Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

MO-DE-209-02: Tomosynthesis Reconstruction Methods

Digital Breast Tomosynthesis (DBT) is rapidly replacing mammography as the standard of care in breast cancer screening and diagnosis. DBT is a form of computed tomography, in which a limited set of projection images are acquired over a small angular range and reconstructed into tomographic data. The angular range varies from 15° to 50° and the number of projections varies between 9 and 25 projections, as determined by the equipment manufacturer. It is equally valid to treat DBT as the digital analog of classical tomography – that is, linear tomography. In fact, the name “tomosynthesis” stands for “synthetic tomography.” DBT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DBT systems is a hybrid between computed tomography and classical tomographic methods. In this lecture, we will explore the continuum from radiography to computed tomography to illustrate the characteristics of DBT. This lecture will consist of four presentations that will provide a complete overview of DBT, including a review of the fundamentals of DBT acquisition, a discussion of DBT reconstruction methods, an overview of dosimetry for DBT systems, and summary of the underlying image theory of DBT thereby relating image quality and dose. Learning Objectives: To understand the fundamental principles behind tomosynthesis image acquisition. To understand the fundamentals of tomosynthesis image reconstruction. To learn the determinants of image quality and dose in DBT, including measurement techniques. To learn the image theory underlying tomosynthesis, and the relationship between dose and image quality. ADM is a consultant to, and holds stock in, Real Time Tomography, LLC. ADM receives research support from Hologic Inc., Analogic Inc., and Barco NV.; ADM is a member of the Scientific Advisory Board for Gamma Medica Inc.; A. Maidment, Research Support, Hologic, Inc.; Research Support, Barco, Inc.; Scientific Advisory Board, Gamma Medica, Inc.; Scientific Advisory Board, Real-Time Tomography, LLC.; Shareholder, Real-Time Tomography, LLC; J. Mainprize, Our lab has a research agreement with GE Healthcare on various topics in digital mammography and digital tomosynthesis; W. Zhao, Research grant from Siemens Health Care.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP2-04: Multiple Penalties with Different Orders for Structure Adaptive CBCT Reconstruction

Purpose: To combine total variation (TV) and Hessian penalty in a structure adaptive way for cone-beam CT (CBCT) reconstruction. Methods: TV is a widely used first order penalty with good ability in suppressing noise and preserving edges but leads to the staircase effect in regions with smooth intensity transition. The second order Hessian penalty can effectively suppress the staircase effect with extra cost of blurring object edges. To take the best of both penalties we proposed a novel method to combine both for CBCT reconstruction in a structure adaptive way. The proposed method adaptively determined the weight of each penalty according to the geometry of local regions. An specially-designed exponent term with image gradient involved was used to characterize the local geometry such that the weights for Hessian and TV were 1 and 0 respectively at uniform local regions and 0 and 1 at edge regions. For other local regions the weights varied from 0 to 1. The objective functional was minimized using the majorzationminimization approach. We evaluated the proposed method on a modified 3D shepp-logan and a CatPhan 600 phantom. The full-width-at-halfmaximum (FWHM) and contrast-to-noise (CNR) were calculated. Results: For 3D shepp-logan the reconstructed images using TV had an obvious staircase effect while those using the proposed method and Hessian preserved the smooth transition regions well. FWHMs of the proposed method TV and Hessian penalty were 1.75 1.61 and 3.16 respectively, indicating that both TV and the proposed method is able to preserve edges. For CatPhan 600 CNR values of the proposed method were similar to those of TV and Hessian. Conclusion: The proposed method retains favorable properties of TV like preserving edges and also has the ability in better preserving gradual transition structure as Hessian does. All methods performs similarly in suppressing noise. This work was supported in part by National Natural Science Foundation of China (NNSFC) under Grant Nos.60971112 and 61375018 grants from the Cancer Prevention and Research Institute of Texas (RP130109 and RP110562-P2) National Institute of Biomedical Imaging and Bioengineering (R01 EB020366) and a grant from the American Cancer Society (RSG-13-326-01-CCE).

