Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Highly effective fungal inactivation in He+O{sub 2} atmospheric-pressure nonequilibrium plasmas

Highly effective (more than 99.9%) inactivation of a pathogenic fungus Candida albicans commonly found in oral, respiratory, digestive, and reproduction systems of a human body using atmospheric-pressure plasma jets sustained in He+O{sub 2} gas mixtures is reported. The inactivation is demonstrated in two fungal culture configurations with open (Petri dish without a cover) and restricted access to the atmosphere (Petri dish with a cover) under specific experimental conditions. It is shown that the fungal inactivation is remarkably more effective in the second configuration. This observation is supported by the scanning and transmission electron microscopy of the fungi before and after the plasma treatment. The inactivation mechanism explains the experimental observations under different experimental conditions and is consistent with the reports by other authors. The results are promising for the development of advanced health care applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of Processing and Structure in an Ethylene‐Glycol Side‐Chain Modified Polythiophene via Combined X‐Ray Scattering and 4D Scanning Transmission Electron Microscopy

The results of a combined grazing incidence wide-angle X-ray scattering (GIWAXS) and 4D scanning transmission microscopy (4D-STEM) analysis of the effects of thermal processing on poly(3[2-(2-methoxyethoxy)ethoxy]-methylthiophene-2,5-diyl) are reported, a conjugated semiconducting polymer used as the active layer in organic electrochemical transistor devices. GIWAXS provides a measure of overall crystallinity in the film, while 4D-STEM produces real-space maps of the morphology and orientation of individual crystallites along with their spatial extent and distribution. The sensitivity of the 4D-STEM detector allows for collection of electron diffraction patterns at each position in an image scan while limiting the imparted electron dose to below the damage threshold. In conclusion, the effects of heat treatment on the distribution and type of crystallites present in the films is determined.

36 MATERIALS SCIENCE↗

Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes

PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transparent Carbon Ultramicroelectrode Arrays: Figures of Merit for Quantitative Spectroelectrochemistry for Biogenic Analysis of Reactive Oxygen Species

Opaque and transparent carbon ultramicro- to nanoelectrode arrays were made using a previously reported facile versatile fabrication method (Duay et al. Anal. Chem. 2014, 86, 11528). Initially, opaque carbon ultramicroelectrode arrays (CUAs) were characterized for their analytical response to hydrogen peroxide (H 2 O 2 ) oxidation using cyclic voltammetry. The alumina blocking layer was found to contribute to the noise and thus had undesirable effects on the array’s limit of detection (LOD) for H 2 O 2 at fast scan rates. Nonetheless, at slower scan rates (ν ≤ 250 mV s –1 ), the LODs for H 2 O 2 for both opaque (O-CUAs) and transparent arrays (T-CUAs) were discovered to be lower than previously reported levels for array-based UMEs. LODs as low as 35 nM H 2 O 2 are obtained for T-CUA at a 2.5 mV s –1 scan rate. Furthermore, the transparent arrays were analyzed for their spectroelectrochemical response during the oxidation/reduction of ferrocenemethanol. Results showed very good correlation between the optical and electrochemical response for ferrocenemethanol at a UV wavelength of 254 nm. Thus, these electrodes allow for the in situ mechanistic and kinetic characterization of heterogeneous electrochemical and intermediate homogeneous chemical reactions with high electroanalytical sensitivity, low detection limits, and wide dynamic range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of proton therapy treatment planning for head tumors with a pencil beam algorithm on dual and single energy CT images

Purpose: Dual energy CT (DECT) has recently been proposed as an improvement over single energy CT (SECT) for stopping power ratio (SPR) estimation for proton therapy treatment planning (TP), thereby potentially reducing range uncertainties. Published literature investigated phantoms. This study aims at performing proton therapy TP on SECT and DECT head images of the same patients and at evaluating whether the reported improved DECT SPR accuracy translates into clinically relevant range shifts in clinical head treatment scenarios. Methods: Two phantoms were scanned at a last generation dual source DECT scanner at 90 and 150 kVp with Sn filtration. The first phantom (Gammex phantom) was used to calibrate the scanner in terms of SPR while the second served as evaluation (CIRS phantom). DECT images of five head trauma patients were used as surrogate cancer patient images for TP of proton therapy. Pencil beam algorithm based TP was performed on SECT and DECT images and the dose distributions corresponding to the optimized proton plans were calculated using a Monte Carlo (MC) simulation platform using the same patient geometry for both plans obtained from conversion of the 150 kVp images. Range shifts between the MC dose distributions from SECT and DECT plans were assessed using 2D range maps. Results: SPR root mean square errors (RMSEs) for the inserts of the Gammex phantom were 1.9%, 1.8%, and 1.2% for SECT phantom calibration (SECT{sub phantom}), SECT stoichiometric calibration (SECT{sub stoichiometric}), and DECT calibration, respectively. For the CIRS phantom, these were 3.6%, 1.6%, and 1.0%. When investigating patient anatomy, group median range differences of up to −1.4% were observed for head cases when comparing SECT{sub stoichiometric} with DECT. For this calibration the 25th and 75th percentiles varied from −2% to 0% across the five patients. The group median was found to be limited to 0.5% when using SECT{sub phantom} and the 25th and 75th percentiles varied from −1% to 2%. Conclusions: Proton therapy TP using a pencil beam algorithm and DECT images was performed for the first time. Given that the DECT accuracy as evaluated by two phantoms was 1.2% and 1.0% RMSE, it is questionable whether the range differences reported here are significant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Build orientation, surface roughness, and scan path influence on the microstructure, mechanical properties, and flexural fatigue behavior of Ti–6Al–4V fabricated by electron beam melting

