Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Retinal Embolization During Carotid Angioplasty and Stenting: Periprocedural Data and Follow-Up

The purpose of this study was to prospectively evaluate the incidence of retinal emboli during carotid angioplasty and stenting (CAS) and to correlate emboli with clinical findings and transcranial Doppler (TCD)-detected cerebral embolic load. Between 2001 and 2005, 33 CAS procedures in 32 patients (23 [72%] male, 19 [58%] symptomatic, mean age 72.5 years [range 54.6 to 83.9]) scheduled for CAS were included in this study. Bilateral fundoscopy with retinal photography was performed by an experienced ophthalmologist immediately before, immediately after (fundoscopy only), and 1 day after the procedure and again at long-term follow-up (mean 37 months). Visual field testing was performed before CAS and again at long-term follow-up. TCD-detected cerebral emboli were stratified to five procedural phases: wiring, predilatation, stent placement, postdilatation, and cerebral protection device (CPD) use (if applicable). To establish correlation between TCD data and retinal embolization, Mann-Whitney test was used, and P < 0.05 was considered statistically significant. All procedures were performed successfully. In five of 33 procedures (15%), new retinal emboli were found. Two of the procedures with emboli had small retinal infarcts. Three of five were performed using CPDs versus seven of 28 that had no retinal emboli (P = not significant). Two of four patients (50%) with previous radiation therapy to the neck had new retinal emboli versus three of 29 patients (10%) who had no previous radiation therapy (P = 0.038). None of the other patient characteristics was associated with retinal embolization. In 30 (91%) of patients with an adequate acoustic temporal window for TCD monitoring, there was no statistically significant correlation between TCD data and the incidence of retinal emboli. No visual field defects were found. On long-term follow-up, all retinal emboli and retinal infarcts had resolved. Retinal embolization during CAS is not uncommon, and it occurs in both protected and unprotected procedures. Most retinal emboli are clinically silent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pain Analysis in Patients with Hepatocellular Carcinoma: Irreversible Electroporation versus Radiofrequency Ablation-Initial Observations

To retrospectively compare the postprocedure pain of hepatocellular carcinoma treated with irreversible electroporation (IRE) with radiofrequency ablation (RFA). This Health Insurance Portability and Accountability Act-compliant, institutional review board-approved study compared postprocedure pain in 21 patients (15 men, six women; mean age 61.5 years) who underwent IRE of 29 intrahepatic lesions (mean size 2.20 cm) in 28 IRE sessions with 22 patients (16 men, six women; mean age 60.2 years) who underwent RFA of 27 lesions (mean size 3.38 cm) in 25 RFA sessions. Pain was determined by patient-disclosed scores with an 11-point numerical rating scale and 24 h cumulative hydromorphone use from patient-controlled analgesia pump. Complications were noted. Statistical significance was evaluated by Fisher's exact test, the Chi-square test, and Student's t test. There was no significant difference in the cumulative hydromorphone dose (1.54 mg (IRE) vs. 1.24 mg (RFA); P = 0.52) and in the mean pain score (1.96 (IRE) vs. 2.25 (RFA); P = 0.70). In nine (32.14 %) of 28 IRE sessions and 11 (44.0 %) of 25 RFA sessions, patients reported no pain. Complications occurred in three (10.7 %) of 28 IRE treatments and included pneumothorax (n = 1), pleural effusion (n = 1), and bleeding in the form of hemothorax (n = 1); one (4 %) of 25 RFA treatments included burn. IRE is comparable to RFA in the amount of pain that patients experience and the amount of pain medication self-administered. Both modalities were well tolerated by patients. Prospective, randomized trials are necessary to further evaluate these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vascular Carbon/Carbon composites for concentrated solar power

Due to their exceptional mechanical and thermal properties under high temperature conditions, for the first time, a novel vascular (embedded channels) Carbon/Carbon (C/C) composite was developed for use as a modular concentrated solar power (CSP) gas receiver. The fabrication process involves the combination of the vaporization of sacrificial component (VaSC) technique with conventional methods to produce C/C composites with well preserved channels. Different heat treatments were evaluated together with X-ray diffraction (XRD) analysis to determine optimal fabrication conditions that maintains the material and channel’s integrity. Mechanical testing confirms that structural integrity is maintained, with statistical analyses indicating no compromise in flexural strength or modulus. Furthermore, this research introduces an innovative pathway for efficient CSP gas receivers, which can bridge the gap towards improved energy generation efficiency in next-gen CSP plants through higher operating temperatures with the use of C/C composites.

