Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Energy-valley-dependent charge transfer in few-layer transition metal dichalcogenide heterostructures

The effect of the energy valley on interlayer charge transfer in transition metal dichalcogenide (TMD) heterostructures is studied by transient absorption spectroscopy and density functional theory. First-principles calculations confirm that the Λ min valley in the conduction band of few-layer WSe 2 evolves from above its K valley in the monolayer (1L) to below it in 4L. Heterostructure samples of nL–WSe 2 /1L–MoS 2 , where n = 1,2,3, and 4, are obtained by mechanical exfoliation and dry transfer. Photoluminescence spectroscopy reveals a thickness-dependent WSe 2 band structure and efficient interlayer charge transfer. Transient absorption measurements show that the electron transfer time from the Λ min valley of 4L WSe 2 to the K valley of MoS 2 is on the order of 30 ps. This process is much slower than the K-K charge transfer in 1L/1L TMD heterostructures. Furthermore, the momentum-indirect interlayer excitons formed after charge transfer have lifetimes >1 ns.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study of electro-physical properties of CsPbBr3 perovskite single crystals

Methods have been developed for the synthesis and growth of lead halide perovskites CsPbBr3, which can be used as detectors of optical, X-ray and gamma-radiation. Single crystals of these compounds were grown by the Bridgman method. The melt temperature was 580 °C, the gradient at the crystallization front was 5 K/cm, and the ampoule lowering speed was 3 mm/hour. In this work, the electro-physical properties of the inorganic perovskite CsPbBr3 were investigated. Crystals for research were cut from the beginning and end of the ingot. The optical absorption spectra were measured depending on the crystal thickness and temperature, the differential resistivity dif and the product  were determined from the I-V characteristics. It was established that dif practically does not change for samples made from the beginning and the end of the ingot, and is dif  21010 Ωcm at 100 V and 293 K.

Sklyarchuk, V.↗

Second Target Station (STS) Project: PIONEER Technical Report

PIONEER is a time-of-flight single-crystal neutron diffractometer at the Second Target Station (STS), aiming at providing the world-leading capability to measure tiny crystals (~0.001 mm 3 , i.e., X-ray diffraction size), ultra-thin epitaxial films (~10 nm thicknesses), and weak structural transitions and complex magnetism. The instrument will take advantage of STS source characteristics and utilize advancements in neutron optics to largely reduce the sample-volume requirement for single-crystal neutron diffraction. PIONEER will have a high-flux mode with multiple beam size options to improve the signal-to-background ratio in various sample environments. It will also provide a high Q-resolution mode by limiting beam divergence to study periodically modulated structures with characteristic lengths no less than 100 Å. Furthermore, it supports half-polarized neutron diffraction for investigating complex magnetism and local susceptibility. This report first overviews the proposed science case and the derived requirement. And then, the chosen technical solutions and expected performance will be described.

36 MATERIALS SCIENCE↗

Experimental studies and applications of vanadium oxides.

The electrical and electrochemical properties of V-5 and V-7 vanadium oxides were investigated. The effects of pressure, temperature and moisture on the bulk resistivity of the oxides in powder, sintered, and crystalline form were determined, and the static and dynamic volt-ampere characteristics were obtained. Sintered samples tested showed better electrical stability than the compressed powder samples. Two types of commercially available vanadium pentoxide were heat-treated to obtain various crystalline oxide forms which were mounted on alumina substrates and terminated by thick-film conductors for making electrical connections. Indications are that these materials could have applications as sensors, critical-temperature resistors, high-speed switches, and temperature-compensation elements in hybrid microelectronic circuits.