60 APPLIED LIFE SCIENCES↗

TH-CD-207B-09: Task-Driven Fluence Field Modulation Design for Model-Based Iterative Reconstruction in CT

Purpose: There has been increasing interest in integrating fluence field modulation (FFM) devices with diagnostic CT scanners for dose reduction purposes. Conventional FFM strategies, however, are often either based on heuristics or the analysis of filtered-backprojection (FBP) performance. This work investigates a prospective task-driven optimization of FFM for model-based iterative reconstruction (MBIR) in order to improve imaging performance at the same total dose as conventional strategies. Methods: The task-driven optimization framework utilizes an ultra-low dose 3D scout as a patient-specific anatomical model and a mathematical formation of the imaging task. The MBIR method investigated is quadratically penalized-likelihood reconstruction. The FFM objective function uses detectability index, d’, computed as a function of the predicted spatial resolution and noise in the image. To optimize performance throughout the object, a maxi-min objective was adopted where the minimum d’ over multiple locations is maximized. To reduce the dimensionality of the problem, FFM is parameterized as a linear combination of 2D Gaussian basis functions over horizontal detector pixels and projection angles. The coefficients of these bases are found using the covariance matrix adaptation evolution strategy (CMA-ES) algorithm. The task-driven design was compared with three other strategies proposed for FBP reconstruction for a calcification cluster discrimination task in an abdomen phantom. Results: The task-driven optimization yielded FFM that was significantly different from those designed for FBP. Comparing all four strategies, the task-based design achieved the highest minimum d’ with an 8–48% improvement, consistent with the maxi-min objective. In addition, d’ was improved to a greater extent over a larger area within the entire phantom. Conclusion: Results from this investigation suggests the need to re-evaluate conventional FFM strategies for MBIR. The task-based optimization framework provides a promising approach that maximizes imaging performance under the same total dose constraint.

60 APPLIED LIFE SCIENCES↗

Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity quantification compared to SPECT with AC only. The proposed methodology can readily be used to tailor {sup 90}Y SPECT/CT acquisition and reconstruction protocols with different SPECT/CT systems for quantification and improved image quality in clinical settings.

61 RADIATION PROTECTION AND DOSIMETRY↗

Orbital reconstruction and covalent bonding at an oxide interface.

Orbital reconstructions and covalent bonding must be considered as important factors in the rational design of oxide heterostructures with engineered physical properties. We have investigated the interface between high-temperature superconducting (Y,Ca)Ba{sub 2}Cu{sub 3}O{sub 7} and metallic La{sub 0.67}Ca{sub 0.33}MnO{sub 3} by resonant x-ray spectroscopy. A charge of about -0.2 electron is transferred from Mn to Cu ions across the interface and induces a major reconstruction of the orbital occupation and orbital symmetry in the interfacial CuO{sub 2} layers. In particular, the Cu d{sub 3z{sup 2}-r{sup 2}} orbital, which is fully occupied and electronically inactive in the bulk, is partially occupied at the interface. Supported by exact-diagonalization calculations, these data indicate the formation of a strong chemical bond between Cu and Mn atoms across the interface. Orbital reconstructions and associated covalent bonding are thus important factors in determining the physical properties of oxide heterostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective regularized algebraic reconstruction technique for computed tomography

A new fast version of the reconstruction algorithm for computed tomography based on the simultaneous algebraic reconstruction technique (SART) is proposed. The algorithm iteration is asymptotically accelerated using the fast Hough transform from O(n{sup 3}) to O(n{sup 2}logn). Similarly to the algebraic reconstruction technique (RegART), which was proposed by us previously, the regularization operator is applied after each iteration. A bilateral filter plays the role of this operator. The algorithm behavior is investigated using the model experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First fragmentation function measurements from full jet reconstruction in heavy-ion collisions at $\sqrt{s_{\mathrm{NN}}}=200$ GeV by STAR

Measurements of inclusive hadron suppression and di-hadron azimuthal correlations in ultra-relativistic nuclear collisions at RHIC have provided important insights into jet quenching in hot QCD matter, but are limited in their sensitivity due to well-known biases. Full jet reconstruction in heavy-ion collisions would conceptually provide a direct measurement of the energy of the scattered parton before energy loss, alleviating such biases and allowing a measurement of the energy loss probability distribution in a model-independent way from hard probes. In these proceedings we utilize recent progress in the reconstruction of jets in the heavy ion environment and present the first measurement of the fragmentation function from fully reconstructed jets in heavy ion collisions. The fragmentation function measured in central Au+Au collisions at $\sqrt{s_{\mathrm{NN}}}=200$ GeV will be presented and discussed with respect to p+p reference measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of primary vertices at the ATLAS experiment in Run 1 proton–proton collisions at the LHC