14 SOLAR ENERGY↗

Rare earth element behavior during groundwater–seawater mixing along the Kona Coast of Hawaii

Groundwater and seawater samples were collected from nearshore wells and offshore along the Kona Coast of the Big Island of Hawaii to investigate rare earth element (REE) behavior in local subterranean estuaries. Previously we saw that submarine groundwater discharge (SGD) is the predominant flux of terrestrial waters to the coastal ocean along the arid Kona Coast of Hawaii. Groundwater and seawater samples were filtered through 0.45 μm and 0.02 μm pore-size filters to evaluate the importance of colloidal and soluble (i.e., truly dissolved ionic species and/or low molecular weight [LMW] colloids) fractions of the REEs in the local subterranean estuaries. Mixing experiments using groundwater collected immediately down gradient from a wastewater treatment facility (WWTF) proximal to the Kaloko-Hanokohau National Historic Park, and more “pristine” groundwater from a well constructed in a lava tube at Kiholo Bay, were conducted with local seawater to study the effect of solution composition (i.e., pH, salinity) on the concentrations and fractionation behavior of the REEs as groundwater mixes with seawater in Kona Coast subterranean estuaries. The mixed waters were also filtered through 0.45 or 0.02 μm filters to ascertain the behavior of colloidal and soluble fractions of the REEs across the salinity gradient in each mixing experiment. Concentrations of the REEs were statistically identical (two-tailed Student t-test, 95% confidence) between the sequentially filtered sample aliquots, indicating that the REEs occur as dissolved ionic species and/or LMW colloids in Kona Coast groundwaters. The mixing experiments revealed that the REEs are released to solution from suspended particles or colloids when Kona Coast groundwater waters mix with local seawater. The order of release that accompanies increasing pH and salinity follows light REE (LREE) > middle REE (MREE) > heavy REE (HREE). Release of REEs in the mixing experiments is driven by decreases in the free metal ion activity in solution and the concomitant increase in the amount of each REE that occurs in solution as dicarbonato complexes [i.e., Ln(CO 3 ) 2 - ] as pH increases across the salinity gradient. Input-normalized REE patterns of Kona Coast groundwater and coastal seawater are nearly identical and relatively flat compared to North Pacific seawater, indicating that SGD is the chief source of these trace elements to the ocean along the Kona Coast. Additionally, REE concentrations of the coastal seawater are between 10 and 50 times higher than previously reported open-ocean seawater values from the North Pacific, further demonstrating the importance of SGD fluxes of REEs to these coastal waters. Altogether, these observations indicate that large-scale removal of REEs, which characterizes the behavior of REEs in the low salinity reaches of many surface estuaries, is not a feature of the subterranean estuary along the Kona Coast. A large positive gadolinium (Gd) anomaly characterizes groundwater from the vicinity of the WWTF. The positive Gd anomaly can be traced to the coastal ocean, providing further evidence of the impact of SGD on the coastal waters. Estimates of the SGD fluxes of the REEs to the coastal ocean along the Kona Coast (i.e., 1.3–2.6 mmol Nd day -1 ) are similar to recent estimates of SGD fluxes of REEs along Florida’s east coast and to Rhode Island Sound, all of which points to the importance of SGD as significant flux of REEs to the coastal ocean.

58 GEOSCIENCES↗

3'-deoxy-3'-[{sup 18}F]fluorothymidine PET Quantification of Bone Marrow Response to Radiation Dose

