Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small scale processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Structural Similitude and Scaling Laws for Plates and Shells: A Review

This paper deals with the development and use of scaled-down models in order to predict the structural behavior of large prototypes. The concept is fully described and examples are presented which demonstrate its applicability to beam-plates, plates and cylindrical shells of laminated construction. The concept is based on the use of field equations, which govern the response behavior of both the small model as well as the large prototype. The conditions under which the experimental data of a small model can be used to predict the behavior of a large prototype are called scaling laws or similarity conditions and the term that best describes the process is structural similitude. Moreover, since the term scaling is used to describe the effect of size on strength characteristics of materials, a discussion is included which should clarify the difference between "scaling law" and "size effect". Finally, a historical review of all published work in the broad area of structural similitude is presented for completeness.

Simitses, G. J.↗

Microphone Corrections for Accurate In-Flow Acoustic Measurements at High Frequency

Acoustic analysis of aircraft components through small-scale experiments in wind tunnels requires in-flow acoustic measurements at high frequencies. This high frequency information is shifted to lower frequencies during the geometric scaling process. As a result, models of scale one tenth and smaller require frequency information of up to at least 100 kHz to resolve the midpoint of the full-scale equivalent audible range. Farfield acoustic measurements of frequencies higher than 100 kHz are prohibitively difficult to make due to the physical limitations of atmospheric propagation over large distances and the delicacy of the required instruments. Even measurements up to 100 kHz require special corrections and calibration procedures to maintain sufficient accuracy. In-flow microphone measurements at high frequencies require additional consideration due to the presence of the aerodynamic microphone forebody which protects the microphone diaphragm from flow impingement. The screen located at the forebody surface attenuates the high frequency acoustic waves and must be accounted for. The purpose of this paper is to present procedures for calibrating and correcting high frequency acoustic measurements to retain high accuracy. Specifically, this paper gives calibration procedures and examples of typical data for calibrating or correcting for five physical effects. These effects include the frequency response of the entire acoustic data acquisition system, intrusion of the microphone into the acoustic field, forebody screen attenuation, directionality of microphone forebody response and atmospheric absorption.

Allen, Christopher S.↗

Continuous-Flow System Produces Medical-Grade Water

A continuous-flow system utilizes microwave heating to sterilize water and to thermally inactivate endotoxins produced in the sterilization process. The system is designed for use in converting potable water to medical-grade water. Systems like this one could be used for efficient, small-scale production of medical- grade water in laboratories, clinics, and hospitals. This system could be adapted to use in selective sterilization of connections in ultra-pure-water-producing equipment and other equipment into which intrusion by microorganisms cannot be tolerated. Lightweight, port - able systems based on the design of this system could be rapidly deployed to remote locations (e.g., military field hospitals) or in response to emergencies in which the normal infrastructure for providing medical-grade water is disrupted. Larger systems based on the design of this system could be useful for industrial production of medical-grade water. The basic microwave-heating principle of this system is the same as that of a microwave oven: An item to be heated, made of a lossy dielectric material (in this case, flowing water) is irradiated with microwaves in a multimode microwave cavity. The heating is rapid and efficient because it results from absorption of microwave power throughout the volume of the lossy dielectric material. In this system, a copper tube having a length of 49.5 cm and a diameter of 2.25 cm serves as both the microwave cavity and the sterilization chamber. Microwave power is fed via a coaxial cable to an antenna mounted inside the tube at mid-length (see figure). Efficient power transfer occurs due to the shift in wavelength associated with the high permittivity of water combined with the strong coupling of 2.45-GHz microwaves with rotational-vibrational transitions of the dipolar water molecule.