This paper presents the method and performance of primary vertex reconstruction in proton–proton collision data recorded by the ATLAS experiment during Run 1 of the LHC. The studies presented focus on data taken during 2012 at a centre-of-mass energy of √s = 8 TeV. The performance has been measured as a function of the number of interactions per bunch crossing over a wide range, from one to seventy. The measurement of the position and size of the luminous region and its use as a constraint to improve the primary vertex resolution are discussed. A longitudinal vertex position resolution of about 30 μm is achieved for events with high multiplicity of reconstructed tracks. The transverse position resolution is better than 20 μm and is dominated by the precision on the size of the luminous region. An analytical model is proposed to describe the primary vertex reconstruction efficiency as a function of the number of interactions per bunch crossing and of the longitudinal size of the luminous region. Agreement between the data and the predictions of this model is better than 3% up to seventy interactions per bunch crossing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the ATLAS track reconstruction algorithms in dense environments in LHC Run 2

With the increase in energy of the Large Hadron Collider to a centre-of-mass energy of 13 TeV for Run 2, events with dense environments, such as in the cores of high-energy jets, became a focus for new physics searches as well as measurements of the Standard Model. These environments are characterized by charged-particle separations of the order of the tracking detectors sensor granularity. Basic track quantities are compared between 3.2 fb -1 of data collected by the ATLAS experiment and simulation of proton–proton collisions producing high-transverse-momentum jets at a centre-of-mass energy of 13 TeV. The impact of charged-particle separations and multiplicities on the track reconstruction performance is discussed. The track reconstruction efficiency in the cores of jets with transverse momenta between 200 and 1600 GeV is quantified using a novel, data-driven, method. The method uses the energy loss, dE/dx, to identify pixel clusters originating from two charged particles. Of the charged particles creating these clusters, the measured fraction that fail to be reconstructed is 0.061±0.006 (stat.)±0.014 (syst.) and 0.093±0.017 (stat.)±0.021 (syst.) for jet transverse momenta of 200–400 GeV and 1400–1600 GeV, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving topological cluster reconstruction using calorimeter cell timing in ATLAS

Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal recon struction in the ATLAS experiment. Topological cell clus tering has proven performant in LHC Runs 1 and 2. It is, however, susceptible to out-of-time pile-up of signals from soft collisions outside the 25 ns proton-bunch-crossing window associated with the event’s hard collision. To reduce this effect, a calorimeter-cell timing criterion was added to the signal-to-noise ratio requirement in the clustering algorithm. Multiple versions of this criterion were tested by reconstructing hadronic signals in simulated events and Run 2 ATLAS data. The preferred version is found to reduce the out-of-time pile-up jet multiplicity by ~50% for jet p T ~ 20 GeV and by ~80% for jet p T ≳ 50 GeV, while not disrupting the reconstruction of hadronic signals of interest, and improving the jet energy resolution by up to 5% for 20 < p T < 30 GeV. Pile-up is also suppressed for other physics objects based on topo-clusters (electrons, photons, τ-leptons), reducing the overall event size on disk by about 6% in early Run 3 pile up conditions. Offline reconstruction for Run 3 includes the timing requirement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction and identification of pairs of collimated τ-leptons decaying hadronically using s=13 TeV pp collision data with the ATLAS detector

This paper describes an algorithm for reconstructing and identifying a highly collimated hadronically decaying τ$$\tau $$-lepton pair with low transverse momentum. When two τ$$\tau $$-leptons are highly collimated, their visible decay products might overlap, degrading the reconstruction performance for each of the τ$$\tau $$-leptons. A dedicated treatment attempting to tag the τ$$\tau $$-lepton pair as a single object is required. The reconstruction algorithm is based on a large radius jet and its associated two leading subjets, and the identification uses a boosted decision tree to discriminate between signatures from τ+τ-$$\tau ^+\tau ^-$$ systems and those arising from QCD jets. The efficiency of the identification algorithm is measured in Zγ$$Z\gamma $$ events using proton–proton collision data at s=13$$\sqrt{s}=13$$ TeV collected by the ATLAS experiment at the Large Hadron Collider between 2015 and 2018, corresponding to an integrated luminosity of 139fb-1$$139\,\text{ fb}^{-1}$$. The resulting data-to-simulation scale factors are close to unity with uncertainties ranging from 26 to 37%.

Aad, G↗

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta (0vββ) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the Laboratori Nazionali del Gran Sasso, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation 0vββ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

Adams, D. Q. [University of South Carolina]↗

Scalable FBP decomposition for cone-beam CT reconstruction

Filtered Back-Projection (FBP) is a fundamental compute intense algorithm used in tomographic image reconstruction. Cone-Beam Computed Tomography (CBCT) devices use a cone-shaped X-ray beam, in comparison to the parallel beam used in older CT generations. Distributed image reconstruction of cone-beam datasets typically relies on dividing batches of images into different nodes. This simple input decomposition, however, introduces limits on input/output sizes and scalability.We propose a novel decomposition scheme and reconstruction algorithm for distributed FPB. This scheme enables arbitrarily large input/output sizes, eliminates the redundancy arising in the end-to-end pipeline and improves the scalability by replacing two communication collectives with only one segmented reduction. Finally, we implement the proposed decomposition scheme in a framework that is useful for all current-generation CT devices (7th gen). In our experiments using up to 1024 GPUs, our framework can construct 40963 volumes, for real-world datasets, in under 16 seconds (including I/O).