Purpose: The purpose of this study was to quantify the relationship of bone marrow response to radiation dose, using 3'-deoxy-3'-[{sup 18}F]fluorothymidine ([{sup 18}F]FLT)-labeled uptake quantified in positron-emission tomography (PET) scans. Methods and Materials: Pre- and post-Week 1 treatment [{sup 18}F]FLT PET images were registered to the CT images used to create the radiation treatment plan. Changes in [{sup 18}F]FLT uptake values were measured using profile data of standardized uptake values (SUVs) and doses along the vertebral bodies located at a field border where a range of radiation doses were present for 10 patients. Data from the profile measurements were grouped into 1 Gy dose bins from 1 to 9 Gy to compare SUV changes for all patients. Additionally, the maximum pretreatment, the post-Week 1 treatment, and the dose values located within the C6-T7 vertebrae that straddled the field edge were measured for all patients. Results: Both the profile and the individual vertebral data showed a strong correlation between SUV change and radiation dose. Relative differences in SUVs between bins >1 Gy and <7 Gy were statistically significant (p < 0.01, two-sample t test). The reduction in SUV was approximately linear until it reached a reduction threshold of 75%-80% in SUV for doses greater than 6 Gy/week for both the dose-binned data and the vertebral maximum SUVs. Conclusions: The change in SUV observed in head and neck cancer patients treated with chemoradiation shows the potential for using [{sup 18}F]FLT PET images for identifying active bone marrow and monitoring changes due to radiation dose. Additionally, the change in [{sup 18}F]FLT uptake observed in bone marrow for different weekly doses suggests potential dose thresholds for reducing bone marrow toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Heart and Coronary Artery Doses Associated With Intensity-Modulated Radiotherapy Versus Three-Dimensional Conformal Radiotherapy for Distal Esophageal Cancer

Purpose: To compare heart and coronary artery radiation exposure using intensity-modulated radiotherapy (IMRT) vs. four-field three-dimensional conformal radiotherapy (3D-CRT) treatment plans for patients with distal esophageal cancer undergoing chemoradiation. Methods and Materials: Nineteen patients with distal esophageal cancers treated with IMRT from March 2007 to May 2008 were identified. All patients were treated to 50.4 Gy with five-field IMRT plans. Theoretical 3D-CRT plans with four-field beam arrangements were generated. Dose-volume histograms of the planning target volume, heart, right coronary artery, left coronary artery, and other critical normal tissues were compared between the IMRT and 3D-CRT plans, and selected parameters were statistically evaluated using the Wilcoxon rank-sum test. Results: Intensity-modulated radiotherapy treatment planning showed significant reduction (p < 0.05) in heart dose over 3D-CRT as assessed by average mean dose (22.9 vs. 28.2 Gy) and V30 (24.8% vs. 61.0%). There was also significant sparing of the right coronary artery (average mean dose, 23.8 Gy vs. 35.5 Gy), whereas the left coronary artery showed no significant improvement (mean dose, 11.2 Gy vs. 9.2 Gy), p = 0.11. There was no significant difference in percentage of total lung volume receiving at least 10, 15, or 20 Gy or in the mean lung dose between the planning methods. There were also no significant differences observed for the kidneys, liver, stomach, or spinal cord. Intensity-modulated radiotherapy achieved a significant improvement in target conformity as measured by the conformality index (ratio of total volume receiving 95% of prescription dose to planning target volume receiving 95% of prescription dose), with the mean conformality index reduced from 1.56 to 1.30 using IMRT. Conclusions: Treatment of patients with distal esophageal cancer using IMRT significantly decreases the exposure of the heart and right coronary artery when compared with 3D-CRT. Long-term studies are necessary to determine how this will impact on development of coronary artery disease and other cardiac complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-Fluorodeoxyglucose Positron Emission Tomography Can Quantify and Predict Esophageal Injury During Radiation Therapy

