Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “task analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Self Assembling Mars Transfer Vehicles: The Preferred Concept of the Space Transfer Concepts and Analysis for Explorations Missions Study

Recently, one of the most comprehensive design studies of conceptual manned Mars vehicles, conducted since the Apollo era Mars mission studies of the 1960's, was completed. One of the tasks of the study involved the analysis of nuclear thermal propulsion spacecraft for Manned Mars exploration missions. This paper describes the specific effort aimed at vehicle configuration design. Over the course of the four year study, three configuration baselines were developed, each reflecting trade study cycle results of sequential phases of the study. Favorable attributes incorporated into the final concept, including a capability for on-orbit self-assembly and ease of launch vehicle packability, represent design solutions to configuration deficiencies plaguing nuclear propulsion Mars spacecraft design since the vehicle archetype originated in the 1950's. This paper contains a narrative summary of significant milestones in the effort, describes the evolution to the preferred configuration, and set forth the benefits derived from its utilization.

Donahue, Benjamin↗

Using machine learning techniques to automate sky survey catalog generation

We describe the application of machine classification techniques to the development of an automated tool for the reduction of a large scientific data set. The 2nd Palomar Observatory Sky Survey provides comprehensive photographic coverage of the northern celestial hemisphere. The photographic plates are being digitized into images containing on the order of 10(exp 7) galaxies and 10(exp 8) stars. Since the size of this data set precludes manual analysis and classification of objects, our approach is to develop a software system which integrates independently developed techniques for image processing and data classification. Image processing routines are applied to identify and measure features of sky objects. Selected features are used to determine the classification of each object. GID3* and O-BTree, two inductive learning techniques, are used to automatically learn classification decision trees from examples. We describe the techniques used, the details of our specific application, and the initial encouraging results which indicate that our approach is well-suited to the problem. The benefits of the approach are increased data reduction throughput, consistency of classification, and the automated derivation of classification rules that will form an objective, examinable basis for classifying sky objects. Furthermore, astronomers will be freed from the tedium of an intensely visual task to pursue more challenging analysis and interpretation problems given automatically cataloged data.

Fayyad, Usama M.↗

Requirements-Driven Log Analysis Extended Abstract

Imagine that you are tasked to help a project improve their testing effort. In a realistic scenario it will quickly become clear, that having an impact is diffcult. First of all, it will likely be a challenge to suggest an alternative approach which is significantly more automated and/or more effective than current practice. The reality is that an average software system has a complex input/output behavior. An automated testing approach will have to auto-generate test cases, each being a pair (i; o) consisting of a test input i and an oracle o. The test input i has to be somewhat meaningful, and the oracle o can be very complicated to compute. Second, even in case where some testing technology has been developed that might improve current practice, it is then likely difficult to completely change the current behavior of the testing team unless the technique is obviously superior and does everything already done by existing technology. So is there an easier way to incorporate formal methods-based approaches than the full edged test revolution? Fortunately the answer is affirmative. A relatively simple approach is to benefit from possibly already existing logging infrastructure, which after all is part of most systems put in production. A log is a sequence of events, generated by special log recording statements, most often manually inserted in the code by the programmers. An event can be considered as a data record: a mapping from field names to values. We can analyze such a log using formal methods, for example checking it against a formal specification. This separates running the system for analyzing its behavior. It is not meant as an alternative to testing since it does not address the important in- put generation problem. However, it offers a solution which testing teams might accept since it has low impact on the existing process. A single person might be assigned to perform such log analysis, compared to the entire testing team changing behavior.