In the present work, microstructure and fatigue behavior of Electron Beam Melted (EBM) Ti–6Al–4V have been systematically studied. Fatigue behavior was investigated using four-point bend tests of rectangular bars with internal features fabricated with different build orientations, scan paths, and surface conditions. Microstructural variations were evaluated by optical microscopy and Vickers micro-hardness indentations, both of which were found to be consistent throughout the build and within ranges reported in the literature. The fatigue performance of the EBM material was comparable to wrought Ti–6Al–4V when the loading direction was parallel to the build direction, but severely limited when loaded perpendicular to the build direction or if surface roughness defects were present. Scanning electron microscopy and interrupted fatigue tests were utilized to characterize fracture surfaces, failure mechanisms, crack initiation, and propagation behavior. Crack initiation sites in the vertically-oriented specimens were identified to be melt-related defects formed by insufficient melting.

36 MATERIALS SCIENCE↗

Nanofabrication of Doped, Complex Oxides

Complex oxides have many promising attributes, including wide band gaps for high temperature semiconductors, ion conducting electrolytes in fuel cells, ferroelectricity and ferromagnetism. Bulk and thin film oxides can be readily manufactured and tested however these physically hard and chemically inert materials cannot be nanofabricated by direct application of conventional methods. In order to study these materials at the nanoscale there must first be a simple and effective means to achieve the desired structures. Here we discuss the use of pulsed laser deposition at room temperature onto electron beam lithography defined templates of poly methyl methacrylate photoresist. Following a resist liftoff in organic solvents, a heat treatment was used to crystallize the nanostructures. The morphology of these structures was studied using scanning electron microscopy and atomic force microscopy. Crystallinity and composition as determined by x ray diffraction and photo-electron spectroscopy respectively is reported for thin film analogues of the nanostructured oxide. The oxide studied in this report is Nb doped SrTiO{sub 3}, which has been investigated for use as a high temperature thermoelectric material; however the approach used is not materials-dependent.

30 DIRECT ENERGY CONVERSION↗

TH-AB-209-10: Breast Cancer Identification Through X-Ray Coherent Scatter Spectral Imaging

Purpose: We have previously described the development and testing of a coherent-scatter spectral imaging system for identification of cancer. Our prior evaluations were performed using either tissue surrogate phantoms or formalin-fixed tissue obtained from pathology. Here we present the first results from a scatter imaging study using fresh breast tumor tissues obtained through surgical excision. Methods: A coherent-scatter imaging system was built using a clinical X-ray tube, photon counting detectors, and custom-designed coded-apertures. System performance was characterized using calibration phantoms of biological materials. Fresh breast tumors were obtained from patients undergoing mastectomy and lumpectomy surgeries for breast cancer. Each specimen was vacuum-sealed, scanned using the scatter imaging system, and then sent to pathology for histological workup. Scatter images were generated separately for each tissue specimen and analyzed to identify voxels containing malignant tissue. The images were compared against histological analysis (H&E + pathologist identification of tumors) to assess the match between scatter-based and histological diagnosis. Results: In all specimens scanned, the scatter images showed the location of cancerous regions within the specimen. The detection and classification was performed through automated spectral matching without the need for manual intervention. The scatter spectra corresponding to cancer tissue were found to be in agreement with those reported in literature. Inter-patient variability was found to be within limits reported in literature. The scatter images showed agreement with pathologist-identified regions of cancer. Spatial resolution for this configuration of the scanner was determined to be 2–3 mm, and the total scan time for each specimen was under 15 minutes. Conclusion: This work demonstrates the utility of coherent scatter imaging in identifying cancer based on the scatter properties of the tissue. It presents the first results from coherent scatter imaging of fresh (unfixed) breast tissue using our coded-aperture scatter imaging approach for cancer identification.