Purpose: We sought to investigate the ability of mid-treatment {sup 18}F-fluorodeoxyglucose positron emission tomography (PET) studies to objectively and spatially quantify esophageal injury in vivo from radiation therapy for non-small cell lung cancer. Methods and Materials: This retrospective study was approved by the local institutional review board, with written informed consent obtained before enrollment. We normalized {sup 18}F-fluorodeoxyglucose PET uptake to each patient's low-irradiated region (<5 Gy) of the esophagus, as a radiation response measure. Spatially localized metrics of normalized uptake (normalized standard uptake value [nSUV]) were derived for 79 patients undergoing concurrent chemoradiation therapy for non-small cell lung cancer. We used nSUV metrics to classify esophagitis grade at the time of the PET study, as well as maximum severity by treatment completion, according to National Cancer Institute Common Terminology Criteria for Adverse Events, using multivariate least absolute shrinkage and selection operator (LASSO) logistic regression and repeated 3-fold cross validation (training, validation, and test folds). This 3-fold cross-validation LASSO model procedure was used to predict toxicity progression from 43 asymptomatic patients during the PET study. Dose-volume metrics were also tested in both the multivariate classification and the symptom progression prediction analyses. Classification performance was quantified with the area under the curve (AUC) from receiver operating characteristic analysis on the test set from the 3-fold analyses. Results: Statistical analysis showed increasing nSUV is related to esophagitis severity. Axial-averaged maximum nSUV for 1 esophageal slice and esophageal length with at least 40% of axial-averaged nSUV both had AUCs of 0.85 for classifying grade 2 or higher esophagitis at the time of the PET study and AUCs of 0.91 and 0.92, respectively, for maximum grade 2 or higher by treatment completion. Symptom progression was predicted with an AUC of 0.75. Dose metrics performed poorly at classifying esophagitis (AUC of 0.52, grade 2 or higher mid treatment) or predicting symptom progression (AUC of 0.67). Conclusions: Normalized uptake can objectively, locally, and noninvasively quantify esophagitis during radiation therapy and predict eventual symptoms from asymptomatic patients. Normalized uptake may provide patient-specific dose-response information not discernible from dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Incidental Radiation Dose to Uninvolved Mediastinal/Supraclavicular Lymph Nodes in Patients with Limited-Stage Small Cell Lung Cancer Treated Without Elective Nodal Irradiation

Classic teaching states that treatment of limited-stage small cell lung cancer (L-SCLC) requires large treatment fields covering the entire mediastinum. However, a trend in modern thoracic radiotherapy is toward more conformal fields, employing positron emission tomography/computed tomography (PET/CT) scans to determine the gross tumor volume (GTV). This analysis evaluates the dosimetric results when using selective nodal irradiation (SNI) to treat a patient with L-SCLC, quantitatively comparing the results to standard Intergroup treatment fields. Sixteen consecutive patients with L-SCLC and central mediastinal disease who also underwent pretherapy PET/CT scans were studied in this analysis. For each patient, we created SNI treatment volumes, based on the PET/CT-based criteria for malignancy. We also created 2 ENI plans, the first without heterogeneity corrections, as per the Intergroup 0096 study (ENI{sub off}) and the second with heterogeneity corrections while maintaining constant the number of MUs delivered between these latter 2 plans (ENI{sub on}). Nodal stations were contoured using published guidelines, then placed into 4 'bins' (treated nodes, 1 echelon away, >1 echelon away within the mediastinum, contralateral hilar/supraclavicular). These were aggregated across the patients in the study. Dose to these nodal bins and to tumor/normal structures were compared among these plans using pairwise t-tests. The ENI{sub on} plans demonstrated a statistically significant degradation in dose coverage compared with the ENI{sub off} plans. ENI and SNI both created a dose gradient to the lymph nodes across the mediastinum. Overall, the gradient was larger for the SNI plans, although the maximum dose to the '1 echelon away' nodes was not statistically different. Coverage of the GTV and planning target volume (PTV) were improved with SNI, while simultaneously reducing esophageal and spinal cord dose though at the expense of modestly reduced dose to anatomically distant lymph nodes within the mediastinum. The ENI{sub on} plans demonstrate that intergroup-style treatments, as actually delivered, had statistically reduced coverage to the mediastinum and tumor volumes than was reported. Furthermore, SNI leads to improved tumor coverage and reduced esophageal/spinal cord dose, which suggests the possibility of dose escalation using SNI.

61 RADIATION PROTECTION AND DOSIMETRY↗

The impact of intensity-modulated radiation therapy plan normalization in the postprostatectomy setting—does it matter?