Akse, James R.↗

Nature's Way of Making Audacious Space Projects Viable

Building a starship within the next 100 years is an audacious goal. To be successful, we need sustained funding that may be difficult to maintain in the face of economic challenges that are poised to arise during these next 100 years. Our species' civilization has only recently reached the classification as (approximately) Type-I on the Kardashev scale; that is, we have spread out from one small locality to become a global species mastering the energy and resources of an entire planet. In the process we discovered the profound truth that the two-dimensional surface of our world is not flat, but has positive curvature and is closed so that its area and resources are finite. It should come as no surprise to a Type I civilization when its planet's resources dWindle; how could they not? Yet we have gone year by year, government by government, making little investment for the time when civilization becomes violent in the unwelcome contractions that must follow, when we are forced too late into the inevitable choice: to remain and diminish on an unhappy world; or to expand into the only dimension remaining perpendicularly outward from the surface into space. Then some day we may become a Type-II civilization, mastering the resources of an entire solar system. Our species cannot continue as we have on this planet for another 100 years. Doubtless it falls on us today, the very time we intended to start building a starship, to make the late choice. We wished this century to be filled with enlightenment and adventure; it could be an age of desperation and war. What a time to begin an audacious project in space! How will we maintain consistent funding for the next 100 years? Fortunately, saving a civilization, mastering a solar system, and doing other great things like building starships amount to mostly the same set of tasks. Recognizing what we must be about during the next 100 years will make it possible to do them all.

Metzger, Philip T.↗

Combinatorial Multidomain Mesoporous Chips and a Method for Fractionation, Stabilization, and Storage of Biomolecules

A new fractionation device shows desirable features for exploratory screening and biomarker discovery. The constituent MSCs may be tailored for desired pore sizes and surface properties and for the sequestration and enrichment of extremely low abundant protein and peptides in desired ranges of the mass/charge spectrum. The MSCs are effective in yielding reproducible extracts from complex biological samples as small as 10 microliter in a time as short as 30 minutes. They are inexpensive to manufacture, and allow for scaled up production to attain the simultaneous processing of a large number of samples. The MSCs are multiplexed, label-free diagnostic tools with the potential of biological recognition moiety modification for enhanced specificity. The MSCs may store, protect and stabilize biological fluids, enabling the simplified and cost-effective collection and transportation of clinical samples. The MSC-based device may serve as a diagnostic tool to complement histopathology, imaging, and other conventional clinical techniques. The MSCs mediated identification of disease-specific protein signatures may help in the selection of personalized therapeutic combinations, in the real-time assessment of therapeutic efficacy and toxicity, and in the rational modulation of therapy based on the changes in the protein networks associated with the prognosis and the drug resistance of the disease.

Ferrari, Mauro↗

TESTING OF THE SECOND GENERATION SPINTEK ROTARY FILTER -11357

The SpinTek rotary microfilter has been developed under the Department of Energy (DOE) Office of Environmental Management (EM) for the purpose of deployment in radioactive service in the DOE complex. The unit that was fabricated and tested is the second generation of the filter that incorporates recommended improvements from previous testing. The completion of this test satisfied a key milestone for the EM technology development program and technology readiness for deployment by Savannah River Remediation in the Small Column Ion Exchange and Sludge Washing processes at the Savannah River Site (SRS). The Savannah River National Laboratory (SRNL) contracted SpinTek Filtration to fabricate a full scale 25 disk rotary filter and perform a 1000 hour endurance test with a simulated SRS sludge. Over 1500 hours of operation have been completed with the filter. SpinTek Filtration fabricated a prototypic 25 disk rotary filter including updates to manufacturing tolerances, an updated design to the rotary joint, improved cooling to the bottom journal, decreases in disk and filter shaft hydraulic resistances. The filter disks were fabricated with 0.5 {micro} pore size, sintered-metal filter media manufactured by Pall Corporation (M050). After fabrication was complete, the filter passed acceptance tests demonstrating rejection of solids and clean water flux with a 50% improvement over the previous filters. Once the acceptance test was complete, a 1000 hour endurance test was initiated simulating a sludge washing process. The test used a simulated SRS Sludge Batch 6 recipe. The insoluble solids started at 5 wt% and were raised to 10 and 15 wt% insoluble solids to simulate the concentration of a large volume tank. The filter system was automated and set up for 24 hour unattended operation. To facilitate this, process control logic was written to operate the filter. During the development it was demonstrated that the method of starting and stopping the filter can affect the build up of filter cake on the disks and therefore the performance of the filter. The filter performed well with the simulant. Very little drop in production was noticed between the 5 and 10 wt% insoluble solids feed. Increasing to 15 wt% had a more pronounced impact due to the rheology of the feed. Acid cleaning was used to clean the filter disks in-situ and restore filtration rate to almost 90% of the initial clean disk rate. Eighty liters of 0.2 M nitric acid in conjunction with water rinses were used to clean the filter in less than 2 hours. Filter testing was completed after 1000 hours of operation were performed on the final filter assembly configuration. The total run time for the testing was over 1500 hours. At the end of the test, the sludge washing was performed successfully from approximately 5.6 M to less than 1 M sodium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Scale-Up of Copper-Based Chemical Looping with Oxygen Uncoupling