60 APPLIED LIFE SCIENCES↗

Highly thermally stable copolymers of epoxy and trifunctional polybenzoxazine

Here, in this work, we report the copolymerization of a triamine-based benzoxazine and a commercial difunctional epoxy resin, and investigate their synergistic effect on improved thermal properties using differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Results showed that a glass transition temperature increase of up to 268 °C was obtained for the copolymer with as low as 25 wt% epoxy. A higher thermal performance was also achieved with an onset degradation of nearly 400 °C and char yield of 39 wt% at 800 °C for the copolymer with 52 wt% epoxy. The behavior was compared to previously reported benzoxazine/epoxy combinations and was found to be advantageous. The curing behavior of different copolymer compositions was also investigated via DSC and a methodology for matching each peak with its corresponding reaction was developed. Results showed that the alternating favorability of the reactions was dependent on the benzoxazine/epoxy ratio. Overall, the prepared PBZ/epoxy copolymers displayed higher thermal stability than their individual components, indicating suitability for a number of potential extended uses including utility in higher temperature applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Verification Survey Report of the South Waste Tank Farm Training/Test Tower and hazardous Waste Storage Lockers at the West Valley Demonstration Project, West Valley, New York (Final Report)

A team from ORAU's Independent Environmental Assessment and Verification Program performed verification survey activities on the South Test Tower and four Hazardous Waste Storage Lockers. Scan data collected by ORAU determined that both the alpha and alpha-plus-beta activity was representative of radiological background conditions. The count rate distribution showed no outliers that would be indicative of alpha or alpha-plus-beta count rates in excess of background. It is the opinion of ORAU that independent verification data collected support the site's conclusions that the South Tower and Lockers sufficiently meet the site criteria for release to recycle and reuse.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flexible Fuel Electric Hybrid Glass Furnace Demonstration

The furnace contractor completed General Arrangement (GA) layouts and Piping and Instrumentation Diagrams (P&ID) for both furnaces during this reporting period. Preliminary equipment lists accompanied this work. Control system architecture in progress. Key furnace design elements and deliverables on track to be complete by end of phase. The facilities design and integration contractor completed a 3D scan and modeling of the facility. The work during this period focused on preliminary design with a focus on overall project scope and feasibility. This key work supports the overall project deliverables for 30% preliminary engineering and Preliminary Design Report (PDR) which are on track to be complete by the end of the phase. These deliverables are approximately 50% complete through the end of this reporting period. The batch house operations design contractor continues development of site plan and General Arrangement (GA) layout to support the 30% preliminary engineering and design package. This work is 60% complete by the end of this reporting period and is on track to be complete by the end of the phase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EOS Aqua AMSR-E Arctic Sea Ice Validation Program: Arctic2003 Aircraft Campaign Flight Report

In March 2003 a coordinated Arctic sea ice validation field campaign using the NASA Wallops P-3B aircraft was successfully completed. This campaign was part of the program for validating the Earth Observing System (EOS) Aqua Advanced Microwave Scanning Radiometer (AMSR-E) sea ice products. The AMSR-E, designed and built by the Japanese National Space Development Agency for NASA, was launched May 4, 2002 on the EOS Aqua spacecraft. The AMSR-E sea ice products to be validated include sea ice concentration, sea ice temperature, and snow depth on sea ice. This flight report describes the suite of instruments flown on the P-3, the objectives of each of the seven flights, the Arctic regions overflown, and the coordination among satellite, aircraft, and surface-based measurements. Two of the seven aircraft flights were coordinated with scientists making surface measurements of snow and ice properties including sea ice temperature and snow depth on sea ice at a study area near Barrow, AK and at a Navy ice camp located in the Beaufort Sea. Two additional flights were dedicated to making heat and moisture flux measurements over the St. Lawrence Island polynya to support ongoing air-sea-ice processes studies of Arctic coastal polynyas. The remaining flights covered portions of the Bering Sea ice edge, the Chukchi Sea, and Norton Sound.