The International Commission on Radiation Units & Measurements -83 recommends prescribing intensity-modulated radiation therapy (IMRT) in a dose-volume manner. Despite this, clinical variation still exists in how prostate IMRT plans are prescribed. This study aims to investigate the impact of different plan normalization methods for postprostatectomy IMRT. IMRT treatment plans were created retrospectively for 20 postprostatectomy patients. These were normalized such that the dose received by 98% (D98) of the planning target volume (PTV) was equal to 100% of the prescribed dose. All plans were individually optimized to achieve target coverage and organ at risk (OAR) dose constraints. Each patient's plan was then copied and normalized such that the mean dose (Dmean) received by the PTV was equal to 100% of the prescribed dose. The International Commission on Radiation Units & Measurements -83 recommended dosimetric end points were extracted for targets and Quantitative Analyses of Normal Tissue Effects in the Clinic or Radiation Therapy Oncology Group 0534 end points extracted for OARs. Statistical analysis using the Wilcoxon signed-rank test to measure the difference between data from plans normalized to D98 and Dmean was conducted. Extracted dosimetric end points of the targets and OARs were significantly higher in plans normalized to D98 than Dmean (p Normalization impacts on dosimetric end points of a plan. Hence, reporting the normalization method used is necessary to allow for meaningful interpretation of IMRT dosimetric studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distribution of binding energies of a water molecule in the water liquid-vapor interface

Distributions of binding energies of a water molecule in the water liquid-vapor interface are obtained on the basis of molecular simulation with the SPC/E model of water. These binding energies together with the observed interfacial density profile are used to test a minimally conditioned Gaussian quasi-chemical statistical thermodynamic theory. Binding energy distributions for water molecules in that interfacial region clearly exhibit a composite structure. A minimally conditioned Gaussian quasi-chemical model that is accurate for the free energy of bulk liquid water breaks down for water molecules in the liquid-vapor interfacial region. This breakdown is associated with the fact that this minimally conditioned Gaussian model would be inaccurate for the statistical thermodynamics of a dilute gas. Aggressive conditioning greatly improves the performance of that Gaussian quasi-chemical model. The analogy between the Gaussian quasi-chemical model and dielectric models of hydration free energies suggests that naive dielectric models without the conditioning features of quasi-chemical theory will be unreliable for these interfacial problems. Multi-Gaussian models that address the composite nature of the binding energy distributions observed in the interfacial region might provide a mechanism for correcting dielectric models for practical applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fundamental Physics with Cold Positronium

The use of positron plasmas to produce intense positron pulses has made it possible to create relatively large instantaneous positronium densities. This in turn provides an opportunity to perform improved precision spectroscopy measurements on positronium that will be limited by systematic rather than statistical effects which will improve present QED positronium tests by orders of magnitude. Further increases in the positronium density will lead to the production of a positronium Bose-Einstein condensate, further increasing the accuracy of such measurements and making it possible to study the phase diagram of a matter-antimatter condensate for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray digital industrial radiography (DIR) for local liquid velocity (V{sub LL}) measurement in trickle bed reactors (TBRs): Validation of the technique

Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V{sub LL}) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V{sub LL} within TBRs.

42 ENGINEERING↗

Enhancing the quality of radiographic images acquired with point-like gamma-ray sources through correction of the beam divergence and attenuation

Radiographic images acquired with point-like gamma-ray sources exhibit a desirable low penumbra effects specially when positioned far away from the set object-detector. Such an arrangement frequently is not affordable due to the limited flux provided by a distant source. A closer source, however, has two main drawbacks, namely the degradation of the spatial resolution - as actual sources are only approximately punctual - and the non-homogeneity of the beam hitting the detector, which creates a false attenuation map of the object being inspected. This non-homogeneity is caused by the beam divergence itself and by the different thicknesses traversed the beam even if the object were an homogeneous flat plate. In this work, radiographic images of objects with different geometries, such as flat plates and pipes have undergone a correction of beam divergence and attenuation addressing the experimental verification of the capability and soundness of an algorithm formerly developed to generate and process synthetic images. The impact of other parameters, including source-detector gap, attenuation coefficient, ratio defective-to-main hull thickness and counting statistics have been assessed for specifically tailored test-objects aiming at the evaluation of the ability of the proposed method to deal with different boundary conditions. All experiments have been carried out with an X-ray sensitive Imaging Plate and reactor-produced {sup 198}Au and {sup 165}Dy sources. The results have been compared with other technique showing a better capability to correct the attenuation map of inspected objects unveiling their inner structure otherwise concealed by the poor contrast caused by the beam divergence and attenuation, in particular for those regions far apart from the vertical of the source.

