, however, PV+storage edged out standalone storage by ~2 GWh (12.5 GWh vs. 10.4 GWh, respectively). -Interconnection queue data show continued strong developer interest in hybridization. At the close of 2022, there were 51% more hybrid plants—representing 59% more generating capacity—in interconnection queues across the United States than there were at the end of 2021. Solar dominates these proposed plants as well: at the close of 2022, there were 457 GW of solar capacity proposed as a hybrid (representing ~48% of all solar capacity in the queues), most typically pairing PV with battery storage. At the same time, there were 24 GW of wind capacity proposed as a hybrid (representing ~8% of all wind capacity in the queues), again most-often pairing wind with storage. Meanwhile, more than half of all storage in the queues is estimated to be part of a hybrid plant. While many of the plants proposed in the queues will not ultimately reach commercial operations, the depth of interest in hybrid plants—especially PV+storage—is notable, particularly in certain regions. For example, in CAISO, 97% of all solar capacity and 45% of all wind capacity in the queues is proposed as a hybrid. -The report also surveys power purchase agreement (PPA) price data from a sample of operating and proposed PV+storage plants. Though PV+storage PPA prices have fallen over time, “levelized storage adders” have recently increased somewhat to ~$\$ $7000/MW-month, ~$\$ $60/MWh-stored (assuming one full cycle per day), or ~$\$ $15/MWh-PV. Some of the recent price increase could simply reflect a trend towards higher battery:PV capacity ratios over time, which increases costs, all else being equal. The well-publicized impact of inflationary and supply chain pressures on battery prices is no doubt a contributor as well.

25 ENERGY STORAGE↗

Operando X-Ray Tomography Imaging of Solid-State Electrolyte Response to Li Evolution under Realistic Operating Conditions

Solid-state Li-ion conductors are a next-generation battery technology that are particularly promising for electric vehicles, offering the capacitive benefits of Li metal anodes with nonflammable electrolytes. Microstructural evolution in these solid-state batteries, especially the Li anode, requires deeper understanding of the conditions under which certain undesired behaviors are more likely to occur. This study utilizes operando X-ray computed tomography to visualize the behavior of lithium in response to device operation, considering variables that are relevant to a realistic battery: stack pressure, microscale defects such as pores, and temperature. This work demonstrates that experimental and operational conditions, especially temperature, affect the fundamental driving forces of realistic solid electrolyte systems and provides visual insight into possible mechanisms of Li migration. In particular, the effect of these variables on Li propagation from the anode through pre-existing defects and Li nucleation within the imperfectly electron-insulating electrolyte is highlighted.

battery↗