Chen, Peng↗

Performance-Portable GPU Acceleration of the EFIT Tokamak Plasma Equilibrium Reconstruction Code

This paper presents the steps followed to GPU-offload parts of the core solver of EFIT-AI, an equilibrium reconstruction code suitable for tokamak experiments and burning plasmas. For this work, we will focus on the fitting procedure that consists of a Grad–Shafranov (GS) equation inverse solver that calculates equilibrium reconstructions on a grid. We will show profiling results of the original code (CPU-baseline), as well as the directives used to GPU-offload the most time-consuming function, initially to compare OpenACC and OpenMP on NVIDIA and AMD GPUs and later on to assess OpenMP performance portability on NVIDIA, AMD and Intel GPUs. We will make a performance comparison for different spatial grid sizes and show the speedup achieved on NVIDIA A100 (Perlmutter-NERSC), AMD MI250X (Frontier-OLCF) and Intel PVC GPUs (Sunspot-ALCF). Finally, we will draw some conclusions and recommendations to achieve high-performance portability for an equilibrium reconstruction code on the new HPC architectures

GPU↗

Precise 3D Track Reconstruction Algorithm for the ICARUS T600 Liquid Argon Time Projection Chamber Detector

Liquid Argon Time Projection Chamber (LAr TPC) detectors offer charged particle imaging capability with remarkable spatial resolution. Precise event reconstruction procedures are critical in order to fully exploit the potential of this technology. In this paper we present a new, general approach to 3D reconstruction for the LAr TPC with a practical application to the track reconstruction. The efficiency of the method is evaluated on a sample of simulated tracks. We present also the application of the method to the analysis of stopping particle tracks collected during the ICARUS T600 detector operation with the CNGS neutrino beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Forward Modeling Method for Analysis and Reconstructions of Orientation Image Map

IceNine is a MPI-parallel orientation reconstruction and microstructure analysis code. It's primary purpose is to reconstruct a spatially resolved orientation map given a set of diffraction images from a high energy x-ray diffraction microscopy (HEDM) experiment (1). In particular, IceNine implements the adaptive version of the forward modeling method (2, 3). Part of IceNine is a library used to for conbined analysis of the microstructure with the experimentally measured diffraction signal. The libraries is also designed for tapid prototyping of new reconstruction and analysis algorithms. IceNine is also built with a simulator of diffraction images with an input microstructure.

Frankie Li, ShiuFai↗

HUNTRESS: a fast heuristic for reconstructing phylogenetic trees of tumor evolution (HUNTRESS) v0.1

We introduce HUNTRESS (Histogrammed UNion Tree REconStruction heuriStic), a computational method for tumor phylogeny reconstruction from noisy genotype matrices derived from single-cell sequencing data, whose running time is linear with the number of cells and quadratic with the number of mutations. Provided that the input genotype matrix includes no false positives, each cellular subpopulation is at least a user defined fraction of the total number of cells, and the number of cells are much bigger than the number of mutations considered, HUNTRESS computes the ground truth tumor phylogeny with high probability. On simulated data HUNTRESS is faster than available alternatives with comparable or better accuracy. Additionally, the phylogenies reconstructed by HUNTRESS on two single-cell sequencing data sets agree with the best known evolutionary scenarios for the associated tumors.

Buluc, Aydin↗

DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction

Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the reconstructed images, making it a challenging inverse problem. We present DOLCE, a new deep model-based framework for LACT that uses a conditional diffusion model as an image prior. Diffusion models are a recent class of deep generative models that are relatively easy to train due to their implementation as image denoisers. DOLCE can form high-quality images from severely under-sampled data by integrating data-consistency updates with the sampling updates of a diffusion model, which is conditioned on the transformed limited-angle data. We show through extensive experimentation on several challenging real LACT datasets that, the same pre-trained DOLCE model achieves the SOTA performance on drastically different types of images. Additionally, we show that, unlike standard LACT reconstruction methods, DOLCE naturally enables the quantification of the reconstruction uncertainty by generating multiple samples consistent with the measured data.

Kim, Hyojin↗