Williams, L., Jr.↗

Optical scanning system for laser velocimeter

An optical system was developed to provide fast incremental scanning of a backscattered laser velocimeter focus point over a 36-cm distance. The system is used to measure flow velocities at 16 positions along its optical axis and to scan these 16 positions up to 30 times a second. Dwell time at each location is approximately 2 milliseconds. Sample volumes typically are 0.2 mm in diameter by 1.4 cm in length. The optical scanning system consists of a wheel containing plane parallel quartz windows of various thicknesses. The laser velocimeter beams are imaged to a primary focus within the dead airspace of an optical cell. The beams emerging from the cell pass through the windows of the scanning wheel. The refraction of the beams passing through the windows causes an apparent shift of the focus within the optical cell and hence in the test zone. Light scattered from the secondary focus within the test zone is concurrently collected and reimaged through the same optical path which originally projected the primary focus. The reimaged backscattered light containing the velocity information is then collected and focused onto a photomultiplier detector system to complete the scanned laser velocimeter optical system.

Rhodes, D. B.↗

Surface analysis of space telescope material specimens

Qualitative and quantitative data on Space Telescope materials which were exposed to low Earth orbital atomic oxygen in a controlled experiment during the 41-G (STS-17) mission were obtained utilizing the experimental techniques of Rutherford backscattering (RBS), particle induced X-ray emission (PIXE), and ellipsometry (ELL). The techniques employed were chosen with a view towards appropriateness for the sample in question, after consultation with NASA scientific personnel who provided the material specimens. A group of eight samples and their controls selected by NASA scientists were measured before and after flight. Information reported herein include specimen surface characterization by ellipsometry techniques, a determination of the thickness of the evaporated metal specimens by RBS, and a determination of trace impurity species present on and within the surface by PIXE.

Fromhold, A. T.↗

Contamination of grazing incidence EUV mirrors - An assessment

Contamination assessment for space optical systems requires an understanding of the sensitivity of component performance, e.g. mirror reflectance, to materials deposited on the mirror surface. In a previous study, the sensitivity of typical normal incidence mirror coatings to surface deposits of generic hydrocarbons was reported. Recent activity in the development of grazing incidence telescopes for extreme ultraviolet space astronomy has stimulated the need for a similar assessment in the spectral region extending from approximately 100 A to 1000 A. The model used for analysis treats the contamination layer as a continuous thin film deposited on the mirror surface. The mirror surfaces selected for this study are opaque vacuum deposited gold and the uncoated and polished Zerodur. Scatter caused by film irregularities or particulates are not included in this assessment. Parametric evaluations at 100, 500, and 1000 A determine the sensitivity of mirror reflectance to a range of optical constants selected for the generic contaminants. This sensitivity analysis combined with the limited amount of optical data in the EUV for hydrocarbons, is used to select representative optical constants for the three wavelength regions. Reflectance versus contamination layer thickness curves are then calculated and used to determine critical thickness limits based on allowable reflectance change. Initial observations indicate that thickness limits will be highly dependent on the real part of the complex index of refraction of the contaminant film being less than 1.0. Preliminary laboratory measurements of samples contaminated with some commonly encountered hydrocarbons confirm trends indicated in the analytical studies.

Osantowski, John F.↗

Diamonds in detonation soot

Diamonds 4 to 7 nm in diameter have been identified and partially isolated from soot formed in detonations of carbon-forming composite explosives. The morphology of the soot has been examined by transmission electron microscopy (TEM), and the identity of the diamond has been established by the electron diffraction pattern of the TEM samples and by the X-ray diffraction (XRD) pattern of the isolated solid. Graphite is also present in the form of ribbons of turbostatic structure with a thickness of 2 to 4 nm. A fraction, about 25 percent of the soot by weight, was recovered from the crude soot after oxidation of the graphite with fuming perchloric acid. This fraction showed a distinct XRD pattern of diamond and the diffuse band of amorphous carbon. The IR spectrum of these diamonds closely matches that of diamonds recovered from meteorites (Lewis et al., 1987), perhaps indicating similar surface properties after the oxidation. If these diamonds are produced in the detonation itself or during the initial expansion, they exhibit a phenomenal crystal growth rate (5 nm/0.00001 s equal 1.8 m/hr) in a medium with a very low hydrogen/carbon ratio. Because the diamonds will be carried along with the expanding gases, they will be accelerated to velocities approaching 8 km/s.