The University of Utah has been researching chemical looping with oxygen uncoupling of coal since 2007, focusing on copper-based carriers and a system configuration based on two interconnected circulating fluidized bed reactors. R&D has combined fundamental, lab-scale systems with operation of CLOU reactor systems at various scales and computational simulations for performance evaluation and reactor scale-up. Development has progressed from small lab scale through bench scale with a 10 kW dual bed research reactor to semi-pilot scale with a recently-inaugurated 220 kW chemical looping combustion process development unit. One of the challenges of scaling up copper-based CLOU technology is acquiring enough oxygen carrier material to support operation in larger reactor systems. The UofU CLC PDU, for example, requires 150-200 kg of inventory, so the oxygen carrier must be readily available in large quantities at comparatively low cost. Because no supplier capable of delivering 1+ tons of copper-based oxygen carrier material could be identified, an inexpensive oxygen carrier material was developed in-house and the carrier production process was scaled to produce large quantities of material sufficient for the CLC PDU. This presentation describes development of the CLOU process at the University of Utah, including evaluation of fundamental processes key to performance of CLOU, modeling and scale-up of the process, large-scale production of copper based oxygen carrier material and experience to date with the world’s largest dedicated CLOU reactor.

Whitty, Kevin J.↗

Electrochemical Membrane for Carbon Dioxide Capture and Power Generation

FuelCell Energy, Inc. (FCE), in collaboration with AECOM Corporation (formerly URS Corporation) and Pacific Northwest National Laboratory, has been developing a novel Combined Electric Power and Carbon-dioxide Separation (CEPACS) system. The CEPACS system is based on electrochemical membrane (ECM) technology derived from FCE’s carbonate fuel cell products featuring internal (methane steam) reforming and carrying the trade name of Direct FuelCell®. The unique chemistry of carbonate fuel cells offers an innovative approach for separation of CO 2 from existing fossil-fuel power plant exhaust streams (flue gases). The ECM-based CEPACS system has the potential to become a transformational CO 2 -separation technology by working as two devices in one: it separates the CO 2 from the exhaust of other plants such as an existing coal-fired plant and simultaneously produces clean electric power at high efficiency using a supplementary fuel. The development effort was carried out under the U.S. Department of Energy (DOE) cooperative agreement DE-FE0007634. The overall objective of this project was to successfully demonstrate the ability of FCE’s ECM-based CEPACS system technology to separate ≥90% of the CO 2 from a simulated Pulverized Coal (PC) power plant flue gas stream and to compress the captured CO2 to a state that can be easily transported for sequestration or beneficial use. In addition, a key objective was to show, through the technical and economic feasibility study and bench scale testing, that the ECM-based CEPACS system is an economical alternative for CO 2 capture in PC power plants, and that it meets DOE’s objective related to the incremental cost of electricity (COE) for post-combustion CO 2 capture (no more than 35% increase in COE). The project was performed in three budget periods (BP). The specific objective for BP1 was to complete the Preliminary Technical and Economic Feasibility Study. The T&EF study was based on the carbon capture system size suitable for a reference 550 MW PC power plant. The specific objectives for BP2 were to perform (flue gas) contaminant effect evaluation tests, small area membrane tests using clean simulated flue gas, design a flue gas pretreatment system for processing of the gas feed to ECM, update the Technical & Economic Feasibility Study (T&EFS) incorporating results of contaminant effect tests and small area membrane tests, and to prepare a test facility for bench scale testing. The specific objectives for BP3 were to perform bench scale testing (parametric and long-duration testing) of a 11.7 m 2 ECM-based CO 2 capture, purification and compression system, and update (as final) the Technical and Economic Feasibility Study. In addition, an Environmental Health and Safety evaluation (assessment) of the ECM technology was included. This final technical report presents the progress made under the project.