log analysis↗

Domain Adaptation for Measurements of Strong Gravitational Lenses

Upcoming surveys are predicted to discover galaxy-scale strong lenses on the order of 10\textsuperscript{5}, making deep learning methods necessary in lensing data analysis. Currently, there is insufficient real lensing data to train deep learning algorithms, but the alternative of training only on simulated data results in poor performance on real data. Domain Adaptation may be able to bridge the gap between simulated and real datasets. We utilize domain adaptation for the estimation of Einstein radius ($\Theta_E$) in simulated galaxy-scale gravitational lensing images with different levels of observational realism. We evaluate two domain adaptation techniques - Domain Adversarial Neural Networks (DANN) and Maximum Mean Discrepancy (MMD). We train on a source domain of simulated lenses and apply it to a target domain of lenses simulated to emulate noise conditions in the Dark Energy Survey (DES). We show that both domain adaptation techniques can significantly improve the model performance on the more complex target domain dataset. This work is the first application of domain adaptation for a regression task in strong lensing imaging analysis. Our results show the potential of using domain adaptation to perform analysis of future survey data with a deep neural network trained on simulated data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Domain Adaptation for Measurements of Strong Gravitational Lenses

Upcoming surveys are predicted to discover galaxy-scale strong lenses on the order of $10^5$, making deep learning methods necessary in lensing data analysis. Currently, there is insufficient real lensing data to train deep learning algorithms, but the alternative of training only on simulated data results in poor performance on real data. Domain Adaptation may be able to bridge the gap between simulated and real datasets. We utilize domain adaptation for the estimation of Einstein radius ($\Theta_E$) in simulated galaxy-scale gravitational lensing images with different levels of observational realism. We evaluate two domain adaptation techniques - Domain Adversarial Neural Networks (DANN) and Maximum Mean Discrepancy (MMD). We train on a source domain of simulated lenses and apply it to a target domain of lenses simulated to emulate noise conditions in the Dark Energy Survey (DES). We show that both domain adaptation techniques can significantly improve the model performance on the more complex target domain dataset. This work is the first application of domain adaptation for a regression task in strong lensing imaging analysis. Our results show the potential of using domain adaptation to perform analysis of future survey data with a deep neural network trained on simulated data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative analysis of defects in silicon. Silicon sheet growth development for the large are silicon sheet task of the low-cost solar array project

One hundred and seventy four silicon sheet samples were analyzed for twin boundary density, dislocation pit density, and grain boundary length. Procedures were developed for the quantitative analysis of the twin boundary and dislocation pit densities using a QTM-720 Quantitative Image Analyzing system. The QTM-720 system was upgraded with the addition of a PDP 11/03 mini-computer with dual floppy disc drive, a digital equipment writer high speed printer, and a field-image feature interface module. Three versions of a computer program that controls the data acquisition and analysis on the QTM-720 were written. Procedures for the chemical polishing and etching were also developed.

Natesh, R.↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AW Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AW tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service-life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 23-25, 2016, on a slipstream from the AW exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automating sky object classification in astronomical survey images

We describe the application of machine classification techniques to the development of an automated tool for the reduction of a large scientific data set. The 2nd Palomer Observatory Sky Survey is nearly completed. This survey provides comprehensive coverage of the northern celestial hemisphere in the form of photographic plates. The plates are being transformed into digitized images whose quality will probably not be surpassed in the next ten to twenty years. The images are expected to contain on the order of 10(exp 7) galaxies and 10(exp 8) stars. Astronomers wish to determine which of these sky objects belong to various classes of galaxies and stars. The size of this data set precludes manual analysis. Our approach is to develop a software system which integrates the functions of independently developed techniques for image processing and data classification. Digitized sky images are passed through image processing routines to identify sky objects and to extract a set of features for each object. These routines are used to help select a useful set of attributes for classifying sky objects. Then GID3* and O-BTree, two inductive learning techniques, learn classification decision trees from examples. These classifiers will be used to process the rest of the data. This paper gives an overview of the machine learning techniques used, describes the details of our specific application, and reports the initial encouraging results. The results indicate that our approach is well-suited to the problem. The primary benefits of the approach are increased data reduction throughput and consistency of classification. The classification rules which are the product of the inductive learning techniques will form an object, examinable basis for classifying sky objects. A final, not to be underestimated benefit is that astronomers will be freed from the tedium of an intensely visual task to pursue more challenging analysis and interpretation problems based on automatically cataloged data.