Cavalieri, D. J.↗

Smaller and faster: a review of conventional and nanocalorimetry techniques for determining thermophysical properties of nuclear materials

Thermal analysis of nuclear materials is critical for the advancement of nuclear technology. The heat effects associated with heat capacity, phase transformation, and radiation damage can be measured with conventional calorimeters. However, conventional calorimetric techniques are often restricted in terms of heating rate and sample mass, especially when studying the limited amounts of materials subject to extreme conditions. In this review, we summarize conventional calorimetric studies of critical thermophysical and thermochemical properties of pure actinide metals (U, Np, Am, Pu), fast reactor metallic fuel alloy systems (U–Zr, U–Pu–Zr, Pu–U, Pu–Zr), and actinide oxides that are primary constituents or transmutation products in light water reactor fuel rods (U–O, Np–O, Am–O, Pu–O, Pu–U–O). Adiabatic and drop calorimetry have been the primary techniques used for these studies, however the development of fast scanning calorimetry using micro-electro-mechanical-based systems allows determination of thermodynamic properties from smaller sample masses. We report recent investigations that leverage the fast heating rates of nanocalorimetry by itself or combined with other characterization techniques. Furthermore, we then discuss opportunities for nanocalorimetry to provide solutions to some of the technical challenges inherent in thermal analysis of nuclear materials, namely a reduction in sample activity, emulating heating transients, investigation of phase evolution in irradiated samples, and characterization of radiation damage evolution. Nanocalorimetry has the potential to significantly advance the understanding of thermophysical properties in nuclear materials and thus accelerate the development of nuclear technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Epsilon Metal Waste Form for Immobilization of Noble Metals from Used Nuclear Fuel

Epsilon metal (ε-metal), an alloy of Mo, Pd, Rh, Ru, and Tc, is being developed as a waste form to treat and immobilize the undissolved solids and dissolved noble metals from aqueous reprocessing of commercial used nuclear fuel. Epsilon metal is an attractive waste form for several reasons: increased durability relative to borosilicate glass, it can be fabricated without additives (100% waste loading), and in addition it also benefits borosilicate glass waste loading by eliminating noble metals from the glass and thus the processing problems related there insolubility in glass. This work focused on the processing aspects of the epsilon metal waste form development. Epsilon metal is comprised of refractory metals resulting in high reaction temperatures to form the alloy, expected to be 1500 - 2000°C making it a non-trivial phase to fabricate by traditional methods. Three commercially available advanced technologies were identified: spark-plasma sintering, microwave sintering, and hot isostatic pressing, and investigated as potential methods to fabricate this waste form. Results of these investigations are reported and compared in terms of bulk density, phase assemblage (X-ray diffraction and elemental analysis), and microstructure (scanning electron microscopy).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A convenient sol-gel route for the synthesis of salicylate-titania nanocomposites having visible absorption and blue luminescence

Syntheses of titania-based nanomaterials by simple sol-gel route using a mixture of CTAB and salicylate as well as salicylate ions as templates have been reported. The materials are characterized by the powder X-ray diffraction (XRD), thermal analysis, transmission electron microscopy (TEM), scanning electron microscopy (SEM) and spectroscopic (FT IR, UV-VIS) analyses. A disordered mesoscale orientation of nanoparticles (ca. 2-4 nm) composed of TiO{sub 2}-salicylate surface complex has been obtained when 1:1 mixing ratio of CTAB and salicylate at the CTAB concentration of 0.001 M was employed as a template. All these nanocomposites exhibit a considerable red shift at the onsets of their absorption band compared to pure (organic-free) nanocrystalline TiO{sub 2} and show blue luminescence at room temperature. This assembly of nanoparticles is highly interesting in the context of visible light sensitization and nanodevice fabrication. - Graphical abstract: A new titania-salicylate nanostructure material has been synthesized, which exhibit a considerable red shift towards the visible region vis-a-vis nanocrystalline (organic-free) TiO{sub 2} and blue luminescence at room temperature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Precipitation in Mg-Gd-Y-Zr Alloy: Atomic-scale insights into structures and transformations

This paper reports on a comprehensive investigation, using atomic-scaled C{sub s} corrected high angle annular dark field-scanning transmission electron microscopy (HAADF-STEM), of the precipitation in Mg-9.28Gd-2.93Y-0.35Zr, including structures of the precipitates and several structural transformation processes. The precipitation sequence is identified as: Super saturated solid solution → clusters → nucleation β{sup '} (major)/ β{sub H} (minor)→ precipitate β{sup '} (major)/ β{sub M} , β{sub T}{sup '} (minor)→β{sub 1} → β(Equilibrium). Under peak-age condition, the strengthening structure is independent defect-free β{sup '} with little interaction among each other. Under over-age condition, the β{sup '} precipitates start to interact with each other, during which coarsening and orientation transformation of β{sup '} precipitates take place. The coarsening and orientation transformation, in which some RE atoms in the precipitates need to change their positions, are achieved by β{sub M} and β{sub T}{sup '} as transitional structures. - Highlights: • The precipitation in Mg-Gd-Y-Zr is comprehensively investigated by advanced atomic-scale Cs-corrected HAADF-STEM. • Various novel precipitate structures are unraveled. • Four types of interfaces between the precipitates are fully characterized. • The structural transformation processes of the precipitates are revealed.

36 MATERIALS SCIENCE↗