20 FOSSIL-FUELED POWER PLANTS↗

Baryonic effects in the Effective Field Theory of Large-Scale Structure and an analytic recipe for lensing in CMB-S4

Upcoming Large-Scale Structure surveys will likely become the next leading sources of cosmological information, making it crucial to have a precise understanding of the influence of baryons on cosmological observables. The Effective Field Theory of Large-Scale Structure (EFTofLSS) provides a consistent way to predict the clustering of dark matter and baryons on large scales, where their leading corrections in perturbation theory are given by a simple and calculable functional form even after the onset of baryonic processes. In this paper, we extend the two-fluid-like system up to two-loop order in perturbation theory. Along the way, we show that a new linear counterterm proportional to the relative velocity of the fluids could generically be present, but we show that its effects are expected to be small in our universe. Regardless, we show how to consistently perform perturbation theory in the presence of this new term. We find that the EFTofLSS at two-loop order can accurately account for the details of baryonic processes on large scales. Additionally, we compare our results to a hydrodynamical N-body simulation at many redshifts and find that the counterterms associated with the leading corrections to dark matter and baryons start to differ between redshifts z ≈ 3 and z ≈ 2, signaling the onset of star-formation physics. We then use these fits to compute the lensing power spectrum, show that the understanding of baryonic processes will be important for analyzing CMB-S4 data, and show that the two-loop EFTofLSS accurately captures these effects for ℓ ≲ 2000. Our results are also potentially of interest for current and future weak lensing surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanofiltration across Defect-Sealed Nanoporous Monolayer Graphene

Monolayer nanoporous graphene represents an ideal membrane for molecular separations, but its practical realization is impeded by leakage through defects in the ultrathin graphene. Here, we report a multiscale leakage-sealing process that exploits the nonpolar nature and impermeability of pristine graphene to selectively block defects, resulting in a centimeter-scale membrane that can separate two fluid reservoirs by an atomically thin layer of graphene. After introducing subnanometer pores in graphene, the membrane exhibited rejection of multivalent ions and small molecules and water flux consistent with prior molecular dynamics simulations. The results indicate the feasibility of constructing defect-tolerant monolayer graphene membranes for nanofiltration, desalination, and other separation processes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The cold land processes experiment (CLPX) local scale observatin site (LSOS)

The Local Scale Observation Site (LSOS) is the smallest study site of the Cold LandProcesses Experiment (CLPX) and is located within the Fraser Meso-cell Study Area (MSA), near the Fraser Experimental Forest Headquarters Facility, in Fraser, CO USA.The 100-m x 100-m site consists of a small open field, a managed dense canopy and an open, mixed age canopy. Unlike the other components of the experiment, which focus on spatial distributions at relatively brief snapshots in time, measurements at the local scale site focused on the temporal domain.

cold land processes ground-based remote sensing va↗

Dark matter isocurvature from curvature

Isocurvature fluctuations, where the relative number density of particle species spatially varies, can be generated from initially adiabatic, or curvature, fluctuations if the various species fall out of or were never in thermal equilibrium. The freezing of the thermal relic dark matter abundance is one such case, but for modes that are still outside the horizon the amplitude is highly suppressed and originates from the small change in the local expansion rate due to the local space curvature produced by the curvature fluctuation. We establish a simple separate-universe method for calculating this generation that applies to both freeze-in and freeze-out models, identify three critical epochs for this process, and give general scaling behaviors for the amplitude in each case: the freezing epoch, the kinetic decoupling epoch and matter-radiation equality. Freeze-out models are typically dominated by spatially modulated annihilation from the latter epochs and can generate much larger isocurvature fluctuations compared with typical freeze-in models, albeit still very small and observationally allowed by cosmic microwave background measurements. Here, we illustrate these results with concrete models where the dark matter interactions are vector or scalar mediated.

79 ASTRONOMY AND ASTROPHYSICS↗

UPRE method for total variation parameter selection

Total Variation (TV) Regularization is an important method for solving a wide variety of inverse problems in image processing. In order to optimize the reconstructed image, it is important to choose the optimal regularization parameter. The Unbiased Predictive Risk Estimator (UPRE) has been shown to give a very good estimate of this parameter for Tikhonov Regularization. In this paper we propose an approach to extend UPRE method to the TV problem. However, applying the extended UPRE is impractical in the case of inverse problems such as de blurring, due to the large scale of the associated linear problem. We also propose an approach to reducing the large scale problem to a small problem, significantly reducing computational requirements while providing a good approximation to the original problem.