Fayyad, Usama M.↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Saltstone SDU6 Modeling Study

A new disposal unit, designated as Saltstone Disposal Unit 6 (SDU6), is being designed for support of site accelerated closure goals and salt waste projections identified in the new Liquid Waste System Plan. The unit is a cylindrical disposal cell of 375 ft in diameter and 43 ft in height, and it has a minimum 30 million gallons of capacity. SRNL was requested to evaluate the impact of an increased grout placement height on the flow patterns radially spread on the floor and to determine whether grout quality is impacted by the height. The primary goals of the work are to develop the baseline Computational Fluid Dynamics (CFD) model and to perform the evaluations for the flow patterns of grout material in SDU6 as a function of elevation of grout discharge port and grout rheology. Two transient grout models have been developed by taking a three-dimensional multiphase CFD approach to estimate the domain size of the grout materials radially spread on the facility floor and to perform the sensitivity analysis with respect to the baseline design and operating conditions such as elevation height of the discharge port and fresh grout properties. For the CFD modeling calculations, air-grout Volume of Fluid (VOF) method combined with Bingham plastic and time-dependent grout models were used for examining the impact of fluid spread performance for the initial baseline configurations and to evaluate the impact of grout pouring height on grout quality. The grout quality was estimated in terms of the air volume fraction for the grout layer formed on the SDU6 floor, resulting in the change of grout density. The study results should be considered as preliminary scoping analyses since benchmarking analysis is not included in this task scope. Transient analyses with the Bingham plastic model were performed with the FLUENT TM code on the high performance parallel computing platform in SRNL. The analysis coupled with a transient grout aging model was performed by using ANSYS-CFX code in the parallel computing platform in Mercer University. Recommended operational guidance was developed assuming that local shear rates and flow patterns related to radial spread along the SDU floor can be used as a measure of grout performance and spatial dispersion affected by the grout height and viscosity. The main conclusions drawn from the grout modeling and calculations are as follows: • The 5 ft height baseline results show that when the 150 gpm grout flow with a 5 Pa yield stress and a 60 cp viscosity is poured down through a 3 inch discharge port, the grout is spread radially up to about 64 ft distance from the pouring center after 2 hours’ pouring time. The air volume fraction of the grout layer is about 29% at 5 minutes’ transient time, and it is reduced by about 9% in 2 hours’ pouring time, resulting in the grout density consisting of about 80% grout and 20% air volume fractions. • The sensitivity results show that when the discharge port is located at a higher position, a larger amount of air is trapped inside the layer formed below the discharge port at the early transient time of less than 30 minutes because of the higher impinging momentum of the grout flow on the floor, resulting in the formation of less smooth layer. • The results clearly indicate that the radial spread for the 43 ft discharge port is about 10% faster than that of the 5 ft discharge port for the early transient period of 5 minutes. However, for the pouring time longer than half an hour, the discharge port height does not affect the radial distance spread on the disposal floor. • When grout quality is related to grout volume fraction, the grout volume fraction for the 43 ft discharge port has lower volume fraction than the 5 ft discharge port for the transient period of the first 5 minutes. However, for the pouring time longer than half an hour, the discharge port height does not affect the grout volume fraction for the layer accumulated on the disposal floor. • A modified Bingham plastic model coupled with time-dependent viscosity behavior was developed for conducting the initial scoping calculations to assess the impact of fluid residence time on radial spreading and basic flow patterns. • The results for the transient viscosity model show that when grout material becomes more viscous, the thickness of the grout layer accumulated on the floor becomes higher, but the radial distance spread on the horizontal floor becomes smaller. The early transient results for the grout density with about 32% air volume fractions are in reasonable agreement with those of the idealized Bingham plastic model. • It is recommended that the current models developed here be benchmarked against the experimental results for critical applications of the modeling results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