07 ISOTOPE AND RADIATION SOURCES↗

A NEW METHOD FOR CLASSIFYING FLARES OF UV Ceti TYPE STARS: DIFFERENCES BETWEEN SLOW AND FAST FLARES

In this study, a new method is presented to classify flares derived from the photoelectric photometry of UV Ceti type stars. This method is based on statistical analyses using an independent samples t-test. The data used in analyses were obtained from four flare stars observed between 2004 and 2007. The total number of flares obtained in the observations of AD Leo, EV Lac, EQ Peg, and V1054 Oph is 321 in the standard Johnson U band. As a result flares can be separated into two types, slow and fast, depending on the ratio of flare decay time to flare rise time. The ratio is below 3.5 for all slow flares, while it is above 3.5 for all fast flares. Also, according to the independent samples t-test, there is a difference of about 157 s between equivalent durations of slow and fast flares. In addition, there are significant differences between amplitudes and rise times of slow and fast flares.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EFFECT OF COUPLED DARK ENERGY ON THE ALIGNMENT BETWEEN DARK MATTER AND GALAXY DISTRIBUTIONS IN CLUSTERS

We investigate the effects of a coupled dark energy (cDE) scalar field on the alignment between satellites and matter distributions in galaxy clusters. Using high-resolution N-body simulations for {Lambda}CDM and cDE cosmological models, we compute the probability density distribution for the alignment angle between the satellite galaxies and underlying matter distributions, finding a difference between the two scenarios. With respect to {Lambda}CDM, in cDE cosmologies the satellite galaxies are less preferentially located along the major axis of the matter distribution, possibly reducing the tension with observational data. A physical explanation is that the coupling between dark matter and dark energy (DE) acts as an additional tidal force on the satellite galaxies, diminishing the alignments between their distribution and the matter one. Through a Wald test based on the generalized {chi}{sup 2} statistics, the null hypothesis that the two probability distributions come from the same parent population is rejected at the 99% confidence level. It is concluded that the galaxy-matter alignment in clusters may provide a unique probe of dark sector interactions as well as the nature of DE.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark black holes in the mass gap

Abstract In the standard picture of stellar evolution, pair-instability — the energy loss in stellar cores due to electron-positron pair production — is predicted to prevent the collapse of massive stars into black holes with mass in the range between approximately 50 and 130 solar masses — a range known as the “black hole mass gap”. LIGO and Virgo detection of black hole binary mergers containing one or both black holes with masses in thismass gapthus challenges the standard picture, possibly pointing to an unexpected merger history, unanticipated or poorly understood astrophysical mechanisms, or new physics. Here, we entertain the possibility that a “dark sector” exists, consisting of dark electrons, dark protons, and electromagnetic-like interactions, but no nuclear forces. Dark stars would inevitably form given such dark sector constituents, possibly collapsing into black holes with masses within the mass gap. We study in detail the cooling processes necessary for successful stellar collapse in the dark sector and show that for suitable choices of the particle masses, we indeed predict populating the mass gap with dark sector black holes. In particular, we numerically find that the heavier of the two dark sector massive particles cannot be lighter than, approximately, the visible sector proton for the resulting dark sector black holes to have masses within the mass gap. We discuss constraints on this scenario and how to test it with future, larger black hole merger statistics.

Astronomy & Astrophysics↗

Sigma: Strain-level inference of genomes from metagenomic analysis for biosurveillance

Motivation: Metagenomic sequencing of clinical samples provides a promising technique for direct pathogen detection and characterization in biosurveillance. Taxonomic analysis at the strain level can be used to resolve serotypes of a pathogen in biosurveillance. Sigma was developed for strain-level identification and quantification of pathogens using their reference genomes based on metagenomic analysis. Results: Sigma provides not only accurate strain-level inferences, but also three unique capabilities: (i) Sigma quantifies the statistical uncertainty of its inferences, which includes hypothesis testing of identified genomes and confidence interval estimation of their relative abundances; (ii) Sigma enables strain variant calling by assigning metagenomic reads to their most likely reference genomes; and (iii) Sigma supports parallel computing for fast analysis of large datasets. In conclusion, the algorithm performance was evaluated using simulated mock communities and fecal samples with spike-in pathogen strains. Availability and Implementation: Sigma was implemented in C++ with source codes and binaries freely available at http://sigma.omicsbio.org.

59 BASIC BIOLOGICAL SCIENCES↗