99 GENERAL AND MISCELLANEOUS↗

Size dependent fragmentation of argon clusters in the soft x-ray ionization regime

Photofragmentation of argon clusters of average size ranging from 10 up to 1000 atoms is studied using soft x-ray radiation below the 2p threshold and multicoincidence mass spectroscopy technique. For small clusters (<N>=10), ionization induces fast fragmentation with neutral emission imparting a large amount of energy. While the primary dissociation takes place on a picosecond time scale, the fragments undergo slow degradation in the spectrometer on a microsecond time scale. For larger clusters (<N>{>=}100) we believe that we observe the fragmentation pattern of multiply charged species on a time-scale which lasts a few hundred nanoseconds. The reason for these slower processes is the large number of neutral atoms which act as an efficient cooling bath where the excess energy ('heat') dissipates among all degrees of freedom. Further degradation of the photoionic cluster in spectrometer then takes place on the microsecond time scale, similar to small clusters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Slipstream pilot-scale demonstration of a novel amine-based post-combustion technology for carbon dioxide capture from coal-fired power plant flue gas

Post-combustion CO 2 capture (PCC) technology offers flexibility to treat the flue gas from both existing and new coal-fired power plants and can be applied to treat all or a portion of the flue gas. Solvent-based technologies are today the leading option for PCC from commercial coal-fired power plants as they have been applied in large-scale in other applications. Linde and BASF have been working together to develop and further improve a PCC process incorporating BASF’s novel aqueous amine-based solvent technology. This technology offers significant benefits compared to other solvent-based processes as it aims to reduce the regeneration energy requirements using novel solvents that are very stable under the coal-fired power plant feed gas conditions. BASF has developed the desired solvent based on the evaluation of a large number of candidates. In addition, long-term small pilot-scale testing of the BASF solvent has been performed on a lignite-fired flue gas. In coordination with BASF, Linde has evaluated a number of options for capital cost reduction in large engineered systems for solvent-based PCC technology. This report provides a summary of the work performed and results from a project supported by the US DOE (DE-FE0007453) for the pilot-scale demonstration of a Linde-BASF PCC technology using coal-fired power plant flue gas at a 1-1.5 MWe scale in Wilsonville, AL at the National Carbon Capture Center (NCCC). Following a project kick-off meeting in November 2011 and the conclusion of pilot plant design and engineering in February 2013, mechanical completion of the pilot plant was achieved in July 2014, and final commissioning activities were completed to enable start-up of operations in January 2015. Parametric tests were performed from January to December 2015 to determine optimal test conditions and evaluate process performance over a variety of operation parameters. A long-duration 1500-hour continuous test campaign was performed from May to August 2016 at a selected process condition to evaluate process performance and solvent stability over a longer period similar to how the process would operate as a continuously running large-scale PCC plant. The pilot plant integrated a number of unique features of the Linde-BASF technology aimed at lowering overall energy consumption and capital costs. During the overall test period including startup, parametric testing and long-duration testing, the pilot plant was operated for a total of 6,764 hours out of which testing with flue gas was performed for 4,109 hours. The pilot plant testing demonstrated all of the performance targets including CO 2 capture rate exceeding 90%, CO 2 purity exceeding 99.9 mol% (dry), flue gas processing capacity up to 15,500 lbs/hr (equivalent to 1.5 MWe capacity slipstream), regeneration energy as low as 2.7 GJ/tonne CO 2 , and regenerator operating pressure up to 3.4 bara. Excellent solvent stability performance data was measured and verified by Linde and BASF during both test campaigns. In addition to process data, significant operational learnings were gained from pilot tests that will contribute greatly to the commercial success of PCC. Based on a thorough techno-economic assessment (TEA) of the Linde-BASF PCC process integrated with a 550 MWe supercritical coal-fired power plant, the net efficiency of the integrated power plant with CO 2 capture is increased from 28.4% with the DOE/NETL Case 12 reference to 30.9% with the Linde-BASF PCC plant previously presented utilizing the BASF OASE® blue solvent [Ref. 4], and is further increased to 31.4% using a Linde-BASF PCC plant with BASF OASE® blue solvent and an advanced stripper interstage heater (SIH) configuration. The Linde-BASF PCC plant incorporating the BASF OASE® blue solvent also results in significantly lower overall capital costs, thereby reducing the cost of electricity (COE) and cost of CO 2 captured from $147.25/MWh and $56.49/MT CO 2 , respectively, for the reference DOE/NETL Case 12 plant, to $128.49/MWh and $41.85/MT CO2 for process case LB1, respectively, and $126.65/MWh and $40.66/MT CO 2 for process case SIH, respectively. With additional innovative Linde-BASF PCC process configuration improvements, the COE and cost of CO 2 captured can be further reduced to $125.51/MWh and $39.90/MT CO 2 for a further optimized PCC process defined as LB1-CREB. Most notably, the Linde-BASF process options assessed have already demonstrated the potential to lower the cost of CO 2 captured below the DOE target of $40/MT CO 2 at the 550 MWe scale for second generation PCC technologies. Project organization, structure, goals, tasks, accomplishments, process criteria and milestones will be presented in this report along with highlights and key results from parametric and long-duration testing of the Linde-BASF PCC pilot. The parametric and long-duration testing campaigns were aimed at validating the performance of the PCC technology against targets determined from a preliminary techno-economic assessment. The stability of the solvent with extended operation in a realistic power plant setting was measured with performance verified. Additionally, general solvent classification information, process operating conditions, normalized solvent performance data, solvent stability test results, flue gas conditions data, CO 2 purity data in the gaseous product stream, steam requirements and process flow diagrams, and updated process economic data for a scaled-up 550 MWe supercritical power plant with CO 2 capture are presented and discussed in this report.