Greiner, N. Roy↗

Active Control of Fan Noise-Feasibility Study. Volume 2: Canceling Noise Source-Design of an Acoustic Plate Radiator Using Piezoceramic Actuators

The feasibility of using acoustic plate radiators powered by piezoceramic thin sheets as canceling sources for active control of aircraft engine fan noise is demonstrated. Analytical and numerical models of actuated beams and plates are developed and validated. An optimization study is performed to identify the optimum combination of design parameters that maximizes the plate volume velocity for a given resonance frequency. Fifteen plates with various plate and actuator sizes, thicknesses, and bonding layers were fabricated and tested using results from the optimization study. A maximum equivalent piston displacement of 0.39 mm was achieved with the optimized plate samples tested with only one actuator powered, corresponding to a plate deflection at the center of over 1 millimeter. This is very close to the deflection required for a full size engine application and represents a 160-fold improvement over previous work. Experimental results further show that performance is limited by the critical stress of the piezoceramic actuator and bonding layer rather than by the maximum moment available from the actuator. Design enhancements are described in detail that will lead to a flight-worthy acoustic plate radiator by minimizing actuator tensile stresses and reducing nonlinear effects. Finally, several adaptive tuning methods designed to increase the bandwidth of acoustic plate radiators are analyzed including passive, active, and semi-active approaches. The back chamber pressurization and volume variation methods are investigated experimentally and shown to be simple and effective ways to obtain substantial control over the resonance frequency of a plate radiator. This study shows that piezoceramic-based plate radiators can be a viable acoustic source for active control of aircraft engine fan noise.

Pla, F. G.↗

Automated Weld Characterization Using the Thermoelectric Method

The effective assessment of the integrity of welds is a complicated NDE problem that continues to be a challenge. To be able to completely characterize a weld, detailed knowledge of its tensile strength, ductility, hardness, microstructure, macrostructure, and chemical composition is needed. NDE techniques which can provide information on any of these features are extremely important. In this paper, we examine a seldom used approach based on the thermoelectric (TE) effect for characterizing welds and their associated heat affected zone (HAZ). The thermoelectric method monitors the thermoelectric power which is sensitive to small changes in the kinetics of the conduction electrons near the Fermi surface that can be caused by changes in the local microstructure. The technique has been applied to metal sorting, quality testing, flaw detection, thickness gauging of layers, and microscopic structural analysis. To demonstrate the effectiveness of the technique for characterizing welds, a series of tungsten-inert-gas welded Inconel-718 samples were scanned with a computer controlled TE probe. The samples were then analyzed using a scanning electron microscope and Rockwell hardness tests to characterize the weld and the associated HAZ. We then correlated the results with the TE measurements to provide quantitative information on the size of the HAZ and the degree of hardness of the material in the weld region. This provides potentially valuable information on the strength and fatigue life of the weld. We begin the paper by providing a brief review of the TE technique and then highlight some of the factors that can effect the measurements. Next, we provide an overview of the experimental procedure and discuss the results. Finally, we summarize our findings and consider areas for future research.

Fulton, J. P.↗

Immunohistochemical myofiber typing and high-resolution myofibrillar lesion detection in LR white embedded muscle

We have developed a method of fixing, embedding, sectioning, and staining that allows high-resolution detection of myofibrillar structure and myosin immunocytochemical muscle fiber typing in serial semithin sections of LR White plastic embedded muscle at the light microscopic level. Traditional approaches, such as cryostat sections, permit fiber typing, but small myofibrillar lesions (1-3 sarcomeres) are difficult to detect because of section thickness. Semithin sections of hydrophobic resins do not stain well either histochemically or immunocytochemically. Electron microscopy can resolve lesions and discriminate fiber types based on morphology, but the sampling area is small. Our goal was to develop a rapid method for defining both fiber type and high-resolution primary myofibrillar lesion damage. Mild fixation (1-4% paraformaldehyde, 0. 05-0.1% glutaraldehyde) and embedment in a hydrophilic resin (LR White) were used. Myofibrillar structure was extremely well preserved at the light microscopic (LM) level, and lesions could be readily resolved in Toluidine blue stained 500-nm sections. Fiber type was defined by LM immunomyosin staining of serial plastic semithin sections, which demonstrated reciprocal staining patterns for "fast (Sigma M4276) and "total" (skeletal muscle) myosins (Sigma M7523). Copyright 2000 Wiley-Liss, Inc.