20 FOSSIL-FUELED POWER PLANTS↗

Development and Demonstration of Large-Scale Metal Additive Manufacturing for Military Vehicle Applications (Final Report)

Additive Manufacturing (AM) is a process by which complex parts can be manufactured directly from a basic feedstock without the need for tooling. From a defense perspective, this will enable direct manufacture of parts for legacy equipment. However, current AM technologies are limited to small part sizes (approximately 1 cubic foot), slow production rates (approximately 1 cubic inch per hour) and expensive feedstocks (approximately $100/lb). The objective of this project was to explore the impact large-scale, high production rate additive manufacturing can have on military applications. First, the program explored the use of existing composite large-scale (Big Area Additive Manufacturing – BAAM) systems for both tooling and direct part replacement with the use of the Army’s Low Velocity Airdrop Delivery (LVAD) system and Willy’s Jeep. We report on the cost and time required for the development of both tooling and parts. Second, the program focused on expanding the BAAM technology to directly manufacture aluminum and steel components. A robotic welding system was developed, test articles manufactured and with a final deliverable of a steel bumper manufactured and installed on the Jeep. This report covers the results of the program and describes follow-on efforts to commercialize the technology.

36 MATERIALS SCIENCE↗

Volcanism in the cratered terrain hemisphere of Mars

Four kinds of Martian volcanoes and their prevalences in the cratered terrain hemisphere (generally the southern hemisphere) are described. Patera, which are large low-profile volcanic structures, appear to be either older shield volcanoes or a unique type of volcano. 'Plains' volcanics represent low-volume eruptions that formed cones, low shields, and other small-scale structures. Flood volcanics are produced by high-volume eruptions, post-date the older and more degraded plateau plains, and occur mostly as basin-fill materials. Plateau plains, the Martian intercrater plains, contain many wrinkle ridges and floor-fractured craters. It is suggested that volcanic processes as well as erosional processes have been important in obliterating small Martian craters and that volcanic products may constitute a significant fraction (up to 44%) of the surface rocks in the cratered terrain

Greeley, R.↗

INTERNATIONAL STUDIES OF ENHANCED WASTE LOADING AND IMPROVED MELT RATE FOR HIGH ALUMINA CONCENTRATION NUCLEAR WASTE GLASSES

The goal of this study was to determine the impacts of glass compositions with high aluminum concentrations on melter performance, crystallization and chemical durability for Savannah River Site (SRS) and Hanford waste streams. Glass compositions for Hanford targeted both high aluminum concentrations in waste sludge and a high waste loading in the glass. Compositions for SRS targeted Sludge Batch 5, the next sludge batch to be processed in the Defense Waste Processing Facility (DWPF), which also has a relatively high aluminum concentration. Three frits were selected for combination with the SRS waste to evaluate their impact on melt rate. The glasses were melted in two small-scale test melters at the V. G. Khlopin Radium Institute. The results showed varying degrees of spinel formation in each of the glasses. Some improvements in melt rate were made by tailoring the frit composition for the SRS feeds. All of the Hanford and SRS compositions had acceptable chemical durability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