NASA Program Fundamental Space Biology↗

Modeling the Spin Equilibrium of Neutron Stars in LMXBs Without Gravitational Radiation

In this paper we discuss the spin-equilibrium of accreting neutron stars in LMXBs. We demonstrate that, when combined with a naive spin-up torque, the observed data leads to inferred magnetic fields which are at variance with those of galactic millisecond radiopulsars. This indicates the need for either additional spin-down torques (eg. gravitational radiation) or an improved accretion model. We show that a simple consistent accretion model can be arrived at by accounting for radiation pressure in rapidly accreting systems (above a few percent of the Eddington accretion rate). In our model the inner disk region is thick and significantly sub-Keplerian, and the estimated equilibrium periods are such that the LMXB neutron stars have properties that accord well with the galactic millisecond radiopulsar sample. The implications for future gravitational-wave observations are also discussed briefly.

Andersson, N.↗

Maps Suggest Transport and Source Processes of PM2.5 at 1 km x 1 km for the Whole San Joaquin Valley, Winter 2011 (Generalizations from DISCOVER-AQ)

We present interpreted data analysis using MAIAC (Multiangle implementation of Atmospheric Correction) retrievals and appropriate RAPid Update Cycle (RAP) meteorology to map respirable aerosol (PM2.5) for the period January and February, 2011. The San Joaquin Valley is one of the unhealthiest regions in the USA for PM2.5 and related morbidity. The methodology evaluated can be used for the entire moderate-resolution imaging spectrometer (MODIS, VIIRS) data record. Other difficult areas of the West: Riverside, CA, Salt Lake City, UT, and Doa Ana County, NM share similar difficulties and solutions. The maps of boundary layer depth for 1116 hr local time from RAP allows us to interpret aerosol optical thickness as a concentration of particles in a nearly well-mixed box capped by clean air. That mixing is demonstrated by DISCOVER-AQ data and afternoon samples from the airborne measurements, P3B (on-board) and B200 (HSRL2 lidar). This data and the PM2.5 gathered at the deployment sites allowed us to estimate and then evaluate consistency and daily variation of the AOT to PM2.5 relationship. Mixed-effects modeling allowed a refinement of that relation from day to day; RAP mixed layers explained the success of previous mixed-effects modeling. Compositional, size-distribution, and MODIS angle-of-regard effects seem to describe the need for residual daily correction beyond ML depth.We report on an extension method to the entire San Joaquin Valley for all days with MODIS imagery using the permanent PM2.5 stations, evaluated for representativeness. Resulting map movies show distinct sources, particularly Interstate-5 (at approx. 1km x 1km resolution) and the broader Bakersfield area. Accompanying winds suggest transport effects and variable pathways of pollution cleanout. Such estimates should allow morbiditymortality studies. They should be also useful for actual model assimilations, where composition and sources are uncertain. We conclude with a description of new work to extend these insights to similar regions, e.g. interior valleys of California, the Po Valley, the Mediterranean litoral, and the Ganges Plain.This work show generalizable use of remote sensing, a major goal of DISCOVER-AQ, Deriving Information on Surface Conditions from COlumn and VERtically Resolved Observations Relevant to Air Quality.

Chatfield, R.↗

The Ice, Cloud, and Land Elevation Satellite-2 (ICESat-2): Science Requirements, Concept, and Implementation

The Ice, Cloud, and land Elevation Satellite (ICESat) mission used laser altimetry measurements to determine changes in elevations of glaciers and ice sheets, as well as sea ice thickness distribution. These measurements have provided important information on the response of the cryosphere (Earths frozen surfaces) to changes in atmosphere and ocean condition. ICESat operated from 2003-2009 and provided repeat altimetry measurements not only to the cryosphere scientific community but also to the ocean, terrestrial and atmospheric scientific communities. The conclusive assessment of significant ongoing rapid changes in the Earths ice cover, in part supported by ICESat observations, has strengthened the need for sustained, high accuracy, repeat observations similar to what was provided by the ICESat mission. Following recommendations from the National Research Council for an ICESat follow-on mission, the ICESat-2 mission is now under development for planned launch in 2018. The primary scientific aims of the ICESat-2 mission are to continue measurements of sea ice freeboard and ice sheet elevation to determine their changes at scales from outlet glaciers to the entire ice sheet, and from 10s of meters to the entire polar oceans for sea ice freeboard. ICESat carried a single beam profiling laser altimeter that produced approximately 70 m diameter footprints on the surface of the Earth at approximately 150 m along-track intervals. In contrast, ICESat-2 will operate with three pairs of beams, each pair separated by about 3 km across-track with a pair spacing of 90 m. Each of the beams will have a nominal 17 m diameter footprint with an along-track sampling interval of 0.7 m. The differences in the ICESat-2 measurement concept are a result of overcoming some limitations associated with the approach used in the ICESat mission. The beam pair configuration of ICESat-2 allows for the determination of local cross-track slope, a significant factor in measuring elevation change for the outlet glaciers surrounding the Greenland and Antarctica coasts. The multiple beam pairs also provide improved spatial coverage. The dense spatial sampling eliminates along-track measurement gaps, and the small footprint diameter is especially useful for sea surface height measurements in the often narrow leads needed for sea ice freeboard and ice thickness retrievals. The ICESat-2 instrumentation concept uses a low energy 532 nm (green) laser in conjunction with single-photon sensitive detectors to measure range. Combining ICESat-2 data with altimetry data collected since the start of the ICESat mission in 2003, such as Operation IceBridge and ESAs CryoSat-2, will yield a 15+ year record of changes in ice sheet elevation and sea ice thickness. ICESat-2 will also provide information of mountain glacier and ice cap elevations changes, land and vegetation heights, inland water elevations, sea surface heights, and cloud layering and optical thickness.

ICESat-2↗

Simple Magnetic Device Indicates Thickness Of Alloy 903

Handheld device called "ferrite indicator" orginally designed for use in determining ferrite content of specimen of steel. Placed in contact with specimen and functions by indicating whether magnet attracted more strongly to specimen or to calibrated reference sample. Relative strength of attraction shows whether alloy overlay thinner than allowable.

Long, Pin Jeng↗

Fast Exciton Diffusion in Monolayer PtSe2

Recently, 2D noble metal dichalcogenides have drawn considerable attention due to their thickness-tunable electronic and optical properties. However, the dynamical properties of photocarriers in these materials are less studied. In this report photocarrier dynamics in monolayer and bilayer PtSe 2 samples prepared by chemical vapor deposition are studied by transient absorption microscopy. Spatially and temporally resolved differential reflectance measurements yield room-temperature exciton lifetimes of 25 and 50 ps for monolayer and bilayer samples, respectively. The exciton diffusion coefficient in monolayer PtSe 2 is found to be as large as 48 cm 2 s -1 . This value is higher than exciton diffusion coefficients of most known monolayer semiconductors. The deduced exciton mobility is close to the theoretical limit of charge carrier mobility of monolayer PtSe 2 . The superior exciton transport property is unique to monolayers, as the exciton diffusion coefficient drops to 6.7 cm 2 s -1 in bilayers PtSe 2 . The novel exciton transport properties, along with its high air stability, make monolayer PtSe 2 an attractive material for ultrathin excitonic devices. These results provide insights on the exciton dynamic properties of 2D PtSe 2 and help develop fundamental understanding on the performance of various optoelectronic devices based on 2D PtSe 2 . .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